Mineralização de timol e bisfenol-A via ozônio, radiação ultravioleta e peróxido de hidrogênio / Mineralization of thymol and bisphenol-A by ozone, ultraviolet radiation and hydrogen peroxide

Xavier, Tatiana Mitsusaki Ricci 02 September 2011 (has links)
Com o intuito de viabilizar, ambiental e economicamente, a mineralização de substâncias fenólicas presentes em águas e efluentes, foram estudadas as moléculas do timol (C10H14O TOH, a 200 mg L-1) e do bisfenol-A (C15H16O2 BPA, a 25 mg L-1) utilizando Processos Oxidativos Avançados (POA), no caso, ozônio (O3), radiação ultravioleta (UV) e peróxido de hidrogênio (H2O2) que, quando combinados, ou em condições específicas, promovem a geração de radicais hidroxila (OH), um poderoso oxidante. O sistema de tratamento utilizado foi desenvolvido no próprio Laboratório de Tratamento de Resíduos do CENA/USP. O TOH e o BPA foram submetidos a tratamento em pH 3 e 11, com O3 (1,98 g h-1) e UV (0, 8 e 32 watts). Adicionalmente, o TOH foi tratado também com H2O2 (0, 1.176 e 2.352 mg), totalizando 18 tratamentos para o TOH e 6 para o BPA. A eficiência dos tratamentos foi avaliada a partir da porcentagem de remoção do carbono orgânico total (TOC). Para ambas as moléculas, a combinação 1,98 g h-1 de O3, 32 watts UV e ausência de H2O2, em pH 3, apresentou os melhores resultados de conversão de TOC a CO2, especificamente 99,6 ± 0,6% em 90 minutos para o timol e 93,9 ± 0,6% de mineralização de bisfenol-A em 60 minutos de tratamento. Este tratamento foi então reproduzido no resíduo de timol gerado pelos laboratórios do CENA/USP e o resultado obtido foi de 92,64 ± 1,2%, um pouco inferior ao obtido para a solução de TOH, provavelmente devido à presença de outras substâncias. As soluções (TOH e BPA) e o resíduo (TOH) tratados foram submetidos à análise de fenóis totais, obtendo-se resultados inferiores ao exigido (0,5 mg L-1 de fenóis totais) pelas resoluções CONAMA 357/2005 e 397/2008 para a disposição em corpos hídricos. Realizaram-se também ensaios de toxicidade com os organismos Pseudokirchneriella subcapitata, Daphnia magna e Hydra attenuata (que representam os distintos níveis tróficos da cadeia alimentar), que evidenciaram redução da toxicidade das soluções de TOH e BPA após tratamento, sendo que o mesmo não ocorreu para o resíduo de timol, provavelmente devido à sua constituição. Os resultados indicam que o tempo de tratamento seria uma variável importante a ser estudada no tratamento dos resíduos de TOH gerados nos laboratórios do CENA/USP. Os POA (O3/UV e O3/UV/H2O2) propostos no presente trabalho mostraram-se uma alternativa adequada, eficiente e com custos competitivos em relação a outras tecnologias no tratamento destes compostos fenólicos / In order to facilitate, environmentally and economically the mineralization of phenolic substances present in water and wastewater, a study was carried out with the molecules of thymol (C10H14O TOH, in a concentration of 200 mg L-1) and bisphenol-A (C15H16O2 BPA, in a concentration of 25 mg L-1) using Advanced Oxidation Processes (AOP). The AOP used were ozone (O3), ultraviolet radiation (UV) and hydrogen peroxide (H2O2) which, when combined or in specific conditions, promote a hydroxyl radicals (OH) formation, a powerful oxidant. The line system used was developed in the Residues Treatment Laboratory at CENA/USP. The TOH and BPA were submitted to the treatment at pH 3 and 11, with O3 (1.98 g h-1) and UV (0.8 and 32 watts). Additionally, the TOH was also treated with H2O2 (0, 1,176 and 2,352 mg), totalizing 18 treatments for TOH and 6 for BPA. The treatments efficiency was assessed by the percentage of total organic carbon (TOC) removed. For both molecules, the combination of 1.98 g h-1 of O3, 32 watts of UV and absence of H2O2, at pH 3, showed the best conversion of TOC to CO2, specifically 99.6 ± 0.6% of TOH in 90 minutes and 93.9 ± 0.6% of BPA in 60 minutes of treatment. This treatment was reproduced in the TOH residue generated by the CENA/USP laboratories. The TOC removal was 92.6 ± 1.2%, slightly lower than that obtained for the solution of TOH, probably due to the presence of other substances. The solutions (BPA and TOH) and the residue (TOH) treated were submitted to the total phenols analysis, resulting in values lower than demanded (0.5 mg L-1 of total phenols) by the law in force (CONAMA 357/2005 and 397/2008), which regulates the discharge of wastewater in the environment. We carried out also toxicological tests with the organisms Pseudokirchneriella subcapitata, Daphnia magna and Hydra attenuate (representing species in different levels of the food chain). The toxicity of solutions (TOH and BPA) decreased after treatment, but the same results were not observed in the TOH residue, probably due to its composition. The results show that treatment time is an important variable that should be studied for treatment of TOH residue generated in the CENA/USP laboratories. The AOP (O3/UV and O3/UV/H2O2) proposed showed up as a suitable alternative in terms of efficiency and cost-competitive when compared with other technologies to treatment of these phenolic compounds
2

