Spelling suggestions: "subject:"etheses -- bimechanical engineering"" "subject:"etheses -- bymechanical engineering""
21 |
Condition monitoring of a rotor bearing system.Grobler, Herbert Alfred. 22 May 2013 (has links)
The key objective for this research was to construct an experimental test rig along with a finite
element model. Both had to accommodate a certain extent of misalignment and unbalance to
provide induced vibrations in the system. Misalignment and unbalance was then varied in
magnitude to identify the effect it has on the system. The next variable was the rotor speed
and its effects. Finally the experimental and theoretical results were compared and the slight
differences have been outlined and described.
A rotor supported by two bearings with a disk attached to the middle and a three jaw coupling
at the one end was considered for this research. The three jaw coupling consists out of two
hub elements with concave jaws and a rubber element that fits in-between the jaws. The
rotor-bearing system was subjected to unbalance at the disk and both angular and parallel
misalignment at the coupling. Misalignment was achieved by offsetting the centre of rotation
of the rotor and the motor shaft. Finite element analysis, along with Lagrange method, was
used to model the behaviour of the system. A mathematical model for the three jaw coupling
was derived to simulate its behaviour. The second order Lagrange model was reduced to a first
order and solved using the Runge-Kutta method. Experimental results were obtained from a
test rig and used to validate the theoretical results. Time domain and frequency spectrum
were used to display the results. / Thesis (M.Sc.Eng.)-University of KwaZulu-Natal, Durban, 2011.
|
22 |
Second order analyses methods for stirling engine designSnyman, H. 03 1900 (has links)
Thesis (MScIng( Mechanical Engineering)--University of Stellenbosch, 2007. / 121 Leaves printed single pages, preliminary pages a-l and numbered pages 1-81. / ENGLISH ABSTRACT:In the midst of the current non-renewable energy crises specifically with regard to fossil fuel, various
research institutions across the world have turned their focus to renewable and sustainable development.
Using our available non.renewable resources as efficiently as possible has been a focal point the past
decades and will certainly be as long as these resources exist Various means to utilize the world's
abundant and freely available renewable energy has been studied and some even introduced and
installed as sustainable energy sources, Electricity generation by means of wind powered turbines,
photo-voltaic cells, and tidal and wave energy are but a few examples.
Modern photo-voltaic cells are known to have a solar to electricity conversion efficiency of 12% (Van
Heerden, 2003) while wind turbines have an approximate wind to electricity conversion efficiency of 50%
(Twele et aI., 2002). This low solar to electricity conversion efficiency together with the fact that
renewable energy research is a relatively modern development, lead to the investigation into methods
capable of higher solar to electricity conversion efficiencies. One such method could be to use the
relatively old technology of the Stirling cycle developed in the early 1800's (solar to electricity conversion
efficiency in the range of 20.24 % according Van Heerden, 2003). The Stirling cycle provides a method
for converting thermal energy to mechanical power which can be used to generate electricity, One of the
main advantages of Stirling machines is that they are capable of using any form of heat source ranging
from solar to biomass and waste heat.
This document provides a discussion of some of the available methods for the analysis of Stirling
machines. The six (6) different methods considered include: the method of Beale, West, mean-pressurepower-
formula (MPPF), Schmidt, idea! adiabatic and the simple analysis methods. The first three (3) are
known to be good back-of-the-envelope methods specifically for application as synthesis tools during
initialisation of design procedures, while the latter three (3) are analysis tools finding application during
Stirling engine design and analysis procedures. These analysis methods are based on the work done by
Berchowitz and Urieli (1984) and form the centre of this document. Sections to follow provide a
discussion of the mathematical model as well as the MATlAB implementation thereof. Experimental tests
were conducted on the Heinrici engine to provide verification of the simulated resutls. Shortcomings of
these analyses methods are also discussed in the sections to follow. Recommendations regarding
improvements of the simulation program, possible fields of application for Stirling technology, as well as
future fields of study are made in the final chapter of this document. A review of relevanl literature
regarding modern applications of Stirling technology and listings of companies currently manufacturing
and developing Stirling machines and findings of research done at various other institutions are provided. / AFRIKAANSE OPSOMMING:Die tempo van uitputling van die wereld se nie-hernubare energiebronne die afgelope jare het aanleiding
gegee daartoe dal daar loenemend fokus toegespits word op die ontwikkeling van hernubare
alternatiewe. Meer doeltreffende benutting van die wereld se nie-hernubare energie is reeds 'n fokus
punt, vir navorsers reg oor die wereld, vir die afgelope dekades. Die aarde se oorvloedryke hernubare
energie bronne word reeds met verskeie metodes ontgin. Die omskakeling van wind-, son- en gety
energie na elektrisieteids is net 'n paar voorbeelde.
