• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • Tagged with
  • 16
  • 16
  • 14
  • 12
  • 7
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Impacto do lançamento de lodo de tanques/fossas sépticas em estação de tratamento de esgoto com reator anaeróbio de fluxo ascendente e manta de lodo (UASB) / Impact of sludge disposal of septic tanks on wastewater treatment plant with upflow anaerobic sludge blanket (UASB)

Gonçalves, Camila do Prado 31 October 2008 (has links)
Neste trabalho avaliou-se o desempenho de um reator anaeróbio de fluxo ascendente e manta de lodo (UASB) no tratamento combinado de esgoto sanitário com o lançamento de lodo proveniente de tanques sépticos. O estudo foi desenvolvido em escala plena na Estação de Tratamento de Esgoto (ETE) do Campus I da Universidade de São Paulo (USP) em São Carlos-SP. Foram utilizados dois reatores UASB com 18,8 m³ cada, um reator (UASB I) com função de controle e o outro reator (UASB II) no qual foi descarregado o lodo séptico. A pesquisa foi dividida em duas etapas: a primeira compreendeu o início de operação e o monitoramento dos reatores e, da segunda fez parte os ensaios de lançamento de lodo séptico no sistema. A partida foi efetuada sem utilização de inóculo e os reatores foram operados com tempo de detenção hidráulica médio (TDH) de 8 h, vazão afluente média de 2,35 m³/h e velocidade ascensional de 0,6 m/h. Em seis meses de operação os reatores apresentaram eficiências médias de remoção de DQO nos reatores UASB I e UASB II iguais a 49% e 65%. Quanto à remoção de sólidos os reatores UASB I e UASB II atingiram remoção de 36% e 37% para ST e de 67% e 63% para SST, respectivamente. Após esse período, deu-se início ao estudo que avaliou o impacto do lançamento de lodo séptico no UASB II. Foram realizados três ensaios com diferentes volumes de lodo (1; 3 e 5 m³) descarregados na forma de pulso com vazão média de 5,24 m³/h. Os lodos sépticos utilizados na pesquisa foram coletados por caminhões limpa-fossa e descarregados em um reservatório (15 m³) na ETE para posterior lançamento no reator UASB II. Foram feitas as caracterizações das amostras dos lodos sépticos (coletadas no ato da descarga em cada ensaio), com as quais pôde-se constatar a heterogeneidade da composição desse tipo de resíduo e sua viabilidade de pós-tratamento anaeróbio. Nos ensaios foram realizados monitoramentos temporais logo após a descarga de lodo para acompanhamento da resposta ao pulso de carga imposto. No geral, o reator UASB apresentou capacidade de degradar aproximadamente 2/3 da carga orgânica lançada com o lodo séptico. Os resultados são um indicativo de que a disposição de lodo sépticos em reatores UASB, quando bem programada, é uma solução viável e de grande importância para o tratamento dos resíduos provenientes de tanques/fossas sépticas. / The performance of upflow anaerobic sludge blanket (UASB) in the sanitary wastewater combined treatment with sludge disposal of septic tanks was evaluated in this work. The study was carried out (full scale) in the Wastewater Treatment Plant (WTP) located in campus I of the University of Sao Paulo (USP), city of Sao Carlos, State of Sao Paulo, Brazil. Two UASB reactors were used; volume of each reactor ~ 18,8 m³. UASB I was the control reactor, and UASB II was the reactor in which the septic sludge was disposed. The research was divided in two steps: the first one, which has taken into account the beginning of reactors operation and, the second one, in which occurred the disposal of septic sludge in the reactors. The start-up was carried out without utilization of inoculums. Reactors were operated with an average hydraulic retention time of 8 hours, average influent flow rate of 2.35 m³/h, and upflow velocity of 0.6 m/h. In six months, reactors presented average removal efficiencies of COD in UASB I and UASB II of 48% and 65%, respectively. Concerning to the solid removal, UASB I and UASB II have achieved removal of 36% and 37% for TS, and 67% and 63% for TSS, respectively. After this period of time, the evaluation of disposal impact of septic sludge was started in UASB II. Three essays with different sludge volume (1, 3, and 5 m³) were carried out; sludge volume was disposed in a pulse way with average flow rate of 5.24 m³/h. Septic sludge utilized in the research was collected by clean septic tank trucks, and disposed in a reservoir (volume of 15 m³) in WTP, in order to allow further disposal in the UASB II. By the hand of characterization of septic sludge samples (collected when disposal was carried out), it was possible to verify the heterogeneity about composition of this kind of waste and its availability in terms of anaerobic post-treatment. Temporal monitoring after the sludge disposal was carried out in order to allow the accompaniment of results provided by the pulse. In general, UASB reactor presented capacity in terms of degradation of approximately 2/3 of the organic load disposed with septic sludge. The results are a good indicative that the disposal of septic sludge in UASB reactors is a viable solution, and it is very important for the treatment of wastes from septic tanks.
