• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Protótipo para medição das propriedades viscoelásticas de tecidos moles / Prototype to measurement of the viscoelastic properties of soft tissues

Padula, Daniel Paulino Figueiredo 03 May 2007 (has links)
O estudo de força aplicada em função da deformação dos materiais é um método comum para estudar as propriedades mecânicas dos mesmos. Este trabalho descreve o desenvolvimento do protótipo de um instrumento dedicado à medição das propriedades viscoelásticas de tecidos moles. O protótipo é composto por um módulo de excitação, um de medição do deslocamento e outro de medição da carga, arranjados de forma compacta para proporcionar a sua aplicação em centro cirúrgico. O módulo de medição do deslocamento é baseado em um sensor magnetoresistivo posicionado eqüidistante entre dois pequenos magnetos cilíndricos (diâmetro = 3mm, comprimento = 5mm) invertidos. Um dos magnetos foi acoplado na base do próprio sensor e o outro no eixo do pistão. Nesta configuração, o campo magnético sobre o sensor é praticamente nulo na condição inicial e diferente de zero quando o pistão se desloca. O módulo de medição da carga possui um pequeno porta-amostra e permite realizar medidas em amostras de até 1 grama. A deformação sobre as amostras pode ser realizada de forma dinâmica e estática. A deformação dinâmica é feita usando um sistema eletromagnético, baseado em alto-falante, energizado com corrente alternada. A deformação estática é feita comprimindo a amostra através do deslocamento do oscilador sobre a mesma, usando um controle micrométrico. Durante as medidas, as amostras são envolvidas em óleo de parafina para minimizar os atritos de contato. As medições dinâmicas da carga e do deslocamento do pistão são feitas através de um amplificador Lock-in conectado ao microcomputador por uma interface GPIB. Foram realizados testes em amostras de diferentes propriedades mecânicas, tais como parafinas, borracha de silicone, fígado bovino, gelatina de porco, gelatina de porco irradiada, carne de porco e carne de frango. A variação da amplitude do sinal durante a deformação da amostra foi bastante notória para pequenas variações nas propriedades mecânicas e geométricas da mesma. Para as amostras citadas acima, ambos os sinais da variação do deslocamento e da carga foram diferentes e reprodutíveis. Estes estudos mostraram que, com um sistema simplificado e de baixo custo, é possível avaliar pequenas alterações das propriedades mecânicas em pequenas amostras de tecido biológico mole. Baseado nos resultados deste estudo, pode-se concluir que o protótipo desenvolvido apresenta sensibilidade para caracterizar as propriedades elásticas de tecidos biológicos moles. / The study of deformation of materials when submitted to knowledge force is a common method to study their mechanical properties. This work describes the development of a prototype of a system dedicated to the measurement of the viscous-elastic properties of soft tissues. This system is composed of three coupled modulus: one for mechanical excitement, one displacement measurement and one to load measurement. All of them are arranged in a compact form to provide their application in surgical centers. The module of measurement of the displacement is based on a magneto resistive sensor located between an equidistant of two small cylindrical magnetos (diameter = 3 mm, length = 5 mm) aligned and with magnetic poles inverted. One of the magnetos was connected to the support of sensor and the other to the piston. In this configuration, the magnetic field on the sensor is practically null in the initial condition and different from zero when the piston is moving. The module of measurement of the load has a small sample-place and allows carrying through measured samples of up to 1 gram. The deformation on the samples can be carried through dynamic and static forms. The dynamic deformation is made using an electromagnetic system, based in loudspeaker, energized with an alternating chain. The static deformation is made compressing the sample by the displacement of the oscillator on it using a micrometric control. During the measures the samples are involved in paraffin oil to minimize the resistance force caused by the contact. The dynamic measurements of the load and the displacement of the piston are made through an amplifier Lock-in interfaced to the microcomputer by GPIB cable. Tests in samples of different mechanical properties, such as paraffin, silicone rubber, bovine liver, gelatin of pig, meat of pig and chicken were carried out. The variation on the strain and load output for dynamic and static stresses show the potential of the prototype developed to evaluate mechanical proprieties of small samples. Both output signals of the displacement and load had been reproducible. These studies had shown that, with a simplified and low cost system it is possible to evaluate small alterations of the mechanical properties in small soft biological tissues.
2