Die effektiwiteid van sonkrag na elektrisietyds omskakeling van moderne fotovo!la'iese selle is in die orde
van 12% (Van Heerden, 2003) terwyl die doeltreffendeid van wind energie na elektrisiteit omskakelling in
die orde van 50% (Twele et at, 2002) is. Hierdie relatief lae omskelings doeltreffendeid van sonkrag na
elektrisietyd, tesame met die feit dat die hernubare industrie nag relatief jonk is, lei lot die soeke na ander
meer doellreffende moontlikhede Die Stirling siklus is nie 'n mod erne beginsel nie, maar die toepassing
daarvan veral in die hernubare energie industrie is wei 'n relatiewe nuwe beg rip, veral in teme van die
omskakeling van sonkrag na elektriese energie (gemiddelde sonkrag na lektriese energie omskakelings
doellreffendeid in die orde van 20-24% is gevind deur Van Heerden, 2003). Die omskakeling van
lermiese energie na meganiese energie is sekerlik die hoof uitkomsle van die Stirling siklus, alhoewel dit
ook toepassing vind in die verkoefingsindustrie. Die feit dat die Stirling siklus van enige vorm van
termiese energie (bv. son. biomassa, asook hilte geproduseer as byproduk tydens sekere prosesse)
gebruik kan maak. is een van die redes wat die tegnologie 56 aanloklik maak, spesifiek !.o,v. die
hernubare energie sektor.
Ses (6) metodes vir die analise van die Stirling siklus word in hierdie dokument bespreek. Dit slui! die
volgnde in: Beale-, West-, die gemiddelde-druk-krag-metode (GDKM), Schmidt-, adiabatiese- en die
eenvoudige analise melodes. Die eerste drie (3) metodes is handige berekenings metodes Iydens die
aanvangs en sinlesefase van Stirling enjin ontwerp, lerwyl die laaste drie (3) meer loegespils is op die
volledige ontwerps- en analisefases gedurende die Stirling eniin ontwerps proses. Die drie (3) analise
melodes is gebaseer op die werk wat deur Berchowitz en Urieli (1984) gedoen is en maak die kern van
die dokument uit. Die wiskundige model, implimentering daarvan in MATlAB, sowel as die
eksperimentele verifieering van die resultate word bespreek. Tekortkominge van die analise metodes
word ook aangespreek in elke hoofsluk. Moontlikke verbeterings len opsigte van die verskeie aannames
word in die finale hoofsluk van die dokumenl aangespreek. Verskeie voorgestelde riglings vir
toekomslige navorsings projekle word ook in die finale hoofstuk van die dokument genoem. 'n Kort oorsig
van die relevanle lileraluur in verband mel huidige loepassings van die Stirling legnologie, asook die
name van maatskappye wal tans hierdie tegnologiee ontwikkel en vervaardig, word genoem.
|
23 |
The effect of ionization of spray on the wetting characteristics of an adiabatically cooled heat exchangerEsterhuyse, Bernard de Waal 12 1900 (has links)
Thesis (MScIng)--University of Stellenbosch, 2004. / ENGLISH ABSTRACT: An investigation was made into the use of pre-cooling of air with evaporative cooling
as a means of improving the performance of air-cooled heat exchangers (finned tube)
under conditions of ambient temperatures above maximum design values and during
times of increased load. A review of previous research on this subject indicated that
the concept is theoretically sound, but that practical application thereof is still limited.
It was found that one of the major areas of concern is the wetting of the heat
exchanger finned surface and subsequent corrosion.
Mathematical models were derived for the behavior of liquid droplets in free air
stream conditions and droplets that have penetrated a laminar hydrodynamic boundary
layer formed on a flat plate. These two models were combined to determine the
behavior of a liquid droplet for its entire lifetime. It was found that evaporation of
droplets in a boundary layer resulted in major improvements in heat transfer. In an
attempt to prevent droplets from impacting and wetting the finned tube heat
exchanger, the use of electrostatically charged water spray was investigated.
Experiments were performed to determine the charging performance of a capacitive
electrostatic nozzle. It was found that this type of nozzle successfully charged droplets
in a spray. Experiments were then performed whereby electrostatic spray was sprayed
on to a heat exchanger with a similar electric charge as the droplets. It was found that
droplet deposition decreased significantly as the charge on the droplets was increased.
