• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 193
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 1
  • Tagged with
  • 197
  • 197
  • 107
  • 99
  • 93
  • 84
  • 80
  • 41
  • 31
  • 31
  • 27
  • 25
  • 25
  • 25
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Tratabilidade de esgoto sanitario contendo formaldeido em um sistema combinado filtro anaerobio-biofiltro aerado submerso / Treatability of domestic wastewater containing folmaldehyde in a combined system anaerobic filter and biological aerated filter

Castagnato, Renata 29 August 2006 (has links)
Orientador: Edson Aparecido Abdul Nour / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-11T03:49:57Z (GMT). No. of bitstreams: 1 Castagnato_Renata_M.pdf: 1224635 bytes, checksum: 513cfc1c14b5af1159379a00e5d00297 (MD5) Previous issue date: 2006 / Resumo: O formaldeído é um composto orgânico muito utilizado em diversos setores da indústria e serviços de saúde. Em hospitais e laboratórios de anatomia, ele é empregado em solução de 8 a 10 %, que ao se tornar imprópria para uso, necessita ser disposta adequadamente para não afetar os ecossistemas presentes nos corpos d¿água ou nos processos biológicos das estações de tratamento de esgotos. Pois, dependendo da concentração que o formaldeído se encontra, pode ser extremamente tóxico. O presente estudo teve o objetivo de verificar a tratabilidade de esgoto sanitário contendo formaldeído em um sistema combinado composto de um filtro anaeróbio (FA) seguido de um biofiltro aerado submerso (BAS). O volume útil de cada reator era de 17,6 L e o tempo de detenção hidráulica de 12 h. As concentrações de formaldeído aplicadas ao esgoto sanitário afluente ao sistema foram de 50, 100, 200 e 400 mg L-1, dividas em quatro fases de operação. Durante o monitoramento do sistema, foi verificado que a eficiência de remoção de formaldeído variou de 85,0 a 99,4 %, sendo que a partir do início da segunda fase (quando a concentração aplicada era de 100 mg L-1), a média de remoção foi de 98,0 ± 1,2 %. A média de remoção de DQO, durante as quatro fases de aplicação, foi de 84,4 ± 7,3 %, apesar do formaldeído não ter sido a única fonte de carbono. O valor máximo de carga de formaldeído removida no sistema foi de 0,407 kgm-3 d-1, quando sua aplicação no esgoto bruto era de 0,411 kg m-3 d-1 (concentração de 410,8 mg L-1). Foi observado também que a maior concentração de formaldeído encontrada no efluente tratado pelo sistema foi de 5,8 mg L-1, com valor médio de 1,9 ± 1,4 mg L-1. Houve inibição do processo de nitrificação no BAS a partir de 50 mg L-1 de formaldeído presente no esgoto afluente. Verificou-se que o sistema proposto foi adequado ao tratamento de esgoto sanitário com formaldeído, pois em todas as concentrações do composto aplicado (0 a 410,8 mg L-1), o seu desempenho se manteve estável, principalmente com relação à remoção de DQO e do próprio formaldeído. Palavras-chave: Formaldeído, sistema combinado anaeróbio/aeróbio, filtro anaeróbio, biofiltro aerado submerso, nitrificação, esgoto sanitário / Abstract: Formaldehyde is an organic compound largely used in several industrial sectors and health services, for example in hospitals and anatomy laboratories in a proportion of 8 to 10 %. When it becomes inadequate to be used, this solution must be properly disposed in order not to affect the ecosystems in water streams or in the biological process in the treatment sewage works, because depending on its concentration it can be extremely toxic. This study aims to verify the treatability of domestic wastewater containing formaldehyde in a combined system formed by an Anaerobic Filter followed by a Biological Aerated Filter. Each reactor presented a volume of 17,6 l and 12 h of hydraulic retention time (HRT). This type of system aggregates the advantages of these combined processes: anaerobic and aerobic. The concentration of formaldehyde used in domestic wastewater influent in the system was divided into 4 phases of operation, which corresponded to 50, 100, 200 and 400 mg L-1. The efficacy of removal of formaldehyde in the system varied from 85,0 and 99,4 %, and it must be noted that from the beginning of the 2nd phase (100 mg L-1) the average of removal was 98,0 ± 1,2 %. The average of removal of COD, during the whole 4 phases of operation, was 84,4 ± 7,3 %. It must be said that formaldehyde was not the only carbon source. The removal rate of formaldehyde achieved a maximum of 0,407 kg m-3 d-1, when the applied rate in the system was 0,411 kg m-3 d-1. This fact happened when the concentration of aldehyde in the influent was 410,8 mg L-1. The maximum concentration verified of formaldehyde in the effluent of system was 5,8 mg L-1, with an average of 1,9 ± 1,4 mg L-1. The process of nitrification has been inhibited in the Biological Aerated Filter from 50 mg L-1 of formaldehyde present in the influent. The proposed system was adequate to the treatment of domestic wastewater plus formaldehyde because in all concentration of aldehyde applied (0 a 410,8 mg L-1) its performance was kept stable, mainly in relation to COD removal and formaldehyde itself. Key words: Formaldehyde, combined system anaerobic/aerobic, anaerobic filter, biological aerated filter, nitrification, domestic wastewater / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
172

