• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 5
  • 5
  • 5
  • 5
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Ανάλυση συστήματος μεταφοράς με διασύνδεση Σ.Ρ. και PWM ρυθμιζόμενους μετατροπείς

Σακκάς, Σωτήρης 08 January 2013 (has links)
Τα τελευταία χρόνια έχει αρχίσει να διαδίδεται με γρήγορους ρυθμούς η μέθοδος μεταφοράς ισχύος μέσω συνεχούς ρεύματος. Προς αυτή την κατεύθυνση ώθηση έδωσε η ανάπτυξη νέων ημιαγωγικών διακοπτικών στοιχείων οδηγώντας σε περεταίρω ανάπτυξη και χρήση των συστημάτων μεταφοράς με συνεχές ρεύμα. Σε αυτή τη διπλωματική εργασία μελετάται ένα σύστημα μεταφοράς ισχύος με διασύνδεση συνεχούς ρεύματος (HVDC), που συνδέεται ανάμεσα σε δυο εναλλασσόμενα ηλεκτρικά δίκτυα με και χωρίς φορτίο. Την διασύνδεση συνεχούς ρέματος πραγματοποιούν δυο back-to-back AC/DC μετατροπείς VSC, που αναλαμβάνουν τους ρόλους του ανορθωτή και του αντίστροφα ισχύος. Οι μετατροπείς χρησιμοποιούν την διαμόρφωση πλάτους παλμού PWM. Αρχικά μελετάται θεωρητικά το μοντέλο των μετατροπέων και του back-to-back HVDC συστήματος και στην συνέχεια σχεδιάζεται και αναλύεται η λειτουργία του ανάμεσα σε δυο δίκτυα εναλλασσομένου ρεύματος με ή χωρίς την ταυτόχρονη παρουσία φορτίου. Τέλος προσομοιώνεται το σύστημα μέσω του λογισμικού Matlab και συγκεκριμένα της εφαρμογής Simulink για την εξαγωγή συμπερασμάτων. / In the past few years the method of power transmission by means of direct current has expanded rapidly. To this direction a push forward has been given by the development of new semi-conductive switching valves leading to a further development of transmission systems by direct current. In this thesis what is considered is a power transmission system via direct current HVDC connected between two AC electric networks with or without load. The direct current connection is achieved through back-to-back AC/DC converters VSC which undertake the role of rectifier and that of inverter of power. The converters use the Pulse Width Modulation (PWM). At first the converter model and the back-to-back HVDC system is theoretically approached and in the process what is designed and analyzed is its function between two networks of AC current with or without the simultaneous presence of load. Finally the system is simulated through software Matlab and specifically the application of simulink in order to draw conclusions.
2

Investigation of the application of UPFC controllers for weak bus systems subjected to fault conditions : an investigation of the behaviour of a UPFC controller : the voltage stability and power transfer capability of the network and the effect of the position of unsymmetrical fault conditions

Jalboub, Mohamed January 2012 (has links)
In order to identify the weakest bus in a power system so that the Unified Power Flow Controller could be connected, an investigation of static and dynamic voltage stability is presented. Two stability indices, static and dynamic, have been proposed in the thesis. Multi-Input Multi-Output (MIMO) analysis has been used for the dynamic stability analysis. Results based on the Western System Coordinate Council (WSCC) 3-machine, 9-bus test system and IEEE 14 bus Reliability Test System (RTS) shows that these indices detect with the degree of accuracy the weakest bus, the weakest line and the voltage stability margin in the test system before suffering from voltage collapse. Recently, Flexible Alternating Current Transmission systems (FACTs) have become significant due to the need to strengthen existing power systems. The UPFC has been identified in literature as the most comprehensive and complex FACTs equipment that has emerged for the control and optimization of power flow in AC transmission systems. Significant research has been done on the UPFC. However, the extent of UPFC capability, connected to the weakest bus in maintaining the power flows under fault conditions, not only in the line where it is installed, but also in adjacent parallel lines, remains to be studied. In the literature, it has normally been assumed the UPFC is disconnected during a fault period. In this investigation it has been shown that fault conditions can affect the UPFC significantly, even if it occurred on far buses of the power system. This forms the main contribution presented in this thesis. The impact of UPFC in minimizing the disturbances in voltages, currents and power flows under fault conditions are investigated. The WSCC 3-machine, 9-bus test system is used to investigate the effect of an unsymmetrical fault type and position on the operation of UPFC controller in accordance to the G59 protection, stability and regulation. Results show that it is necessary to disconnect the UPFC controller from the power system during unsymmetrical fault conditions.
3

Έλεγχος και ανάλυση μετατροπέα πηγής τάσης από τη [sic] πλευρά του δικτύου για σύνδεση με ανεμογεννήτρια