However, total prevention of deposition could not be achieved, since the equipment
used could not produce high enough voltages. This concept shows some promise, and
it is recommended that further research be performed on it. At this stage, no reliable
method of evaporative precooling of air has yet been found. The only viable option
for cooling capacity shortages at present is the construction of large air-cooled heat
exchangers or the addition of wet cooling towers. / AFRIKAANSE OPSOMMING: Voorverkoeling van lug deur middel van verdampingsverkoeling vir die gebruik met
droë lug-verkoelde vinbuis warmteruilers is ondersoek as ‘n manier om die
verkoelingseffektiwiteit te verhoog gedurende tye van hoë omgewingstemperature en
verhoogde las. ‘n Ondersoek van navorsing op die gebied het getoon dat die konsep in
teorie moontlik is, maar dat daar nog geen praktiese implementering plaasgevind het
nie. Dit blyk dat die benatting en korrosie van die vinbuise een van die hoof probleme
is.
Wiskundige modelle is afgelei vir die gedrag van ‘n water druppel in ‘n vrye lug
stroom en vir ‘n druppel in ‘n laminêre hidrodinamiese grenslaag op ‘n plat plaat. Die
twee modelle is gekombineer om die gedrag van ‘n druppel gedurende sy totale
leeftyd te bepaal. Die model het getoon dat verdamping van ‘n druppel in die
grenslaag ‘n drastiese verhoging in die hitteoordrag koëffisiënt veroorsaak. Die
gebruik van elektrostaties gelaaide sproei om te verseker dat die vinbuis warmteruiler
droog bly is ondersoek. Eksperimente is uitgevoer om die elektriese laaivermoëns van
‘n kapasitiewe elektrostatiese mondstuk te bepaal. Daar is gevind dat die tipe
mondstuk suksesvol is in die laai van druppels. Toetse is toe uitgevoer waartydens
gelaaide druppels gespuit is op ‘n warmteruiler met dieselfde lading as die druppels.
Daar is gevind dat die duppel neerslag op die warmteruiler merkwaardig afneem
namate die lading op die druppels verhoog is. Die warmteruiler kon egter nie totaal
droog gehou word nie, aangesien die toerusting gebruik vir die toetse nie ‘n hoë
genoeg spanning kon gee nie. Hierdie konsep is belowend, en dit word aanbeveel dat
verdere navorsing daarop gedoen word. Op hierdie stadium is daar nog geen
betroubare metode gevind om die verkoelings effektiwiteit van lugverkoelde
warmteruilers met verdampings verkoeling te bewerkstellig nie. Die enigste sinvolle
opsie tans is die kostruksie van groter lugverkoelde warmteruilers of die konstruksie
van nat koeltorings.
|
24 |
Thermo-economic analysis of a french fries processing plant at Lambert's BayPotgieter, Johan 12 1900 (has links)
Thesis (MScIng)--University of Stellenbosch, 2004. / ENGLISH ABSTRACT: In the literature study energy efficiency is discussed in general, as well as certain critical areas
of importance to this study. In addition, measuring and monitoring equipment, and energy
inefficiencies in steam and refrigeration systems are reviewed briefly.
In the energy analysis, an energy audit strategy is discussed in general. A walkthrough audit
of the plant was conducted with specific focus on visible losses in the steam, refrigeration and
production line systems. An energy analysis, as discussed in Chapter 3, indicates the main
energy consumers, with steam being the biggest consumer of energy.
The main consumers of refrigeration energy are the cold stores, flow freezer and blast freezer.
Energy consumption in the cold stores can be minimised mechanically, while refrigeration
energy of the flow freezer and blast freezer can be minimised through the modification of
production activity.
The main consumers of steam at the processing plant are the dryers, oil fryer, blanchers and
steam peeler. Improved energy savings at the dryers can be obtained through optimisation of
moisture and heat transfer mechanisms, while the energy of the blanchers and steam peeler
can be combined by means of heat exchangers. The transfer of waste energy by means of a
finned-tube heat exchanger from the steam peeler to the blanchers was investigated.
The newly installed coal boiler shows capacity for improving the quality of steam, as well as
efficiency, by incorporating an economiser and separator for improving steam quality,
automatic TDS control and blow-down heat recovery.
The product life cycle is discussed considering future automation that could lead to energy
and labour savings.
Lastly the utilisation of product waste as a future research subject is discussed.
