• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Prédiction des lésions pulmonaires lors d’un impact balistique non pénétrant / Prediction of lung injuries during ballistic blunt thoracic trauma

Prat, Nicolas 30 November 2011 (has links)
Les impacts non transfixiants sur les gilets pare-balles sont responsables de lésions non pénétrantes potentiellement létales, regroupées sous le terme d’effets arrière (Behind Armor Blunt Trauma : BABT). De telles lésions fermées se retrouvent également lors d’impacts thoraciques de projectiles d’Armes à Létalité Réduite cinétiques (ALRc). Afin d’améliorer le pouvoir protecteur des protections balistiques et de mieux maitriser le pouvoir vulnérant des ALRc, il est nécessaire de définir un critère lésionnel permettant de prédire l’importance des lésions en cas de traumatisme thoracique fermé de type balistique. Ce critère se doit d’être bien corrélé à la gravité du traumatisme, et de pouvoir être facilement transposable à l’ensemble des systèmes d’évaluation des protections balistiques et des ALRc. La gravité du traumatisme a été définie ici par le volume de la contusion pulmonaire. L’utilisation de cette valeur nécessitait le recours au modèle animal. Or, nous avons démontré que le thorax du modèle porcin n’offrait pas le même comportement biomécanique lors de l’impact que le thorax de l’adulte jeune. Nous avons donc développé un critère, l’impulsion de pression intrathoracique maximale (PImax), basé sur la mesure de la pression intrathoracique lors de l’impact, et donc indépendant du comportement biomécanique de la paroi thoracique vis-à-vis de ses effets sur le poumon. Ce critère très bien corrélé avec le volume de la contusion pulmonaire, quelque soit le type d’impact thoracique balistique (ALRc ou BABT), a l’avantage de pouvoir être transposable aux autres moyens d’évaluations balistiques tels que les modèles numériques ou mécaniques de thorax, afin de s’affranchir de l’expérimentation animale / When non-penetrating, impacts on bulletproof jackets can lead to potentially lethal blunt injuries known as behind armor blunt trauma (BABT). Impacts of less lethal kinetic weapons (LLKW) can also lead to such injuries. To both improve the protection capabilities of the BPJ and better comprehend the ounding potential of the LLKW, we need to design a wounding criterion to predict the injury severity of ballistic blunt thoracic trauma. In one hand, this criterion has to be well correlated with the severity of the injuries, and in the other hand, it has to be easily used with all the LLKW and BPJ assessment systems in use. First, we defined the pulmonary contusion volume as the severity of the injuries. Studying the pulmonary contusion involves the use of animal experiments. But we demonstrated that the biomechanics of the chest wall are different in animals and young adults. Then, we developed the maximum pressure impulse criterion (PImax). As it is based on the intrathoracic pressure measure during the blunt impact, it is independent from the chest wall behavior. This criterion can be used with the other assessment tools as the numerical simulation mechanical chest surrogates. This can help to reduce the use of animal experiments, which is more and more expensive, heavy and questionable on the ethical aspect
2

Contusion pulmonaire : aspects physiopathologiques et conséquences thérapeutiques / Pulmonary contusion : physiopathological aspects and therapeutic consequences

Prunet, Bertrand 22 January 2015 (has links)
L’association lésionnelle d’une contusion pulmonaire et d’un état de choc hémorragique est fréquente et constitue un réel chalenge thérapeutique. La prise en charge de ce choc va nécessiter une réanimation hémodynamique dans laquelle le remplissage vasculaire tient une place centrale. Mais dans ce contexte de poumon contus, il devra être raisonné car délétère sur le plan pulmonaire, notamment en terme d'oedème et d'altération de la compliance. Ce remplissage devra donc être titré, basé sur des objectifs tensionnels clairs et un monitorage hémodynamique fiable. L'utilisation de solutés à haut pouvoir d'expansion volémique (sérum salé hypertonique, colloïdes) présente un intérêt, de même que l'introduction précoce de vasopresseurs. Le monitorage hémodynamique permettra de conduire cette réanimation sur des objectifs de pression artérielle, sur des indices de précharge dépendance et sur la mesure de l'eau pulmonaire extravasculaire. Notre travail, basé sur des études expérimentales et cliniques, a pour objectif de caractériser les modalités actuelles de prise en charge d’une contusion pulmonaire, sur les plans hémodynamiques et respiratoires. / Pulmonary contusion is often associated with hemorrhagic shock, constituting a challenge in trauma care. For patients who have sustained lung contusions, fluid resuscitation should be carefully performed, because injured lungs are particularly vulnerable to massive fluid infusions with an increased risk of pulmonary edema and compliance impairment. Fluid administration should be included in an optimized and goal directed resuscitation, based on blood pressure objectives and hemodynamical monitoring. The use of fluids with high volume-expanding capacities (hypertonic saline, colloids) is probably interesting, as well as early introduction of vasopressors. Hemodynamic monitoring will allow to conduct resuscitation on blood pressure objectives, on preload parameters and on extravascular lung water measurement.Our work, based on experimental and clinical studies, objective to characterize the current modalities of ventilatory and hemodynamical aspect of pulmonary contusion care.

Page generated in 0.0766 seconds