• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • Tagged with
  • 17
  • 17
  • 7
  • 6
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Prevalencia de sobreinflación del globo del tubo endotraqueal intraoperatorio y evaluación de la estimación por palpación digital

Trujillo Huaccho, Luis Arnaldo January 2003 (has links)
Objetivo: Determinar la prevalencia de sobreinflacion del globo del tubo endotraqueal en los pacientes operados con anestesia general intubados y evaluar la precisión del método de palpación digital del globo piloto como estimación de la presión del globo. Diseño: Estudio descriptivo, transversal, prospectivo. Material y métodos: Ingresaron al estudio 233 pacientes ASA I, II y III sometidos a diversas cirugías con anestesia general intubados con tubos endotraqueales con globos de alto-volumen baja-presión en el Hospital Guillermo Almenara. Se realizaron las mediciones cuando el paciente estaba en la etapa de mantenimiento. Se midió la presión del globo con un aparato electrónico. Al anestesiólogo que estaba en la sala de operaciones se le pidió que palpara el globo piloto y que estimara si el globo estaba con inflado inadecuado, normal o sobreinflado. Para el análisis estadístico se utilizo Chi cuadrado, ANDEVA y T Test de Student. Resultados: Ingresaron al estudio 110 varones y 123 mujeres. La edad promedio fue 55.3 ± 16.8 años. En el 99.2 % de los casos el tipo de anestesia que se utilizo fue anestesia general balanceada, utilizándose para el mantenimiento Isoflourano en 175 pacientes y Sevofluorane en 57 pacientes, en ningún paciente se utilizo Oxido nitroso. Los pacientes estaban con relajación muscular por el uso de Vecuronio (156 pacientes) o Atracurio (77 pacientes). El opiode utilizado en todos los pacientes fue Fentanilo. En los varones los tubos utilizados fueron de número 8.5 en el 64.5 % de los casos y número 8.0 en el 30 % de los casos. En las mujeres tubos número 7.5 en el 62.6 % de los casos y tubo número 8.0 en el 19.5 % de los casos. La presión del globo encontrada en 122 pacientes (52.4 %) fue mayor de 40 cm H2O (Sobreinflado), en 61 pacientes (26.2 %) estuvo entre 25 a 40 cm H2O (Inflado normal) y en 50 pacientes (21.5 %) la presión del globo fue menor de 25 cm H2O (Inflado inadecuado). La precisión del método clínico de palpación digital del globo piloto para detectar que el globo esta sobreinflado tuvo una Sensibilidad de 49.04 % y para inflado inadecuado de 20 %. La precisión de este método no mejora con el tiempo de experiencia como anestesiólogo. Conclusión: El presente estudio muestra que es necesario contar rutinariamente en todos los casos de pacientes anestesiados con anestesia general intubados con un sistema de medición de la presión del globo que nos asegure inflar el globo dentro de limites normales pues el método estimación por palpación digital del globo piloto no es confiable.
2

Evaluación de la calidad de Intubación con tres diferentes dosis de rocunario

Espinoza Vargas, Milagros María Esther, Hualpa Huamaní, Ana Meida January 2002 (has links)
Introducción: las condiciones de intubación con rocuronio varían de acuerdo a la dosis administrada, pudiendo lograrse proporciones diferentes de condiciones adecuadas o inadecuadas. Se investigaron los efectos de 1 DE95, 2 DE95 y >3DE95. Objetivos: comparar las condiciones de intubación con diferentes dosis de rocuronio en pacientes programados para cirugía electiva. Material y métodos: se empleó una escala de valoración de la relajación muscular, la escala de Domaoal para poder comparar los resultados. Los operadores completaron una ficha de reporte sobre las condiciones de intubación para poder hacer las comparaciones. Resultados: la comparación entre los valores en la escala de Domaoal, clasificación de Cormack-Lehane, escala de Adnet y tiempo de intubación de los pacientes tratados con diferentes dosis de rocuronio sometidos a intubación endotraqueal demostró la existencia de diferencia significativa. Conclusiones: con el empleo de rocuronio se logra condiciones de intubaciones buenas y excelentes en pacientes medicados con dosis 2DE95 o más. El empleo de 1 DE95 está asociado a un porcentaje significativamente incrementado de condiciones de intubación inadecuadas.
3

Prevalencia de sobreinflación del globo del tubo endotraqueal intraoperatorio y evaluación de la estimación por palpación digital