A confidentiality agreement was entered into with Oceana. / AFRIKAANSE OPSOMMING: In die literatuurstudie word energie-effektiwiteit oor die algemeen bespreek, asook sekere
kritieke areas wat vir die ondersoek van belang is. Hierbenewens word meettoerusting
vlugtig bespreek, asook energie-oneffektiwiteite in die verkoeling- en stoomstelsels.
In die energie-ontleding word ’n energie-ouditstrategie in die breë bespreek. ’n Deurstapoudit
van die aanleg is uitgevoer met spesifieke fokus op sigbare verliese in die
verkoelingstelsel, stoomstelsel en produksielyn. Die samestelling van energieverbruik in die
aanleg word uiteengesit in Hoofstuk 3, waar dan ook aangedui word dat stoom die grootste
energieverbruiker is.
Die hoofverbruikers van verkoelingsenergie is die koelkamers, die deurvloei-vrieskamer en
die blitsvrieskamer. By die koelkamers kan verliese meganies geminimeer word, terwyl
veranderinge aan produksie-aktiwiteite energieverbruik by die deurvloei-vrieskamer en die
blitsvrieskamer kan verlaag.
Die hoofverbruikers van stoom by die verwerkingsaanleg is die droërs, oliebraaier,
blansjeerders en stoomskiller. Energie-effektiwiteit by die droërs kan verhoog word deur
vog- en warmte-oordrag optimaal te laat plaasvind deur korrekte instandhoudingsprosedures.
Energieverbruik by die stoomskiller en blansjeerders kan deur middel van warmteruilers
gekombineer word. ’n Ondersoek na die energie-integrasie van die stoomskiller en die
blansjeerders is dan ook uitgevoer. Die pas geïnstalleerde steenkoolketel toon ruimte vir die
verhoging van energie-effektiwiteit deur die daarstel van ’n ekonomiseerder – ’n skeier wat
die gehalte van die stoom verbeter, outomatiese TDS-beheer en afblaasherwinning.
Die produk se lewensiklus word bespreek ten einde toekomstige outomatisering te motiveer in
terme van energie- en arbeideffektiwiteit, asook die uitskakeling van onnodige blootstelling
van die produk aan omgewingstemperature.
Laastens word die herwinning van afvalstowwe as ’n toekomstige navorsingsprojek bespreek.
’n Vertroulikheidsooreenkoms is met Oceana gesluit en word eerbiedig.
|
25 |
Technical and economic evaluation of the utilisation of solar energy at South Africa's Sanae IV Base in AntarcticaOlivier, Jurgen Richter 12 1900 (has links)
Thesis (MScEng (Mechanical and Mechatronic Engineering))--University of Stellenbosch, 2005. / There are numerous challenges that have to be overcome in order to generate the electrical and
thermal energy required to power Antarctic research stations in a technically, economically and
environmentally suitable manner. Consequently the costs associated with generating energy at
these latitudes are high, and ways are constantly being sought to improve energy generation
methods and protect the pristine environment. These endeavours are strongly encouraged by the
Antarctic Treaty.
This thesis aims to investigate the technical and economic feasibility of using solar energy at
South Africa’s SANAE IV (South African National Antarctic Expedition IV) station in
Antarctica. The idea of using solar energy in Antarctica is not novel, and as is shown a number
of stations have already capitalised on opportunities to generate savings in this manner.
Similarly, at SANAE IV, there exists the opportunity to alleviate an increased summer energy
load on the station and reduce diesel consumption through the proper implementation of such a
system. There is also ample scope to use wind energy, which would have a marked positive
impact on the base’s operation.
The data used in this thesis was obtained mainly during the 2004/2005 takeover expedition to
South Africa’s SANAE IV station in Antarctica. Included are measurements of total and diffuse
radiation that were measured during the months of January and February 2005, and which form
an important part of the investigation. Since there are currently no radiation sensors, or any
historical record of measured radiation at the station, the only measured data available from
SANAE IV was the data recorded during the 2004/2005 takeover expedition. By further
collecting archived values of fuel consumption, electricity generation and load profiles, an
energy audit of the station was also completed during the 2004/2005 takeover expedition.
The expected savings that could be generated by solar systems were calculated by considering
the use of both photovoltaic and solar thermal devices at the South African station. The 40 kW
photovoltaic system that was investigated was able to significantly reduce the load on the dieselelectric
generators, however it was only possible to fully recover the initial costs sunk into
commissioning the system after 21 years. The installation of such a system would equate to a Net
Present Value of 302 915 Rand at the end of the 25 year system lifetime (assuming a real hurdle
rate of 8 % and fuel price escalation rate of 5 %), saving 9 958 litres of diesel annually generating energy at a cost of 3.20 Rand/kWh. It should be noted, however, that under more
ideal conditions (i.e. less attractive alternative investment opportunities, higher fuel price
escalation rates and a stronger emphasis on environmental concerns) investment into a
photovoltaic system could potentially breakeven after approximately 10-15 years, while
simultaneously significantly improving base operation.