Μπρίτσας, Παναγιώτης 09 October 2014 (has links)
Στην παρούσα διπλωματική εργασία γίνεται αναφορά στο ενεργειακό πρόβλημα, στις διάφορες μορφές ενέργειας, στα διάφορα είδη μετατροπέων και τα είδη ελέγχου. Πιο συγκεκριμένα, ασχολούμαστε με τον έλεγχο σε μετατροπείς από την πλευρά του δικτύου που χρησιμοποιούνται σε ανεμογεννήτριες. Επιπλέον, εξομοιώνουμε έναν μετατροπέα στη πλευρά του δικτύου για να ρυθμίσουμε τη DC τάση. Πιο συγκεκριμένα: Στο κεφάλαιο 1, θα ασχοληθούμε με το πρόβλημα ενέργειας και την αλλαγή στο κλίμα, τα οποία αποτελούν δύο από τα πιο βασικά προβλήματα του πλανήτη. Ακόμα, θα αναφερθούμε στις Ανανεώσιμες Πηγές Ενέργειας και κυρίως στην αιολική. Επίσης, θα γίνει μία μικρή αναφορά με βάση διαγράμματα για τους κανονισμούς που ισχύουν σε διάφορες χώρες της Ευρώπης όσον αφορά την λειτουργία Εγκαταστάσεων Αιολικής Ενέργειας. Στο κεφάλαιο 2, θα αναφερθούμε στις δομές μετατροπέων για διασύνδεση με ανεμογεννήτριες, καθώς επίσης και στον έλεγχο από την πλευρά της γεννήτριας. Τέλος, γίνεται μία μικρή αναφορά στον έλεγχο ισχύος. Στο κεφάλαιο 3, γίνεται αναφορά στον μετατροπέα πηγής- τάσηςVSC, στα φίλτρα δικτύου και στη διαμόρφωση. Στο κεφάλαιο 4, γίνεται αναφορά στον τριφασικό διπλό μετατροπέα τάσης, στη λειτουργία του, στο μοντέλο του καθώς και στις κατάλληλες εξισώσεις που χρησιμοποιούνται για τον έλεγχο του μετατροπέα. Στο κεφάλαιο 5, γίνεται περιγραφή του ελέγχου με διπλούς βρόγχους, γίνεται μία σύντομη αναφορά στο PLL και δίνονται οι κατάλληλες εξισώσεις. Επιπλέον, γίνεται μια σύντομη περιγραφή του μοντέλου που χρησιμοποιείται στη συγκεκριμένη διπλωματική. Στο κεφάλαιο 6, παρουσιάζουμε την εφαρμογή στο παρών μοντέλο καθώς και τα αποτελέσματα χρησιμοποιώντας το πρόγραμμα matlab/simulink, τις παραμέτρους καθώς επίσης και τις γραφικές παραστάσεις. / --
4

Investigation of the application of UPFC controllers for weak bus systems subjected to fault conditions. An investigation of the behaviour of a UPFC controller: the voltage stability and power transfer capability of the network and the effect of the position of unsymmetrical fault conditions.

Jalboub, Mohamed K. January 2012 (has links)
In order to identify the weakest bus in a power system so that the Unified Power Flow Controller could be connected, an investigation of static and dynamic voltage stability is presented. Two stability indices, static and dynamic, have been proposed in the thesis. Multi-Input Multi-Output (MIMO) analysis has been used for the dynamic stability analysis. Results based on the Western System Coordinate Council (WSCC) 3-machine, 9-bus test system and IEEE 14 bus Reliability Test System (RTS) shows that these indices detect with the degree of accuracy the weakest bus, the weakest line and the voltage stability margin in the test system before suffering from voltage collapse. Recently, Flexible Alternating Current Transmission systems (FACTs) have become significant due to the need to strengthen existing power systems. The UPFC has been identified in literature as the most comprehensive and complex FACTs equipment that has emerged for the control and optimization of power flow in AC transmission systems. Significant research has been done on the UPFC. However, the extent of UPFC capability, connected to the weakest bus in maintaining the power flows under fault conditions, not only in the line where it is installed, but also in adjacent parallel lines, remains to be studied. In the literature, it has normally been assumed the UPFC is disconnected during a fault period. In this investigation it has been shown that fault conditions can affect the UPFC significantly, even if it occurred on far buses of the power system. This forms the main contribution presented in this thesis. The impact of UPFC in minimizing the disturbances in voltages, currents and power flows under fault conditions are investigated. The WSCC 3-machine, 9-bus test system is used to investigate the effect of an unsymmetrical fault type and position on the operation of UPFC controller in accordance to the G59 protection, stability and regulation. Results show that it is necessary to disconnect the UPFC controller from the power system during unsymmetrical fault conditions. / Libyan Government
5

Εφαρμογή τεχνικών υπολογιστικής νοημοσύνης για την αδιάλειπτη λειτουργία συστημάτων ηλεκτρικής ενέργειας με ανεμογεννήτριες σε διαταραχές βραχυκυκλωμάτων / Implementation of intelligent control in the fault ride through of grid connected wind generator

