• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • Tagged with
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estimativa de recarga em áreas urbanizadas: estudo de caso na bacia do Alto Tietê (SP) / Recharge estimate in urbanized areas: case study in the Upper Tietê watershed (SP)

Viviani-Lima, Juliana Baitz 19 December 2007 (has links)
A Bacia do Alto Tietê (BAT) abriga uma população de 19,5 milhões de pessoas numa área de 5.985 km2, correspondendo aproximadamente ao contorno da região Metropolitana de São Paulo (RMSP). A BAT é composta por dois sistemas aqüíferos principais: o Sistema Aqüífero Sedimentar (SAS) (1.452 km2) e o Sistema Aqüífero Cristalino (CAS) (4.238 km2). A importância da água subterrânea na RMSP tem crescido significativamente nos últimos 20 anos. Diversas indústrias e condomínios têm utilizado a água subterrânea como fonte complementar e muitas vezes exclusive de abastecimento de água, extraindo um volume que corresponde a cerca de 13% do volume total de água distribuído pelas companhias de abastecimento público. Apesar de sua importância, pouco se sabe sobre a qualidade e quantidade de água que abastece esses sistemas aqüíferos. Além disso, em áreas urbanas, a influência antrópica causa mudanças aos padrões de recarga natural dos sistemas aqüíferos. Este estudo teve os seguintes objetivos: i) estimar a recarga no SAS em duas áreas com diferentes padrões de ocupação urbana (alta e baixa densidade de impermeabilização), utilizando diferentes métodos (flutuação dos níveis de água, aproximações darcinianas, hidroquímica, isótopos estáveis); e ii) determinar a origem da água de recarga (vazamentos do sistema de água e esgoto ou infiltração natural de chuva). Os períodos mais chuvosos e mais secos para ambas as áreas foi janeiro e agosto, respectivamente, e a precipitação total para a área menos urbanizada. O método de flutuação dos níveis de água estimou um valor de recarga natural para a área menos urbanizada de 246 mm/a e 183 mm/a para a área densamente urbanizada. Um valor de 481 mm/a foi obtido pelas aproximações darcinianas para a área mais urbanizada e 311 mm/a para a área menos urbanizada e, se as estimativas forem precisas, a diferença entre os resultados dos diferentes métodos indica a soma das fontes de recarga antrópicas (respectivamente 298 mm/a e 65 mm/a). A análise dos dados químicos de Na+, Cl-, NO3 -, NH4 + e SO42- demonstrou a presença de vazamentos extensivos do sistema de esgoto em ambas as áreas. Os resultados dos isótopos em NO3 - para a área urbanizada (enriquecimento de ?15N e ?18O) e dados químicos (DOC, HCO3-) indicam que a desnitrificação tem papel importante na atenuação do nitrato no aqüífero. Os dados de níveis de água, da zona não saturada e isótopos ambientais indicam que chuvas menores que 20 mm/dia ou 100 mm/mês não são capazes de recarregar o aqüífero. Os dados de ?18O e ? 2H coletados em ambas as áreas apresentam-se sobre uma linha de mistura entre as assinaturas da chuva (maior que 100 mm/mês) e água do sistema de abastecimento público, indicando a contribuição destas fontes distintas na recarga dos aqüíferos (contribuição urbana de 14% na recarga da área menos urbanizada e 67% na área mais urbanizada, corroborando os resultados dos outros métodos). Os dados obtidos neste estudo indicam que vazamentos do sistema de esgoto e de água de abastecimento têm papel fundamental na recarga do aqüífero e na qualidade da água subterrânea. / The Upper Tiete Watershed (UTW) has a population of 19.5 million in an area of 5,985 km2, which corresponds approximately to the contour of the Metropolitan Region of Sao Paulo (MRSP), Brazil. The UTW is comprised of two major aquifer systems: the Sedimentary Aquifer System (SAS) (1,452 km2) and the Crystalline Aquifer System (CAS) (4,238 km2). The importance of groundwater in the MRSP has increased substantially during the last 20 years. Several industries and condominiums are using groundwater as a complementary and often exclusive source of water supply, extracting a volume that corresponds to approximately 13% of the total volume of water distributed by the public supply companies. Despite their importance, not much is known about the quality and quantity of the water that recharge these aquifer systems. Besides, in urban areas, the anthropogenic influence causes changes to the natural water