Furthermore, it was found that a flat-plate solar thermal collector utilised with the snow smelter
at SANAE IV is better suited to generating savings than photovoltaic devices. The average cost
of generating electricity after commissioning such a system with a 143 m2 collector field would
be approximately 3.13 Rand/kWh, as opposed to the 3.21 Rand/kWh of the current diesel-only
system, and would realise an annual fuel saving of approximately 12 245 litres. The system
would arrive at a breakeven point after approximately 6 years, and represent a Net Present Value
of 2 148 811 Rand after 25 years. By further considering environmental factors such as the cost
of removing soiled snow from Antarctica and diesel fuel emissions the magnitude of the net
present savings would increase by approximately 500 000 Rand over the expected 25 year
project lifetime.
The opportunity to install a solar energy system at SANAE IV therefore warrants action. There is
potential not only to generate savings over the operational lifetime but also to preserve the
environment in accordance with the desires of the Antarctic Treaty. It is firmly believed that with
careful planning and implementation such a project can and should be successfully undertaken. / Centre for Renewable and Sustainable Energy Studies
|
26 |
The design of a low-noise rotor-only axial flow fan seriesVan der Spuy, Sybrand Johannes 12 1900 (has links)
ENGLISH ABSTRACT: A design routine was derived for designing a series of rotor-only axial flow fans. The routine was
applied by designing two different series of axial flow fans. The first design was for a general
application rotor-only axial flow fan. This fan series was designed, built and tested in co-operation
with Howden Air Industries for both research and commercial purposes. The second design was for
a low-noise fan series, which was designed, built and tested by the University of Stellenbosch for
research purposes only.
The design theory used the principle of blade cropping, meaning that one blade was designed to fit
all the different fan sizes. The fan series was designed for diameters ranging from 3 15 mm to 1000
mm. The fan rotors were designed to conform to a velocity profile of minimum exit kinetic flux. The
general application fan design was concentrated around the popular fan diameter sizes of 500 rnm,
560 mm and 630 mm and a rotor speed of 1440 rpm, using a commercially available fan series as
reference. The low-noise fan design concentrated on one fan size only, namely 630 mm, while also
making use of the principle of forward blade sweep. The remaining fan design principles stayed the
same as for the general application fan design. The F-series airfoils were used as blade sections for
both fan designs.
Both fan series were tested for fan noise and performance in accordance with the BS 848 Standards
part 1 (1980) and 2 (1985). A selection of fan diameter sizes was tested for the general application
fan to verify its perfo!"mance over a range of fan sizes. This indicated a fan series with a wide range
of efficient operation, including excellent noise characteristics. A 630 mm diameter fan was used to
test the low-noise fan series. It showed both high efficiency and low noise characteristics. The
reduction in fan noise achieved with the low-noise fan does not justi1)' the amount of work and costs
involved in the designing process, compared to the general application fan. / AFRIKAANSE OPSOMMING: 'n Ontwerpsroetine vir die ontwerp van 'n reeks enkelrotor aksiaalwaaiers is ontwikkel. Die roetine
is toegepas deur twee verskillende reekse aksiaalwaaiers te ontwerp. Die eerste ontwerp was vir 'n
algemene toepassings enkelrotor aksiaalwaaier. Die waaierreeks is ontwerp, gebou en getoets in
samewerking met Howden Air Industries vir beide navorsings - en kommersieIe doeleindes. Die
tweede ontwerp was vir 'n lae geraas waaierreeks. Die reeks is ontwerp, gebou en getoets deur die
Universiteit van Stellenbosch vir navorsingsdoeleindes.
Die onwerpsteorie het gebruik gemaak van die beginsel van lemverkorting, waardeur een lem
ontwerp is om op al die groottes waaierdeursnee te pas. Die waaierreekse is ontwerp vir
waaierdeursnee tussen 315 mm en 1000 mm. Die rotors is ontwerp om 'n uitlaatsneIheidsprofiel te
gee wat 'n minimum verlies in kinetiese energie toelaat. Die algemene toepassings waaierontwerp
het gekonsentreer rondom die gewilde waaierdeursnee van 500 mm, 560 en 630 mm. Dit is ontwerp
vir 'n rotorspoed van 1440 met 'n kommersieel beskikbare waaierreeks wat as verwysing gebruik is.