12

Estudo de tratabilidade de lixiviado de aterro sanitário submetido à eletro-oxidação como pré-tratamento a um sistema de lodos ativados operado em batelada / Study treatability of landfill leachate subjected to electro-oxidation as a pretreatment to an activated sludge batch system

Natália de Souza Pelinson 08 November 2013 (has links)
O lixiviado de aterro sanitário é um efluente gerado a partir da mistura de líquidos produzidos na degradação de resíduos sólidos e a água pluvial que infiltra o depósito de material. Estudos na literatura, abordando tratamento de lixiviados de aterro sanitário, indicam que os processos biológicos podem não ser suficientes para que os padrões de lançamento vigentes na legislação sejam cumpridos. Neste contexto os processos oxidativos avançados estão sendo apontados como uma alternativa atrativa para efluentes que apresentam baixa biodegradabilidade. A presente pesquisa objetivou avaliar, em escala de bancada, a tratabilidade do lixiviado de aterro sanitário com aplicação do tratamento de oxidação eletroquímica seguida pelo tratamento biológico de um sistema de lodos ativados operado em batelada. A eletro-oxidação promove a remoção ou degradação de espécies poluentes, direta ou indiretamente, por meio de processos que não necessitam de adição de grandes quantidades de produtos químicos. Nos ensaios realizados com lixiviado bruto e com lixiviado alcalinizado submetido ao tratamento físico-químico de air stripping não houve necessidade de adicionar eletrólitos suporte para a oxidação química ocorrer e ao longo de tais ensaios a matéria foi mensurada quanto à DQO, COT e COD. Quando aplicada a eletro-oxidação no lixiviado bruto (sem tratamento prévio), houve 87% de remoção de DQO utilizando o anodo DDB com aplicação de 48 A h L-1 (densidade de corrente de 100 mA cm-2) e 65% de remoção da DQO quando utilizado o anodo DSA, nas mesmas condições. Analogamente, foram obtidos valores percentuais de remoção de COT de 70 e 60%, respectivamente e ainda 61 e 67% em relação ao COD. A fim de se complementar os estudos quanto à atuação da eletroquímica no tratamento do lixiviado de aterros sanitários, o efluente eletro-oxidado foi adicionado a um sistema de lodos ativados em duas proporções volumétricas distintas (2,5 e 5%) combinadas com esgoto sanitário (97,5 e 95%, respectivamente). Para controle e possível análise na eficiência, foram realizados ensaios com lixiviado bruto (5% de lixiviado bruto e 95% de esgoto sanitário) e somente esgoto sanitário (100%). Foram obtidos valores de remoção de DQO de: 75% em condição 100% esgoto sanitário, 64% com adição 2,5% de lixiviado eletro-oxidado, 57% com adição de 5% de lixiviado eletro-oxidado e 38% com adição de 5% de lixiviado bruto, além de valores percentuais de remoção de COT em cerca de 56, 52, 47 e 37%, respectivamente. E ainda foram obtida remoções nos valores de DBO na ordem de 91, 87, 64 e 24%, respectivamente. De forma geral, o sistema combinado proposto atingiu eficiências consideráveis e se mostrou compatível com o intuito de se estudar o aumento da tratabilidade por meio da aplicação de processos eletroquímicos em lixiviado bruto. / The landfill leachate is a wastewater generated from the mixture of liquids produced in the degradation of solid waste and rainwater that infiltrates the landfill. Studies in the literature approaching the treatment of landfill leachate indicate that biological processes may not be sufficient for the discharge standards prevailing in the present legislation. In this context the advanced oxidation processes (AOP) are being singled out as an attractive alternative for wastewater with a low biodegradability. This study aimed to evaluate, in a bench scale treatability of landfill leachate treatment with application of electrochemical oxidation followed by biological treatment of an activated sludge batch system. The electro-oxidation promotes the removal or degradation of pollutants species directly or indirectly, through processes which do not require addition of large amounts of chemicals. For tests with raw leachate and leachate with alkaline