recharge patterns of the aquifer systems. This study had the following objectives: i) estimating the recharge of the SAS in two areas with different land use patterns (high and low density of paved surfaces), using different methods (water table fluctuation, Darcyan approach, hydrochemistry, environmental isotopes); and ii) determining the origin of the recharge water (leakage of supply water and sewerage system or natural infiltration of rainfall). The rainiest and driest months for both areas were January and August, respectively, and the total precipitation for the densely paved area was 1,193 mm and 1,407 mm for the least-paved area. The water table fluctuation methodology estimated that natural recharge for the poorly urbanized area is 246 mm/a and 183 mm/a for the densely urbanized area. A value of 481 mm/a was obtained through the Darcyan approach for the more urbanized area and 311 mm/a for the less urbanized area and, if the estimations are accurate, the difference between the results of the different methods indicates the sum of the anthropogenic recharge sources (respectively 298 mm/a and 65 mm/a). Analysis of chemical data for Na+, Cl-, NO3 -, NH4 + and SO42- showed the presence of extensive sewerage leakage in both areas. Results from isotopes in NO3- for the urbanized area (enrichment of ?15N and ?18O) and chemical data (DOC, HCO3-) indicated that denitrification plays an important role in attenuating the nitrate in the aquifer. The data from water levels, the unsaturated zone and environmental isotopes indicate that rainfall volumes lower than 20 mm/day or 100 mm/month are not able to recharge the aquifer. Data from ?18O and ? 2H collected in both areas lie on a mixing line between the fingerprints of precipitation water (higher than 100 mm/month) and water from the public supply system, indicating the contribution of these distinct sources to the recharge of the aquifers (urban contribution of 14% for the recharge of the less urbanized area and 67% in the more urbanized area, corroborating the results of other methods). The data obtained in this study indicates that leakage of the sewage and water distribution system plays a major role in the recharge of the aquifer and groundwater quality.
2

Estimativa de recarga em áreas urbanizadas: estudo de caso na bacia do Alto Tietê (SP) / Recharge estimate in urbanized areas: case study in the Upper Tietê watershed (SP)

Juliana Baitz Viviani-Lima 19 December 2007 (has links)
A Bacia do Alto Tietê (BAT) abriga uma população de 19,5 milhões de pessoas numa área de 5.985 km2, correspondendo aproximadamente ao contorno da região Metropolitana de São Paulo (RMSP). A BAT é composta por dois sistemas aqüíferos principais: o Sistema Aqüífero Sedimentar (SAS) (1.452 km2) e o Sistema Aqüífero Cristalino (CAS) (4.238 km2). A importância da água subterrânea na RMSP tem crescido significativamente nos últimos 20 anos. Diversas indústrias e condomínios têm utilizado a água subterrânea como fonte complementar e muitas vezes exclusive de abastecimento de água, extraindo um volume que corresponde a cerca de 13% do volume total de água distribuído pelas companhias de abastecimento público. Apesar de sua importância, pouco se sabe sobre a qualidade e quantidade de água que abastece esses sistemas aqüíferos. Além disso, em áreas urbanas, a influência antrópica causa mudanças aos padrões de recarga natural dos sistemas aqüíferos. Este estudo teve os seguintes objetivos: i) estimar a recarga no SAS em duas áreas com diferentes padrões de ocupação urbana (alta e baixa densidade de impermeabilização), utilizando diferentes métodos (flutuação dos níveis de água, aproximações darcinianas, hidroquímica, isótopos estáveis); e ii) determinar a origem da água de recarga (vazamentos do sistema de água e esgoto ou infiltração natural de chuva). Os períodos mais chuvosos e mais secos para ambas as áreas foi janeiro e agosto, respectivamente, e a precipitação total para a área menos urbanizada. O método de flutuação dos níveis de água estimou um valor de recarga natural para a área menos urbanizada de 246 mm/a e 183 mm/a para a área densamente urbanizada. Um valor de 481 mm/a foi obtido pelas aproximações darcinianas para a área mais urbanizada e 311 mm/a para a área menos urbanizada e, se as estimativas forem precisas, a diferença entre os resultados dos diferentes métodos indica a soma das fontes de recarga antrópicas (respectivamente 298 mm/a e 65 mm/a). A análise dos dados químicos de Na+, Cl-, NO3 -, NH4 + e SO42- demonstrou a presença de vazamentos extensivos do sistema de esgoto em ambas as áreas. Os resultados dos isótopos em NO3 - para a área urbanizada (enriquecimento de ?15N e ?18O) e dados químicos (DOC, HCO3-) indicam que a desnitrificação tem papel importante na atenuação do nitrato no aqüífero. Os dados de níveis de água, da zona não saturada e isótopos ambientais indicam que chuvas menores que 20 mm/dia ou 100 mm/mês não são capazes de recarregar o aqüífero. Os dados de ?18O e ? 