Βρυώνης, Θεόδωρος 16 May 2014 (has links)
Στα πλαίσια της διδακτορικής διατριβής μελετήθηκε η αποτελεσματικότητα διαφόρων κυκλωμάτων ελέγχου που βασίζονται στην υπολογιστική νοημοσύνη με σκοπό την αντιμετώπιση βραχυκυκλωμάτων σε δίκτυα διασύνδεσης ανεμογεννητριών με το δίκτυο. Πιο συγκεκριμένα, τα προτεινόμενα συστήματα ελέγχου έχουν σκοπό τη διαμόρφωση κατάλληλων συνθηκών ώστε οι ανεμογεννήτριες να καταφέρουν να συνεχίσουν να είναι συνδεδεμένες στο δίκτυο κατά τη διάρκεια και αμέσως μετά τα βραχυκυκλώματα, συνεισφέροντας στη γρήγορη επαναφορά της τάσης στο Σημείο Κοινής Σύνδεσης με το Δίκτυο (ΣΚΣΔ). Στο πρώτο μέρος της διατριβής μελετήθηκε ένα προσαρμοζόμενο ασαφές σύστημα ελέγχου με σκοπό τη βελτιωμένη απόκριση Αιολικού Πάρκου (ΑΠ) με επαγωγικές γεννήτριες που τροφοδοτεί ένα ασθενές σύστημα ηλεκτρικής ενέργειας μέσω διασύνδεσης ΕΡ/ΣΡ/ΕΡ με Μετατροπείς Πηγής Τάσης (ΜΠΤ). Το σύστημα αυτό εντοπίζει τη σοβαρότητα του σφάλματος και διαμορφώνει ανάλογα την παλμοδότηση των βαλβίδων των ΜΠΤ κατά τη διάρκεια του σφάλματος. Επίσης, έχει την ιδιότητα να αυτορυθμίζεται κατά τη διάρκεια της μετασφαλματικής περιόδου, επιτυγχάνοντας εξασθένηση της ταλαντωτικής συμπεριφοράς του συστήματος που προκαλείται από τα βραχυκύκλωμα και την παραμονή των ανεμογεννητριών στο δίκτυο. Το ηλεκτρικό σύστημα που μελετήθηκε στο δεύτερο μέρος της διδακτορικής διατριβής περιλαμβάνει μια επαγωγική ανεμογεννήτρια διπλής τροφοδότησης (γνωστή με την ονομασία double-fed induction machine) η οποία τροφοδοτεί ένα δίκτυο ηλεκτρικής ενέργειας. Στη βιβλιογραφία που έχει δημοσιευθεί μέχρι σήμερα, για την αντιμετώπιση των βραχυκυκλωμάτων σε ανάλογα ηλεκτρικά συστήματα, προτείνονται διατάξεις οι οποίες βασίζονται είτε σε κατάλληλο μηχανικό εξοπλισμό όπως μπάρες βραχυκύκλωσης (crowbars) είτε σε κατάλληλο προγραμματισμό των ελεγκτών. Σε αυτό το μέρος της διατριβής προτείνεται ένα εναλλακτικό σύστημα ελέγχου που βασίζεται στον κατάλληλο προγραμματισμό των ελεγκτών, χωρίς να χρησιμοποιεί κάποιον εξοπλισμό προστασίας. Το σύστημα ελέγχου, το οποίο βασίζεται στους γενετικούς αλγορίθμους, συμβάλει στη βέλτιστη «συνεργασία» των δύο ΜΠΤ της γεννήτριας, επιτυγχάνοντας την εξασθένιση των διακυμάνσεων της τάσης στο ΣΚΣΔ και τη διατήρηση της σύνδεσης της γεννήτριας στο ηλεκτρικό δίκτυο. / This thesis studies the implementation of intelligent control techniques in the Fault Ride-Through (FRT) of grid connected Wind Turbines (WTs). The first part of the dissertation studies the issue of the fault ride-through capability of a wind farm of induction generators, which is connected to an ac grid through an HVDC link based on Voltage Sourced Converters (VSCs). This work proposes a control strategy which is implemented with adaptive fuzzy controllers and deals with every different type of fault with a corresponding appropriate action, blocking the converter valves for a time interval which depends on the severity of the fault. In addition, after the deblocking of the valves, the proposed control system activates a special controller, which alleviates the oscillations at the electrical system caused by the blocking of the valves. In this way, the overcurrents are limited, the wind turbines manage to remain connected and the ac voltage recovers quickly, as it is imposed by national grid codes. The second part of the dissertation proposes a Computational Intelligence–based control strategy, to enhance the low voltage ride-through capability of grid-connected WTs with doubly fed induction generators (DFIGs). The conventional crowbar-based systems that were initially applied in order to protect the rotor-side converter at the occurrence of grid faults, do not fulfill the recent requirement of the national GCs that the WTs should supply reactive power to the grid during and after the fault, in order to support the grid voltage. In order to conform to the above mentioned requirement, this work proposes a control scheme, which contributes to the optimal coordination of the two converters, aiming to attenuate the disturbances to the system caused by the fault and ensure system stability. Aiming to encounter the difficulties met due to the uncertainties of the system modeling and considering the non linearity of the system, the controllers were designed based on fuzzy logic and genetic algorithms, which are more efficient in such cases. By this concept the overcurrents at the rotor windings and the dc side overvoltages are effectively eliminated. In addition, the FRT requirement concerning the reactive power supply is fulfilled.

Page generated in 0.1023 seconds