• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influência da forma urbana na ventilação natural: um estudo de caso no cais José Estelita, Recife

Sousa, Joana Pack Melo 19 May 2014 (has links)
Submitted by Luiza Maria Pereira de Oliveira (luiza.oliveira@ufpe.br) on 2015-05-18T16:28:54Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) DISSERTAÇÃO Joana Pack Melo Sousa.pdf: 10076016 bytes, checksum: fbade0cc01219af8e8fa200d323342fe (MD5) / Made available in DSpace on 2015-05-18T16:28:54Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) DISSERTAÇÃO Joana Pack Melo Sousa.pdf: 10076016 bytes, checksum: fbade0cc01219af8e8fa200d323342fe (MD5) Previous issue date: 2014-05-19 / A cidade do Recife passa por um rápido processo de transformação urbana. Ao mesmo tempo em que expande a ocupação para as cidades vizinhas, também adensa o núcleo urbano, por meio da verticalização e do aumento da taxa de ocupação do solo. Esta ação se intensifica em várias áreas da cidade, sem que sejam contemplados estudos técnicos suficientes, que demonstrem as modificações ocorridas no microclima urbano. Entre as diferentes variáveis climáticas, a ventilação natural é a que, mais facilmente, se altera com a urbanização, além de ser a mais importante estratégia de conforto térmico, de salubridade e de economia energética em climas quentes e úmidos, onde se localiza a cidade do Recife. Esta pesquisa tem como objetivo principal analisar as alterações que ocorrem na ventilação natural, com a edificação de diferentes formas de ocupação urbana. Como objeto de estudo empírico, foi selecionada a área do Cais José Estelita, no bairro de São José, por ser um local central, junto à bacia do Pina, com baixa densidade populacional e com grande parte de sua estrutura urbana ociosa. Assim sendo, essa área apresenta um grande potencial de adensamento futuro. Tomou-se, como referência inicial, o projeto Novo Recife proposto para aquele terreno, com o intuito de contribuir no entendimento das modificações que irão ocorrer no deslocamento do ar, caso este modelo de ocupação venha a ser construído. Para além desta análise, foram elaboradas cinco derivações da forma urbana, com variação dos afastamentos, da altura e da porosidade dos edifícios, a fim de compreender se outros modelos de ocupação, com densidade construtiva semelhante, poderiam trazer mais benefícios ao conforto térmico e à ventilação natural da cidade. O trabalho consiste em uma pesquisa experimental, em que seis cenários virtuais foram criados e simulados no programa de dinâmica de fluidos PHOENICS VR 3.6.1, no laboratório de conforto da Universidade Federal de Alagoas. A construção dos cenários foi fundamentada nos conceitos teóricos que pautam as preocupações ambientais de adensamento e forma urbana, nos conhecimentos de conforto térmico e ventilação urbana e nas características especificas do caso de estudo empírico. No final do estudo, o cenário que mais diminui o fluxo de vento é o modelo 3, porque a configuração dos edifícios e da forma urbana origina uma extensa zona de esteira a sotavento. No entanto, o modelo 1 é o que incita mais prejuízos para o conforto do pedestre, porque combina áreas com velocidade do ar demasiado elevada (acima de 6,125m/s) nas ruas laterais, com áreas de fraca taxa de ventilação (inferior a 1,75m/s) a sotavento dos edifícios, criando assim mais espaços contínuos onde os pedestres estão fora da sua zona de conforto. Para concluir, o modelo 4, apresentou muitas vantagens em relação ao modelo 3, demonstrando que a porosidade dos edifícios é fundamental para melhorar a circulação do ar na cidade.
2

Análise da influência de corpos d'água em microclimas urbanos: estudo de caso em São José do Rio Preto, SP

