• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise de métodos alternativos ao uso de animais para a classificação da irritação ocular induzida por corantes têxteis / Analysis of alternative methods to the use of animals for the classification of ocular irritation induced by textile dyes

Ducas, Rafael do Nascimento 29 May 2015 (has links)
Submitted by Liliane Ferreira (ljuvencia30@gmail.com) on 2018-08-16T15:26:11Z No. of bitstreams: 2 Dissertação - Rafael do Nascimento Ducas - 2015.pdf: 1199090 bytes, checksum: 197e2d02385d6512ad213fe017f881ae (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Rejected by Luciana Ferreira (lucgeral@gmail.com), reason: Olhe a data na citação: DUCAS, R. N. Análise de métodos alternativos ao uso de animais para a classificação da irritação ocular induzida por corantes têxteis. 2015. 52 f. Dissertação (Mestrado em Ciências Farmacêuticas) - Universidade Federal de Goiás, Goiânia, 2018. on 2018-08-17T11:28:42Z (GMT) / Submitted by Liliane Ferreira (ljuvencia30@gmail.com) on 2018-08-20T11:47:43Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertação - Rafael do Nascimento Ducas - 2015.pdf: 1199090 bytes, checksum: 197e2d02385d6512ad213fe017f881ae (MD5) / Rejected by Luciana Ferreira (lucgeral@gmail.com), reason: Olhe a data da defesa na citação on 2018-08-21T11:19:58Z (GMT) / Submitted by Liliane Ferreira (ljuvencia30@gmail.com) on 2018-08-21T11:36:06Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertação - Rafael do Nascimento Ducas - 2015.pdf: 1199090 bytes, checksum: 197e2d02385d6512ad213fe017f881ae (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2018-08-22T12:39:57Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertação - Rafael do Nascimento Ducas - 2015.pdf: 1199090 bytes, checksum: 197e2d02385d6512ad213fe017f881ae (MD5) / Made available in DSpace on 2018-08-22T12:39:57Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertação - Rafael do Nascimento Ducas - 2015.pdf: 1199090 bytes, checksum: 197e2d02385d6512ad213fe017f881ae (MD5) Previous issue date: 2015-05-29 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The evaluation of the toxicity of chemicals still involves the use of animals. However, due to animal welfare and ethical values, research laboratories and regulatory agencies are working together to develop scientifically valid alternative methods. Currently, the Bovine Cornea Opacity and Permeability Test (BCOP) can be used as an alternative methodology to the Draize Test in the determination of ocular irritation and corrosion. In addition, recent data from the literature show that the association between alternative methods represents a useful tool in the evaluation of these parameters. In this context, the objective of this study was to evaluate the efficacy of the BCOP test and the Short-Term Exposure Test (STE) in determining the ocular irritation of Reactive Orange 16 (RO16) and Reactive Green 19 (RG19) based on the United Nations Globally Harmonized System of Classification (UN GHS) and in accordance with the Occupational Safety and Health Administration - Hazard Communication Standard 29 CFR 1910 (OSHA HCS), as Category 2A (eye irritant), using the in vivo test from Draize. The STE test (OECD 491) was used to evaluate cytotoxicity in SIRC cells and the BCOP (OECD 437) assay for opacity, permeability and bovine cornea histopathology. According to the STE test, the RO16 dye obtained cell viability of 47% at 5% concentration and 51% of cell viability at the concentration of 0.05%. The corange RG19 presented cell viability of 41.5% in the concentration of 5% and 44% of cell viability in the concentration of 0.05%. Thus, the dyes were classified as Category 1 of the GHS. The BCOP assay, however, classified only RG19 dye as GHS Category 1 with IVIS: 112,760. The RO16 dye resulted in an IVIS: 12.027, not being classified by this method. To complement this assay, histopathological analyzes were performed, which allowed the observation of significant loss of epithelial cells, intense cytoplasmic vacuolization and damage to the epithelial structure of the corneas exposed to RG19 dye. Although not classified by the BCOP, the corneas exposed to RO16 showed surface coating losses and cytoplasmic vacuolization. Therefore, the STE test alone was not sufficient to define the categorization of the ocular irritation potential of the dyes in relation to the GHS system, but its association with the BCOP test added by the histomorphometric analysis may be an alternative for the prediction of this effect, investigation of other dyes to confirm this fact. / A avaliação da toxicidade de produtos químicos ainda envolve o uso de animais. No entanto, devido ao bem-estar animal e valores éticos, os laboratórios de pesquisas e as agências regulatórias estão trabalhando juntos no desenvolvimento de métodos alternativos cientificamente válidos. Atualmente, o Ensaio de Opacidade e Permeabilidade da Córnea Bovina (BCOP) pode ser utilizado como metodologia alternativa ao Teste de Draize na determinação da irritação e corrosão ocular. Além disso, dados recentes da literatura demonstram que a associação entre métodos alternativos representa uma ferramenta útil na avaliação destes parâmetros. Neste contexto, o objetivo deste trabalho foi avaliar a eficácia da associação do ensaio BCOP com o Teste de Exposição de Curta Duração (STE) na determinação da irritação ocular dos corantes têxteis Reactive Orange 16 (RO16) e Reactive Green 19 (RG19), classificados com base no Sistema Globalmente Harmonizado de Classificação das Nações Unidas (UN GHS) e de acordo com a Occupational Safety & Health Administration - Hazard Communication Standard 29 CFR 1910 (OSHA HCS), como Categoria 2A (irritante para olhos), utilizando o teste in vivo de Draize. Para tanto, foram utilizados o teste STE (OECD 491) para avaliação da citotoxicidade em células SIRC e o ensaio BCOP (OECD 437) para análise da opacidade, permeabilidade e histopatologia da córnea bovina. De acordo com o teste STE, o corante RO16 obteve viabilidade celular de 47% na concentração de 5% e de 51% de viabilidade celular na concentração de 0,05%. Já o corange RG19 apresentou viabilidade celular de 41,5% na concentração de 5% e 44% de viabilidade celular na concentração de 0,05%. Assim, os corantes foram classificados como Categoria 1 do GHS. Já o ensaio BCOP classificou apenas o corante RG19 como Categoria 1 do GHS com IVIS:112,760. O corante RO16, resultou em um IVIS:12,027, não sendo classificado por este método. Para complementar esse ensaio, foram realizadas análises histopatológicas, o que permitiu observar a perda significativa de células epiteliais, a vacuolização citoplasmática intensa e danos à estrutura epitelial das córneas expostas ao corante RG19. Apesar de não ser classificado pelo BCOP, as córneas expostas ao RO16 apresentaram perdas do revestimento superficial e vacuolização citoplasmática. Portanto, o teste STE sozinho não foi suficiente para definir a categorização do potencial de irritação ocular dos corantes frente ao sistema GHS, mas a sua associação com o ensaio BCOP adicionado da análise histomorfométrica pode ser uma alternativa para a predição desse efeito, sendo necessária a investigação de outros corantes para a confirmação desse fato.

Page generated in 0.0161 seconds