• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 1
  • Tagged with
  • 7
  • 7
  • 5
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

An energy audit manual for small manufacturing companies with a case study of a maugus manufacturing company

Belock, Keith Allan January 1995 (has links)
No description available.
2

Effect of welder group size on individual respiratory exposures to welding fumes

Palmer, Benjamin L. January 2010 (has links) (PDF)
Thesis--University of Oklahoma. / Bibliography: leaf 44.
3

Potential compliance impact of reduced permissible exposure limit for hexavalent chromium in an aerospace production and maintenance facility

Shamhart, Andrew Bradley. January 2006 (has links) (PDF)
Thesis--University of Oklahoma. / Bibliography: leaves 36-37.
4

Ecoconception des ciments : synthèse, hydratation et durabilité / Eco design of cements : synthesis, hydration and durability

Kleib, Joelle 06 December 2018 (has links)
Les ciments sulfoalumineux sont des liants hydrauliques qui, jusqu’aujourd’hui ne sont pas normalisés et ne possèdent donc pas une composition fixe. La teneur en ye’elimite – la phase principale de ce ciment- peut varier de 5 à 70 %. Or la composition du ciment sulfoalumineux (la composition du clinker ainsi que le pourcentage de gypse ajouté) est un paramètre critique qui contrôle sa réactivité, ses performances mécaniques, ainsi que sa durabilité. L’objectif principal de cette thèse est donc l’étude de l’influence de la composition des ciments sulfoalumineux sur leurs propriétés techniques, telles que les performances mécaniques et durabilité. Trois axes principaux ont été abordés. Tout d’abord une étude de l’influence de la composition du ciment sulfoalumineux (25-75 % en masse de ye’elimite) sur ses propriétés hydrauliques et mécaniques ainsi que sur la valeur limite en élément trace (Zn) a été menée. Dans ce but trois ciment sulfoalumineux (25, 50 et 75 % en masse de ye’elimite) ont été synthétisés. Ensuite l’effet de la variabilité de ce ciment sur sa durabilité dans l’eau pure et sulfatée a été investigué par rapport à un ciment sulfoalumineux commercial. Enfin, une étude des potentialités du ciment sulfoalumineux commercial à inhiber la réaction alcali silice dans les mortiers, lors de l’utilisation d’un granulat réactif (Silex), a été conduite. Il en résulte de cette étude qu’une augmentation de taux de ye’elimite dans le ciment sulfoalumineux engendre une augmentation des performances mécaniques. La valeur limite en Zn est de 0,3 % indépendamment de la composition du ciment sulfoalumineux. Par contre cette dernière influence la durabilité de ces ciments. Les résultats révèlent que même si la formulation contenant 75 % en ye’elimite confère les meilleures performances mécaniques, sa durabilité était la plus faible due à l’absence de stratlingite dans sa matrice cimentaire. Enfin, l’utilisation du ciment sulfoalumineux présente des bonnes potentialités à inhiber la réaction alcali silice. / Sulfoaluminate cements are hydraulic binders that, until today, are not standardized and therefore do not have a fixed composition. The content of ye'elimite - the main compound of this cement - can vary from 5 to 70 %. However, the composition of sulfoaluminate cement (clinker composition as well as the percentage of added gypsum) is a critical parameter that controls its reactivity, mechanical performance, as well as its durability. The main objective of this thesis is to study the influence of sulfoaluminate cements composition on their technical properties, such as mechanical performances and durability. Three main axes were discussed in this work. First, the influence of the sulfoaluminate cement composition (25-75 wt. % of ye'elimite) on its hydraulic and mechanical properties, as well as on the threshold limit of Zn, was studied. For this purpose three sulfoaluminate cements (25, 50 and 75 wt. % of ye'elimite) were synthesized. Then the effect of the variability of this cement on its durability in pure and sulphated water was investigated compared to a commercial sulfoaluminate cement. Finally, a study of the potentialities of commercial sulfoaluminate cement to inhibit the alkali silica reaction in mortars, when using a reactive aggregate (flint), was conducted. This study reveals that an increase in ye'elimite content in the sulfoaluminate cement increases the mechanical performance. The threshold limit of Zn is 0.3 % independently of the sulfoaluminate cement composition. Contrariwise, the sulfoaluminate cement composition influences the durability of these cements. Although the formulation containing 75 % of ye’elimite gives the best mechanical performances, its durability was lowest due to the absence of stratlingite in its cement matrix. Finally, the use of sulfoaluminate cement has good potential towards the inhibition of the alkali silica reaction.
5