Die lae geraas waaierreeks het op slegs een waaiergrootte gekonsentreer, naamlik 630 mm. Die lae
geraas waaierreeks is ook ontwerp met vorentoe gekurfde lemme. Die res van die ontwerpsbeginsels
was dieseIfde as vir die algemene toepassings waaierreeks. Die F-reeks vleuelprofiele is gebruik vir
die lemseksies van beide waaierreekse.
Beide waaiereekse is getoets vir waaiergeraas en -effektiwiteit deur gebruik te maak van die BS 848
Standaarde deel 1 (] 980) en 2 (] 985). 'n Verskeidenheid van waaierdeursnee van die algemene
toepassings waaierreeks is getoets om die waaier se vertoning oor 'n gebied van waaiergroottes te
bepaal. Die resuItaat was 'n waaierreeks met 'n wye gebied van effektiewe werking, asook
uitstekende geraaseienskappe. 'n 630 mm Deursnee waaier is gebruik om die lae geraas waaier te
toets. Die toetse het 'n waaier getoon wat beide hoe effektiwiteit en lae geraaseienskappe het. Die
afname in waaiergeraas wat verkry is met die lae geraas waaier, in vergelyking met die algemene
toepassings waaier, regverdig egter rue die werk en kostes verbonde aan die ontwerp van die
waaierreeks nie.
|
27 |
Numerical investigation of fan performance in a forced draft air-cooled steam condenserBredell, J. R. (Johann Richard) 12 1900 (has links)
Thesis (MScIng)--University of Stellenbosch, 2005. / ENGLISH ABSTRACT: Forced draft air-cooled steam condensers (ACSCs) consisting of multiple fan units are used
in direct cooled power plants to condense steam in a closed steam cycle. Axial flow fans
located below an A-frame configuration of finned tube heat exchanger bundles, force ambient
air through the system. In so doing, heat from the condensing steam is rejected to the
environment via the finned tubes. The performance of an air-cooled system is proportional to
the air mass flow rate and the temperature difference between the finned tubes and the
ambient air. A variation in either will directly affect the efficiency of the steam turbines.
Air flow distortions at the fan inlet caused by structures, wind and other fans may result in a
significant reduction in flow rate as well as fan blade vibration. This phenomenon has an
adverse affect on the cooling capacity of an ACSC, and consequently turbine performance,
due to a decrease in air mass flow rate. In this study the effect of inlet flow distortions on fan
performance (i.e. flow rate and fan shaft power) in an ACSC is numerically investigated by
modelling a section (or sector) of such a system using the commercial computational fluid
dynamics (CFD) code, FLUENT. Fan performance at different platform heights, and
corresponding different degrees of inlet flow distortions, is investigated.
The performance of two types of axial flow fans are also compared. The two fans have the
same diameter, number of blades and rotational speed, but feature different blade designs,
and hub-tip-ratios of respectively 0.153 and 0.4. A fan model based on blade element theory,
better known as an actuator disc model, is used to numerically model the fans.
Previous experimental studies have shown that a solid walkway installed along the edge or
periphery of an ACSC platform can significantly increase the flow rate through the fans
situated along the platform edge. The effects of such a walkway, and other windscreens on
fan performance, are numerically investigated.
Numerical predictions correlate with earlier experimental results: the flow rate and fan shaft
power are decreased by inlet flow distortions. It was found that the fan with a hub-tip-ratio of
0.4 was less affected by these flow distortions. The addition of a walkway increased the flow
rate through the edge fan by up to 48 %. It is furthermore shown that wind effects can only be
accurately modelled if the entire ACSC is considered. / AFRIKAANSE OPSOMMING: Geforseerde-trek lugverkoelde kondensators wat bestaan uit ʼn aantal waaier-eenhede, word
in direk-verkoelde kragstasies gebruik om stoom in ʼn geslote stoomkringloop te kondenseer.
Aksiaalvloei-waaiers wat onder ʼn A-raam-konfigurasie van vinbuisbundels geïnstalleer is,
forseer omgewingslug deur die stelsel. Sodoende word die hitte van die kondenserende stoom
aan die omgewing oorgedra deur middel van die vinbuise. Die warmteoordragkapasiteit van
ʼn lugverkoelde kondensator is eweredig aan die massavloei-tempo van die lug, asook die
temperatuurverskil tussen die vinbuise en die lug. ʼn Verandering in enige van dié faktore sal
die benuttingsgraad van die stoomturbines direk beïnvloed.
