• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 2
  • Tagged with
  • 9
  • 9
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Effects of single-site and multi-site ventricular pacing on left and right ventricular mechanics and synchrony is there an optimal pacing sequence? /

Nishijima, Yoshinori. January 2005 (has links)
Thesis (Ph. D.)--Ohio State University, 2005. / Available online via OhioLINK's ETD Center; full text release delayed at author's request until 2006 September 15.
2

Alterations in myosin and myocyte structure in an extremely long term pacing model of canine dilated cardiomyopathy /

Fuller, Geraldine Anne. January 2002 (has links)
No description available.
3

Mechanism of endotoxin induced cardiac dysfunction role of SR Ca²⁺-ATPase /

Keller, Rebecca S. January 1996 (has links)
Thesis (Ph. D.)--University of Missouri--Columbia, 1996. / Typescript. Vita. Includes bibliographical references (leaves : 188-225). Also available on the Internet.
4

Mechanism of endotoxin induced cardiac dysfunction : role of SR Ca²⁺-ATPase /

Keller, Rebecca S. January 1996 (has links)
Thesis (Ph. D.)--University of Missouri--Columbia, 1996. / "May 1996" Typescript. Vita. Includes bibliographical references (l. 188-225). Also available on the Internet.
5

Avaliação de alterações ocasionadas pela circulação extracorpórea em cães: estudo clínico, laboratorial e anátomo-histopatológico do coração e pulmões / Evaluation of alterations promoted by cardiopulmonary bypass in dogs: clinical, laboratorial and anatomic-histhopathological study of the heart and lungs

Freitas, Rodrigo Ramos de 09 December 2004 (has links)
A circulação extracorpórea (CEC) é atualmente técnica amplamente utilizada na rotina da cirurgia cardíaca humana. Entretanto, na medicina veterinária, ainda não é utilizada rotineiramente devido a alta mortalidade que ocasiona. O presente experimento utilizou cinco cães machos, SRD, em condições satisfatórias para a realização de pesquisa médica. Esses animais foram submetidos a toracotomia intercostal direita convencional e realizadas as mensurações e coletas padrão pertinentes do experimento (M0). Após isso, os animais foram conectados a máquina de circulação extracorpórea, onde permaneceram por um período de duas horas (M1), sendo então desconectados da mesma, permanecendo por uma hora em processo de reperfusão pós CEC (M2) para após sofrer eutanásia. Foram avaliados os seguintes parâmetros: paO2 e pvO2 (oxigenação), paCO2 e pvCO2 (ventilação), pH e HCO3 (equilíbrio ácido-básico), Na, K e Ca ionizado (eletrólitos séricos), freqüência cardíaca, freqüência respiratória, temperatura retal, pressão arterial média, contagem de plaquetas, proteínas totais, glicose sérica, hematócrito, contagem de hemácias, avaliação anátomo-histopatológica do coração e pulmões. Foram observadas alterações significativas na oxigenação, ventilação, equilíbrio ácido-básico, eletrólito sérico potássio, freqüência cardíaca, temperatura retal, contagem de plaquetas, proteínas totais, glicose sérica, hematócrito, contagem de hemácias e no exame histológico do coração e pulmões. Fundamentado nos resultados verificados, concluiu-se que a circulação extracorpórea por duas horas com reperfusão durante 1 hora determina, em cães, alterações clínicas, modificações de parâmetros sanguíneos e induz processos patológicos no coração e pulmões / Actually cardiopulmonary bypass is frequently used in human cardiac surgery routine. However, in veterinary medicine, that does not happened because the high mortality produced. The present study was performed in five males mongrel dogs, in good health conditions for experimental purposes. These animals were submitted to a convencional right intercostal thoracotomy and it was collected the data and materials that concerns to the experiment (M0). Then the animals were connected to the cardiopulmonary bypass machine for a period of two hours (M1), disconnected of the machine and kept alive for a one hour period of reperfusion (M2) before the euthanasia. It was evaluated the paO2 e pvO2 (oxigenation), paCO2 e pvCO2 (ventilation), pH e HCO3 (acid-basic balance), Na, K e ionized Ca (serum electrolites), heart beats, respiratory movements, temperature, mean arterial pressure, platelets number, total protein dosage, serum glucose, hematocrit, red cells number, anatomic-histopathological evaluation of heart and lungs. It was observed significant alterations on the oxigenation, ventilation, acid-basic balance, potassium, heart beats, temperature, platelets number, total protein dosage, serum glucose, hematocrit, red cells number and at the anatomic-histhopathological exam of the heart and lungs. Evaluating the results, it was concluded that the cardiopulmonary bypass in dogs for two hours and a reperfusion period of one hour produced clinical alterations, blood parameters modifications and pathological process in the heart and lungs
6