Biossorção de cádmio por linhagens de Aspergillus sp / Biosorption of cadmium by Aspergillus sp. strains

Ana Paula de Souza Pallu 11 April 2006 (has links)
Os metais pesados representam o maior resíduo industrial contaminante de solos, plantas e animais no ecossistema, causando graves efeitos tóxicos ao homem principalmente devido a sua ampla distribuição no ambiente, que tem sido intensificado pela industrialização. Um dos metais pesados mais tóxicos é o cádmio, elemento bastante utilizado em processos industriais, o que o torna um importante contaminante ambiental. Pesquisadores preocupados com problemas associados à poluição ambiental por metais pesados iniciaram estudos com técnicas de biorremediação utilizando microrganismos explorando a capacidade desses na remoção de íons tóxicos do ambiente, dentre eles os fungos. Dentre os vários processos utilizados na remediação do cádmio dos efluentes industriais, um dos mais promissores é a biossorção. Essa técnica tem por base a propriedade dos metais se ligarem a vários materiais biológicos, tais como algas, leveduras, fungos, bactérias e plantas; para retenção, remoção ou recuperação de metais pesados de um ambiente líquido. Dentro desse contexto o fungo Aspergillus sp. foi estudado quanto à sua capacidade de biossorção de cádmio. As pesquisas com Aspergillus sp. demonstram que linhagens dessa espécie possuem grande resistência ao cádmio. No presente trabalho foram avaliados parâmetros para a biossorção de cádmio em soluções artificiais com a utilização de biomassa de duas linhagens do fungo Aspergillus sp. (MSE e CadG1). Dentre estes parâmetros, foram avaliados capacidade de biossorção do micélio em diferentes condições fisiológicas do fungo (biomassa viva ou morta), tempo de residência ideal (0, 4, 8 e 12 horas) para as concentrações de sal de cádmio de 20, 40, 60, 80 e 100 mg.L-1 e os valores de pH 4,0, 7,0 e 10,0 da solução de sal de cádmio. Futuramente, estas linhagens deverão passar por programas de melhoramento genético para uma otimização da eficiência da biossorção. A linhagem MSE mostrou-se superior à linhagem CadG1 em relação a biossorção de cádmio. As biomassas viva e morta não apresentaram diferença estatística significativa entre as médias de biossorção, mostrando que ambas podem ser utilizadas com a obtenção de resultados de biossorção semelhantes, no entanto, na interação entre todos os fatores, os estados fisiológicos diferiram estatisticamente, sendo que a maioria apresentou maiores índices de biossorção de cádmio com a biomassa morta. O tempo de residência que apresentou melhor eficiência foi o de 4 horas para a linhagem MSE e o de 12 horas para a linhagem CadG1. A biossorção é maior, em valores absolutos, quanto maior é a concentração de cádmio na solução e menor, em valores percentuais, quanto maior essa concentração. O pH ótimo para o processo de biossorção é o 7 nas condições avaliadas. / The heavy metals represent the major industrial residues contaminant of soils, plants and animals in the ecosystems, causing a toxic effect to humans, mainly due to the wide spread distribution in environment which is intensified by industrialization process. One of most toxics heavy metals is cadmium, commonly used in industrial process, what make it an important environmental contaminant. Researchers looking at to problems linked to environmental pollution by heavy metals have been studied bioremediation techniques using microorganism, among them, the fungi, exploring their ability in to remove toxic ions from environment. Form various remediation techniques used for cadmium in industrial effluents, the most promising is the biosorption. This methodology is based in the heavy metals linkage to biologic material, like algae, yeasts, fungi, bacteria or plant, to retention, removing or recovery of heavy metals from liquid environment. In this context, Apergillus sp. was studied for it ability to biosorption of cadmium. Previous studies with Aspergillus sp. have revealed that strains from this species have a great resistance to cadmium. In the present work were evaluated parameters for biosorption of cadmium in artificial solutions, using two strains of Aspergillus sp. Among evaluated parameters, there were ability to biosorption of mycelia in different physiological condition (viable or nonliving), ideal residence period (0, 4, 8 and 12 hours) in cadmium salt concentrations of 20, 40, 60, 80 e 100 mg.L-1 and the pH values of 4,0, 7,0 and 10,0. In the future such strains must be applied in genetic breeding programs, to optimize the efficiency in cadmium biosorption. The MSE strain revealed to be better than CadG1 strain for cadmium biosorption. Bioamass live and death do not presented statistical differences between values of biosorption, suggesting that both can be used with satisfactory results for cadmium biosorption. However, studying interactions among all factors, physiological state differ statistically, where the most of them presented bigger indices of cadmium biosorption for usage of death biomass. The best residence period was 4 hours in MSE e 12 hours in CadG1. The biosorption was bigger, in absolute values, as bigger is the cadmium concentration in solution and minor in percentual values, as bigger is this concentration. The best pH for biosorption process is 7,0.
173