Trujillo Huaccho, Luis Arnaldo January 2003 (has links)
Objetivo: Determinar la prevalencia de sobreinflacion del globo del tubo endotraqueal en los pacientes operados con anestesia general intubados y evaluar la precisión del método de palpación digital del globo piloto como estimación de la presión del globo. Diseño: Estudio descriptivo, transversal, prospectivo. Material y métodos: Ingresaron al estudio 233 pacientes ASA I, II y III sometidos a diversas cirugías con anestesia general intubados con tubos endotraqueales con globos de alto-volumen baja-presión en el Hospital Guillermo Almenara. Se realizaron las mediciones cuando el paciente estaba en la etapa de mantenimiento. Se midió la presión del globo con un aparato electrónico. Al anestesiólogo que estaba en la sala de operaciones se le pidió que palpara el globo piloto y que estimara si el globo estaba con inflado inadecuado, normal o sobreinflado. Para el análisis estadístico se utilizo Chi cuadrado, ANDEVA y T Test de Student. Resultados: Ingresaron al estudio 110 varones y 123 mujeres. La edad promedio fue 55.3 ± 16.8 años. En el 99.2 % de los casos el tipo de anestesia que se utilizo fue anestesia general balanceada, utilizándose para el mantenimiento Isoflourano en 175 pacientes y Sevofluorane en 57 pacientes, en ningún paciente se utilizo Oxido nitroso. Los pacientes estaban con relajación muscular por el uso de Vecuronio (156 pacientes) o Atracurio (77 pacientes). El opiode utilizado en todos los pacientes fue Fentanilo. En los varones los tubos utilizados fueron de número 8.5 en el 64.5 % de los casos y número 8.0 en el 30 % de los casos. En las mujeres tubos número 7.5 en el 62.6 % de los casos y tubo número 8.0 en el 19.5 % de los casos. La presión del globo encontrada en 122 pacientes (52.4 %) fue mayor de 40 cm H2O (Sobreinflado), en 61 pacientes (26.2 %) estuvo entre 25 a 40 cm H2O (Inflado normal) y en 50 pacientes (21.5 %) la presión del globo fue menor de 25 cm H2O (Inflado inadecuado). La precisión del método clínico de palpación digital del globo piloto para detectar que el globo esta sobreinflado tuvo una Sensibilidad de 49.04 % y para inflado inadecuado de 20 %. La precisión de este método no mejora con el tiempo de experiencia como anestesiólogo. Conclusión: El presente estudio muestra que es necesario contar rutinariamente en todos los casos de pacientes anestesiados con anestesia general intubados con un sistema de medición de la presión del globo que nos asegure inflar el globo dentro de limites normales pues el método estimación por palpación digital del globo piloto no es confiable.
4

Conocimientos y prácticas que tienen las enfermeras sobre la aspiración de secreciones en pacientes intubados en la Unidad de Cuidados Intermedios del Hospital Nacional Hipólito Unanue, 2002