Protótipo para medição das propriedades viscoelásticas de tecidos moles / Prototype to measurement of the viscoelastic properties of soft tissues

Daniel Paulino Figueiredo Padula 03 May 2007 (has links)
O estudo de força aplicada em função da deformação dos materiais é um método comum para estudar as propriedades mecânicas dos mesmos. Este trabalho descreve o desenvolvimento do protótipo de um instrumento dedicado à medição das propriedades viscoelásticas de tecidos moles. O protótipo é composto por um módulo de excitação, um de medição do deslocamento e outro de medição da carga, arranjados de forma compacta para proporcionar a sua aplicação em centro cirúrgico. O módulo de medição do deslocamento é baseado em um sensor magnetoresistivo posicionado eqüidistante entre dois pequenos magnetos cilíndricos (diâmetro = 3mm, comprimento = 5mm) invertidos. Um dos magnetos foi acoplado na base do próprio sensor e o outro no eixo do pistão. Nesta configuração, o campo magnético sobre o sensor é praticamente nulo na condição inicial e diferente de zero quando o pistão se desloca. O módulo de medição da carga possui um pequeno porta-amostra e permite realizar medidas em amostras de até 1 grama. A deformação sobre as amostras pode ser realizada de forma dinâmica e estática. A deformação dinâmica é feita usando um sistema eletromagnético, baseado em alto-falante, energizado com corrente alternada. A deformação estática é feita comprimindo a amostra através do deslocamento do oscilador sobre a mesma, usando um controle micrométrico. Durante as medidas, as amostras são envolvidas em óleo de parafina para minimizar os atritos de contato. As medições dinâmicas da carga e do deslocamento do pistão são feitas através de um amplificador Lock-in conectado ao microcomputador por uma interface GPIB. Foram realizados testes em amostras de diferentes propriedades mecânicas, tais como parafinas, borracha de silicone, fígado bovino, gelatina de porco, gelatina de porco irradiada, carne de porco e carne de frango. A variação da amplitude do sinal durante a deformação da amostra foi bastante notória para pequenas variações nas propriedades mecânicas e geométricas da mesma. Para as amostras citadas acima, ambos os sinais da variação do deslocamento e da carga foram diferentes e reprodutíveis. Estes estudos mostraram que, com um sistema simplificado e de baixo custo, é possível avaliar pequenas alterações das propriedades mecânicas em pequenas amostras de tecido biológico mole. Baseado nos resultados deste estudo, pode-se concluir que o protótipo desenvolvido apresenta sensibilidade para caracterizar as propriedades elásticas de tecidos biológicos moles. / The study of deformation of materials when submitted to knowledge force is a common method to study their mechanical properties. This work describes the development of a prototype of a system dedicated to the measurement of the viscous-elastic properties of soft tissues. This system is composed of three coupled modulus: one for mechanical excitement, one displacement measurement and one to load measurement. All of them are arranged in a compact form to provide their application in surgical centers. The module of measurement of the displacement is based on a magneto resistive sensor located between an equidistant of two small cylindrical magnetos (diameter = 3 mm, length = 5 mm) aligned and with magnetic poles inverted. One of the magnetos was connected to the support of sensor and the other to the piston. In this configuration, the magnetic field on the sensor is practically null in the initial condition and different from zero when the piston is moving. The module of measurement of the load has a small sample-place and allows carrying through measured samples of up to 1 gram. The deformation on the samples can be carried through dynamic and static forms. The dynamic deformation is made using an electromagnetic system, based in loudspeaker, energized with an alternating chain. The static deformation is made compressing the sample by the displacement of the oscillator on it using a micrometric control. During the measures the samples are involved in paraffin oil to minimize the resistance force caused by the contact. The dynamic measurements of the load and the displacement of the piston are made through an amplifier Lock-in interfaced to the microcomputer by GPIB cable. Tests in samples of different mechanical properties, such as paraffin, silicone rubber, bovine liver, gelatin of pig, meat of pig and chicken were carried out. The variation on the strain and load output for dynamic and static stresses show the potential of the prototype developed to evaluate mechanical proprieties of small samples. Both output signals of the displacement and load had been reproducible. These studies had shown that, with a simplified and low cost system it is possible to evaluate small alterations of the mechanical properties in small soft biological tissues.
3