Atrial and AV-nodal physiology in horses electrophysiologic and echocardiographic characterization and pharmacologic effects of diltiazem /

Schwarzwald, Colin C. January 2006 (has links)
Thesis (Ph. D.)--Ohio State University, 2006. / Available online via OhioLINK's ETD Center; full text release delayed at author's request until 2007 Sep 12
7

Investigation and assessment of ejection murmurs and the left ventricular outflow tract in Boxer dogs

Koplitz, Shianne L. January 2005 (has links)
Thesis (Ph. D.)--Ohio State University, 2005. / Available online via OhioLINK's ETD Center; full text release delayed at author's request until 2006 Aug 15.
8

Avaliação de alterações ocasionadas pela circulação extracorpórea em cães: estudo clínico, laboratorial e anátomo-histopatológico do coração e pulmões / Evaluation of alterations promoted by cardiopulmonary bypass in dogs: clinical, laboratorial and anatomic-histhopathological study of the heart and lungs

Rodrigo Ramos de Freitas 09 December 2004 (has links)
A circulação extracorpórea (CEC) é atualmente técnica amplamente utilizada na rotina da cirurgia cardíaca humana. Entretanto, na medicina veterinária, ainda não é utilizada rotineiramente devido a alta mortalidade que ocasiona. O presente experimento utilizou cinco cães machos, SRD, em condições satisfatórias para a realização de pesquisa médica. Esses animais foram submetidos a toracotomia intercostal direita convencional e realizadas as mensurações e coletas padrão pertinentes do experimento (M0). Após isso, os animais foram conectados a máquina de circulação extracorpórea, onde permaneceram por um período de duas horas (M1), sendo então desconectados da mesma, permanecendo por uma hora em processo de reperfusão pós CEC (M2) para após sofrer eutanásia. Foram avaliados os seguintes parâmetros: paO2 e pvO2 (oxigenação), paCO2 e pvCO2 (ventilação), pH e HCO3 (equilíbrio ácido-básico), Na, K e Ca ionizado (eletrólitos séricos), freqüência cardíaca, freqüência respiratória, temperatura retal, pressão arterial média, contagem de plaquetas, proteínas totais, glicose sérica, hematócrito, contagem de hemácias, avaliação anátomo-histopatológica do coração e pulmões. Foram observadas alterações significativas na oxigenação, ventilação, equilíbrio ácido-básico, eletrólito sérico potássio, freqüência cardíaca, temperatura retal, contagem de plaquetas, proteínas totais, glicose sérica, hematócrito, contagem de hemácias e no exame histológico do coração e pulmões. Fundamentado nos resultados verificados, concluiu-se que a circulação extracorpórea por duas horas com reperfusão durante 1 hora determina, em cães, alterações clínicas, modificações de parâmetros sanguíneos e induz processos patológicos no coração e pulmões / Actually cardiopulmonary bypass is frequently used in human cardiac surgery routine. However, in veterinary medicine, that does not happened because the high mortality produced. The present study was performed in five males mongrel dogs, in good health conditions for experimental purposes. These animals were submitted to a convencional right intercostal thoracotomy and it was collected the data and materials that concerns to the experiment (M0). Then the animals were connected to the cardiopulmonary bypass machine for a period of two hours (M1), disconnected of the machine and kept alive for a one hour period of reperfusion (M2) before the euthanasia. It was evaluated the paO2 e pvO2 (oxigenation), paCO2 e pvCO2 (ventilation), pH e HCO3 (acid-basic balance), Na, K e ionized Ca (serum electrolites), heart beats, respiratory movements, temperature, mean arterial pressure, platelets number, total protein dosage, serum glucose, hematocrit, red cells number, anatomic-histopathological evaluation of heart and lungs. It was observed significant alterations on the oxigenation, ventilation, acid-basic balance, potassium, heart beats, temperature, platelets number, total protein dosage, serum glucose, hematocrit, red cells number and at the anatomic-histhopathological exam of the heart and lungs. Evaluating the results, it was concluded that the cardiopulmonary bypass in dogs for two hours and a reperfusion period of one hour produced clinical alterations, blood parameters modifications and pathological process in the heart and lungs
9

Investigaton and assessment of ejection murmurs and the left ventricular outflow tract in Boxer dogs

Koplitz, Shianne L., DVM 24 August 2005 (has links)
No description available.

Page generated in 0.0811 seconds