Influencia de interferentes en el recuento plaquetario en pacientes hemato-oncológicos mediante el principio de impedancia y recuento óptico/fluorescente en el analizador SYSMEX XE-2100 FULL

Congona Rivera, Roberts Yuri January 2011 (has links)
El estudio fue realizado en el Instituto Nacional de Enfermedades Neoplásicas en el periodo de enero a mayo del año 2011, en el laboratorio de Hematología General. El objetivo de este estudio fue determinar la influencia de interferentes en el recuento de plaquetas obtenidos por el analizador hematológico Sysmex XE 2100, el cual presenta dos metodologías para el recuento de plaquetas: el método de impedancia hidrofocalizada (PLT-I) y el método de citometría de fluorescencia (PLT-O), en muestras de pacientes hemato-oncológicos. El estudio se llevó a cabo mediante una data de información de 232 muestras de personas sanas y 1304 muestras patológicas, se formaron subgrupos de muestras patológicas que tengan un interferente en particular, y realizar el análisis en cada uno de estos sub grupos. Los interferentes en estudio son los fragmentos de hematíes, microcitos (volumen corpuscular medio <82 fL), agregados plaquetarios, parámetros plaquetarios elevados: PLC-R > 30% (porcentaje de plaquetas grandes), VPM >11fL (volumen plaquetario medio), PDW > 14% (amplitud de distribución plaquetaria) Se utilizó la impedancia hidrofocalizada del SYSMEX 2100 XE para ser comparada con el método de citometría de fluorescencia. En consecuencia, se determinó, la media aritmética , la desviación estándar y el coeficiente de variación del error absoluto de los recuentos plaquetarios (diferencia PLT-O – PLT-I), tanto para los grupos normales y patológicos, en diferentes intervalos de plaquetas e interferentes en particular. El análisis de datos consistió en determinar el r de Pearson, para determinar la fuerza de asociación en los diversos grupos establecidos; el análisis de regresión lineal, con la finalidad de estudiar el comportamiento del R² y la pendiente en las diferentes situaciones propuestas (interferentes). Para el caso de interferentes que no fue posible su cuantificación de hizo uso del estadístico chi cuadrado x². Finalmente, se realizó el análisis gráfico de concordancia mediante la prueba de Bland – Altmant. Los resultados muestran que en el intervalo de 150-450 x 10^9 plaquetas/L hay mayor dispersión alrededor de la media en muestras con interferentes que en muestras que no lo presentan (muestras normales). La correlación entre los métodos PLT-O y PLT-I en muestras trombocitopénicas (intervalo de plaquetas: 70 – 150 x 10^9/L) disminuye en presencia de interferentes. Los interferentes que produjeron disminución en la correlación fueron P-LCR >30% y VPM >11fL (R²=0.854). Cuando éstos estuvieron presentes en simultáneo en la muestra, la correlación disminuyó levemente (R² =0.849). Sin embargo, se observó que los fragmentos de hematíes (FRC%) >10 % son los que producen mayor disminución en la correlación (R²=0.814). Los resultados del test de concordancia entre los métodos evaluados se vio afectada por los interferentes evaluados, siendo lo fragmentos de hematíes y agregados plaquetarios los que produjeron mayor discordancia. Se llegó a la conclusión que los recuentos obtenidos por el método de citometría de fluorescencia en muestras trombocitopénicas y provenientes de pacientes con alguna entidad hemato - oncológica están influenciados por los interferentes evaluados.
2

