• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Characteristics of tropical tropopause and stratospheric gravity waves analyzed using high resolution temperature profiles from GNSS radio occultation / GNSS掩蔽による高分解能温度プロファイルを用いて解析された熱帯対流圏界面と成層圏重力波の特性

Noersomadi 25 March 2019 (has links)
京都大学 / 0048 / 新制・課程博士 / 博士(理学) / 甲第21579号 / 理博第4486号 / 新制||理||1644(附属図書館) / 京都大学大学院理学研究科地球惑星科学専攻 / (主査)教授 橋口 浩之, 教授 塩谷 雅人, 教授 秋友 和典 / 学位規則第4条第1項該当 / Doctor of Science / Kyoto University / DGAM
2

Konvektivní bouře a vodní pára ve spodní stratosféře / Convective storms and lower stratospheric moisture

Šťástka, Jindřich January 2018 (has links)
Title: Convective storms and lower stratospheric moisture Author: Jindřich Šťástka Department: Department of Atmospheric Physics Supervisor: RNDr. Martin Setvák, CSc., Czech Hydrometeorological Institute Abstract: The primary focus of this thesis is to diagnose contributions to upper tropo- spheric and lower stratospheric (UTLS) water vapor from convective storms. The first parts of this work introduces two approaches used for a detection of lower stratospheric water vapor above convective storm tops - brightness temperature difference (BTD) technique and EOS MLS measurements. The BTD technique is based on brightness temperature difference between the water vapor absorp- tion and infrared window bands, assuming a thermal inversion above the cloud top level. The most frequently offered explanation of positive BTD values above convective storms is presence of warmer water vapor in the lower stratosphere. Furthermore, so called BTD anomalies were described and it was proposed an algorithm for objective detection of such BTD anomalies. Characteristics of pa- rameters describing BTD, BTD anomaly, infrared window brightness temperature were investigated during storms evolution on dataset of 320 storms from the area of Europe. The analysis of these characteristics proved highly probable conection between positive...
3

An optical particle counter for the regular application onboard a passenger aircraft: instrument modification, characterization and results from the first year of operation