2H coletados em ambas as áreas apresentam-se sobre uma linha de mistura entre as assinaturas da chuva (maior que 100 mm/mês) e água do sistema de abastecimento público, indicando a contribuição destas fontes distintas na recarga dos aqüíferos (contribuição urbana de 14% na recarga da área menos urbanizada e 67% na área mais urbanizada, corroborando os resultados dos outros métodos). Os dados obtidos neste estudo indicam que vazamentos do sistema de esgoto e de água de abastecimento têm papel fundamental na recarga do aqüífero e na qualidade da água subterrânea. / The Upper Tiete Watershed (UTW) has a population of 19.5 million in an area of 5,985 km2, which corresponds approximately to the contour of the Metropolitan Region of Sao Paulo (MRSP), Brazil. The UTW is comprised of two major aquifer systems: the Sedimentary Aquifer System (SAS) (1,452 km2) and the Crystalline Aquifer System (CAS) (4,238 km2). The importance of groundwater in the MRSP has increased substantially during the last 20 years. Several industries and condominiums are using groundwater as a complementary and often exclusive source of water supply, extracting a volume that corresponds to approximately 13% of the total volume of water distributed by the public supply companies. Despite their importance, not much is known about the quality and quantity of the water that recharge these aquifer systems. Besides, in urban areas, the anthropogenic influence causes changes to the natural water recharge patterns of the aquifer systems. This study had the following objectives: i) estimating the recharge of the SAS in two areas with different land use patterns (high and low density of paved surfaces), using different methods (water table fluctuation, Darcyan approach, hydrochemistry, environmental isotopes); and ii) determining the origin of the recharge water (leakage of supply water and sewerage system or natural infiltration of rainfall). The rainiest and driest months for both areas were January and August, respectively, and the total precipitation for the densely paved area was 1,193 mm and 1,407 mm for the least-paved area. The water table fluctuation methodology estimated that natural recharge for the poorly urbanized area is 246 mm/a and 183 mm/a for the densely urbanized area. A value of 481 mm/a was obtained through the Darcyan approach for the more urbanized area and 311 mm/a for the less urbanized area and, if the estimations are accurate, the difference between the results of the different methods indicates the sum of the anthropogenic recharge sources (respectively 298 mm/a and 65 mm/a). Analysis of chemical data for Na+, Cl-, NO3 -, NH4 + and SO42- showed the presence of extensive sewerage leakage in both areas. Results from isotopes in NO3- for the urbanized area (enrichment of ?15N and ?18O) and chemical data (DOC, HCO3-) indicated that denitrification plays an important role in attenuating the nitrate in the aquifer. The data from water levels, the unsaturated zone and environmental isotopes indicate that rainfall volumes lower than 20 mm/day or 100 mm/month are not able to recharge the aquifer. Data from ?18O and ? 2H collected in both areas lie on a mixing line between the fingerprints of precipitation water (higher than 100 mm/month) and water from the public supply system, indicating the contribution of these distinct sources to the recharge of the aquifers (urban contribution of 14% for the recharge of the less urbanized area and 67% in the more urbanized area, corroborating the results of other methods). The data obtained in this study indicates that leakage of the sewage and water distribution system plays a major role in the recharge of the aquifer and groundwater quality.