Parâmetros oftálmicos em cães adultos da raça Shih Tzu

Kobashigawa, Karina Kamachi [UNESP] 17 January 2014 (has links) (PDF)
Made available in DSpace on 2014-11-10T11:09:44Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-01-17Bitstream added on 2014-11-10T11:58:32Z : No. of bitstreams: 1 000790841.pdf: 1403465 bytes, checksum: 13018455b5c4c9f88bfd51854fffb6ec (MD5) / Afecções da superfície ocular são frequentes em cães braquicefálicos, pela maior exposição do bulbo do olho e por suas intercorrências. Dentre as raças comumente acometidas, tem-se a Shih Tzu, cujos parâmetros oftálmicos não são conhecidos em sua plenitude e foram, em parte, avaliados nesta pesquisa. Sob contenção física, empregou-se o teste lacrimal de Schirmer, o de ruptura do filme lacrimal, a estesiometria, a biomicroscopia com lâmpada em fenda, a microscopia especular de não contato, a flaremetria a “laser”, a tonometria de aplanação, a ecografia e a oftalmoscopia. Foram estudados 48 olhos em 24 indivíduos machos ou fêmeas, com idades variando entre dois a quatro anos e peso entre cinco a 10 Kg, provenientes de canil de criação. Aos dados aplicou-se a estatística descritiva. Relativamente às médias e aos erros padrão, encontraram-se, quanto ao teste lacrimal de Schirmer, 26,145±0,803 mm/min e à ruptura do filme lacrimal, 13,668±0,538 s. À estesiometria, encontraram-se 2,395±0,071 cm. À biomicroscopia, observaram-se 70,83% dos olhos com entrópio de canto medial, 42% apresentaram pelos em carúncula medial, 33% distiquíase, 27% mácula e 13% melanose corneal. Médias e erros padrão, no que concerne à densidade de células endoteliais, foram de 2221,591±20,161 céls/mm2. Quanto à hexagonalidade, foram de 63,770±1,805 %; quanto à área, foram de 451,895±4,179 mm2; e em relação à espessura corneal, de 0,490±0,007 mm. À flaremetria a “laser”, encontraram-se 1,720±0,216 PC/ms e à tonometria, 16,118±0,460 mmHg. As médias e os erros padrão, à ultrassonografia, foram de 20,255±0,134 mm para diâmetro axial horizontal, de 6,624±0,031 mm para espessura da lente, de 4,064±0,109 mm para profundidade da câmara anterior e de 9,565±0,054 mm para a da vítrea O padrão observado à oftalmoscopia não divergiu do já reportado em indivíduos de ... / Ocular surface diseases are often diagnosed in brachycephalic dogs, since their eyes are more exposed. Among the most commonly affected breeds, Shih Tzu dogs are part listed and this breed’s ophthalmic standards are not totally known. In this study ophthalmic standards of this breed were partly studied under physical restraint. Schirmer tear test, break up time test, aesthesiometry, biomicroscopy, non contact specular microscopy, laser flaremetry, applanation tonometry, ultrasonography and ophthalmoscopy were carried in 48 eyes of 24 male and female dogs, with ages from two to four years, weighing between five and 10 kg. All dogs were from a breeding kennel. Descriptive statistics was applied to the data. Mean and standard error for Schirmer tear test was 26.145±0.803 mm/min, for break up time test was 13.668±0.538 s, for aesthesiometry was 2.395±0.071 cm. When evaluated with biomicroscopy 70.83% of the eyes showed medial entropion, 42% showed caruncle trichiasis, 33% distichiasis, 27% corneal opacity and 13% corneal melanosis. Mean and standard error for endothelial cell density was 2221.591±20.161cells/mm2, for endothelial cell hexagonality was 63.770±1.805 %; for endothelial cell area was 451.895±4.179 mm2; for central corneal thickness was 0.490±0.007 mm, for laser flaremetry was 1.720±0.216 PC/ms, for applanation tonometry was 16.118±0.460 mmHg, for axial lenght was 20.255±0.134 mm, for lens thickness was 6.624±0.031 mm, for anterior chamber was 4.064±0.109 mm and for vitreous chamber was 9.565±0.054 mm. Ophthalmoscopy findings were not different from previous reports in other breeds. According to the results obtained, ophthalmic Shih Tzu standards did not differ from reports in other breeds, except for break up time and Cochet-Bonnet aesthesiometry
3

Parâmetros oftálmicos em diferentes espécies de cervídeos brasileiros mantidos em cativeiro

Crivelaro, Roberta Martins [UNESP] 16 January 2014 (has links) (PDF)
Made available in DSpace on 2014-11-10T11:09:45Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-01-16Bitstream added on 2014-11-10T11:58:32Z : No. of bitstreams: 1 000790850.pdf: 44012970 bytes, checksum: e9db0e5d90e54a75807c00e53994eee2 (MD5) / Cervídeos da fauna brasileira, muitos dos quais sob risco de extinção, não estão livres de afecções oculares. O conhecimento sobre os parâmetros oftálmicos é particularmente importante, notadamente para o diagnóstico e a terapêutica das oftalmopatias que os acometem. Foram avaliadas a produção lacrimal, empregando-se o teste da lágrima de Schirmer; a pressão intraocular, pela tonometria digital de aplanação; a biometria ocular, à ultrassonografia; a biometria craniana, à paquimetria; e as condições da retina, pela eletrorretinografia. Estudaram-se e compararam-se as espécies Mazama americana, Mazama nemorivaga, Mazama gouazoubira, Mazama nana, Mazama bororo, Blastocerus dichotomus, Odocoileus virginianus e Ozotoceros bezoarticus, livres de afecções oftálmicas. Valores de Schirmer mostraram-se menores que os referidos para animais domésticos e selvagens e não diferiram entre as espécies avaliadas. Valores de pressão intraocular não diferiram das de animais de famílias semelhantes já estudadas. Diferenças entre as espécies foram encontradas relativamente à PIO, estando o maior valor com o O. bezoarticus (19 mmHg) e o menor com o M. nemorivaga (5 mmHg). Animais que habitam áreas de vegetação predominantemente densa exibiram córneas mais espessas. Animais que habitam áreas de vegetação predominantemente aberta, exibiram córneas mais delgadas. Relativamente à espessura da lente e ao comprimento axial do olho, espécies com olhos de maior tamanho foram as de áreas de vegetação fechada e espécies com olhos de menor tamanho corresponderam às de vegetação aberta. A eletrorretinografia não apontou diferenças entre as espécies / Brazilian deer, some of which are at risk of extinction, are not free from ophthlamic lesions. Knowledge about ophthalmic parameters is particularly important, especially for diagnostics and therapeutics of ophthalmopaties that can affect them. At this study, tear production, measured with Schirmer tear test, introcular pressure, measured with applanation tonometry, ocular biometry, measured from ultrasonographic images, head biometry, using a caliper rule, and retina conditions, by electroretinography, were evaluated. Several adult captive deer, from eight different species (Mazama americana, Mazama nemorivaga, Mazama gouazoubira, Mazama nana, Mazama bororo, Blastocerus dichotomus, Odocoileus virginianus e Ozotoceros bezoarticus), free from ophthalmic lesions, were studied and compared. Tear production did not differ between studied species and were lower than values in domestic and other wild animals. Intraocular pressure were similar to other animal from resembling families. IOP data showed differences between species, where the highest values were found in O. bezoarticus (19 mmHg), and the lowest in M. nemorivaga (5 mmHg). Corneal thickness was higher in animals living in areas with dense vegetation, while lower values were found in animals who live in areas with open vegetation. The same correlation could me made when looking at lens thickness and axial lenght, where species with bigger eyes live in areas with dense vegetation, while species with smaller eyes live in areas with open vegatation. Electroretinography did not show differences between species