Lugvloeiversteurings by die waaier-inlate wat veroorsaak word deur geboue, wind en ander
waaiers kan lei tot aansienlike verlagings in vloeitempo deur die waaiers. Sekondêre effekte
soos waaierlemvibrasie kan ook veroorsaak word. In hierdie studie word die effek van inlaatvloeiversteurings
op waaierwerkverrigting (dws vloeitempo en waaierdrywing) ondersoek
deur ʼn seksie (of sektor) van ʼn lugverkoelde kondensator te modelleer deur gebruik te maak
van die kommersiële numeriese vloeidinamika-pakket, FLUENT. Waaierwerkverrigting
word by verkillende platformhoogtes, en gevolglik verskillende grade van inlaatvloeiversteurings,
ondersoek.
Twee verskillende waaiers word ook vergelyk. Die waaiers het dieselfde diameter, aantal
lemme en rotasiespoed, maar het verkillende lem ontwerpe, en naaf-lempunt-verhoudings van
onderskeidelik 0.153 en 0.4. ʼn Waaiermodel wat gebaseer is op lem-element-teorie, beter
bekend as ʼn aksie-skyf-model, word gebruik om die waaiers numeries te modelleer.
Vorige eksperimentele studies het bewys dat ʼn loopvlak om die rand van lugverkoelde
kondensators die vloeitempo deur waaiers aansienlik kan verhoog. Die effek van so ʼn
loopvlak, en ander windskerms word numeries ondersoek.
Numeriese voorspellings stem ooreen met eksperimentele resultate: die vloeitempo en
waaierdrywing word verlaag deur inlaat-vloeiversteurings. Dit is bevind dat die waaier met ʼn
naaf-lempunt-verhouding van 0.4, minder beïnvloed word deur vloeiversteurings. ʼn Loopvlak
het die vloeitempo deur die randwaaier met tot 48 % verhoog. Dit is ook bewys dat windeffekte
alleenlik gemodelleer kan word deur die hele lugverkoelde kondensator in ag te neem.
|
28 |
Investigation of performance enhancing devices for the rain zones of wet-cooling towersTerblanche, Riaan 03 1900 (has links)
Thesis (MScEng)--University of Stellenbosch, 2008. / ENGLISH ABSTRACT: The performance of a natural draught wet-cooling tower can be improved by reducing the
average drop size in the rain zone. In this thesis, the effect of installing different horizontal
grids below the fill on drop size in the rain zone is investigated experimentally and
theoretically. A specially designed horizontal grid consisting of evenly spaced slats and a grid
made from expanded metal sheeting are tested. Drop size distribution measurements are taken
below different cooling tower fills to determine the respective Sauter mean drop sizes and also
below different configurations of splash grids to determine the reduction in drop size. Drop
break-up through a grid of horizontally placed slats is modelled and compared to measured
data to determine the optimum configuration in terms of spacing between the grid and fill, slat
width and slat spacing. A cross flow rain zone is modelled under different air and water flow
combinations with CFD for two distributions that represent the rain with and without splash
grids and the results are compared. The Merkel transfer characteristic for all the flow
conditions using both distributions are determined using a Lagrangian, Merkel, Poppe and e-
NTU method in order to quantify the increase in rain zone Merkel number. Pressure drop over
the cross flow rain zone is also determined and compared for the two distributions under
considerations. / AFRIKAANSE OPSOMMING: Die verkoelingsvermoë van ‘n reënsone van ‘n natuurlike trek nat koeltoring kan verbeter
word deur die verkleining van die gemiddelde druppelgrootte. In hierdie tesis word die effek
wat horisontale roosters op die druppelgrootte het, wanneer dit onder die pakking geïnstalleer
is, eksperimenteel en teoreties ondersoek. ‘n Spesiaal ontwerpte rooster bestaande uit
horisontaal gepakte latte en ‘n gerolde metaal rooster word onderskeidelik vir hierdie doel
gebruik. Druppelgrootte metings word geneem onder verskillende koeltoring
pakkingsmateriaal om die Sauter gemiddelde diameter te bepaal, asook onder die verskillende
rooster opstellings om die verkleinde druppelgrootte te bepaal wat die rooster veroorsaak.