Apolinario Mendivil, Roxana Emilia January 2002 (has links)
A nivel Nacional las Infecciones Respiratorias constituyen la tasa de morbilidad 8.06% y la tasa de mortalidad 18.6%, 2000. En el Hospital Nacional Hipólito Unanue en el área de Intermedios Servicio de Medicina, las Infecciones Intrahospitalarias, representa la tasa de morbilidad 4.55% y mortalidad 6.25% en el año 2000. El presente estudio refleja la preocupación de las enfermeras por aquellos pacientes que por diversos motivos tienen que permanecer con tubo endotraqueal que si bien es por corto tiempo, no los excluye de adquirir una infección sobreagregada. Frente a esta realidad el personal de enfermería participa como miembro, siendo parte del equipo multidisciplinario, ya que contribuye a medidas preventivas durante la técnica de aspiración de secreciones en pacientes intubados. Es por ello que se plantea la siguiente interrogante ¿Cuáles son los conocimientos y prácticas que tienen las enfermeras en la técnica de aspiración de secreciones en pacientes intubados en la unidad de cuidados intermedios período 2002? La población estuvo conformada por trece enfermeras que laboran en dicha unidad, teniendo en cuenta como objetivo Determinar los conocimientos y prácticas que tienen las enfermeras sobre la aspiración de secreciones en pacientes intubados período 2002. El método utilizado fue descriptivo de corte transversal, las técnicas utilizadas fueron la encuesta y la observación. Los instrumentos aplicados fueron un Cuestionario estructurado y una Lista de Chequeo. Las conclusiones del estudio fueron; el 84% de las enfermeras de la unidad de intermedios poseen un conocimiento "Medio" sobre la aspiración de secreciones en pacientes intubados; según los datos obtenidos a través de un cuestionario. Un gran porcentaje no supieron definir la técnica, ni los objetivos, ni las complicaciones en dicho procedimiento, sin embargo el 100% conocen las barreras de protección, la frecuencia y tiempo por aspiración. El 77% de las enfermeras de la unidad de intermedios realizan una "Buena" práctica en la técnica de aspiración de secreciones en pacientes intubados; según datos obtenidos durante la observación de dicho procedimiento. El 23% de las enfermeras realizan una práctica "Regular" porque antes del procedimiento no realizan la auscultación y evaluación al paciente. / At National level the breathing infections constitute the rate of morbilidad 8.06% and the death rate 18.6%. In the National Hospital Hipolito Unanue in the area of Intermediate medicine service the infections breathing intrahospitalarias the rate of morbilidad 4.55% and mortality 6.25%en the year 2002. The present study reflects the concern of the nurses for those patients that have to remain with tube endotraqueal for diverse reasons that although it is for short time, it doesn't exclude them of acquiring an infection on added. In front of this reality the infirmary personnel participates as miembro, siendo it leaves since of the multidisciplinary team it contributes to preventive measures during the technique of aspiration of secretions in patient intubados. Is it in and of itself that he/she thinks about the following query Which the knowledge are and practical that the nurses have in the technique of aspiration of secretions in patient intubados in the unit of cares intermediate period 2002? The population was conformed by thirteen nurses that work in this unit, keeping in mind as objective to Determine the knowledge and practical that have the nurses on the aspiration of secretions in patient intubados period 2002. The utilized method was descriptive of cross section, the utilized techniques were the survey and the observation. The applied instruments were a structured Questionnaire and a List of Checkup. The summations of the study were; 84% of the nurses of the unit of intermissions possesses a knowledge" Half" on the aspiration of secretions in patient intubados; according to the obtained data through a questionnaire. A great percentage didn't know how to define the technique, neither the objectives, neither the complications in this procedure, however 100% knows the protection barriers, the frequency and time for aspiration. 77% of the nurses of the unit of intermissions carries out a" Good" practice in the technique of aspiration of secretions in patient intubados; according to obtained data during the observation of this procedure. 23% of the nurses carries out a practice" to Regulate" because before the procedure they don't carry out the auscultation and evaluation to the patient.
5

Estudio comparativo de las condiciones de intubación entre la técnica de capacidad vital con sevoflurane al 8% y óxido nitroso al 75% versus propofol, fentanyl y rocuronio

Román Loayza, Eduardo January 2003 (has links)
El presente trabajo es un estudio randomizado, prospectivo, comparativo, que se realizó para comparar las condiciones de intubación que se obtuvieron al hacer la inducción con sevoflurane al 8% y óxido nitroso al 75% versus fentanyl, propofol y rocuronio. Se randomizaron a un total de 60 pacientes para recibir sevoflurane ó propofol para la intubación endotraqueal. A todos los pacientes se les colocó una cánula intravenosa y se pasó entre 5 a 7 ml/kg de suero fisiológico previo a la inducción. A los pacientes que recibieron la técnica de inducción por capacidad vital, se les instruyó en la manera de colaborar, mientras se colocaba una mascarilla para recibir oxígeno al 100% se procedió a hacer el sebado en el circuito con sevoflurane al 8% y óxido nitroso al 75% por aproximadamente 2 minutos, luego se les hizo respirar dicha muestra, hasta la pérdida del reflejo parpebral, momento en el cual se procedió a ventilar manualmente hasta el momento en que se llegue a una concentración espirada de sevoflurane al 6%, procediendo a la intubación endotraqueal. Para el grupo de propofol y rocuronio, se comenzó la inducción con fentanyl de 2.5 ug./Kg., luego de dos minutos se les administró propofol a una dosis de 2 mgs/Kg, en el momento que perdieron el reflejo parpebral se administró rocuronio a 0.9 mgs. Kg y a los 90 segundos se procedió a la intubación endotraqueal. Criterios de relajación mandibular, posición de las cuerdas vocales, y respuesta a la intubación endotraqueal se usaron para evaluar las condiciones de intubación.. Si el score de intubación era menor ó igual a 7 era considerado como aceptable, de otra manera era descrito como condiciones inaceptables de intubación. La intubación endotraqueal fué exitosa en todos los pacientes, en ambos grupos las condiciones de intubación que se presentaron fueron calificadas como excelentes, un paciente de cada grupo presentó cuerdas vocales en movimiento al momento de la laringoscopia y dos pacientes del grupo de propofol y rocuronio presentaron tos y 3 pacientes del grupo de sevoflurane presentó tos, no encontrándose diferencia significativa entre ambos grupos.. Por lo tanto se concluye que la técnica por capacidad vital con sevoflurane al 8% y óxido nitroso al 75% es una buena alternativa para la intubación endotraqueal en adultos.
6