3

Impacts des ouvrages souterrains sur l’eau souterraine urbaine : Application à l’agglomération lyonnais / Impact of underground structures on urban groundwater : Example of Lyon, France

Attard, Guillaume 19 January 2017 (has links)
Le sous-sol urbain est aujourd’hui reconnu comme un espace riche en ressources, espace disponible, eau, géo-matériaux et géothermie jouant un rôle fondamental dans l’aménagement durable des territoires mais dont la réglementation reste lacunaire. Dans un contexte de développement urbain vertical, l’eau souterraine peut être impactée. L’objectif de la thèse est de développer une compréhension quantitative des impacts des ouvrages souterrains sur l’ eau souterraine urbaine afin de proposer des éléments d’aide à la décision destinés aux aménageurs du territoire. Ces travaux de thèse ont permis d’améliorer la compréhension du rôle joué par différents types ouvrages souterrains à une échelle de prise de décision. Les résultats montrent que les ouvrages impliquant des systèmes de pompages sont responsables d’une fragmentation des systèmes d’écoulement. Dans des conditions de faible gradient hydraulique, les ouvrages imperméables ont un impact marginal sur la position de la surface libre. Le comportement hydrodispersif des ouvrages a également été étudié et un effet de mélange dispersif a été mis en évidence au droit des ouvrages souterrains. Il favorise la migration verticale des contaminations urbaines. L’impact des ouvrages souterrains sur la temperature de l’eau souterraine urbaine a également été étudié. Le transfert de thermique entre les ouvrages et l’aquifère urbain a été quantifié et a mis en évidence l’ampleur des zones thermiquement impactées. Enfin, la compréhension des impacts des aménagements souterrains sur l’eau souterraine urbaine a permis de formuler des recommandations afin de prévenir les risques et nuisances inhérents à la construction de nouveaux ouvrages : risque d’inondation par remontée de nappe, risque d’altération qualitative de la ressource, menace et opportunité vis-à-vis du potentiel géothermique d’un aquifère urbain. / Urban subsoil provides space, groundwater, geothermal energy and geomaterials, and the importance underlying the management of this strategic space is well-known. In the context of vertical urban growth, groundwater management, is a crucial issue. The aim of the PhD thesis was to improve the knowledge related to the impacts caused by underground structures on groundwater resource in order to provide a basis for the decision making dedicated to urban planners. The understanding of the role played by numerous types of underground structures was improved at the decision-making scale. Underground structures involving pumping devices were shown to be responsible for the fragmentation of flow systems, which can modify the urban groundwater regime. Under low gradient conditions, impervious structures were confirmed to have a nonsignificant effect on water table elevation. Regarding quality, reservoir theory was applied to assess the impact of underground structures on groundwater quality. This theory allows to take into account the advective and dispersive part of groundwater flow. A dispersive piston effect is shown to occur under the structures, favoring the vertical spreading of pollutants. In addition, the impacts of underground structures on urban groundwater temperature were investigated. The annual heat from underground structures were computed deterministically, highlighting the significant thermally affected zones. Finally, the impacts of underground structures on groundwater flow quality and temperatures were analyzed in order to prevent risks and disturbances : flood risk, degradation of groundwater quality, jeopardizing geothermal potential.