Structure et Mécanique du pli vocal humain : caractérisation et modélisation multi-échelles / Human vocal fold structure and mechanics : multi-scale characterisation and modelling

Cochereau, Thibaud 18 March 2019 (has links)
Le pli vocal humain possède des propriétés vibratoires exceptionnelles. Il est capable de supporter de grandes déformations, pour différent type de chargement, de manière répétée et réversible. Ces propriétés vibro-mécaniques particulières sont étroitement liées à sa microstructure: une structure multi-couches complexe fortement hétérogène composées de réseaux de fibres protéique. Cependant, il est encore aujourd'hui difficile de décrire précisément l'implication des spécificités microstructurales du pli dans son comportement biomécanique.Afin de préciser ce lien et d'aller vers une meilleure compréhension du comportement du tissu vocal, cette étude se propose d'aborder la problématique sous trois approches complémentaires, mélant caractérisation microstructurale, caractérisation mécanique et modélisation numérique. Dans un premier temps, la microstructure du pli a été étudiée emph{ex vivo} à l'aide d'une technique originale basée sur la tomographie à rayon X. L'usage de tomographie synchrotron par contraste de phase a permis de révéler la structure du tissu à différentes échelles. En particulier, des clichés 3D à forte résolution de la structure fibreuse des couches supérieures et musculaires du tissu ont pu être acquis. Ces clichés ont donné lieu à une analyse 3D quantitative de l'arrangement fibreux, permettant la détermination de descripteur d'orientation et de géométrie 3D des fibres.Dans un second temps, le comportement mécanique du tissu sous différentes conditions de chargement a été étudié. Un protocole a été proposé, afin de caractériser un même échantillon en traction, en compression et en cisaillement. Ces essais ont permis de compléter les connaissances existantes sur la biomécanique de pli, et constitue des données de références importantes pour la construction et la validation de modèle numérique.A partir des données acquises expérimentalement, un modèle micro mécanique a été développé. Ce modèle a la spécificité de prendre en compte l'arrangement 3D du tissu à travers une représentation idéalisée mais pertinente de sa microstructure fibreuse. Les réponses macroscopiques prédites pour différents chargements ont pu être comparées à l'expérience pour validation. A l'échelle microscopique, la cinématique des fibres au cours du chargement a pu être simulée. Les micromécanismes ayant lieu au cours de la déformation du réseau fibreux ont ainsi pu être identifiés, ouvrant de nouvelles perspectives dans la compréhension des propriétés multi-échelles du tissu. / The human vocal fold owns exceptional vibratory properties. It is capable of withstanding large deformations, for different types of loading, in a repeated and reversible manner. These particular vibro-mechanical properties are closely linked to its microstructure: a multi-layer complex structure composed of highly heterogeneous protein fibre networks. However, it is still difficult today to describe precisely the implication of the microstructural specificities of the fold in its biomechanical behaviour.In order to clarify this link and to move towards a better understanding of the behaviour of the vocal tissue, this study proposes to approach the problem under three complementary approaches, combining microstructural characterization, mechanical characterization and numerical modelling. First, the microstructure of the fold was studied emph{ex vivo} using an original technique based on X-ray tomography. The use of synchrotron tomography in phase retrieval mode has revealed the structure of the tissue at different scales. In particular, high-resolution 3D images of the fibrous structure of the upper and muscular layers of the tissue were acquired. These images gave rise to a quantitative 3D analysis of the fibrous arrangement, allowing the determination of descriptors of orientation and 3D geometry of the fibers.In a second step, the mechanical behaviour of the fabric under different loading conditions was studied. A protocol has been proposed to characterize the same sample in tension, compression and shear. These tests have complemented existing knowledge on fold biomechanics, and constitute important reference data for the construction and validation of digital models.Finally, based on the data acquired experimentally, a micro-mechanical model was developed. This model has the specificity to take into account the 3D arrangement of the tissue through an idealized but relevant representation of its fibrous microstructure. The macroscopic responses predicted for different loading conditionds could be compared to the experiment for validation. At the microscopic scale, the kinematics of the fibres during the loading could be simulated. The micromechanisms that occur during the deformation of the fibrous network could thus be identified, opening new perspectives in the understanding of the multi-scale properties of the tissue.

Page generated in 0.0819 seconds