subjected to physico- chemical treatment of air stripping, there was no need to add support for electrolytes and chemical oxidation occurs over such trials the subject was measured as the COD, TOC and DOC. When applied the electro-oxidation in the raw leachate (without treatment) was reached 87% for COD removal using the DDB anode with the application of 48 L h-1 (current density 100 mA cm-2) and 65% COD removal when using the DSA anode under the same conditions. Similarly, the percentage values of TOC removal are 70 and 60 % respectively and also 61 and 67% compared to the DOC was obtained. In order to complement the studies regarding the performance of the electrochemical treatment of landfill leachate, the electro-oxidized effluent was added to an activated sludge system in two different volume ratios (2,5 and 5%) combined with sewage (97.5 and 95%, respectively). For control and possible efficiency analysis, testing with raw leachate (5% and 95 % crude leachate sanitary sewer) and only sanitary wastewater (100 %) were performed. Values of COD removal was obtained: 75% in 100% sewage condition, 64% with addition of 2,5% leachate electro- oxidized , with 57% addition of 5% leachate electro- oxidized and 38% with the addition of 5% raw leachate , and percentage values of TOC removal by about 56, 52, 47 and 37% , respectively. And BOD removal values were obtained in the order of 91, 87, 64 and 24%, respectively. In general, the proposed combined system has achieved considerable efficiency and proved to be compatible with the aim of studying the increased tractability through the use of electrochemical processes raw leachate.
13

Tratamento combinado de lixiviado de aterro sanitário e esgoto doméstico por processo anaeróbio em reator UASB

Miorim, Mirela 23 February 2018 (has links)
Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2018-04-03T16:15:47Z No. of bitstreams: 1 Mirela Miorim_.pdf: 846687 bytes, checksum: 14941a4020bedba06eadbccc896dd4d1 (MD5) / Made available in DSpace on 2018-04-03T16:15:47Z (GMT). No. of bitstreams: 1 Mirela Miorim_.pdf: 846687 bytes, checksum: 14941a4020bedba06eadbccc896dd4d1 (MD5) Previous issue date: 2018-02-23 / Nenhuma / O tratamento combinado de lixiviado de aterro sanitário (LAS) e esgoto sanitário (ES) é uma solução promissora, uma vez que com a diluição do lixiviado ocorre a redução de elevadas concentrações de nitrogênio amoniacal e matéria orgânica. No entanto, é necessário que sejam determinadas as proporções de LAS:ES adequadas para este tipo de tratamento. A presente pesquisa objetiva estudar o tratamento combinado por processo anaeróbio através de um reator anaeróbio de manta de lodo e fluxo ascendente (UASB), utilizando como substratos o esgoto sanitário e o lixiviado de aterro sanitário. A primeira etapa da pesquisa abordou os ensaios de bancada realizados, afim de caracterizar os substratos adotados e assim determinar o acréscimo de cargas orgânicas e de nutrientes, e alterações nos parâmetros físico-químicos (pH, alcalinidade e AGV) com a adição de 3 e 6% de lixiviado ao esgoto sanitário. A segunda etapa da pesquisa compreende ensaios em escala piloto, utilizando o reator UASB em regime contínuo, com 830L, operando com um TDH de 12 h,e temperatura ambiente a qual foi monitorada por um termômetro no corpo do reator. O reator UASB foi inoculado com lodo anaeróbio proveniente do reator UASB em escala plena da UNISINOS. Este lodo apresentou uma concentração de 515 mg ST/L, 265,4 mg SV/L e 250,2 mg SF/L. O reator UASB operou inicialmente apenas com esgoto sanitário por um período de 127 dias (Fase 1), em seguida operou por 49 dias com a adição de 3% de LAS (Fase 2) e a última fase por um período de 28 dias com a adição de 6% de LAS (Fase 3). Verificou-se que houve um equilíbrio no pH, alcalinidade e AGV na Fase 1, enquanto que nas Fases 2 e 3 estes parâmetros sofreram uma elevação no afluente, e um decréscimo na alcalinidade efluente devido a necessidade de se neutralizar os AGV. Foi verificada uma concentração média de alcalinidade afluente e efluente de 114,7 e 129,3 mgCaCO3/L (Fase 1), de 373,0 e 345,0 