Weigelt, Andreas 28 May 2015 (has links)
To understand the contribution of aerosol particles to radiative forcing and heterogeneous chemical processes in the upper troposphere and lowermost stratosphere (UT/LMS), the knowledge of the particle size distribution is mandatory. Unfortunately, measurements in the UT/LMS are costly. Research aircrafts are expensive and thus their application is limited in time and space. Satellite remote sensing measurements provide a good temporal and spatial (horizontal) coverage, but only a limited vertical resolution and currently cannot resolve the particle size distribution. Therefore, within this thesis an optical particle counter (OPC) unit was modified for the application onboard a passenger long-haul aircraft within the CARIBIC project (www.caribic-atmospheric.com). The CARIBIC OPC unit provides regular and cost-efficient particle size distribution measurements of accumulation mode particles in the UT/LMS. In April 2010, the new OPC unit was installed for the first time onboard the Lufthansa Airbus A340 600 (D-AIHE) for the measurement of the volcanic ash cloud from the Eyjafjallajökull eruption (April to May 2010). Since June 2010 the OPC unit measures on usually four intercontinental flights per month the UT/LMS particle size distribution in the particle size range 125 to 1300 nm particle diameter. As the data acquisition stores the scattering raw signal and all housekeeping data as well, during the post flight data analysis the temporal- and size channel resolution can be flexible set. Within this work the data were analyzed with 32 size channels and 300 seconds. As aircraft-borne measurements are always time-consuming, the development of the OPC unit and the analysis routine, as well as its characterization and certification took more than two thirds of the total working time of this thesis. Therefore, the analysis of the data is limited to the first year of regular measurements until May 2011. Nevertheless, this dataset is sufficient to demonstrate the scientific relevance of these measurements. To validate the OPC data, a comparison to particle size distributions measured from board research aircraft was carried out. The analysis of the volcanic ash flights in April and May 2010 showed strongly enhanced particle mass concentrations inside the plumes and agreed in some regions very well to the particle mass concentration predicted by a dispersion model. A further case study shows the occurrence of a surprising large (1000 km) and high concentrated pollution plume over eastern Asia close to Osaka (Japan). Inside the plume the highest particle number- and mass concentrations measured with the OPC unit in the analysis period were observed (except volcanic ash flights). A detailed analysis of the in parallel measured trace gasses as well as meteorological- and LIDAR data showed, the observed plume originate from biomass burning and industrial emissions in eastern China. A third case study gives a first attempt of a mass closure/validation between the particle masses derived by the CARIBIC OPC unit and the CARIBIC impactor particle samples. First statistical analyses to the vertical, meridional, and seasonal variation of the accumulation mode particle size distribution and therefrom derived parameter indicate a stratospheric vertical increasing gradient for the particle number- and mass concentration. In general in the mid-latitude LMS the concentration of accumulation mode particles was found to be on average 120% higher than in the mid-latitude UT. The mid-latitude LMS particle size distribution shows a seasonal variation with on average 120% higher concentrations during spring compared to fall. This results can be explained with general dynamics in the stratosphere (Brewer-Dobson Circulation) and in the tropopause region (stratosphere-troposphere-exchange, STE). An anti-correlation of gaseous mercury to the stratospheric particle surface area concentration (R²=0.97) indicates that most likely stratospheric aerosol particles do act as a sink for gaseous mercury. Finally, two comparisons of the OPC data to data from satellite remote sensing and a global aerosol model underline the OPC potential and the benefits of creating an in situ measured reference dataset. / Um die Rolle von Aerosolpartikeln beim Strahlungsantrieb und der heterogenen chemischen Prozessen in der oberen Troposphäre und untersten Stratosphäre (OT/US) verstehen zu können, ist es unabdingbar die Partikelgrößenverteilung zu kennen. Messungen der Partikelgrößenverteilung in dieser Region sind allerdings aufwendig. Der Einsatz von Forschungsflugzeugen ist teuer und deshalb zeitlich und räumlich nur begrenzt. Satellitenmessungen bieten zwar eine gute zeitliche und räumliche (horizontal) Abdeckung, aber nur eine begrenzte vertikale Auflösung. Weiterhin können bisherige Satellitenmessungen die Partikelgrößenverteilung nicht auflösen. Im Rahmen dieser Arbeit wurde deshalb ein optischer Partikelzähler (OPC) Messeinschub für den Einsatz an Bord eines Langstrecken-Passagierflugzeugs aufgebaut (CARIBIC Projekt, www.caribic-atmospheric.com). Mit diesem Messeinschub kann regelmäßig und kosteneffizient die Partikelgrößenverteilung des Akkumulationsmodes in der OT/US gemessen werden. Im April 2010 wurde der neue OPC Einschub erstmals an Bord des Lufthansa Airbus A340-600 (D-AIHE) installiert um die Vulkanasche der Eyjafjallajökull Eruption (April bis Mai 2010) zu messen. Seit Juni 2010 misst der OPC Einschub auf durchschnittlich vier Interkontinentalflügen pro Monat die Partikelgrößenverteilung der OT/US im Größenbereich zwischen 125 und 1300 nm Partikeldurchmesser. Während des Fluges speichert die Datenerfassung alle Rohsignale ab und ermöglicht dadurch eine nutzerspezifische Datenauswertung nach dem Flug (z. B. Anzahl der Größenkanäle oder Zeitauflösung). Im Rahmen dieser Arbeit wurden die Daten mit 32 Größenkanälen und 300 Sekunden analysiert. Da fluggetragene Messungen immer sehr aufwendig sind, beanspruchte die Entwicklung des OPC Einschubs und des Analysealgorithmus, sowie die Charakterisierung und Zertifizierung mehr als zwei Drittel der Gesamtarbeitszeit dieser Arbeit. Daher ist die Analyse der Messdaten auf das erste Jahr der regulären Messungen bis Mai 2011 beschränkt. Dennoch ist dieser Datensatz geeignet um die wissenschaftliche Relevanz dieser Messungen zu demonstrieren. Um die OPC-Daten zu validieren, wurde ein Vergleich mit bisherigen OPC Messungen von Bord Forschungsflugzeugen durchgeführt. Die Analyse der Vulkanascheflüge im April und Mai 2010 zeigte in der Abluftfahne stark erhöhte Partikelmassekonzentrationen, welche in einigen Vergleichsregionen sehr gut mit der Vorhersage eines Disperionsmodells übereinstimmten. Eine weitere Fallstudie zeigt das Auftreten einer überraschend großen (1000 km) und hoch konzentrierten Abluftfahne über Ostasien nahe Osaka (Japan). In der Abluftfahne wurde die im Analysezeitraum höchste mit dem CARIBIC OPC gemessene Partikelanzahl- und Massenkonzentration beobachtet (ausgenommen Vulkanascheflüge). Eine detaillierte Analyse der parallel gemessenen Spurengase, sowie meteorologischer Daten und LIDAR Profile zeigte, dass die beobachtete Abluftfahne eine Mischung aus Biomasseverbrennungs- und Industrieabgasen aus Ost-China war. Eine dritte Fallstudie stellt einen ersten Versuch einer Massenschließung/Validierung zwischen der aus den CARIBIC OPC-Daten abgeleiteten Partikelmasse und der Partikelmasse aus CARIBIC Impaktorproben dar. Erste statistische Analysen zur vertikalen, meridionalen und saisonalen Variabilität der Partikelgrößenverteilung im Akkumulationsmode und daraus abgeleiteten Parametern zeigen einen vertikal ansteigenden Gradienten für die Partikelanzahl- und Massenkonzentration. Generell war in der US der mittleren Breiten die Konzentration von Akkumulationsmode Partikeln im Mittel um 120% höher als in der OT der mittleren Breiten. Weiterhin wurde in der US der mittleren Breiten eine jahreszeitliche Schwankung gefunden. Im Frühling war die mit dem OPC gemessene Partikelkonzentrationen im Mittel um 120% höher als im Herbst. Diese Befunde lassen sich mit der atmosphärischen Dynamik in der Stratosphäre (Brewer-Dobson Zirkulation) und in der Tropopausenregion (Stratosphäre-Troposphäre-Austauschprozesse) erklären. Eine gefundene negative Korrelation von gasförmigen Quecksilber mit der stratosphärischen Partikeloberflächenkonzentration (R²=0.97) ist ein starker Indikator dafür, dass in der US Aerosolpartikel eine Senke für gasförmiges Quecksilber darstellen. Zum Abschluss unterstreichen zwei Vergleiche der OPC-Daten mit Satellitenmessungen und Ergebnissen eines globalen Aerosolmodels das Potential und den Nutzen der CARIBIC OPC Daten als in-situ gemessenen Referenzdatensatz.

Page generated in 0.1041 seconds