Some Aspects Of Voltage Stability Improvement In Planning And Operation Of Power SystemsVisakha, K 07 1900 (has links) (PDF)
No description available.
|
2 |
Investigation and Model Development for Operational Modes of a Unified Power Flow ControllerMahmoodianfard, Forough 30 November 2012 (has links)
The focus of this research is on deriving small signal stability models for different Flexible AC Transmission Systems devices by introducing a simple systematic method that is applicable to any dynamic device.
Two different small signal models for Unified Power Flow Controllers are introduced. One model is called the power control mode and the other model is the voltage control mode. The two models are compared from transient stability point of view to show the necessity of developing both models for UPFC.
The thesis also shows how to derive the small signal stability model of Static Synchronous Compensator, as the shunt branch of UPFC. The small signal stability models of both devices are then validated to ensure the accuracy of the derived models. STATCOM and UPFC power control mode are validated against PSCAD. The UPFC voltage control mode is validated against nonlinear solution of system equations.
|
3 |
Investigation and Model Development for Operational Modes of a Unified Power Flow ControllerMahmoodianfard, Forough 30 November 2012 (has links)
The focus of this research is on deriving small signal stability models for different Flexible AC Transmission Systems devices by introducing a simple systematic method that is applicable to any dynamic device.
Two different small signal models for Unified Power Flow Controllers are introduced. One model is called the power control mode and the other model is the voltage control mode. The two models are compared from transient stability point of view to show the necessity of developing both models for UPFC.
The thesis also shows how to derive the small signal stability model of Static Synchronous Compensator, as the shunt branch of UPFC. The small signal stability models of both devices are then validated to ensure the accuracy of the derived models. STATCOM and UPFC power control mode are validated against PSCAD. The UPFC voltage control mode is validated against nonlinear solution of system equations.
|
4 |
Investigation of the application of UPFC controllers for weak bus systems subjected to fault conditions : an investigation of the behaviour of a UPFC controller : the voltage stability and power transfer capability of the network and the effect of the position of unsymmetrical fault conditionsJalboub, Mohamed January 2012 (has links)
In order to identify the weakest bus in a power system so that the Unified Power Flow Controller could be connected, an investigation of static and dynamic voltage stability is presented. Two stability indices, static and dynamic, have been proposed in the thesis. Multi-Input Multi-Output (MIMO) analysis has been used for the dynamic stability analysis. Results based on the Western System Coordinate Council (WSCC) 3-machine, 9-bus test system and IEEE 14 bus Reliability Test System (RTS) shows that these indices detect with the degree of accuracy the weakest bus, the weakest line and the voltage stability margin in the test system before suffering from voltage collapse. Recently, Flexible Alternating Current Transmission systems (FACTs) have become significant due to the need to strengthen existing power systems. The UPFC has been identified in literature as the most comprehensive and complex FACTs equipment that has emerged for the control and optimization of power flow in AC transmission systems. Significant research has been done on the UPFC. However, the extent of UPFC capability, connected to the weakest bus in maintaining the power flows under fault conditions, not only in the line where it is installed, but also in adjacent parallel lines, remains to be studied. In the literature, it has normally been assumed the UPFC is disconnected during a fault period. In this investigation it has been shown that fault conditions can affect the UPFC significantly, even if it occurred on far buses of the power system. This forms the main contribution presented in this thesis. The impact of UPFC in minimizing the disturbances in voltages, currents and power flows under fault conditions are investigated. The WSCC 3-machine, 9-bus test system is used to investigate the effect of an unsymmetrical fault type and position on the operation of UPFC controller in accordance to the G59 protection, stability and regulation. Results show that it is necessary to disconnect the UPFC controller from the power system during unsymmetrical fault conditions.
|
5 |
Investigations On Small Signal Stability Of Power Systems Affected By FACTS Supplementary Modulation ControllersSaikumar, H V 09 1900 (has links) (PDF)
No description available.
|
6 |
Performance Evaluation Of Distance Relays For FACTS Compensated Transmission LinesMaturu, Suresh 03 1900 (has links) (PDF)
With limited enhancement or expansion of the transmission infrastructure, the contemporary power systems are operating under more stressed conditions. It becomes important to fully utilize the existing transmission system to supply load demand as much as possible, thus eliminating or reducing the need for new transmission investment.