mgCaCO3/L (Fase 2) e 665,8 e 581,3 mgCaCO3/L (Fase 3), nesta ordem. O pH inicial do afluente operando somente com ES foi de 6,9, chegando a 8,8 na Fase 3 na mistura com 6% de LAS. Foi observado que o nitrogênio amoniacal afetou diretamente o processo anaeróbio, uma vez que o aumento da alcalinidade do afluente ao partir da entrada do LAS ao processo, este aumento foi atribuído a formação de hidróxido de amônia a partir do nitrogênio amoniacal presente no LAS. A concentração de nitrogênio amoniacal correspondeu a mais de 80% do nitrogênio total da mistura LAS:ES, e manteve-se nestes patamares durante todo o período experimental. As concentrações de nitrogênio amoniacal afluente e efluente, foram, respectivamente, 31,4 e 42,7 mg/L (Fase 1), 60,8 e 60,8 mg/L (Fase 2) e 91,9 e 89,4 mg/L (Fase 3). A remoção de DQO na Fase 1 variou entre 27,1 - 63,6%, de 33,7 - 54,7% na Fase 2 e de 22,9 - 32,3% na Fase 3. Para as condições estudas não verificou-se uma elevada eficiência de remoção de matéria orgânica no reator operando com a mistura LAS:ES. Quantitativamente observou-se teores de metano entre 63,2 e 74%. / The combined treatment of landfill leachate (LAS) and sanitary sewage (ES) is a promising solution, since with the dilution of the leachate the reduction of high concentrations of ammoniacal nitrogen and organic matter occurs. However, it is necessary to determine the proportions of LAS: ES suitable for this type of treatment. The present research aims to study the combined treatment by anaerobic process through an anaerobic sludge blanket and UASB reactor, using wastewater and landfill leachate as substrates. The first stage of the research was carried out in order to characterize the substrates and to determine the increase of organic loads and nutrients, as well as changes in physical and chemical parameters (pH, alkalinity and VFA) with the addition of 3 and 6% of leachate to wastewater. The second stage of the research involves pilot scale tests using the continuous UASB reactor with 830 L, operating with a HRT of 12 h, and ambient temperature which was monitored by a thermometer in the reactor. UASB reactor was inoculated with anaerobic sludge from the UASB reactor at full scale from UNISINOS, this sludge presented a concentration of 515 mg ST/L, 265.4 mg VS/L and 250.2 mg FS/L. UASB reactor initially operated only with wastewater for a period of 127 days (Phase 1), then operated for 49 days with the addition of 3% leachate (Phase 2) and the last phase for a period of 28 days with addition of 6% leachate (Stage 3). It was verified that there was a balance in pH, alkalinity and VFA in Phase 1, whereas in Phases 2 and 3 these parameters suffered an increase in the affluent, and a decrease in the alkalinity effluent due to the necessity to neutralize the VFA. A mean affluent alkalinity affluent and effluent concentration of 114.7 and 129.3 mgCaCO3/L (Phase 1), 373.0 and 345.0 mgCaCO3/L (Phase 2) and 665.8 and 581.3 mgCaCO3/L (Phase 3), in that order. The initial pH effluent operating with wastewater alone was 6.9, reaching 8.8 in Phase 3 in the mixture with 6% of leachate. It was observed that the ammonia nitrogen directly affected the anaerobic process, since the increase of the alkalinity of the affluent from the addition of the leachate to the process, this increase was attributed to the formation of ammonia hydroxide from the ammonia nitrogen present in the leachate. The concentration of ammonia nitrogen corresponded to more than 80% of the total nitrogen of the leachate/wastewater mixture, and remained at these levels throughout the experimental period. The concentrations of ammonia nitrogen affluent and effluent were respectively 31.4 and 42.7 mg/L (Phase 1), 60.8 and 60.8 mg/L (Phase 2) and 91.9 and 89.4 mg/L (Phase 3). Removal of COD in Phase 1 ranged from 27.1 - 63.6%, from 33.7 - 54.7% in Phase 2 and from 22.9 - 32.3% in Phase 3. In the conditions under study, a high removal efficiency of organic matter was not verified in the reactor operating with the leachate/wastewater mixture. Methane levels between 63.2 and 74% were quantitatively observed.