Desinfecção de esgotos com radiação ultravioleta : influencia da qualidade do efluente e da fotorreativação

Pires, Marco Roberto 24 June 2002 (has links)
Orientador: Jose Euclides Stipp Paterniani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-02T03:02:10Z (GMT). No. of bitstreams: 1 Pires_MarcoRoberto_D.pdf: 5271302 bytes, checksum: 360fb9a15e870769155cec24f76d1dab (MD5) Previous issue date: 2002 / Resumo: Desinfecção de esgotos com radiação ultravioleta vem sendo utilizado, principalmente, em países europeus e nos EUA. A fotorreativação dos microrganismos tem sido avaliada para determinar seu grau de interferência na desinfecção. Este trabalho teve como objetivo avaliar a radiação ultravioleta para diferentes qualidades de efluentes e estudar a fotorreativação. Foram utilizados dois reatores diferentes, sendo um com lâmpadas emersas e outro imersa. Os reatores foram testados em seis efluentes diferentes para quatro vazões diferentes para cada reator. Os coliformes totais e fecais foram analisados para avaliar a eficiência dos reatores. Ensaios de fotorreativação em condições controladas foram realizadas. De forma geral, o Reator I foi mais eficiente que o Reator TI, e a qualidade do efluente muitas vezes foi mais importante que a dose aplicada como apresentada no Ponto de Coleta 3 para coliformes fecais, em que a inativação foi maior para a vazão 4 (com menor tempo de exposição à luz) em vez de ocorrer para a vazão 1 (com maior tempo de exposição). Doses de radiação ultravioleta mais altas implicam em valores iniciais e finais de fotorreativação menores, porém para atingir o valor máximo necessita de mais tempo. Quanto maior a dose de radiação ultravioleta aplicada menor é o grau de fotorreativação; os coliformes totais tem melhor correlação para análises desta natureza quanto comparado com a E.co/i / Abstract: Disinfection of effluents with ultraviolet radiation has been used in Europeans countries and United States. The photoreactivation of microorganism have been estimated to determine the influence on the disinfection. The objective of this work had to evaluate the ultraviolet disinfection to different qualities of effluent and photoreactivation. Two different kinds of reactors were used in experimental analyzed. The reactors were tested to six different effluents for four flows. Total and fecal coliforms were analyzed to estimate the efficiency of reactors. Assays of photoreactivation were analyzed in controlled conditions. In most of case, the Reactor I was more efficient than Reactor II, and effluent quality was more important than the dose uv applied. Dose uv higher imply in initial and final values of lower photoreactivation. The total coliforms have better correlation than E.coli / Doutorado / Saneamento e Ambiente / Doutor em Engenharia Civil
174

Proposição, implantação, partida e ajustes de reatores biologicos e fisico-quimicos para tratamento e reciclagem de efluentes de lavadores de veiculos em escala real / Proposition, start and adjust of biological and physiochemical reators for treatment and recycling of carwash effluent in real scale

Magalhães, Aléx Fabiano Ribeiro de 17 February 2005 (has links)
Orientador: Carlos Gomes da Nave Mendes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-04T11:01:23Z (GMT). No. of bitstreams: 1 Magalhaes_AlexFabianoRibeirode_M.pdf: 2242026 bytes, checksum: b4ae2e107eb7317d892ade5a7815f862 (MD5) Previous issue date: 2005 / Resumo:Com a intenção de preencher a lacuna decorrente de poucos estudos sobre o tratamento de efluentes da lavagem de veículos, na presente pesquisa, propõe-se um sistema de tratamento composto de biofiltros aerados submersos seguidos por flotação por ar dissolvido na remoção dos principais contaminantes contidos nos mesmos. Para isso, foi concebida, instalada e operada uma instalação protótipo em escala real, visando possibilitar a reutilização do efluente tratado. O sistema foi montado em uma transportadora e destinado ao tratamento dos efluentes de lavagens de caminhões tipo baú através de lavador tipo ¿rollover¿. Apesar de terem sido previstos três meses para a operação do sistema, vários problemas de origem operacional do próprio lavador de veículos impediram a realização dos testes de longa duração. Mesmo assim, o período de testes foi útil para estabelecer-se quais alterações físicas deveriam ser incorporadas à instalação proposta para a solução de diversos problemas específicos relativos à concepção original do sistema, subsidiando dados para a otimização de futuros sistemas a serem implantados em escala real. Concluiu-se que, após as modificações introduzidas, tais como a alteração de dispositivos de entrada e saída dos reatores, substituição de acessórios de controle de pressão e vazão, entre outros, a alternativa proposta para tratamento e reúso deste tipo de efluente é plenamente viável / Abstract: With the intention to contribute for aim of filling out the emptiness provoked by few studies on the treatment of carwash affluent, in this research, it intends to create a treatment system composed of aerated submerged biological filter (BAS) following for the dissolved air flotation (FAD) on the removal of the main pollutants present in this effluent type. For that, it was become designed, installed and operated an installation prototype in real scale, seeking the water recycling. The system was installed at cargo transport interprise and destined to the treatment of the carwash effluent type "rollover". In spite of it have been preview three months for the operation time of the system, several operational problems of the washer accomplish of the long time tests. Even so, the time of tests was useful to establish which physical alterations should be incorporate in the installation proposed for the solution of problems to the original conception of the system, subsidizing data for the otimization of the future systems to be implanted in real scale. This research was finish, after the modifications, such as the alteration of inlet and outlet devices of the reactors, pressure and flow control, among other, the proposal alternative for treatment and reuse of rollover type carwash effluent type is fully viable / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
175