Occupational exposure of health workers to electromagnetic fields in the magnetic resonance imaging environment

Grobler, A.D. 02 1900 (has links)
Thesis (M. Tech.) -- Central University of Technology, Free State, 2008
6

Characterization of risk from airborne benzene exposure in the state of Florida

Johnson, Giffe. January 2008 (has links)
Dissertation (Ph.D.)--University of South Florida, 2008. / Title from PDF of title page. Document formatted into pages; contains 98 pages. Includes vita. Includes bibliographical references.
7

Considerations and Development of a Ventilation on Demand System in Konsuln Mine

Gyamfi, Seth January 2020 (has links)
Ventilation on demand (VOD) concept has earned significant worldwide attention by several mining companies in recent years. It is a concept where airflow is provided only to areas that require ventilation. The implementation of the concept has resulted in significant savings in annual energy consumption and cost for several companies globally. The research presented in this thesis sought to present the VOD system as an alternative solution and strategy to improve the ventilation system of Konsuln mine. The system is expected to cope with a planned increase in production rate and meet requirements in the new Swedish Occupational Health & Safety (OH&S) regulations, Arbetsmiljöverkets förtfattningssamling (AFS) 2018:1, which is based on the EU directive 2017/164 where Threshold Limit Value (TLV) for gases have been significantly reduced and provide safe work environment for workers in the mine. The thesis work started with planning and execution of a PQ (Pressure – Quantity) survey to calibrate the existing ventilation model of Konsuln mine. This was to ensure that the model is reasonably accurate to give reliable simulation predictions of the performance of Konsuln ventilation system in its current state and for the future. The good correlation between the modelled and underground measured values validated the model for further ventilation planning. The study further investigated and analyzed the current and future ventilation demand of LKAB test mine, Konsuln, to design a VOD system for its operations.The work outlined three main VOD design scenarios I, II, and III based on the proposed production plan, schedule, and the mining process that present the underground working conditions on the three main levels (436, 486 and 536) of Konsuln mine. Diesel, battery-powered, heat, and blast simulations were carried out for all the scenarios in the calibrated ventilation model using VentSim Design simulation software. The model was again used to estimate the annual ventilation power cost for the VOD scenarios to highlight the benefit and cost savings advantage under the VOD design system to deliver enough airflow quantity compared to the conventional system of ventilation. Simulation results showed that about 15.6% – 49.1% and 76.4% - 86.7% of significant cost savings will be achieved for diesel and battery-powered machineries respectively, while still supplying the needed amount of air to working areas to keep contaminants below their Threshold Limit Value -Time Weighted Average (TLV-TWA) and provide a good working environment. For additional benefits and savings of the Ventilation on Demand (VOD) system implementation, some considerations for equipment, personnel positioning and identification, monitoring system, and stations have also been discussed in this work.  These include; (i) Utilization of LKAB’s database system, Giron, in addition to mounting tags with unique IDs on machineries, to track the route of LHDs and trucks to deal with the challenge of airflow supply shortfall associated with auxiliary fans adjustment to affect target locations. (ii) Installation of temperature sensors, flow meters, gases and Diesel Particulate Matter (DPM) monitoring systems at specific, appropriate, and optimal locations in the mine for efficient implementation of the VOD system strategy. The heat simulations for both diesel and battery-powered machineries were carried out for the month of July when the highest temperatures in Kiruna are often recorded for the summer. They predicted the highest temperatures in working areas to be well below the limit used in Australia, 28°C Wet Bulb (WB). Four scenarios A, B, C and D were also considered for blast clearance time simulation using both the ramp and exhaust shaft. The blast simulation results indicated that the time to dilute and clear blast fumes through the exhaust shaft saves some clearance time compared to exhaustion through the ramp, although the shaft exhaustion will require additional financial commitment to purchase and install exhaust fans on each of the three main levels of the mine. Nevertheless, major ventilation work and practices such as removal of regulator in front of primary fans, additional radon measurement, and good auxiliary ventilation practices have been recommended to improve and actualize the benefits outlined in this work.

Page generated in 0.0656 seconds