14

Toxicidade no cotratamento de esgoto sanitário e lixiviado de aterro sanitário / Toxicity in co-treatment of sanitary sewage and landfill leachate

Magalhães, Déborah Neide de 15 February 2012 (has links)
Made available in DSpace on 2015-03-26T13:28:08Z (GMT). No. of bitstreams: 1 texto completo.pdf: 240547 bytes, checksum: 20321868b10a192937153ede468b05e2 (MD5) Previous issue date: 2012-02-15 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Sanitary landfill leachate has high, potentially toxic organic and nutrient loads that may cause negative impacts during combined biological treatment with sewage. In this study, the effect of intermittent leachate addition at the inlet of the activated sludge municipal sewage treatment plant in Juiz de Fora, Minas Gerais, located in southeastern Brazil, was evaluated. Raw sewage, leachate, mixed leachate-sewage and treated wastewater samples were collected monthly over six months for physicochemical characterization (organic matter, solids, nutrients, metals) and determination of acute toxicity to Daphnia similis. Return activated sludge was also collected and used to quantify specific oxygen uptake rate (SOUR) and biomass growth in sewage and leachate-sewage mixtures in the laboratory. Leachate presented higher values than sewage for all parameters measured, except phosphorous, though its composition varied widely. Activated sludge treatment efficiently removed organic matter and nutrients, despite the high intermittent loads associated with leachate added at the treatment plant inlet. The only parameters that regularly surpassed Minas Gerais state discharge limits were Hg and Pb. Contrary to the raw sewage that did not exhibit toxicity, all samples of leachate were acutely toxic to D. similis and this led to toxicity in four of the mixed leachate-sewage samples, while only one sample of treated wastewater exhibited slight toxicity. Leachate toxicity correlated positively with pH, nitrogen and conductivity. Potentiation of the toxic effect was observed in leachate-sewage mixtures prepared in the laboratory. SOUR values and sludge production increased in mixtures of 20% leachate-80% sewage over their values in sewage alone. SOUR values correlated negatively with As, Cd, Hg and Pb. The results suggest that activated sludge can adapt to the increased organic and nutrient load associated with landfill leachate over time, but the effect of the impulse loads that enter with leachate should be investigated further. / O lixiviado de aterro sanitário apresenta elevadas cargas orgânicas e de nutrientes potencialmente tóxicas, que podem causar impactos negativos durante o tratamento biológico combinado com esgoto. Nesta pesquisa foi avaliado o efeito da adição de lixiviado ao esgoto sanitário no cotratamento por lodos ativados em uma ETE no município de Juiz de Fora, sudeste do Brasil. Esgoto bruto, lixiviado, mistura esgoto-lixiviado afluente na ETE e efluente secundário foram coletados mensalmente, durante 6 meses, caracterizados físico-quimicamente (matéria orgânica, sólidos, nutrientes e metais) e avaliadas quanto à toxicidade aguda à Daphnia similis. Lodo da linha de reciclo foi coletado para a quantificação da taxa específica de consumo de oxigênio (SOUR) e de crescimento de biomassa do lodo no esgoto bruto e em misturas esgoto-lixiviado preparadas em bancada. Os resultados evidenciaram a grande variabilidade na composição do lixiviado, o qual apresentou valores mais elevados em todas as variáveis analisadas, exceto o fósforo. Apesar da elevada carga orgânica adicionada de forma intermitente no sistema, o tratamento por lodos ativados parece remover de forma eficiente a matéria orgânica e nutrientes e produz um efluente secundário com baixas concentrações de DQO e N orgânico. O efluente secundário apresentou concentrações de Hg e Pb acima dos limites estabelecidos para lançamento em corpos d água no estado de Minas Gerais. Ao contrário do esgoto bruto, todas as amostras de lixiviado foram tóxicas à D. similis, o que conferiu toxicidade à mistura afluente na ETE em algumas amostragens. Somente uma amostra de efluente secundário apresentou ligeira toxicidade. A toxicidade do lixiviado correlacionou-se positivamente com o pH, nitrogênio e condutividade. Testes de toxicidade em misturas preparadas em bancada evidenciaram o efeito de potencialização da toxicidade do lixiviado. Há uma tendência do aumento da SOUR com o aumento da proporção de lixiviado na mistura e os valores de SOUR correlacionaram-se negativamente com As, Cd, Hg e Pb. Os resultados sugerem que os lodos ativados podem se adaptar a misturas com maiores concentrações de lixiviado ao longo do tempo, mas o efeito de altas cargas na entrada do sistema deve ser investigado futuramente.