Flexible AC Transmission System (FACTS) technology provides an alternative to fully utilize the existing transmission lines as well as new and upgraded lines, by controlling power and also enhancing the power transfer capability of transmission lines. However, the implementation of FACTS controllers in the transmission system has introduced new power system dynamics that must be addressed in the area of power system protection, such as rapid changes in line impedance, power angle, line currents, transients introduced by the occurrence of fault and associated control action of the FACTS controller. Therefore, the performance of the protection system must be carefully analyzed in the presence of FACTS controllers.
The thesis aims at evaluating the performance of distance relays when different types of FACTS controllers, in particular Voltage Source Converter (VSC) based FACTS controllers, are incorporated at the midpoint of the transmission system to achieve voltage profile improvement and power transfer capability. The detailed models of these controllers and their control strategies are described. The presence of FACTS controllers in the loop affects both steady state and transient components of voltage and current signals. The rapid response of FACTS controllers to different power system configurations significantly affects the apparent impedance seen by distance relays. The apparent impedance seen by distance relays would be different from that of the system without FACTS controller. Due to this, the distance relay may malfunction, resulting in unreliable operation of the power system during faults. Furthermore, the effect of FACTS controllers on distance relay operation depends on the type of FACTS controller used, the application for which it has been installed and its location in the power system. The distance relay is evaluated for different loading conditions and for various fault conditions. Simulation studies are carried out using PSCAD/EMTDC based transient simulation package.
|
7 |
Investigation of the application of UPFC controllers for weak bus systems subjected to fault conditions. An investigation of the behaviour of a UPFC controller: the voltage stability and power transfer capability of the network and the effect of the position of unsymmetrical fault conditions.Jalboub, Mohamed K. January 2012 (has links)
In order to identify the weakest bus in a power system so that the Unified Power Flow Controller could be connected, an investigation of static and dynamic voltage stability is presented. Two stability indices, static and dynamic, have been proposed in the thesis. Multi-Input Multi-Output (MIMO) analysis has been used for the dynamic stability analysis. Results based on the Western System Coordinate Council (WSCC) 3-machine, 9-bus test system and IEEE 14 bus Reliability Test System (RTS) shows that these indices detect with the degree of accuracy the weakest bus, the weakest line and the voltage stability margin in the test system before suffering from voltage collapse.
Recently, Flexible Alternating Current Transmission systems (FACTs) have become significant due to the need to strengthen existing power systems. The UPFC has been identified in literature as the most comprehensive and complex FACTs equipment that has emerged for the control and optimization of power flow in AC transmission systems. Significant research has been done on the UPFC. However, the extent of UPFC capability, connected to the weakest bus in maintaining the power flows under fault conditions, not only in the line where it is installed, but also in adjacent parallel lines, remains to be studied. In the literature, it has normally been assumed the UPFC is disconnected during a fault period. In this investigation it has been shown that fault conditions can affect the UPFC significantly, even if it occurred on far buses of the power system. This forms the main contribution presented in this thesis. The impact of UPFC in minimizing the disturbances in voltages, currents and power flows under fault conditions are investigated. The WSCC 3-machine, 9-bus test system is used to investigate the effect of an unsymmetrical fault type and position on the operation of UPFC controller in accordance to the G59 protection, stability and regulation. Results show that it is necessary to disconnect the UPFC controller from the power system during unsymmetrical fault conditions. / Libyan Government
|
8 |
Analysis Of SubSynchronous Resonance With Voltage Source Converter Based FACTS And HVDC ControllersNagesh Prabhu, * 09 1900 (has links) (PDF)
No description available.
|
9 |
Planning And Operational Aspects Of Real And Reactive Power In Deregulated Power SystemsChintamani, Vyjayanthi 09 1900 (has links) (PDF)
The transition of the power sector from vertically integrated utility (VIU) to deregulated system has resulted in reshaping of generation, transmission and distribution components. Some of the objectives of restructuring are to ensure a secure and reliable supply of electricity, encourage competition in all segments, sustain future economic and technological growth, etc. There are many challenges that arise in fulfilling these objectives.
The thesis addresses some of them related to planning and operational aspects of real and reactive power, covering the following areas:
Real power tracing, loss allocation and pricing
Reactive power tracing, loss allocation and pricing
Power system generation expansion planning
Power transfer capability in interregional grids
Voltage stability enhancement by improving reactive power margins
In deregulated power systems, it has become important to identify the generation and transmission entities responsible in meeting loads. This is done by tracing the power flows through the transmission network. Power tracing is required to assess the extent of network usage by the participants, so as to allocate the transmission losses and charges. Many loss allocation methods are presented in the literature. The loss allocation method implemented in this thesis is a circuit based method. For obtaining the generators contribution towards meeting system loads and transmission losses, an approach of relative electrical distance (RED) between the generation and the load buses, is presented. The method is used to trace both real and reactive power flows.
