• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 1
  • Tagged with
  • 9
  • 9
  • 9
  • 5
  • 4
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Transonic interference effects in testing of oscillating airfoils /

Davis, James A. January 1982 (has links)
No description available.
2

Initial investigations of transonic turbine aerodynamics using the Carleton University high-speed wind tunnel /

Jeffries, Michael S. January 1900 (has links)
Thesis (Ph. D.)--Carleton University, 2001. / Includes bibliographical references (p. 254-257). Also available in electronic format on the Internet.
3

Experimental studies of transonic airfoil trailing edge and wake flowfield properties /

Emmer, Deems Shelton January 1984 (has links)
No description available.
4

Turbulence measurements and noise generation in a transonic cryogenic wind tunnel

Griffith, Dwaine O. 21 November 2012 (has links)
A high-frequency combination probe was used to measure dynamic flow quality in the test section of the NASA Langley 0.3-m Transonic Cryogenic Tunnel. The probe measures fluctuating stagnation (total) temperature and pressure, static pressure, and flow angles in two orthogonal planes. Simultaneous unsteady temperature and pressure measurements were also made in the settling chamber of the tunnel. The data show that the stagnation temperature fluctuations remain constant, and the stagnation pressure fluctuations increase by a factor of two, as the flow accelerates from the settling chamber to the test section. In the test section, the maximum rms value of the normalized fluctuating velocity is 0.7 percent. Correlation coefficients l failed to show vortlcity, entropy, or sound as the dominant mode of turbulence in the tunnel. At certain tunnel operating conditions, periodic disturbances are seen in the data taken in the test section. A possible cause for the disturbances is found to be acoustic coupling of the test section and plenum chamber via the perforated side walls in the tunnel. The experimental data agree well with the acoustic coupling theory. / Master of Science
5

EFFECTS OF WALL INTERFERENCE ON UNSTEADY TRANSONIC FLOWS.

PRZYBYTKOWSKI, STANISLAW MACIEY. January 1983 (has links)
Various sources of error can cause discrepancies among flight test results, experimental measurements and numerical predictions in the transonic regime. For unsteady flow, the effects of wind tunnel walls or a finite computational domain are the least understood and perhaps the most important. Although various techniques can be used in steady wind tunnel testing to minimize wall reflections, e.g., using slotted walls with ventilation, wind tunnel wall effects remain in unsteady wind tunnel testing even when they have been essentially eliminated from the steady flow. Even when the walls are ten chord lengths or more from the airfoil being tested, they can have a substantial effect on the unsteady aerodynamic response of the airfoil. In this study we compare numerical computations of two- and three-dimensional unsteady transonic flow with one another, and with experimental measurements, to isolate and examine the effects of tunnel walls. An extension of the time-linearized code developed by Fung, Yu and Seebass (1978) is used to obtain numerical results in two dimensions for comparison with one another and with the experimental measurments of Davis and Malcolm (1980). The steady flow which is perturbed by small unsteady airfoil motions is found numerically by specifying the pressure distribution rather than the airfoil coordinates using the procedure provided by Fung and Chung (1982). This provides results that are nearly free from effects caused by the small perturbation approximation; it also simulates the viscous effects present in the experimental measurements. A similar algorithm, developed especially for this study, is used for the related investigations in three dimensions. Different wall conditions are simulated numerically. Aside from a shift of frequency due to nonlinear effects, our numerical predictions of resonance conditions in two dimensions agree very well with those of linear acoustic theory. A substantial discrepancy between unconfined computations and wind tunnel experiments is observed in the low frequency range. This discrepancy highlights the importance of wall interference and wind tunnel measurements of unsteady transonic flows and delineates the conditions required to suppress them satisfactorily.
6