4

Estimativa de recarga e caracterização hidroquímica e isotópica das águas subterrâneas dos aquíferos da região do canal do Jurubatuba / Recharge estimate and hydrochemical and isotopic characterization of aquifers groundwaters in the Jurubatuba Canal region

Silva, Jose Angelo Ferreira da 09 February 2018 (has links)
Os aquíferos da região do Canal do Jurubatuba são importantes no abastecimento industrial, comercial e residencial. Em 2001, foi detectada contaminação por solventes organoclorados nos solos e nas águas subterrâneas da região, atingindo o aquífero fraturado profundo, caracterizando risco para a população local e acarretando na paralisação de diversos poços de produção. Tratando-se de um aquífero fraturado, a contaminação apresentou-se complexa, devido a dificuldades na previsão de fluxos nesses sistemas. Este trabalho, inserido no projeto \"Bases técnicas para a gestão de áreas contaminadas por solventes clorados\" (GESOL), objetiva estimar a recarga dos aquíferos na região do Canal do Jurubatuba, por meio dos métodos de balanço hídrico, da variação do nível d\'água do aquífero e isotópico; realizar as caracterizações hidroquímica e isotópica (O, H, e Sr) das águas subterrâneas e das potenciais fontes de recarga (água da chuva rede de abastecimento de água e de esgoto); e integrar os resultados para avaliar a atuação dos processos naturais e das possíveis influências antrópica e da dinâmica das águas subterrâneas na sua composição. Os trabalhos incluíram o monitoramento de dados meteorológicos e da variação do nível d\'água subterrânea; e coleta de amostras de água para análises químicas e isotópicas. O acumulado de chuvas mensal e a respectiva variação do nível d\'água dos poços monitorados, evidenciaram que a recarga dos aquíferos está sendo efetiva sob pluviometria média acima de 100 mm, confirmada pelo monitoramento da zona não saturada. As análises isotópicas da chuva permitiram elaborar a reta meteórica local, que apresentou boa correlação com a reta meteórica global, além de evidenciarem haver relação entre a quantidade de precipitação mensal e a variação no enriquecimento de isótopos estáveis. O enriquecimento isotópico nos resultados das amostras e água e de fontes, observado durante o período prolongado de seca de 2013/2014, apresentou correlação com poços com maior contribuição de fonte antrópica na recarga naquele período, indicando influência de diferentes comportamentos do clima na composição das fontes de recarga e das águas subterrâneas. Os isótopos de Sr apresentaram razoável eficácia na identificação de fontes antrópicas da recarga, mas não permitiram a distinção entre essas fontes. As caracterizações hidroquímica e isotópica mostraram que os aquíferos avaliados apresentaram alteração na qualidade de suas águas, em maior ou menor grau, em diferentes níveis, em decorrência de contribuição de fontes de recarga antrópica. O amônio se mostrou o indicador mais eficaz na determinação de contribuição antrópica na recarga por esgoto, e a presença de nitrato reflete a potencial atuação de processos de nitrificação nas águas subterrâneas. Os resultados dos métodos físicos utilizados para o cálculo de recarga, considerando-se as limitações de cada método, indicaram valores muito próximos. A recarga potencial pelo método do balanço hídrico apresentou média anual de 18,84% e a estimativa de recarga média pelo método da variação do nível d\'água de 16,27% do total de precipitação. O método isotópico indicou média geral de 51,7% de contribuição antrópica na mistura das águas subterrâneas. A influência de fluxos ascendentes, identificada pelas cargas hidráulicas dos poços monitorados e pelas semelhanças hidroquímica e isotópica entre as águas dos poços profundos e rasos, está contribuindo para a mistura das águas subterrâneas dos aquíferos de porosidade intergranular. / The aquifers in the Jurubatuba Canal region are important for the industrial, commercial and residential supply. In 2001, a contamination by organochlorine solvents was detected in the soils and groundwater in the region, reaching the deep fractured aquifer, posing risk for the local population and causing the interruption in several production wells. As the aquifer is fractured, the contamination was found to be complex, due to the difficulty to predict the flows in these systems. This study, part of the project called \"Technical base for the management of areas contaminated by chlorine solventes (1)\", aims at estimating the recharge of the aquifers in the Jurubatuba Canal region using water balance, water table flutuation and isotopic methods; developing the hydrochemical and (O, H and Sr) isotopic studies about the groundwater and the potential recharge sources (rainwater, water and sewage supply networks); and integrating the results in order to assess the action of natural processes and possible anthropic and dynamic influences in the groundwater