In the case of real power, the generators are the only sources and loads are the only sinks. However, reactive sources and sinks are distributed all along the transmission system. The reactive power sources considered are generators, switchable VAR sources (shunt capacitor banks) and line charging susceptances; and the reactive sinks are shunt reactors and reactive inductive loads. While tracing their flows the actual sources or sinks are to be identified which is obtained after adding reactive injections and absorptions at each bus. If the net value is absorbing, the bus is a reactive sink and if the net value is injecting, the bus is a reactive source. The transmission line charge susceptances contribution to the system’s reactive flows; and its aid extended in reducing the reactive generation at the generator buses is also discussed. A reactive power optimization technique is applied to optimally adjust the reactive controller settings of transformer taps, generator excitations and switched capacitors, so that the available reactive resources can be fully utilized. In the thesis, a methodology for evaluation of real and reactive power load and loss sharing proportions; and cost allocation towards transmission utilization is presented.
Due to the ever growing increase in demands; on one hand the existing transmission networks are getting overloaded at some locations and on the other hand, the available generation is becoming insufficient to cater to the additional demand. To handle this problem, generation and transmission expansions become inevitable. Hence, additional public sector units or independent power producers and transmission providers are to be brought in. However in a restructured system, generally there is no central planning for new generation capacity or transmission additions. The reason being, these investments need huge capital and long period of commitment. While making a generation investment decision, expectations concerning future electricity demand, spot market prices, variations of regulatory policies, etc., are the major considerations. The locations, capacities and timing of new power plants are basically at the generation companies’ own discretion. Also, generation companies do not have any obligation to ensure sufficient supply of electricity to meet present and future requirements. Hence, it is a matter of concern as to how adequate generation capacity can be secured in the long run. Optimal siting and sizing of these new generation locations is also an issue of concern. In this thesis a new index called as ‘Tindex’ is proposed, which identifies prospective new generation expansion locations. The index is formulated based on the transmission network information, and it helps in identifying the most suitable new generation expansion locations. To implement this methodology each of the load bus is treated as a generation bus, one at a time, and the maximum generation capacity that can be installed at the location is computed from the approach. This method ensures minimum transmission expansion.
Interconnected power systems help in exchanging power from one area to other areas at times of power deficiency in their own area. To enable this, their tieline capability to transfer power has to be sufficient, which is determined using total transfer capability (TTC) computation. TTC is an important index in power markets with large volume of interarea power exchanges and wheeling transactions taking place on an hourly basis. In the thesis, the total transfer capability (TTC) of interconnected tielines, under normal and contingency conditions is evaluated. The contingency cases evaluated are single line contingency, tieline contingency and generator outage. The most critical lines in each zone are identified using Fuzzy set theory. Unified power flow controller (UPFC), a flexible AC transmission system (FACTS) device is incorporated to improve the power transfers under contingency conditions. The best locations for UPFC placement are identified by analysing the power flow results obtained after considering the contingencies. For each of the normal and contingency cases, a base case and a limiting case are formed and the TTC is evaluated. Limiting case is formed by increasing the load in small steps till a point after which bus voltages or line loadings start to violate their stability constraints. To improve the system conditions in the limiting case, reactive power optimization and UPFC installation is carried out. The results reflect the improvement in system conditions and total transfer capability margins.
Availability of sufficient generator reactive margins is very essential to ensure system’s voltage stability, without which even minor disturbances may lead to catastrophe. The amount of reactive power margin available in a system determines its proximity to voltage instability under normal and emergency conditions. One way of improving the reactive margin of a synchronous generator, is to reduce the real power generation within its MVA ratings. However this real power reduction will affect the real power contract agreements formed while power trading. The real power contracts are not disturbed and the reactive power margins are improved by optimally adjusting the other available reactive controllers, namely, generator exciter, transformer taps and shunt compensators. To have further control on the reactive flows, UPFC device is incorporated at appropriate locations. The thesis discusses how reactive margins are computed and subsequently improved using a reactive power optimization technique and UPFC.
Case studies are carried out on typical sample 6bus, 8bus, 10bus, 16bus, 20bus, IEEE 30bus, IEEE 39bus systems, and reallife equivalents of Indian southern grid 24bus, 72bus, 87bus and 205bus systems to illustrate the proposed approaches.
|