Mineralização de timol e bisfenol-A via ozônio, radiação ultravioleta e peróxido de hidrogênio / Mineralization of thymol and bisphenol-A by ozone, ultraviolet radiation and hydrogen peroxide

Tatiana Mitsusaki Ricci Xavier 02 September 2011 (has links)
Com o intuito de viabilizar, ambiental e economicamente, a mineralização de substâncias fenólicas presentes em águas e efluentes, foram estudadas as moléculas do timol (C10H14O TOH, a 200 mg L-1) e do bisfenol-A (C15H16O2 BPA, a 25 mg L-1) utilizando Processos Oxidativos Avançados (POA), no caso, ozônio (O3), radiação ultravioleta (UV) e peróxido de hidrogênio (H2O2) que, quando combinados, ou em condições específicas, promovem a geração de radicais hidroxila (OH), um poderoso oxidante. O sistema de tratamento utilizado foi desenvolvido no próprio Laboratório de Tratamento de Resíduos do CENA/USP. O TOH e o BPA foram submetidos a tratamento em pH 3 e 11, com O3 (1,98 g h-1) e UV (0, 8 e 32 watts). Adicionalmente, o TOH foi tratado também com H2O2 (0, 1.176 e 2.352 mg), totalizando 18 tratamentos para o TOH e 6 para o BPA. A eficiência dos tratamentos foi avaliada a partir da porcentagem de remoção do carbono orgânico total (TOC). Para ambas as moléculas, a combinação 1,98 g h-1 de O3, 32 watts UV e ausência de H2O2, em pH 3, apresentou os melhores resultados de conversão de TOC a CO2, especificamente 99,6 ± 0,6% em 90 minutos para o timol e 93,9 ± 0,6% de mineralização de bisfenol-A em 60 minutos de tratamento. Este tratamento foi então reproduzido no resíduo de timol gerado pelos laboratórios do CENA/USP e o resultado obtido foi de 92,64 ± 1,2%, um pouco inferior ao obtido para a solução de TOH, provavelmente devido à presença de outras substâncias. As soluções (TOH e BPA) e o resíduo (TOH) tratados foram submetidos à análise de fenóis totais, obtendo-se resultados inferiores ao exigido (0,5 mg L-1 de fenóis totais) pelas resoluções CONAMA 357/2005 e 397/2008 para a disposição em corpos hídricos. Realizaram-se também ensaios de toxicidade com os organismos Pseudokirchneriella subcapitata, Daphnia magna e Hydra attenuata (que representam os distintos níveis tróficos da cadeia alimentar), que evidenciaram redução da toxicidade das soluções de TOH e BPA após tratamento, sendo que o mesmo não ocorreu para o resíduo de timol, provavelmente devido à sua constituição. Os resultados indicam que o tempo de tratamento seria uma variável importante a ser estudada no tratamento dos resíduos de TOH gerados nos laboratórios do CENA/USP. Os POA (O3/UV e O3/UV/H2O2) propostos no presente trabalho mostraram-se uma alternativa adequada, eficiente e com custos competitivos em relação a outras tecnologias no tratamento destes compostos fenólicos / In order to facilitate, environmentally and economically the mineralization of phenolic substances present in water and wastewater, a study was carried out with the molecules of thymol (C10H14O TOH, in a concentration of 200 mg L-1) and bisphenol-A (C15H16O2 BPA, in a concentration of 25 mg L-1) using Advanced Oxidation Processes (AOP). The AOP used were ozone (O3), ultraviolet radiation (UV) and hydrogen peroxide (H2O2) which, when combined or in specific conditions, promote a hydroxyl radicals (OH) formation, a powerful oxidant. The line system used was developed in the Residues Treatment Laboratory at CENA/USP. The TOH and BPA were submitted to the treatment at pH 3 and 11, with O3 (1.98 g h-1) and UV (0.8 and 32 watts). Additionally, the TOH was also treated with H2O2 (0, 1,176 and 2,352 mg), totalizing 18 treatments for TOH and 6 for BPA. The treatments efficiency was assessed by the percentage of total organic carbon (TOC) removed. For both molecules, the combination of 1.98 g h-1 of O3, 32 watts of UV and absence of H2O2, at pH 3, showed the best conversion of TOC to CO2, specifically 99.6 ± 0.6% of TOH in 90 minutes and 93.9 ± 0.6% of BPA in 60 minutes of treatment. This treatment was reproduced in the TOH residue generated by the CENA/USP laboratories. The TOC removal was 92.6 ± 1.2%, slightly lower than that obtained for the solution of TOH, probably due to the presence of other substances. The solutions (BPA and TOH) and the residue (TOH) treated were submitted to the total phenols analysis, resulting in values lower than demanded (0.5 mg L-1 of total phenols) by the law in force (CONAMA 357/2005 and 397/2008), which regulates the discharge of wastewater in the environment. We carried out also toxicological tests with the organisms Pseudokirchneriella subcapitata, Daphnia magna and Hydra attenuate (representing species in different levels of the food chain). The toxicity of solutions (TOH and BPA) decreased after treatment, but the same results were not observed in the TOH residue, probably due to its composition. The results show that treatment time is an important variable that should be studied for treatment of TOH residue generated in the CENA/USP laboratories. The AOP (O3/UV and O3/UV/H2O2) proposed showed up as a suitable alternative in terms of efficiency and cost-competitive when compared with other technologies to treatment of these phenolic compounds
3