Avaliação citogenotóxica de efluente têxtil tratado por processo biológico e físicoquímico

SOUZA, Vanessa Cristina de 14 March 2017 (has links)
Nome completo da orientadora: Sávia Gavazza dos Santos Pessôa / Submitted by Pedro Barros (pedro.silvabarros@ufpe.br) on 2018-09-27T20:56:36Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Vanessa Cristina de Souza.pdf: 1406576 bytes, checksum: d69d5efbca1f6e94b6d883eae0129129 (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-11-20T18:48:48Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Vanessa Cristina de Souza.pdf: 1406576 bytes, checksum: d69d5efbca1f6e94b6d883eae0129129 (MD5) / Made available in DSpace on 2018-11-20T18:48:48Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Vanessa Cristina de Souza.pdf: 1406576 bytes, checksum: d69d5efbca1f6e94b6d883eae0129129 (MD5) Previous issue date: 2017-03-14 / As indústrias têxteis são grandes poluidoras do meio ambiente devido aos processos industriais realizados, como enxágue, tingimento, fixação e alvejamento. No Brasil, principalmente no Nordeste, comumente são lançados efluentes têxteis em corpos d’água, sem qualquer tratamento, gerando grandes impactos ambientais. Este trabalho visou analisar o potencial tóxico, citotóxico, genotóxico e mutagênico em nível cromossômico de efluentes têxteis brutos e após tratamento físico-químico ou biológico, mediante sistema-teste Allium cepa. Adicionalmente, foi realizado o teste de ecotoxicidade com Vibrio fischeri. Para tal, foram realizados dois experimentos, Experimento 1, realizado com efluentes têxteis reais brutos e após tratamento físico-químico oriundos de uma lavanderia têxtil localizada na cidade de Caruaru-PE e, Experimento 2, realizado com efluentes sintéticos brutos e após tratamentos biológicos oriundos de reatores em escala de bancada operados no laboratório de saneamento ambiental (LSA) do Campus da UFPE em Recife. Para os efluentes reais (Experimento 1), não foi observada toxicidade nem para o efluente bruto nem para o tratado físico-quimicamente em ambos os bioensaios (A. cepa e V. fischeri). Além disso, o tratamento físico-químico apresentou eficiência de remoção de cor de 64,1%. Para os efluentes sintéticos, houve remoção de cor, em 77,1% e 75%, e de DQO, em 76,7% e 81,1%, respectivamente para o TAN (Tratamento Anaeróbio) e TAI (Tratamento Aeróbio Intermitente). Nas análises com A. cepa, verificou-se aumento do índice de genotoxicidade (IGen) de 63,3% e 52,1% para o efluente bruto sintético (BS) e TAN, respectivamente, bem como redução de 65% para o TAI, quando comparado ao controle negativo. Análises com V. fischeri corroboraram as análises físico-químicas e com o sistema-teste A. cepa, pois, foi encontrada toxicidade para as amostras de TAN, mas não de TAI. Esses resultados mostram a importância em unir dois ou mais processos de tratamento a fim de se ter uma melhor eficiência nos resultados bem como melhor qualidade do efluente lançado nos corpos hídricos. / The textile industries are great environment polluters due to industrial processes realized, like washing, coloring, fixation and bleaching. In Brazil, mainly in Northeastern region, textile effluents are disposed directly in bodies of water with no previous treatment, generating large environmental impacts. In this work, we evaluate the toxic, cytotoxic, genotoxic and mutagenic potential at a chromosome level, testing the effects of real and synthetic textile effluents treated by physicchemical and biological processes, by Allium cepa test system. Additionally, it was conducted a test of ecotoxicity with Vibrio fischeri. To the real effluents, it was not observed toxicity for the raw or treated effluents in both tests (A. cepa and V. fischeri). Moreover, the physic-chemical treatment showed an efficiency in color removal of 64,1%. For the synthetic wastewaters physic-chemical treatments, there was a positive color removal, in the order of 77,1% and 75%, and COD reduction in the order of 76,7% for the TAN (Anaerobic Treatment) a and 81,1% TAI (Aerobic Intermittent Treatment). The analysis with A. cepa showed an increase on the genotoxicity index (IGen) of 63,3% and 52,1% for the crude synthetic effluent (BS) and, respectively, as well as the reduction on 65% for TAI in comparison to the negative control. The analysis with V. fischeri confirms the physic-chemical analysis with the A. cepa systems, once it was found toxicity for the TAN samples, but not for TAI. These results point out the need to aggregate two or more effluent treatments in order to gather a better efficiency, as well as a better quality on the wastewater disposed on bodies of water.
176

Otimização do tratamento de águas oleosas com alto grau de emulsificação utilizando biossurfactante e flotação por ar dissolvido (fad).

