A numerical investigation of air-cooled steam condenser performance under windy conditionsOwen, Michael Trevor Foxwell 03 1900 (has links)
Thesis (MScEng (Mechanical and Mechatronic Engineering))--University of Stellenbosch, 2010. / ENGLISH ABSTRACT: This study is aimed at the development of an efficient and reliable method of evaluating the
performance of an air-cooled steam condenser (ACSC) under windy conditions, using
computational fluid dynamics (CFD). A two-step modelling approach is employed as a result
of computational limitations. The numerical ACSC model developed in this study makes use
of the pressure jump fan model, amongst other approximations, in an attempt to minimize the
computational expense of the performance evaluation. The accuracy of the numerical model
is verified through a comparison of the numerical results to test data collected during full
scale tests carried out on an operational ACSC. Good correlation is achieved between the
numerical results and test data. Further verification is carried out through a comparison to
previous numerical work. Satisfactory convergence is achieved for the most part and the few
discrepancies in the results are explained. The effect of wind on ACSC performance at El
Dorado Power Plant (Nevada, USA) is investigated and it is found that reduced fan
performance due to distorted flow at the inlet of the upstream fans is the primary contributor
to the reduction in performance associated with increased wind speed in this case. An attempt
is subsequently made to identify effective wind effect mitigation measures. To this end the
effects of wind screens, solid walkways and increasing the fan power are investigated. It is
found that the installation of an appropriate wind screen configuration provides a useful
means of reducing the negative effects of wind on ACSC performance and an improved wind
screen configuration is suggested for El Dorado. Solid walkways are also shown to be
beneficial to ACSC performance under windy conditions. It is further found that ACSC
performance increases with walkway width but that the installation of excessively wide
walkways is not justifiable. Finally, increasing the fan power during periods of unfavourable
ambient conditions is shown to have limited benefit in this case. The model developed in this
study has the potential to allow for the evaluation of large ACSC installations and provides a
reliable platform from which further investigations into improving ACSC performance under
windy conditions can be carried out. / AFRIKAANSE OPSOMMING: Hierdie studie is daarop gemik om die ontwikkeling van 'n geskikte en betroubare metode
van evaluering van die verrigting van ’n lugverkoelde stoom-kondensator (air-cooled steam
condenser, ACSC) onder winderige toestande, met behulp van numeriese vloei-dinamika. ’n
Twee-stap modelleringsbenadering is aangewend as gevolg van rekenaar beperkings. Die
numeriese ACSC-model wat in hierdie studie ontwikkel is, maak gebruik van die druksprong
waaier model, asook ander benaderings, in ’n poging om die berekeningskoste van die
verrigting-evaluering te verminder. Die akkuraatheid van die numeriese model is bevestig
deur middel van ’n vergelyking van die numeriese resultate met toetsdata ingesamel tydens
die volskaal toetse uitgevoer op ’n operasionele ACSC. Goeie korrelasie is bereik tussen die
numeriese resultate en toetsdata. Verdere bevestiging is uitgevoer deur middel van ’n
vergelyking met vorige numeriese werk. Bevredigende konvergensie is in die algemeen
bereik en die paar verskille in die resultate word verduidelik. Die effek van wind op ACSC
verrigting by El Dorado Power Plant (Nevada, VSA) is ondersoek, en daar is bevind dat
verlaagde waaierverrigting, as gevolg van vervormde vloei by die inlaat van die stroomop
waaiers, die primêre bydraer is tot die afname in ACSC werkverrigting geassosieer met
verhoogde windsnelheid in hierdie geval. ’n Poging word dan aangewend om effektiewe
wind-effek velagingsmaatreëls te identifiseer. Windskerms, soliede wandelvlakke en die
verhoging van die waaierkrag word gevolglik ondersoek. Daar is bevind dat die installasie
van ’n toepaslike windskerm-opset ’n nuttige middel tot ’n vermindering van die negatiewe
effekte van wind op ACSC verrigting bied, en ’n verbeterde windskerm opset is voorgestel
vir El Dorado. Soliede wandelvlakke word ook aanbeveel as voordelig vir ACSC verrigting
onder winderige toestande. Dit is verder bevind dat die ACSC prestasie verhoog met
wandelvlak breedte, maar dat die installasie van ’n te ruim wandelvlak nie regverdigbaar is
nie. Ten slotte, word bewys dat die verhoging van die waaierkrag tydens periodes van
ongunstige omgewingsomstandighede ’n beperkte voordeel in hierdie geval het. Die model
wat ontwikkel is in hierdie studie het die potensiaal om voorsiening te maak vir die
evaluering van groot ACSC- installasies en bied ’n betroubare platform vanwaar verdere
ondersoeke tot die verbetering van ACSC verrigting onder winderige toestande uitgevoer kan
word.