Estudo da viabilidade do tratamento eletromagnético para água de resfriamento em indústrias químicas. / Study of the feasibility of electromagnetic treatment for cooling water in chemical industries.

Schaly, Rita Joseane Oliveira Câmara 18 September 2015 (has links)
O segmento industrial é um grande usuário de água e, na maior parte das situações, está localizado junto a aglomerações urbanas, caracterizando situação de dificuldade na obtenção deste recurso para as suas operações. As fontes de água estão cada vez mais saturadas e os processos de tratamento mais sofisticados. O objetivo deste estudo foi avaliar a viabilidade técnico-econômica da implantação do tratamento eletromagnético para água de resfriamento em indústrias químicas, substituindo ou complementando o tratamento químico convencional. O texto descreve inicialmente os fundamentos do tratamento de água baseado na aplicação de campo eletromagnético e, em seguida, os efeitos do uso dessa tecnologia sobre custos anuais de resfriamento em um caso típico da indústria química. Neste estudo foi dada ênfase ao efeito sobre os custos anuais da menor adição de produtos químicos, redução na vazão de purga e de reposição de água, além da redução na frequência de limpeza dos equipamentos e redução da carga poluente nos efluentes líquidos. O estudo foi aplicado a uma torre de resfriamento industrial, para a qual foi elaborado um modelo matemático considerando as taxas de consumo e especificações de água de resfriamento, além de parâmetros do processo de tratamento de água convencional e eletromagnético. São apresentados resultados de um estudo de sensibilidade para diferentes cenários, em que são identificados os fatores com maior efeito sobre os custos. Além disso, na aplicação ao sistema proposto, são estimadas condições ótimas de operação, considerando os ciclos de concentração para os quais pode haver maior redução de custos. Utilizando-se o tratamento eletromagnético para a água de resfriamento, há uma economia significativa, pois o número de paradas para a manutenção dos equipamentos pode ser reduzido. Dessa forma, o produto final do trabalho constitui-se em uma estrutura de cálculo voltada à estimação de custo do tratamento físico de água de resfriamento, o qual pode ser aplicado a diferentes cenários e condições de operação industrial. / The industrial sector is a major water user and in most situations is located next to urban areas, in a situation of increasing difficulty in collecting and treating water resources for its operations. The water sources are becoming more saturated and thus demanding more sophisticated treatment processes. The aim of this study was to evaluate the technical and economic feasibility of the implementation of electromagnetic treatment of cooling water in chemical industries, thus replacing or complementing the conventional chemical treatment. The text initially describes the principles of the physical process for water treatment based on the application of an electromagnetic field, and then focuses on the effects of the use of this technology on the annual costs of cooling in a typical case of the chemical industry. The study is focused on the effects of the electromagnetic treatment on the annual cost of cooling in view of the reduced consumption of chemicals, as well as reduction in purge flow and water replacement, reduced frequency of equipment cleaning, and reduction of pollution load caused by wastewater. The study results were applied to an industrial cooling tower for which a mathematical model was developed by considering consumption rates and cooling water specifications, as well as parameters of the electromagnetic and conventional water treatment processes. A sensitivity study was carried out for different scenarios, in which the most important factors affecting the annual cost are identified, and optimal process conditions are estimated for maximum concentration cycles. The study shows that the use of electromagnetic treatment for cooling water results in significant savings due to the reduced number of maintenance periods. The final product of this study is a calculation structure for cost estimation related to the physical treatment of cooling water, which can be applied to different scenarios and industrial operation conditions.
4