Lins, Josiane Maria de Santana Melo 23 March 2017 (has links)
Submitted by Biblioteca Central (biblioteca@unicap.br) on 2018-02-15T18:24:07Z No. of bitstreams: 1 josiane_maria_santana_melo_lins.pdf: 1259298 bytes, checksum: 8d95f0beebff539982987b6fe3f33c38 (MD5) / Made available in DSpace on 2018-02-15T18:24:07Z (GMT). No. of bitstreams: 1 josiane_maria_santana_melo_lins.pdf: 1259298 bytes, checksum: 8d95f0beebff539982987b6fe3f33c38 (MD5) Previous issue date: 2017-03-23 / Residual Frying Oil (RFO) is part of one of the waste generated daily in households, industries and voluntary delivery points (public and mixed-economy companies). The uncontrolled disposal of residues of frying oils, in sinks or dumped directly into bodies of water, entails a series of environmental damages, such as obstruction of pipes in sewage systems and increased costs of treatment processes, in addition to Increased pollution. The collection and reuse of these waste oils prevents them from being disposed of inappropriately and benefits the environment. The percentage recovery of residual oil from fried foods depends to a large extent on the washing operations. These operations are also responsible for the effective separation of the organic and aqueous phases from the emulsions generated so as to obtain a lower possible oil content in the aqueous phase, while the oil can still be used for reuse in the soap and detergent production processes. In this work, actions were taken to improve the operational conditions to improve the process of chemical washing of the ORF by cleaning products industries, in order to generate an adequate effluent for subsequent physical-chemical treatment by Dissolved Air Flotation (DAF). After conditioning, the OFR collection vessel was rinsed with steam and received addition of chemical reagents (HCLO3, NaOH and NaCl). The material was then treated through DAF, with a biosurfactant acting as a biodegradable manifold, in a laboratory scale prototype operating in continuous mode. The experiments were performed according to a Central Composite Designs (CCD) of type 22. As factors, the ratio between the effluent flow to be treated and the biosurfactant flow rate (X1) was used, and the ratio of the air flow to the effluent flow recirculated to produce the microbubbles (X2). As a response variable the water-oil separation efficiency was used. A maximum separation efficiency of 98.0% for X1 and X2 values equal to 1.0.103 and 1.05.104, respectively. / O Óleo de Fritura Residual (OFR) é parte de um dos resíduos gerados diariamente em residências, indústrias e pontos de entrega voluntários (empresas públicas e de economia mista). A eliminação descontrolada de resíduos de óleos de fritura, em sumidouros ou jogados diretamente em corpos d’água, acarreta uma série de danos ambientais, tais como a obstrução de tubos em sistemas de esgotos e o aumento dos custos dos processos de tratamento, além do aumento da poluição. O recolhimento e a reutilização desses óleos usados impede o seu descarte inadequado e traz benefícios para o ambiente. A percentagem de recuperação de óleo residual proveniente de alimentos fritos depende, em grande parte, das operações de lavagem. Estas operações são também responsáveis pela separação efetiva das fases orgânicas e aquosa das emulsões geradas, de forma a se obter um menor teor de óleo possível na fase aquosa, enquanto que o óleo possa ainda ser utilizada para reúso nos processos produtivos de sabões e detergentes. Neste trabalho, foram realizadas ações para melhorar as condições operacionais de aprimoramento do processo de lavagem química do ORF por indústrias de produtos de limpeza, a fim de gerar um efluente adequado para posterior tratamento físicoquímico por Flotação de Ar Dissolvido (FAD). Depois de acondicionado, o recipiente de coleta de OFR foi lavado com vapor e recebeu adição de reagentes químicos (HCLO3, NaOH e NaCl). O material foi então tratado através de FAD, com um biossurfactante atuando como um colector biodegradável, num protótipo de escala laboratorial operando em modo contínuo. Os experimentos foram realizados de acordo com um Delineamento Composto Central Rotacional (DCCR) do tipo 22. Como fatores utilizou-se a razão entre a vazão do efluente a ser tratado e a vazão de biossurfactante (X1), e a razão entre a vazão de ar e a vazão de efluente recirculada para produzir as microbolhas (X2). Como variável resposta utilizou-se a eficiência de separação água-óleo. Uma eficiência máxima de separação de 98,0 % para valores de X1 e X2 iguais a 1,0.103 e 1,05.104, respectivamente.
177

Tratabilidade de águas residuárias contendo poluentes perigosos: estudo de caso. / Treatability of hazardous industrial wastewater: case study.