15

Filtro anaeróbio ascendente combinado com reator aeróbio de lodos ativados em batelada no tratamento de água residuária sintética de indústria de polpa celulósica não branqueada sob condições termofílicas / Upflow anaerobic filter combined with aerobic reactor of activated sludge in batch treating of synthetic wastewater from unbleached cellulose pulp plant under thermophilic conditions

Cláudia Regina Megda 20 September 2007 (has links)
Um sistema combinado anaeróbio-aeróbio composto de um filtro anaeróbio ascendente seguido de reator aeróbio de lodos ativados em batelada, foi continuamente alimentado com água residuária sintética da indústria de polpa celulósica não branqueada, durante o período de trezentos e sessenta e três dias, com o objetivo de verificar o desempenho dos reatores operados sob condições termofílicas. Os reatores foram inoculados com lodo mesofílico com gradual adaptação para a condição termofílica e operados em duas fases distintas. A primeira e segunda fases contemplam os períodos em que os reatores foram operados em temperatura termofílica de 55 e 65 graus Celsius, respectivamente. O filtro anaeróbio trabalhou com tempo de detenção hidráulica de 48 horas em fluxo contínuo e o reator aeróbio operado em bateladas seqüenciais (RBS) com tempos de ciclo de 12, 18 e 24 horas. A melhor eficiênica de remoção de DQO do sistema combinado anaeróbio-aeróbio foi de 65%, devida, em maior parte ao reator anaeróbio. O filtro anaeróbio operado em temperatura de 55 e 65 graus demonstrou eficiência na capacidade de retenção de biomassa termofílica, evitando a perda no efluente. O RBS, quando operado em temperatura de 55 graus e tempo de ciclo de 18 horas, demonstrou melhor eficiência para pós-tratamento de água residuária sintética. Os resultados gerais mostram uma melhor eficiência dos reatores operados em temperatura de 55 graus Celsius. / A combined anaerobic-aerobic system, composed of an upflow anaerobic filter followed by an aerobic reactor of activated sludge in batch, was continuously feed with synthetic wastewater from unbleached cellulose pulp plant during a period of three hundred and sixty three days, aiming to verify the performance of the reactors operating under thermophilic conditions. The reactors were inoculated with mesophilic sludge having a gradual adaptation to the thermophilic condition and they were operated in two distinct phases. The first and second phases contemplate the periods in which the reactors were operated in a thermophilic temperature of 55 and 65 Celsius degrees, respectively. The anaerobic filter worked with hydraulic detention time of 48 hours in a continuous flow, and the aerobic reactor was operated in a sequencing batch (SBR) with a cycle time of 12, 18 and 24 hours. The best efficiency of the combined anaerobic-aerobic system to remove DQO was 65% due to, in most part, the anaerobic reactor. The anaerobic filter, operating in temperatures of 55 and 65 degrees, has demonstrated efficiency in the capacity to retain thermophilic biomass, avoiding effluent lost. The SBR reactor, when operated in temperature of 55 degrees and a cycle time of 18 hours, has demonstrated better efficiency in the post-treatment of synthetic wastewater. The general results have showed a better efficiency of the reactors operating in a thermophilic temperature of 55 Celsius degrees.