Estudo da viabilidade do tratamento eletromagnético para água de resfriamento em indústrias químicas. / Study of the feasibility of electromagnetic treatment for cooling water in chemical industries.

Rita Joseane Oliveira Câmara Schaly 18 September 2015 (has links)
O segmento industrial é um grande usuário de água e, na maior parte das situações, está localizado junto a aglomerações urbanas, caracterizando situação de dificuldade na obtenção deste recurso para as suas operações. As fontes de água estão cada vez mais saturadas e os processos de tratamento mais sofisticados. O objetivo deste estudo foi avaliar a viabilidade técnico-econômica da implantação do tratamento eletromagnético para água de resfriamento em indústrias químicas, substituindo ou complementando o tratamento químico convencional. O texto descreve inicialmente os fundamentos do tratamento de água baseado na aplicação de campo eletromagnético e, em seguida, os efeitos do uso dessa tecnologia sobre custos anuais de resfriamento em um caso típico da indústria química. Neste estudo foi dada ênfase ao efeito sobre os custos anuais da menor adição de produtos químicos, redução na vazão de purga e de reposição de água, além da redução na frequência de limpeza dos equipamentos e redução da carga poluente nos efluentes líquidos. O estudo foi aplicado a uma torre de resfriamento industrial, para a qual foi elaborado um modelo matemático considerando as taxas de consumo e especificações de água de resfriamento, além de parâmetros do processo de tratamento de água convencional e eletromagnético. São apresentados resultados de um estudo de sensibilidade para diferentes cenários, em que são identificados os fatores com maior efeito sobre os custos. Além disso, na aplicação ao sistema proposto, são estimadas condições ótimas de operação, considerando os ciclos de concentração para os quais pode haver maior redução de custos. Utilizando-se o tratamento eletromagnético para a água de resfriamento, há uma economia significativa, pois o número de paradas para a manutenção dos equipamentos pode ser reduzido. Dessa forma, o produto final do trabalho constitui-se em uma estrutura de cálculo voltada à estimação de custo do tratamento físico de água de resfriamento, o qual pode ser aplicado a diferentes cenários e condições de operação industrial. / The industrial sector is a major water user and in most situations is located next to urban areas, in a situation of increasing difficulty in collecting and treating water resources for its operations. The water sources are becoming more saturated and thus demanding more sophisticated treatment processes. The aim of this study was to evaluate the technical and economic feasibility of the implementation of electromagnetic treatment of cooling water in chemical industries, thus replacing or complementing the conventional chemical treatment. The text initially describes the principles of the physical process for water treatment based on the application of an electromagnetic field, and then focuses on the effects of the use of this technology on the annual costs of cooling in a typical case of the chemical industry. The study is focused on the effects of the electromagnetic treatment on the annual cost of cooling in view of the reduced consumption of chemicals, as well as reduction in purge flow and water replacement, reduced frequency of equipment cleaning, and reduction of pollution load caused by wastewater. The study results were applied to an industrial cooling tower for which a mathematical model was developed by considering consumption rates and cooling water specifications, as well as parameters of the electromagnetic and conventional water treatment processes. A sensitivity study was carried out for different scenarios, in which the most important factors affecting the annual cost are identified, and optimal process conditions are estimated for maximum concentration cycles. The study shows that the use of electromagnetic treatment for cooling water results in significant savings due to the reduced number of maintenance periods. The final product of this study is a calculation structure for cost estimation related to the physical treatment of cooling water, which can be applied to different scenarios and industrial operation conditions.

Page generated in 0.1035 seconds