Morita, Dione Mari 29 September 1993 (has links)
O trabalho foi desenvolvido com o objetivo de caracterizar e estudar formas de tratamento de águas residuárias de indústrias de refino de óleo lubrificante e de recuperação de solventes. A fase preliminar teve por objetivo avaliar a biodegradabilidade do despejo combinado dessas duas indústrias. A segunda foi realizada em instalação piloto composta, basicamente, de uma unidade de arraste com ar/tanque de equalização, tanques de correção de pH e de aeração com tempos de detenção distintos, seguidos de tanques de sedimentação. Foram executados testes para avaliar a remoção de material solúvel em n-hexano do despejo da indústria de refino de óleo lubrificante e do efluente final. A unidade de arraste com ar difuso operando com subpressão de 15 mmhg a saída dos gases, vazão específica de ar de 20 ml/l min. E tempo de detenção de 5 dias foi eficiente na remoção de acetona, piridina, benzeno, tolueno, hexano, metil etil cetona e provavelmente solventes clorados. Não apresentou remoção significativa de álcoois, que foram eficientemente degradados no sistema biológico subsequente. Obteve-se remoções superiores a 90%, em termos de dbo e dqo, no processo biológico com tempos de detenção de 20 e 30 dias, e em torno de 80% para os demais. Os sistemas biológicos responderam bem as cargas transientes de solventes, exceto para o tolueno e o álcool isopropílico. / Traditionally, raw materials from solvent recovery and from reclaimed lubricating oil industries are considered hazardous solid waste. Consequently, the best control technology is incineration. This work was developed in order to characterize and to study ways of treating wastewaters from lubricating oil refinery and solvent recovery industries. The experimental part was divided in two phases. The preliminar step aimed to evaluate the biodegradability of combined wastewater from both industries. The second phase was basically carried out in a pilot plant composed by an air stripping unit/equalization tank, pH correction tanks and bioreactors with different retention times, followed by sedimentation tanks. Other than these assays, tests were performed to evaluate the removal of soluble material in n-hexane of the wastewater of the lubricating oil refinery industry and of the supernatant of the sedimentation tank after the bioreactor of 20 days retention.The buble aeration unit operating with a 15 mmHg suppresion to the gas exit, with a specific air flow of 20 mL/L.min. and with a retention time of 5 days was efficient to remove acetone, pyridine, benzene, toluene, hexane, methyl ethyl ketone and probably chlorinated solvents. There was no significative removal of alcohols, that were efficiently degraded in the subsequent biological system. BOD and COD removal efficiencies were better than 90% in the biological process with retention times of 20 and 30 days, and about 80% for the rest. The responses of biological systems to the transient inputs of solvents were well, except for toluene and isopropilic alcohol. Several physico-chemical processes for soluble material in n-hexane removal were studied. The only one to present effluent concentration under the legal limit was the addition of the sodium xylene-sulphonate base demulsifier to the supernatant of the sedimentation tank the bioreactor of 20 days retention.
178

Eficácia do tratamento biológico em gotejadores operando com água residuária doméstica tratada / Effectiveness of biological treatment in drippers operating with domestic wastewater treated