Estudio comparativo de las condiciones de intubación entre la técnica de capacidad vital con sevoflurane al 8% y óxido nitroso al 75% versus propofol, fentanyl y rocuronio

Román Loayza, Eduardo January 2003 (has links)
El presente trabajo es un estudio randomizado, prospectivo, comparativo, que se realizó para comparar las condiciones de intubación que se obtuvieron al hacer la inducción con sevoflurane al 8% y óxido nitroso al 75% versus fentanyl, propofol y rocuronio. Se randomizaron a un total de 60 pacientes para recibir sevoflurane ó propofol para la intubación endotraqueal. A todos los pacientes se les colocó una cánula intravenosa y se pasó entre 5 a 7 ml/kg de suero fisiológico previo a la inducción. A los pacientes que recibieron la técnica de inducción por capacidad vital, se les instruyó en la manera de colaborar, mientras se colocaba una mascarilla para recibir oxígeno al 100% se procedió a hacer el sebado en el circuito con sevoflurane al 8% y óxido nitroso al 75% por aproximadamente 2 minutos, luego se les hizo respirar dicha muestra, hasta la pérdida del reflejo parpebral, momento en el cual se procedió a ventilar manualmente hasta el momento en que se llegue a una concentración espirada de sevoflurane al 6%, procediendo a la intubación endotraqueal. Para el grupo de propofol y rocuronio, se comenzó la inducción con fentanyl de 2.5 ug./Kg., luego de dos minutos se les administró propofol a una dosis de 2 mgs/Kg, en el momento que perdieron el reflejo parpebral se administró rocuronio a 0.9 mgs. Kg y a los 90 segundos se procedió a la intubación endotraqueal. Criterios de relajación mandibular, posición de las cuerdas vocales, y respuesta a la intubación endotraqueal se usaron para evaluar las condiciones de intubación.. Si el score de intubación era menor ó igual a 7 era considerado como aceptable, de otra manera era descrito como condiciones inaceptables de intubación. La intubación endotraqueal fué exitosa en todos los pacientes, en ambos grupos las condiciones de intubación que se presentaron fueron calificadas como excelentes, un paciente de cada grupo presentó cuerdas vocales en movimiento al momento de la laringoscopia y dos pacientes del grupo de propofol y rocuronio presentaron tos y 3 pacientes del grupo de sevoflurane presentó tos, no encontrándose diferencia significativa entre ambos grupos.. Por lo tanto se concluye que la técnica por capacidad vital con sevoflurane al 8% y óxido nitroso al 75% es una buena alternativa para la intubación endotraqueal en adultos. / Tesis de segunda especialidad
7

Lidocaína endovenosa vs. tópica para intubación endotraqueal

Gutiérrez Flores, Julio César January 2004 (has links)
Objetivos: Determinar la eficacia de lidocaina endovenosa vs. Lidocaina tópica, 1mg/k en ambos casos, en la respuesta hemodinámica de la intubación endotraqueal. / Objetivos: Determinar la eficacia de lidocaina endovenosa vs. Lidocaina tópica, 1mg/k en ambos casos, en la respuesta hemodinámica de la intubación endotraqueal. Metodología: Es un ensayo Clínico aleatorizado con grupo control y dos tratamientos. Una muestra de 62 pacientes distribuidos aleatoriamente a tres grupos: control, lidocaina endovenosa, lidocaina tópica. Resultados:La Frecuencia cardiaca (FC) y la Presión Arterial (PS) son los parámetros hemodinámicos más afectados como respuesta a la intubación endotraqueal, produciéndose incrementos de hasta el 30% de la Frecuencia Cardiaca (FC) y 18% de la Presión Arterial (PS) en el grupo control. Para la FC la diferencia fue estadísticamente significativa (p<0.05), al 1er, 2do y 3er minutos, de la intubación entre el grupo control y ambos tratamientos (p<0.05). Para la PS la diferencia fue estadísticamente significativa (p<0.05) entre el control y el grupo de lidocaina tópica al primer y segundo minuto de la intubación; y al tercer minuto de la intubación la diferencia es estadísticamente significativa entre el grupo control y ambos tratamientos. Conclusiones: Lidocaina ha demostrado tener efecto protector tanto en su administración endovenosa como tópica para atenuar la respuesta hemodinámica a la intubación endotraqueal, a dosis de 1 mg/k previo a la intubación endotraqueal. Palabras Clave Intubación orotraqueal – Lidocaina endovenosa – Lidocaina Tópica – Presión Arterial – Frecuencia Cardiaca.
8

