• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Comportamento de vigas protendidas pré-moldadas com ligações semi-rígidas.

Catoia, Bruna 28 February 2007 (has links)
Made available in DSpace on 2016-06-02T20:09:05Z (GMT). No. of bitstreams: 1 DissBC.pdf: 11069989 bytes, checksum: b3c92f78ccad794ee5c2bb5f907f4814 (MD5) Previous issue date: 2007-02-28 / Universidade Federal de Minas Gerais / The behaviour of prestressed precast beams is directly affected by the rotational stiffness of the end connections. Although the prestressed beam presents a linear behaviour in service, the effective behaviour of the precast beam depends on the interaction of the beam with the behaviour of its connections. The majority of the experimental investigations on semi-rigid connections in precast concrete structures are focused on the testing of isolated models of connections aiming to the characterization of their moment-rotation relationships. However, the effective behaviour of precast beams with semi-rigid connections can only be determined through tests of precast subframes, wherein the interaction of the beam with its connections can be evaluated. The present research presents a development of an experimental procedure for testing of precast subframes with semi-rigid connections, which integrates analytical equations, allowing estimate the partial restrained moment at the beam-column connections. Using this approach, this research presents the results of an experimental investigation. With the experimental inquiry of the prestressed beam behavior together with the beam-column connections of extremity, through physical tests, was possible esteem the partial restrained in the beam-column connections, despite in exploratory character. Were testing two models, being one compose for a prestressed beam with semi-rigid connections, and the other compose for a simply supported prestressed beam With the analyses of the experimental results for the studied models, the effective restrained of the connections, in other words, the capacity of restriction to the rotation of beam-column connections of extremity in the U.L.S, was esteem as being a value between 60% and 70%, presenting, thus, a good performance. Although these results are restricted to the negative moments, it gives credit that these connections possess one high potential for application in porches, because the detail used in the interface between the beam and the column made possible a bigger capacity of restriction to the rotation of the connection / O comportamento das vigas pré-moldadas de concreto protendido é diretamente afetado pela relação momento-rotação do apoio. Dessa forma, embora a viga protendida apresente um comportamento linear, o comportamento conjunto viga e ligações, é determinado pela não linearidade das ligações. Os estudos experimentais existentes sobre o comportamento das ligações semi-rígidas em estruturas pré-moldadas têm se restringido a caracterização da rigidez à flexão de maneira isolada, devido principalmente à falta de uma metodologia experimental que integre parâmetros teóricos de controle, como o fator de restrição à rotação αR e o procedimento Beam-line. Na presente pesquisa, desenvolveu-se um procedimento experimental, através do qual foi possível integrar diversos equacionamentos teóricos, que levam em consideração diferentes parâmetros para a análise dos resultados. Com a investigação experimental do comportamento conjunto de uma viga pré-moldada de concreto protendido e de suas ligações viga-pilar de extremidade, a partir de ensaios físicos de dois modelos, foi possível estimar o engastamento parcial nas ligações viga-pilar. Foram ensaiados dois modelos, sendo um composto por uma viga protendida com ligações semirígidas, e o outro composto por uma viga protendida bi-apoiada, ainda que em caráter exploratório Com base nas análises dos resultados experimentais obtidos para os modelos estudados, o engastamento parcial efetivo da ligação, ou seja, a capacidade de restrição à rotação da ligação viga-pilar de extremidade, no Estado Limite Último, foi estimada como sendo um valor entre 60% e 70%, apresentando, assim, um bom desempenho. Embora tais resultados sejam restritos aos momentos negativos, acredita-se que essa ligação possui um elevado potencial para aplicação em pórticos, na medida em que o detalhe utilizado na interface entre a viga e o pilar possibilitou uma maior capacidade de restrição ao giro da ligação

Page generated in 0.3068 seconds