• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Instrumentation optique pour la caractérisation des tissus : analyse de la complémentarité et des limites techniques de fluorescence hyperspectrale et de Tomographie Optique Cohérente en vue de leur intégration multimodale. / Optical instrumentaation for biological tissues caracterization : Complementarity and limits analysis of hyperspectral fluorescence technic and otpical coherence tomography for multimodal integration

Méteau, Jérémy 08 July 2014 (has links)
L'objectif de ce travail de recherche est le développement d'un système fibré d'imagerie point par point d'auto fluorescence multi-excitation, de tissus biologiques en utilisant la technique de fluorescence hyperspectrale et l'étude d'un système de tomographie optique cohérente comme possible modalité supplémentaire. La première partie de ce rapport présente les propriétés optique des tissus biologiques et les fluorophores pertinents pour la détection de tumeurs cancéreuses. La deuxième partie présente l'instrumentation du système d'imagerie de fluorescence et l'analyse hyperspectrale des résultats obtenus in vitro.Il est démontré la pertinence de ce type d'analyse qui permet de déterminer la concentration de certains fluorophores. La troisième partie présente le système de tomographie optique cohérente appelé "scan free" OCT car il permet de réaliser des images sans déplacement d'éléments optiques. Ce système est caractérisé et présente des fonctionnalités intéressantes comme la compensation de la dispersion dépendante de la profondeur. Les divers résultats obtenus montrent que ces deux techniques sont complémentaires car elles apportent des informations de nature différentes. La première technique donne de se informations sur la composition biochimique des tissus, la seconde donne des information sur la structure. / The aim of this activity is the development of a mono point imaging fiber system which uses hyperspectral multi-excitation auto fluorescence technique for biological tissues and the study of an Optical Coherence Tomography system like another modality. At first, this report presents the optical properties of biological tissues and the relevant fluorophores for cancerous tumors detection. Secondly, the fluorescence imaging system instrumentation and hyperspectral analysis are presented with in vitro results. The third part presents the "scan free" optical coherence tomography system which is able to image without optical displacement. It's characterized and have interesting functionality like depth dependant dispersion compensation. These both techniques are complementary because they get different kind of information. The information of the first one is about biochemical composition of the tissues and the information of the second one is about the stucture.
2

Amplification parametrique optique en regime femtoseconde et tomographie optique coherente : deux methodes d'imagerie proche infrarouge dans des milieux diffusants.

Doule, Claude 30 November 2000 (has links) (PDF)
Les travaux présents dans ce mémoire concernent l'imagerie par voie optique proche infrarouge dans un milieu qui diffuse la lumiere. L'application visee est une imagerie in vivo de l'intérieur des tissus biologiques. Deux techniques expérimentales différentes, opérant en configuration de retrodiffusion, ont ete développées. Leur principe commun est la sélection temporelle de la lumière revenant de l'objet éclaire. Pour la première technique, l'amplification paramétrique optique en régime femtoseconde a permis la réalisation d'une porte temporelle de 200 femtosecondes. Les images résolues temporellement sont obtenues a la cadence vidéo, directement a deux dimensions. Le choix d'un accord de phase non colineaire de type ii permet a la fois l'optimisation de la résolution spatiale latérale et l'obtention des images résolues temporellement sur fond noir. Les performances de cette technique ont été évaluées a travers différents milieux artificiels, liquides ou solides, qui diffusent plus ou moins fortement vers l'avant. Pour la seconde technique, une diode superluminescente remplace avantageusement la source laser femtoseconde de la technique precedente. C'est alors la faible longueur de cohérence temporelle de la source lumineuse qui permet la selection temporelle du signal lumineux grâce a une mesure interferometrique. Pour cette technique, connue sous le nom de tomographie optique cohérente (oct), nous avons mis en uvre un système de détection hétérodyne en modulant la phase du faisceau signal grâce a l'effet electro-optique. Des images de tissus biologiques, acquises point par point, ont pu ainsi être réalisées : par exemple une coupe longitudinale d'un il de lapin et une image 2d, perpendiculairement a sa surface, d'un oignon.

Page generated in 0.1098 seconds