Druppelopbreking deur ‘n laag horisontaal gepakte latte word gemodelleer en vergelyk met
gemete data om sodoende die beste kombinasie tussen die afstand onder die
pakkingsmateriaal, latwydte en latspasiëring te bepaal. ‘n Kruisvloei reënsone word
gemodelleer met CFD onder verkillende lug- en watervoeikombinasies vir twee
druppelverdelings wat die reënsone met en sonder roosters verteenwoordig. Die Merkel
oordragskoëffisiënt vir die twee verdelings word bereken en vergelyk deur van ‘n Lagrange- ,
Merkel- , Poppe- en e-NTU metode gebruik te maak om sodoende die verbetering in reënsone
Merkelgetal te kwantifiseer. Drukvalle oor die reënsone word ook bereken en vergelyk vir die
twee verdelings wat beskou is.
|
29 |
Analytical and a numerical ground resonance analysis of a conventionally articulated main rotor helicopterEckert, Bernd 03 1900 (has links)
Thesis (MScEng (Mechanical and Mechatronic Engineering))--University of Stellenbosch, 2007. / The helicopter is a prime example of a nonlinear multi-body dynamic system that is subjected to
numerous forces and motions to which the system must react. When a helicopter, with a
conventionally articulated rotor head, is resting on the ground with its rotor spinning, a condition
called ground resonance can develop. Ground resonance is a specific self-excited oscillation of
the helicopter and is caused by the interaction between the main rotor blades and the fuselage
structure. Inertia forces of the blades perform an out-of-phase lagging motion, which reacts with
the elastic landing gear of the helicopter. For certain values of the main rotor angular velocity, the
frequency of these inertia forces coincides with a natural vibration frequency of the fuselage
structure. If this occurs, the inertia forces of the lagging blades produce oscillations of the
fuselage, which then further excite the lagging motion of the blades. This interaction is
responsible for an instability of conventionally articulated main rotor helicopters, which is called
ground resonance.
The ground resonance phenomenon is investigated by means of a classical analytical approach
in which the ground resonance equations are derived from Euler-Bernoulli beam theory and
verified with results in literature. These equations are required to discuss ground resonance
stability in further detail and determine the specific regions in which the phenomenon occurs.
These results are incorporated in a simplified numerical model using an elastic multiple-body
dynamics analysis program called DYMORE to simulate the South African Rooivalk Combat
Support Helicopter. DYMORE is a program that offers nonlinear multi-body dynamic analysis
code, using the finite element method, which was specifically developed for helicopter modelling.
The complexity of helicopter modelling generally requires large amounts of computing power to
ensure reasonable processing time. In order to prevent excessive computational time, the
numerical model will be simplified in terms of aerodynamic and structural aspects. The scope of
the numerical investigation is, therefore, limited to the ground resonance phenomenon without the
effect of aerodynamic forces and representing the fuselage as multi-body beam structures of
specified stiffness.
|
30 |
Analytical modelling and optimization of a thermal convective microfluidic gyroscopeVosloo, Surika 03 1900 (has links)
Thesis (MScEng (Mechanical and Mechatronic Engineering))--University of Stellenbosch, 2010. / ENGLISH ABSTRACT: This thesis deals with the mathematical optimization of the detecting chamber of a thermal convective
microfluidic gyroscope and the comparison of several different optimization strategies.
An analytical model is developed for the gyroscope and some design considerations are discussed. Sequential
approximate optimization strategies are explained and compared to each other by implementing
test problems fromthe literature. The optimization problem is formulated from the analytical model
and implemented using the different optimization strategies. Results are presented and compared to
find the most effective optimization strategy.
A sequential approximate optimization algorithm is implemented in MATLAB and tested using the gyroscope
design problem and common test problems from the literature. Results and iteration history are
compared with an existing FORTRAN implementation. / AFRIKAANSE OPSOMMING: Hierdie tesis handel oor die wiskundige optimering van die deteksiekamer van n termies-konvektiewe
mikrovloeier giroskoop en die vergelyking van verskeie optimeringsstrategieë.
’n Analitiese model is opgestel vir die giroskoop en verskeie ontwerpsoorwegings word bespreek. Sekwensiëel
benaderde optimeringsstrategieë word bespreek en met mekaar vergelyk, deur dit op toetsprobleme
uit die literatuur toe te pas. Die optimeringsprobleem is geformuleer uit die analitiese model
en geimplementeer deur gebruik te maak van verskeie optimeringsstrategieë. Resultate word getoon en
vergelyk, omdie mees effektiewe optimeringsstrategie te vind.
’n Algoritme vir sekwensiëel benaderde optimeringsprobleme is inMATLAB geimplementeer. Die giroskoop
probleem, asook probleme uit die literatuur, is gebruik om resultate en iterasie geskiedenis te vergelyk
met ’n bestaande FORTRAN implementasie.
|
Page generated in 0.1055 seconds