Masiero, Érico 06 June 2014 (has links)
Made available in DSpace on 2016-06-02T19:58:06Z (GMT). No. of bitstreams: 1 6113.pdf: 14480974 bytes, checksum: cca2a2f995c38bc760cbc592a2cee898 (MD5) Previous issue date: 2014-06-06 / Financiadora de Estudos e Projetos / This study analyzes the microclimate effects caused by a water body in São José do Rio Preto city, which is located at an Altitute Tropical Climate region in the São Paulo State, Brazil. The main hypothesis stems from the conjunction among the air masses action in the region combined with the evaporative cooling by the water body in the built environment. The study methodology is based on the physical characterization of different environments that make up the urban environment, in determining procedures of gathering data field, in the analysis of macro and meso climatic characteristics of the region, in the treatment of microclimate data by mapping information and the formulation of guide lines for urban space occupation. The monitoring field data campaigns used meteorological measurements at fixed points to record the behavior of temperature, humidity, solar radiation, evapotranspiration, the wind speed and direction in the urban area, both in the rural environment, in the bank of the dam, in the inner city and in the suburbs. Climate general information of the region were collected by Automatic Weather Station of CIIAGRO Center for Integrated Agricultural Weather Information and the CETESB Station Environmental Company of São Paulo State - which were crossed with the data and the satellite images of INPE-CPTEC Prediction Center of Weather and Climate Research. After the field campaigns, climatic data and physical characteristics of the urban environment were processed using geostatistical methods for mapping the microclimate behavior of the studied urban areas. We concluded that the wind action over the water mass may influence the immediate surroundings, reaching approximately 1.000m depending of the topographical characteristics, of the urban occupation and the atmospheric conditions. Humidification of urban air through the water body can reduce the daily temperature peaks at approximately 3°C, however, the significant difference found in the rates of temperature and humidity in the urban canopy layer clarifies that the 9 km² of the water surface are insufficient to influence the farthest outlying areas of the dam under any climatic conditions. The low penetration of humidified air masses suggests that urban space should favor the passive action of evaporative cooling to cause microclimatic effects to mitigate the temperature amplitude in low vegetated areas and in a highly waterproofed city. / Este estudo analisa os efeitos microclimáticos provocados por corpo d´água sobre a cidade de São José do Rio Preto, localizada em uma região de clima Tropical de Altitude no Estado de São Paulo. A principal hipótese decorre da conjunção entre a atuação das massas de ar da região, com o resfriamento evaporativo provocado pelo corpo d água e com o ambiente construído. A metodologia do estudo se baseia na caracterização física dos diversos ambientes que compõem o espaço urbano, na determinação dos procedimentos de coleta de dados de campo, na análise das características macro e meso climáticas da região, no tratamento de dados microclimáticos através do mapeamento de informações e na formulação de diretrizes para a ocupação do espaço urbano. As campanhas de coleta de dados micrometeorológicos utilizaram medições em pontos fixos para registrar o comportamento da temperatura, da umidade, da irradiância global horizontal, da evaporação, da direção e da velocidade do vento na malha urbana, tanto na área rural como nas margens da represa, no centro urbano e nos bairros periféricos. Os dados climáticos da região foram coletados pela Estação Meteorológica automática do CIIAGRO - Centro Integrado de Informações Agro Meteorológicas e pela estação da CETESB Companhia Ambiental do Estado de São Paulo as quais foram cruzadas com os dados e Imagens de Satélite do Centro de Previsão de Tempo e Estudos Climáticos CPTEC INPE. Após as coletas de campo, os dados climáticos e as informações das características físicas do ambiente urbano foram processados através de métodos geoestatísticos para mapear o comportamento microclimático das áreas urbanas estudadas. Conclui-se que a ação do vento sobre a massa d água pode influenciar no entorno imediato, chegando a influenciar até aproximadamente 1.000m de raio de distância, dependendo das características topográficas, de ocupação e das condições atmosféricas. A umidificação do ar urbano através do corpo d água pode reduzir os picos diários de temperatura em aproximadamente 3°C, no entanto, a expressiva diferença detectada nos índices de temperatura e umidade nas camadas intraurbanas esclarece que os 9 km² da represa municipal são insuficientes para influenciar as zonas periféricas mais distantes dela, sob quaisquer condições climáticas. A pouca penetração das massas umidificadas de ar sugere que o espaço urbano deve favorecer a ação passiva do resfriamento evaporativo para provocar efeitos microclimáticos que amenizem a amplitude térmica nos espaços pouco vegetados e muito impermeabilizados da cidade.

Page generated in 0.0808 seconds