composition. The studies have included monitoring meteorological data and groundwater level variation; and also collecting water samples for chemical and isotopic analyses. The total monthly rainfall and the correspondent variation of the water levels in the monitored wells have shown that the aquifers recharge has been effective, with an average rainfall above 100 mm, confirmed by the monitoring of the unsaturated zone. The isotopic analyses of the rainfall have enabled the elaboration of the local meteoric water line, which has presented a good correlation with the global meteoric water line, and they have also pointed out a relation between the monthly precipitation quantity and the variation in the enrichment of stable isotopes. The isotopic enrichment in the results of water and recharge sources samples, observed during the long dry period in 2013/2014, has presented a correlation with the wells that have a bigger contribution of anthropic source in the recharge of that period, indicating an influence of climate changes in the composition of the recharge sources and the groundwater. The Sr isotopes have presented a reasonable efficacy in the identification of anthropic recharge sources, but they have not allowed the distinction between these sources. The hydrochemical and isotopic characterizations have shown that the evaluated aquifers have presented a bigger or smaler alteration in their water quality in different levels, due to the contribution of anthropic recharge sources. Ammonium was found to be the most efficient index to determine the anthropic contribution for the sewage recharge and the presence of nitrate reflects the potential action of nitrification processes in the groundwaters. The results of the physical methods used for the recharge calculation, considering the limitations of each method, indicated very close values. The potential recharge by the water balance method has presented an annual average of 18.84% and the average recharge estimate of the water table flutuation was 16.27% of the total precipitation. The isotopic method has shown a general average of 51.7% of anthropic contribution in the groundwater mixing. The influence of upward flows, identified by the hydraulic charges in the monitored wells and by the hydrochemical and isotopic similarities between the waters in the deep and shallow wells, is contributing for the mixing of the groundwaters of the intergranular porosity aquifers.
5

Estimativa de recarga e caracterização hidroquímica e isotópica das águas subterrâneas dos aquíferos da região do canal do Jurubatuba / Recharge estimate and hydrochemical and isotopic characterization of aquifers groundwaters in the Jurubatuba Canal region

Jose Angelo Ferreira da Silva 09 February 2018 (has links)
Os aquíferos da região do Canal do Jurubatuba são importantes no abastecimento industrial, comercial e residencial. Em 2001, foi detectada contaminação por solventes organoclorados nos solos e nas águas subterrâneas da região, atingindo o aquífero fraturado profundo, caracterizando risco para a população local e acarretando na paralisação de diversos poços de produção. Tratando-se de um aquífero fraturado, a contaminação apresentou-se complexa, devido a dificuldades na previsão de fluxos nesses sistemas. Este trabalho, inserido no projeto \"Bases técnicas para a gestão de áreas contaminadas por solventes clorados\" (GESOL), objetiva estimar a recarga dos aquíferos na região do Canal do Jurubatuba, por meio dos métodos de balanço hídrico, da variação do nível d\'água do aquífero e isotópico; realizar as caracterizações hidroquímica e isotópica (O, H, e Sr) das águas subterrâneas e das potenciais fontes de recarga (água da chuva rede de abastecimento de água e de esgoto); e integrar os resultados para avaliar a atuação dos processos naturais e das possíveis influências antrópica e da dinâmica das águas subterrâneas na sua composição. Os trabalhos incluíram o monitoramento de dados meteorológicos e da variação do nível d\'água subterrânea; e coleta de amostras de água para análises químicas e isotópicas. O acumulado de chuvas mensal e a respectiva variação do nível d\'água dos poços monitorados, evidenciaram que a recarga dos aquíferos está sendo efetiva sob pluviometria média acima de 100 mm, confirmada pelo monitoramento da zona não saturada. As análises isotópicas da chuva permitiram elaborar a reta meteórica local, que apresentou boa correlação com a reta meteórica global, além de evidenciarem haver relação entre a quantidade de precipitação mensal e a variação no enriquecimento de isótopos estáveis. O enriquecimento isotópico nos resultados das amostras e água e de fontes, observado durante o período prolongado de seca de 2013/2014, apresentou correlação com poços com maior contribuição de fonte antrópica na recarga naquele período, indicando influência de diferentes comportamentos do clima na composição das fontes de recarga