16

Impacto do lançamento de lodo de tanques/fossas sépticas em estação de tratamento de esgoto com reator anaeróbio de fluxo ascendente e manta de lodo (UASB) / Impact of sludge disposal of septic tanks on wastewater treatment plant with upflow anaerobic sludge blanket (UASB)

Camila do Prado Gonçalves 31 October 2008 (has links)
Neste trabalho avaliou-se o desempenho de um reator anaeróbio de fluxo ascendente e manta de lodo (UASB) no tratamento combinado de esgoto sanitário com o lançamento de lodo proveniente de tanques sépticos. O estudo foi desenvolvido em escala plena na Estação de Tratamento de Esgoto (ETE) do Campus I da Universidade de São Paulo (USP) em São Carlos-SP. Foram utilizados dois reatores UASB com 18,8 m³ cada, um reator (UASB I) com função de controle e o outro reator (UASB II) no qual foi descarregado o lodo séptico. A pesquisa foi dividida em duas etapas: a primeira compreendeu o início de operação e o monitoramento dos reatores e, da segunda fez parte os ensaios de lançamento de lodo séptico no sistema. A partida foi efetuada sem utilização de inóculo e os reatores foram operados com tempo de detenção hidráulica médio (TDH) de 8 h, vazão afluente média de 2,35 m³/h e velocidade ascensional de 0,6 m/h. Em seis meses de operação os reatores apresentaram eficiências médias de remoção de DQO nos reatores UASB I e UASB II iguais a 49% e 65%. Quanto à remoção de sólidos os reatores UASB I e UASB II atingiram remoção de 36% e 37% para ST e de 67% e 63% para SST, respectivamente. Após esse período, deu-se início ao estudo que avaliou o impacto do lançamento de lodo séptico no UASB II. Foram realizados três ensaios com diferentes volumes de lodo (1; 3 e 5 m³) descarregados na forma de pulso com vazão média de 5,24 m³/h. Os lodos sépticos utilizados na pesquisa foram coletados por caminhões limpa-fossa e descarregados em um reservatório (15 m³) na ETE para posterior lançamento no reator UASB II. Foram feitas as caracterizações das amostras dos lodos sépticos (coletadas no ato da descarga em cada ensaio), com as quais pôde-se constatar a heterogeneidade da composição desse tipo de resíduo e sua viabilidade de pós-tratamento anaeróbio. Nos ensaios foram realizados monitoramentos temporais logo após a descarga de lodo para acompanhamento da resposta ao pulso de carga imposto. No geral, o reator UASB apresentou capacidade de degradar aproximadamente 2/3 da carga orgânica lançada com o lodo séptico. Os resultados são um indicativo de que a disposição de lodo sépticos em reatores UASB, quando bem programada, é uma solução viável e de grande importância para o tratamento dos resíduos provenientes de tanques/fossas sépticas. / The performance of upflow anaerobic sludge blanket (UASB) in the sanitary wastewater combined treatment with sludge disposal of septic tanks was evaluated in this work. The study was carried out (full scale) in the Wastewater Treatment Plant (WTP) located in campus I of the University of Sao Paulo (USP), city of Sao Carlos, State of Sao Paulo, Brazil. Two UASB reactors were used; volume of each reactor ~ 18,8 m³. UASB I was the control reactor, and UASB II was the reactor in which the septic sludge was disposed. The research was divided in two steps: the first one, which has taken into account the beginning of reactors operation and, the second one, in which occurred the disposal of septic sludge in the reactors. The start-up was carried out without utilization of inoculums. Reactors were operated with an average hydraulic retention time of 8 hours, average influent flow rate of 2.35 m³/h, and upflow velocity of 0.6 m/h. In six months, reactors presented average removal efficiencies of COD in UASB I and UASB II of 48% and 65%, respectively. Concerning to the solid removal, UASB I and UASB II have achieved removal of 36% and 37% for TS, and 67% and 63% for TSS, respectively. After this period of time, the evaluation of disposal impact of septic sludge was started in UASB II. Three essays with different sludge volume (1, 3, and 5 m³) were carried out; sludge volume was disposed in a pulse way with average flow rate of 5.24 m³/h. Septic sludge utilized in the research was collected by clean septic tank trucks, and disposed in a reservoir (volume of 15 m³) in WTP, in order to allow further disposal in the UASB II. By the hand of characterization of septic sludge samples (collected when disposal was carried out), it was possible to verify the heterogeneity about composition of this kind of waste and its availability in terms of anaerobic post-treatment. Temporal monitoring after the sludge disposal was carried out in order to allow the accompaniment of results provided by the pulse. In general, UASB reactor presented capacity in terms of degradation of approximately 2/3 of the organic load disposed with septic sludge. The results are a good indicative that the disposal of septic sludge in UASB reactors is a viable solution, and it is very important for the treatment of wastes from septic tanks.

Page generated in 0.1055 seconds