The measurement of wind tunnel flow quality at transonic speeds

Jones, Gregory Stephen 08 August 2007 (has links)
The measurement of wind tunnel flow quality for the transonic flow regime has been plagued by the inability to interpret complex unsteady flow field information obtained in the free stream. Traditionally hot wire anemometry and fluctuating pressure techniques have been used to quantify the unsteady characteristics of a wind tunnel. This research focuses on the application of these devices to the transonic flow regime. Utilizing hot wire anemometry, one can decompose the unsteady flow field with a three sensor technique, to obtain fluctuations associated with the velocity, density, and total temperature. Implementing thermodynamic and kinematic equations, new methods for expanding the measured velocity, density, and total temperature fluctuations to obtain additional fluctuations are investigated. The derived static pressure fluctuations are compared to the static pressure fluctuations obtained with a conventional fluctuating static pressure probe. The results of this comparison are good, which implies that the individual velocity, density, and total temperature components are time accurate. In the process of obtaining a high quality fluctuating flow field information, it was necessary to evaluate the calibration of the hot wire sensors. A direct calibration approach was compared to a conventional non-dimensional technique. These two calibration techniques should have resulted in the same hot wire sensitivities. There were significant differences in the hot wire sensitivities as obtained from the two approaches. The direct approach was determined to have less errors due to the added heat transfer information required of the indirect approach. Both calibration techniques demonstrated that the velocity and density sensitivities were in general not equal. This suggests that the velocity and density information cannot be combined to form a mass flow. A comparison of several hot wire techniques was included to highlight the errors obtained when assuming that these sensitivities are the same. An evaluation of the free stream flow quality associated with a Laminar Flow Control experiment was carried out in the Langley Research Center 8-Foot Transonic Pressure Tunnel (8' TPT). The facility was modified with turbulence manipulators and a liner that provided a flow field around a yawed super-critical airfoil that is conducive to transition research. These devices are evaluated to determine the sources of disturbances associated with the LFC experiment. / Ph. D.
7

Development of a data reduction method for a high frequency angle probe

Popernack, Thomas G., Jr. 20 November 2012 (has links)
A data reduction method has been developed and tested for a high frequency angle probe. The angle probe is designed for unsteady aerodynamic measurements in transonic cryogenic wind tunnels. The probe measures time-resolved total pressure, static pressure, angle of attack, and yaw angle from readings of four pressure transducers. The unique feature of this probe, as compared to a conventional multi-hole directional probe, is that the four high frequency response silicon pressure transducers are mounted flush on the probe tip. The data reduction method is basically an interpolation routine of calibration curves. The calibration curves consist of experimentally determined non-dimensional flow coefficients. Two experiments were conducted to test the probe and the data reduction method. The first experiment tested the angle probe in a Karman vortex street shed from a cylinder. In the second experiment, the angle probe was placed in an open air jet with an exit Mach number of 0.42. Plots of the time-resolved measurements and the Fast Fourier Transform analysis were made for each test. / Master of Science
8

Development of a transonic turbine cascade facility

Zaccaria, Michael A. January 1988 (has links)
This thesis describes the design and initial testing of a transonic turbine cascade facility. It is specifically concerned with the best way to obtain flow periodicity and repeatability through the cascade by the use of tailboards at the cascade exit. The problem of how to achieve flow periodicity and repeatability has not been completely resolved. An examination of the literature available on transonic turbine cascade testing indicates some researchers use no tailboards, some use a solid tailboard, and still others use a porous tailboard. In this thesis, the flow through the turbine cascade is tested for three different cascade exit configurations; no tailboard, a solid tailboard, and a porous tailboard. The cascade is also tested with the tailboard at different angles, to see what effect the angle of the tailboard has on the flow through the cascade. The data acquisition and flow visualization systems are discussed and some preliminary results are given. / Master of Science
9

Dynamic flow quality measurements in a transonic cryogenic wind tunnel

Rosson, Joel Christopher January 1985 (has links)
Two instruments mounted in a piggyback arrangement were developed for time-resolved measurements of dynamic flow quality in a transonic cryogenic wind tunnel. The first one is a dual hot-wire aspirating probe for measurement of stagnation pressure and temperature. The second is a miniature high-frequency response angle probe consisting of surface mounted pressure sensors. The aspirating probe was tested in the 0.3-m Transonic Cryogenic Tunnel (TCT) at NASA-Langley Research Center. Stagnation pressure and temperature measurements were taken in the free-stream of the settling chamber and test section. Data were also obtained in the unsteady wake shed from an airfoil oscillating at 5 Hz. The investigation revealed the presence of large stagnation pressure and temperature fluctuations in the settling chamber occurring at the blade passing frequency of the tunnel driving fan. The fluctuations in the test section are of a much more random nature and have amplitudes much lower than those in the test section. The overall results are consistent with previous tunnel disturbance measurements in the 0.3-m TCT. In the unsteady wake shed from the oscillating airfoil, stagnation temperature fluctuations as high as 42 K rms were observed. The high-frequency angle probe is a four sensor, pyramid type probe capable of simultaneously measuring time resolved stagnation and static pressures and two orthogonal flow angles. Using measurements from both probes, all flow parameters of interest can be deduced. Aerodynamic behavior of a full size model of the probe was established in an open air jet of known conditions. / M.S.

Page generated in 0.0946 seconds