e das águas subterrâneas. Os isótopos de Sr apresentaram razoável eficácia na identificação de fontes antrópicas da recarga, mas não permitiram a distinção entre essas fontes. As caracterizações hidroquímica e isotópica mostraram que os aquíferos avaliados apresentaram alteração na qualidade de suas águas, em maior ou menor grau, em diferentes níveis, em decorrência de contribuição de fontes de recarga antrópica. O amônio se mostrou o indicador mais eficaz na determinação de contribuição antrópica na recarga por esgoto, e a presença de nitrato reflete a potencial atuação de processos de nitrificação nas águas subterrâneas. Os resultados dos métodos físicos utilizados para o cálculo de recarga, considerando-se as limitações de cada método, indicaram valores muito próximos. A recarga potencial pelo método do balanço hídrico apresentou média anual de 18,84% e a estimativa de recarga média pelo método da variação do nível d\'água de 16,27% do total de precipitação. O método isotópico indicou média geral de 51,7% de contribuição antrópica na mistura das águas subterrâneas. A influência de fluxos ascendentes, identificada pelas cargas hidráulicas dos poços monitorados e pelas semelhanças hidroquímica e isotópica entre as águas dos poços profundos e rasos, está contribuindo para a mistura das águas subterrâneas dos aquíferos de porosidade intergranular. / The aquifers in the Jurubatuba Canal region are important for the industrial, commercial and residential supply. In 2001, a contamination by organochlorine solvents was detected in the soils and groundwater in the region, reaching the deep fractured aquifer, posing risk for the local population and causing the interruption in several production wells. As the aquifer is fractured, the contamination was found to be complex, due to the difficulty to predict the flows in these systems. This study, part of the project called \"Technical base for the management of areas contaminated by chlorine solventes (1)\", aims at estimating the recharge of the aquifers in the Jurubatuba Canal region using water balance, water table flutuation and isotopic methods; developing the hydrochemical and (O, H and Sr) isotopic studies about the groundwater and the potential recharge sources (rainwater, water and sewage supply networks); and integrating the results in order to assess the action of natural processes and possible anthropic and dynamic influences in the groundwater composition. The studies have included monitoring meteorological data and groundwater level variation; and also collecting water samples for chemical and isotopic analyses. The total monthly rainfall and the correspondent variation of the water levels in the monitored wells have shown that the aquifers recharge has been effective, with an average rainfall above 100 mm, confirmed by the monitoring of the unsaturated zone. The isotopic analyses of the rainfall have enabled the elaboration of the local meteoric water line, which has presented a good correlation with the global meteoric water line, and they have also pointed out a relation between the monthly precipitation quantity and the variation in the enrichment of stable isotopes. The isotopic enrichment in the results of water and recharge sources samples, observed during the long dry period in 2013/2014, has presented a correlation with the wells that have a bigger contribution of anthropic source in the recharge of that period, indicating an influence of climate changes in the composition of the recharge sources and the groundwater. The Sr isotopes have presented a reasonable efficacy in the identification of anthropic recharge sources, but they have not allowed the distinction between these sources. The hydrochemical and isotopic characterizations have shown that the evaluated aquifers have presented a bigger or smaler alteration in their water quality in different levels, due to the contribution of anthropic recharge sources. Ammonium was found to be the most efficient index to determine the anthropic contribution for the sewage recharge and the presence of nitrate reflects the potential action of nitrification processes in the groundwaters. The results of the physical methods used for the recharge calculation, considering the limitations of each method, indicated very close values. The potential recharge by the water balance method has presented an annual average of 18.84% and the average recharge estimate of the water table flutuation was 16.27% of the total precipitation. The isotopic method has shown a general average of 51.7% of anthropic contribution in the groundwater mixing. The influence of upward flows, identified by the hydraulic charges in the monitored wells and by the hydrochemical and isotopic similarities between the waters in the deep and shallow wells, is contributing for the mixing of the groundwaters of the intergranular porosity aquifers.

Page generated in 0.0523 seconds