• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 1
  • Tagged with
  • 12
  • 12
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Comparación de la vulnerabilidad sísmica de edificios de concreto armado de 35 pisos con núcleo rígido, con amortiguadores de fluido viscoso y disipadores SLB, mediante el análisis modal pushover en la ciudad de Lima / Comparison of the seismic vulnerability of 35-story reinforced concrete buildings with a rigid core, with viscous fluid dampers and SLB dissipators, using pushover modal analysis in Lima city

Arita Claros, Luis Humberto, Lezameta Navarro, Rodrigo André 15 January 2021 (has links)
Actualmente en la ciudad de Lima existe un número limitado de edificios de gran altura. Por lo que no existe mucha literatura de este tipo de edificaciones en Perú. Los códigos peruanos se enfocan en edificios de mediana y baja altura. Por ello, se requiere realizar estudios más detallados para analizar y diseñar de forma más adecuada estas edificaciones altas según la realidad del país. En el presente artículo, se desarrollará el análisis modal pushover a 6 tipos de edificaciones de concreto armado de 35 niveles en la ciudad de Lima. Se plantea 3 modelos de edificación con distinto sistema estructural y con diferentes plantas (cuadrada y rectangular), siendo las áreas de 29m x 29m y 52m x 26m respectivamente. Estos sistemas estructurales son de núcleo rígido y pórticos con sistema de disipación de energía (amortiguadores de fluido viscoso y disipadores SLB) con objetivo de estudiar su comportamiento frente a solicitaciones sísmicas. Estas edificaciones se establecieron en función de los criterios y requerimientos de los códigos vigentes en el país, como también, distribución de la planta de edificaciones comúnmente usadas para oficinas y viviendas. Se encontró que los periodos naturales oscilan entre 2.6 a 3.3 segundos para edificios de núcleo rígido, se presenta un incremento para los edificios de amortiguamiento viscoso de 4.2 a 5.4 segundos y también para los de dispositivos SLB oscilan en un rango de 3.7 a 4.6 segundos. Se realizó, a su vez, un análisis no lineal estático modal para obtener las curvas de capacidad para cada tipo de edificación, las cuales fueron comparadas con las demandas sísmicas según las provisiones de diseño de la norma peruana sísmica E.030 y un promedio de espectros de registros de aceleraciones de eventos sísmicos severos en Perú y escalados en un rango de 0.2T a 1.5T. Finalmente, se determinó los puntos de desempeño para cada caso de edificación siguiendo las metodologías del ATC-40 encontrando que los edificios altos con núcleo rígido presentan aproximadamente el doble de rigidez que los edificios con sistema de disipación de energía, como también, presentan poca ductilidad a diferencia con los edificios con disipadores que presentan una larga ductilidad. / Currently in Lima city there is a limited number of high-rise buildings. So, there isn’t much literature on this type of building in Peru. Peruvian codes focus on medium and low-rise buildings. Therefore, more detailed studies are required to analyze and design these tall buildings more appropriately according to the reality of the country. In this thesis, the modal pushover analysis of 6 types of 35-story reinforced concrete buildings in Lima city will be developed. Three building models with different structural system and with different plan (square and rectangular) are proposed, being their areas of 29m x 29m and 52m x 26m respectively. These structural systems are rigid core and frames with an energy dissipation system (viscous fluid dampers and SLB dissipators) in order to study their behavior against seismic stresses. These buildings were established based on the criteria and requirements of the current codes in the country, as well as, the distribution of the floors of buildings commonly used for offices and homes. Natural periods were found to range from 2.6 to 3.3 seconds for rigid core buildings, there is an increase for viscous damping buildings from 4.2 to 5.4 seconds and also for SLB devices to range from 3.7 to 4.6 seconds. In turn, a modal static nonlinear analysis was performed to obtain the capacity curves for each type of building, which were compared with the seismic demands according to the design provisions of the Peruvian seismic code E.030 and an average of spectra of acceleration records of severe seismic events in Peru and scaled in a range of 0.2T to 1.5T. Finally, the performance points for each building case were determined following the ATC-40 methodologies, finding that tall buildings with a rigid core have approximately twice the stiffness of buildings with an energy dissipation system, as well as having low ductility. unlike buildings with dissipators that have long ductility. / Tesis
12

Análisis de riesgo sísmico de colegios públicos de San Juan de Miraflores mediante la metodología de Rapid Visual Screening y evaluación del desempeño sísmico con análisis no-lineales del pabellón 780 Pre

Cardenas Angeles, Omar Percy, Farfán Bonett, Aaron Gabriel 16 January 2021 (has links)
Perú se localiza en una zona de alta sismicidad, debido a que se encuentra encima del área de subducción entre la placa tectónica de Nazca y Sudamericana, perteneciente al cinturón de fuego del Pacífico. Perú es un país en vía de desarrollo, por lo que es de suma importancia estar preparados para auxiliar a los miles de damnificados que pueda haber ante un evento sísmico importante. La evaluación del riesgo sísmico de edificaciones esenciales como colegios y hospitales es necesario para trabajos de reforzamiento estructural en este tipo de infraestructura. En el presente artículo científico, se presenta cuán vulnerables son los colegios públicos del distrito de San Juan de Miraflores en la ciudad de Lima ante un evento sísmico. Para ello, se utilizó la metodología de Inspección Visual Rápida del FEMA P-154. Además, se analizó de forma cuantitativa el pabellón 780 Pre, un módulo educativo estandarizado y construido en los años noventa cuya presencia es frecuente en dicho distrito. Para ello, se realizó un análisis no-lineal estático y no-lineal dinámico. Los resultados de la investigación concluyen que la mayoría de las edificaciones educativas presentan una alta vulnerabilidad sísmica y no cumplen con los requerimientos de uso post-sismo como se exige en la norma sismorresistente; así como también se verificó la deficiencia del módulo 780 Pre frente a un sismo severo cuando este fue sometido a los análisis no-lineales. / Peru is located in a high seismicity zone because it is set above the subduction area between the Nazca and South American tectonic plates, both belonging to the Pacific’s Ring of Fire. Being a developing country, it is of utmost importance to be prepared to help the thousands of victims that may be in the face of a major seismic event. The assessment of the seismic vulnerability of essential buildings —such as schools and hospitals— is necessary for structural reinforcement procedures in this type of infrastructure if needed. In this thesis, it is presented how vulnerable are the public schools of the district of San Juan de Miraflores in the city of Lima to a seismic event. For this, the FEMA P-154 Rapid Visual Screening methodology was used. In addition, the “780 Pre” public school building, a standardized educational building built in the 1990s and whose presence is frequent in that district, was analyzed quantitatively. For this, a static nonlinear and dynamic nonlinear analysis were performed. The results of the investigation show that most of the educational buildings present high seismic vulnerability and do not meet the requirements of post-earthquake use as required by the Peruvian seismic design provisions. Also, the deficiency of the 780 Pre building against a severe earthquake when it was subjected to non-linear analyzes was verified. / Tesis

Page generated in 0.0956 seconds