Costa, Danniely de Oliveira 28 August 2014 (has links)
Made available in DSpace on 2016-08-16T13:31:37Z (GMT). No. of bitstreams: 1 DannielyOC_DISSERT.pdf: 2303659 bytes, checksum: 0a8a4e23e67c6b7ec7713ce05f41d2e4 (MD5) Previous issue date: 2014-08-28 / Water scarcity and environmental degradation in semiarid region are factors that increase the use of treated domestic wastewater aiming its agricultural use. The drip irrigation becomes more sustainable method for this purpose, due to high application efficiency and low risk of contamination of agricultural produce and operators in the field. However, they have a high susceptibility of obstruction the emitters, particularly when operating with wastewaters, because of the biofouling's formation. In this context, the present study seeked to employ biological treatment aimed at the drippers' unblocking that operate with treated domestic wastewater. For that, we assembled an experimental bench in the Experimental Unit for Water Reuse (EUWR), which has a total area of 793.13 m2, installed on the Zoo and Botanical Park located at the Universidade Federal Rural do Semi-Árido (UFERSA), Mossoró campus. To assessment of hydraulic performance and clogging of three types of drippers applying wastewater treated for 400 h, was mounted an experiment with four irrigation units, equipped with three types of emitters (G1, G2 and G3), with three replicates (three lateral lines by type of dripper). Every 80 h of operation evaluated the CUC, CUD, Us, CVQ, RQR and Q. After the operation time of 400 h, was held the second experiment, characterized by the use of biological treatment that consisted of catalyst enzymatic brand Byosol Swift, line FA (Aseptic Fosse) and powder concentrate of bacteria MaxBio brand, used together . The experiment was mounted with three factors, being the first factor the three types of emitters, the second factor the three treatments T1 (without application of the product), T2 (first application of the product) and T3 (second application of the product) and the third factor the dosages DOS1 (80 mg L-1), DOS2 (160 mg L-1), DOS3 (240 mg L-1) and DOS4 (320 mg L-1) the product MaxBio in three replicates (three lateral lines by type of dripper in each irrigation unit). The data were submitted to analysis of simple and multiple regression, mean test and parametric Pearson correlations test. The results indicated that the formation of biofouling resulting from the interaction between the physical, chemical and biological agents led to partial and total clogging of emitters and hence reduction in the hydraulic performance of irrigation units which operate with domestic wastewater treated. The dripper G1 was more susceptible to clogging than the drippers G2 and G3. In dripper G1, the dosage of 80 mg L-1 MaxBio showed more positive results, as the recovery of hydraulic performance, this being more expressive effect with the completion of the second application of the product. A dosage of 80 mg L-1 MaxBio also showed the best results in clearing the dripper G3, the first application of the product is required, only / A escassez hídrica e a degradação ambiental no semiárido são fatores que potencializam a utilização de águas residuárias domésticas tratadas visando seu aproveitamento agrícola. A irrigação localizada torna-se o método mais sustentável para este fim, devido à elevada eficiência de aplicação e do baixo risco de contaminação do produto agrícola e de operadores no campo. No entanto, apresentam alta susceptibilidade ao entupimento de emissores, particularmente quando operam com águas residuárias, em função da formação de bioincrustação. Neste contexto, o presente trabalho teve por objetivo empregar o tratamento biológico visando à desobstrução de gotejadores que operam com água residuária doméstica tratada. Para isso, foi montada uma bancada experimental na Unidade Experimental de Reuso de Água (UERA), a qual apresenta uma área total de 793,13 m2, instalada no Parque Zoobotânico da Universidade Federal Rural do Semi-Árido (UFERSA), campus Mossoró. Para avaliação do desempenho hidráulico e do entupimento dos três tipos de gotejadores aplicando água residuária tratada, durante 400 h, montou-se um experimento com quatro unidades de irrigação, dotadas de três tipos de gotejadores (G1, G2 e G3), em três repetições (três linhas laterais por tipo de gotejador). A cada 80 h de funcionamento avaliou-se o CUC, CUD, Us, CVQ, RQR e Q. Decorrido o tempo de operação de 400 h, realizou-se o segundo experimento, caracterizado pelo emprego do tratamento biológico que constou de catalisador enzimático da marca Byosol Swift, linha FA (Fossa Asséptica) e de pó concentrado de bactérias da marca MaxBio, utilizados conjuntamente. O experimento foi montado com três fatores, sendo o primeiro fator os três tipos de gotejadores, o segundo fator os três tratamentos T1 (sem aplicação do produto), T2 (1ª aplicação do produto) e T3 (2ª aplicação do produto) e o terceiro fator as dosagens DOS1 (80 mg L-1), DOS2 (160 mg L-1), DOS3 (240 mg L-1) e DOS4 (320 mg L-1) do produto MaxBio, em três repetições (três linhas laterais por tipo de gotejador em cada unidade de irrigação). Os níveis de desobstrução dos gotejadores pelos produtos biológicos foram avaliados. Os dados foram submetidos às análises de regressão simples e múltipla, teste de média e teste de correlações paramétricas de Pearson. Os resultados indicaram que a formação de bioincrustação resultante da interação entre os agentes físico-químicos e biológicos propiciou o entupimento parcial e total dos gotejadores e, consequentemente, redução no desempenho hidráulico das unidades de irrigação que operaram com água residuária doméstica tratada. O gotejador G1 foi mais suscetível ao entupimento do que os gotejadores G2 e G3. No gotejador G1, a dosagem de 80 mg L-1 de MaxBio apresentou resultados mais positivos, quanto à recuperação do desempenho hidráulico, sendo este efeito mais expressivo com a realização da segunda aplicação do produto. A dosagem de 80 mg L-1 de MaxBio, também, apresentou os melhores resultados na desobstrução do gotejador G3, sendo necessária, apenas, a primeira aplicação do produto
179

A influência da salinidade nos processos de tratamento de efluentes por lodos ativados. / The influence of salinity in wastewater treatment processes by activated sludge.