Lidocaína endovenosa vs. tópica para intubación endotraqueal

Gutiérrez Flores, Julio César January 2004 (has links)
Objetivos: Determinar la eficacia de lidocaina endovenosa vs. Lidocaina tópica, 1mg/k en ambos casos, en la respuesta hemodinámica de la intubación endotraqueal.
9

Evaluación estadística de pruebas de confirmación de la intubación orotraqueal en emergencia. Servicio de Emergencia de Adultos. Hospital E. Rebagliati. EsSalud. Lima, enero – diciembre 2005

Martínez Bernerdo, Laura Esther, Ortiz Morera, José Carlos Miguel January 2006 (has links)
La mayor complicación de la intubación orotraqueal es no reconocer su adecuada ubicación. La ubicación fuera de la tráquea aumenta la morbilidad y mortalidad en pacientes críticamente enfermos. Por ello, el presente estudio evaluó estadísticamente seis pruebas clínicas y dos dispositivos portátiles la intubación orotraqueal en emergencia. Se estudiaron 52 casos, reclutados en 6 meses en el servicio de emergencia del Hospital Rebagliati, que requerían intubación orotraqueal en emergencia, se distribuyeron equitativamente en 4 grupos en función de los parámetros de sexo y paro cardiorespiratorio. La intubación fue realizada por médicos expertos y se realizó la confirmación en una secuencia protocolizada. Luego de la estabilización del paciente y bajo visualización laringoscópica se colocó otro tubo similar, en sus características, en la tráquea y se repitieron las pruebas de confirmación, con el tubo en el esófago. Con estos datos se obtuvo que ninguna de las pruebas clínicas tienen resultados estadísticos de validez y seguridad para confirmar la posición intratraqueal del tubo después de la intubación orotraqueal en emergencia. Por el contrario, el detector calorimétrico de dióxido de carbono y la prueba de succión por jeringa modificada (dispositivo detector traqueal) tienen resultados estadísticos de validez y seguridad para confirmar la intubación orotraqueal en emergencia, con la diferencia que el primero aplica a los pacientes que no se encuentran en paro cardiorrespiratorio, mientras que el segundo aplica a todos los grupos de estudio. / Trabajo académico
10

Relación entre conocimientos y prácticas del profesional de enfermería sobre los cuidados del tubo endotraqueal en pacientes críticos de UCI Hospital Essalud Huancayo 2012

Velita Rojas, Anamelva January 2014 (has links)
Publicación a texto completo no autorizada por el autor / Determina la relación entre conocimientos y prácticas del profesional de enfermería sobre los cuidados del tubo endotraqueal en pacientes críticos de UCI, Hospital Es Salud Huancayo, 2012. Material y Método. El estudio es de tipo cuantitativo, nivel aplicativo método descriptivo simple de corte transversal. La población estuvo conformada por 22 profesionales de enfermería de UCI, la técnica fue la encuesta y la observación y el instrumento el cuestionario y la lista de cotejo aplicado previo consentimiento informado. Resultados Del 100% (22), 55%(12) conocen, 45% (10) desconocen. En cuanto a la práctica 41%(9) tienen práctica adecuada y 59% (13) inadecuadas. Para establecer la relación se aplicó la prueba del Ji cuadrado a fin de comprobar la hipótesis en el cual se obtuvo que no existe relación entre conocimientos y prácticas. El mayor porcentaje de las enfermeras conocen sobre lo cuidados del tubo endotraqueal en pacientes críticos, seguido de un porcentaje menor que no conocen acerca de cuándo se producen una extubación no programada y la frecuencia de monitorización del balón de neumotaponamiento, y partes del TET.Del mismo modo el mayor porcentaje de los profesionales de enfermería tienen prácticas inadecuadas que está dado por verificar la posición correcta del TET en la placa de Rx, el lavado de manos y la auscultación de campos pulmonares después de la colocación del tubo endotraqueal. Al establecer la relación o comprobar la hipótesis se aplicó Ji cuadrado. / Trabajo de investigación

Page generated in 0.0519 seconds