Luciana Silva dos Santos 07 March 2012 (has links)
O processo de tratamento de efluentes por lodos ativados é um dos processos de tratamento mais difundido em todo o mundo, devido principalmente a qualidade do efluente obtido. Entretanto, trata-se de um processo biológico dependente da atividade bacteriana para a estabilização da matéria orgânica proveniente dos esgotos e com isso, se faz necessária a manutenção das condições ideais para a sobrevivência e proliferação das bactérias e dos outros microrganismos envolvidos neste processo. Efluentes salinos causam um grande distúrbio na atividade celular dos microrganismos presentes neste processo. A análise biológica do lodo e a taxa de consumo de oxigênio são testes rápidos, práticos, baratos e sem geração de resíduos químicos e que foram adotados neste trabalho para acompanhar a eficiência do processo. Esses dois parâmetros são amplamente utilizados em pesquisas, porém ainda é sub-utilizado para efetivo monitoramento de Estações de Tratamento de Esgotos. Este presente trabalho investigou a influência da salinidade nos processos de lodos ativados através de parâmetros que levam em consideração a atividade metabólica dos organismos aeróbios e através do monitoramento da comunidade de protozoários indicadores biológicos do lodo ativado, os testes de respirometria e os testes da análise biológica do lodo, respectivamente. Os resultados da atividade metabólica são apresentados em forma de gráficos, em termos de taxa de consumo de oxigênio específico e porcentagem de inibição. Os resultados da qualidade biológica são apresentados em números de 0 a 10 de acordo com o Índice de Madoni (1994). Os resultados demonstraram a imediata intoxicação dos lodos ativados em concentrações de sal a partir da concentração mínima utilizada neste trabalho, que foi de 5 gL de NaCl. Para entender melhor o processo de intoxicação foi realizado experimentos de 96 horas de monitoramento após o choque de cloreto de sódio nos reatores com lodos ativados, os resultados não demonstraram melhoria no processo. Os resultados sugerem que os testes de taxa de consumo de oxigênio em consonância com os testes da qualidade biológica são eficientes e complementares para a avaliação da influência da salinidade no processo de lodos ativados. / Effluent treatment process by sludge activated is one of the most used processes of treatment all over the world, mainly because of the quality of the final effluent. However, this process is a biological one, and so, it depends on the bacterial activity to the stabilization of the organic matter of the sewage. Considering this, it is necessary to maintain the ideal conditions to the survival and proliferation of the bacteria responsible for the process. This work considered two parameters to evaluate the influence of the salinity in the sludge activated processes; these parameters are widely used in research, however, little used for the monitoring of the Wastewater Treatment Plants. The objectives of this work are to investigate the influence of the salinity through the respirometry test and the biological quality of the sludge. The results of the metabolic activity are presented in graphics, in terms of Oxygen Uptake Rate and percentage of inhibition. The results of the biological quality are presented in numbers by 0 to 10 according to the Mandonis Index (1994). The results show the intoxication of the sludge activated in saline concentrations higher than 5 g/L of NaCl in the saline shock, and it seems that efficiency do not get better even after 96 hours. The results suggests that the respirometry test and the biological quality test are efficient and complementary to the evaluation of salinity in the sludge activated processes.
180

Tratamento de efluentes líquidos de unidades produtoras de farinha de mandioca

Roberto Albuquerque Lima 05 February 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A mandioca (Manihot esculenta) é a terceira cultura mais importante do país na alimentação básica da população. A produção de farinha de mandioca gera um efluente denominado manipueira que contem elevada quantidade de matéria orgânica e cianeto. O objetivo deste trabalho foi investigar a remoção da demanda química de oxigênio (DQO), turbidez e cianeto da manipueira por tratamentos físico-químico e biológico. No tratamento físico-químico por coagulação-floculação, três planejamentos fatoriais completos foram realizados para investigar os fatores: pH, tanino e o polímero sintético auxiliar da floculação (Polipan) sobre as variáveis respostas: DQO, turbidez e cianeto. A eficiência máxima de remoção de DQO foi 91 % a pH 8,0, na presença de tanino 1,0 mL/L e Polipan 0,030 ppm. A maior remoção de turbidez (75 %) foi determinada a pH 8 e tanino 0,8 mL/L, na ausência do Polipan para diminuir os custos do tratamento. Nessas condições, a redução máxima de cianeto foi de 12 %. Nos tratamentos biológicos aeróbios durante 48 h, as eficiências máximas de redução de DQO 88 % e de turbidez 69 % foram determinadas na presença de consórcio microbiano 20 % v/v, cloreto de amônio 5 - 6 % e a pH 8,0. Para os tratamentos físico-químico e biológico, os resultados obtidos mostram que o pH 8 foi fator chave para remoção de compostos orgânicos e do cianeto da manipueira. Os tratamentos da manipueira por coagulação-floculação e por consórcio microbiano diminuem a carga orgânica desse efluente antes de ser lançado nos recursos hídricos / Cassava (Manihot esculenta) is the third most important crop in the basic food of the Brazilian population. The production of cassava flour generates an effluent, called manipueira, containing high organic matter and cyanide. The objective of this study was to investigate the removal of chemical oxygen demand (COD), turbidity and cyanide from cassava wastewater by physical-chemical and biological treatments. In the physicalchemical treatment by coagulation-flocculation, three full factorial designs were carried out to investigate the factors: pH, tannin concentration and the flocculation polymer (Polipan) concentration on the response variables: COD, turbidity and cyanide. The maximum efficiency for COD removal was 91 % at pH 8.0 in the presence of tannin 1.0 mL/L and Polipan 0.030 ppm. The highest removal of turbidity (75 %) was determined at pH 8 and tannin 0.8 mL/L in the absence of Polipan to reduce the costs of treatment. Under these conditions, the maximum removal of cyanide was 12 %. In the aerobic biological treatment for 48 h, the maximum efficiencies for COD reduction of 88 % and for turbidity reduction of 69 % were determined in the presence of the microbial consortium 20 % v/v, ammonium chloride 5 6 % and at pH 8.0. For the treatments, physical-chemical and biological, the results show that pH 8 is a key factor for removal of organic compounds and cyanide from cassava wastewater. The treatments of the manipueira by coagulation-flocculation and by microbial consortium decrease the pollution of this effluent before being launched in the water resources

Page generated in 0.0791 seconds