|
2 |
Estudo da ventilação natural por efeito do vento em pavilhões industriais utilizando modelos reduzidos / The use of reduced models in the study of wind induced natural ventilation in industrial buildingsNunes, Daniel Alexandre January 2006 (has links)
A ventilação natural pode ser promovida por dois mecanismos: o denominado efeito chaminé e o efeito dos ventos, porém também podem ocorrer os dois mecanismos simultaneamente. A determinação das vazões de ventilação por efeito do vento, em pavilhões industriais, pode ser realizada a partir de ensaios de modelos reduzidos em túnel de vento, com medição das velocidades do escoamento nas aberturas, ou então, com medição dos coeficientes de pressão em modelos fechados, nas faces onde estão localizadas as aberturas. A metodologia com medição dos coeficientes de pressão, que exige o emprego de um modelo teórico para calcular as vazões, é a forma convencional de usar o túnel de vento como ferramenta no projeto de ventilação. O objetivo deste trabalho é avaliar os procedimentos citados, para calcular as vazões de ventilação por efeito do vento em pavilhões industriais. Para atingir esse objetivo foram ensaiados em túnel de vento dois modelos reduzidos (escala geométrica 1:200) de um pavilhão industrial: um sem aberturas, para a medição dos coeficientes de pressão, e outro, com aberturas de ventilação de área variável, para a medição das velocidades do vento com anemômetro de fio quente. Além da comparação das duas metodologias para determinação das vazões de ventilação, os resultados dos ensaios foram também utilizados para analisar as alterações nas vazões de ventilação e nas velocidades do escoamento do ar decorrentes do fechamento de algumas aberturas do modelo estudado. Conclui-se que as aberturas localizadas na cumeeira e o tipo de escoamento exercem grande influência nas vazões de ventilação. A utilização da metodologia de medição direta de velocidades através de anemômetro de fio quente permite a obtenção de vazões de ventilação sem iterações, com resultados compatíveis com os modelos teóricos que se baseiam na diferença de pressões externas e internas. / Natural ventilation in industrial buildings may be promoted by two mechanisms: one due to wind effects and other called chimney effect. However, the two mechanisms may also occur simultaneously. The determination of wind induced ventilation flows in industrial buildings may be performed through wind tunnel tests, with measurement of discharge velocity at openings, or else, with measurement of the pressure coefficients at the face of the buildings, where the openings are located. The methodology which employs the pressure coefficients requires the use of a theoretical model to calculate the flows, being the conventional way of using the wind tunnel as a tool in the ventilation project. The objective of this work is to evaluate the experimental procedures previously mentioned in order to be able to calculate the wind induced ventilation flows in industrial buildings. To reach this objective, two reduced models of an industrial building were tested at a geometric scale 1:200; one without openings, for the measurement of the pressure coefficients, and the other with ventilation openings with variable area, for the measurement of the wind velocities by the use of hot-wire anemometer. Different opening combinations were also tested and the flows analyzed. It is concluded that the opening types and the different flows exert a big influence in the ventilation flows and, therefore, in the natural ventilation itself. Also, the direct velocity measurement technique, through hot-wire anemometer, allows the ventilation flows to obtained directly, without interactions, being the results compatible with the theoretical models based on pressure differences.
|
3 |
Estudo da ventilação natural por efeito do vento em pavilhões industriais utilizando modelos reduzidos / The use of reduced models in the study of wind induced natural ventilation in industrial buildingsNunes, Daniel Alexandre January 2006 (has links)
A ventilação natural pode ser promovida por dois mecanismos: o denominado efeito chaminé e o efeito dos ventos, porém também podem ocorrer os dois mecanismos simultaneamente. A determinação das vazões de ventilação por efeito do vento, em pavilhões industriais, pode ser realizada a partir de ensaios de modelos reduzidos em túnel de vento, com medição das velocidades do escoamento nas aberturas, ou então, com medição dos coeficientes de pressão em modelos fechados, nas faces onde estão localizadas as aberturas. A metodologia com medição dos coeficientes de pressão, que exige o emprego de um modelo teórico para calcular as vazões, é a forma convencional de usar o túnel de vento como ferramenta no projeto de ventilação. O objetivo deste trabalho é avaliar os procedimentos citados, para calcular as vazões de ventilação por efeito do vento em pavilhões industriais. Para atingir esse objetivo foram ensaiados em túnel de vento dois modelos reduzidos (escala geométrica 1:200) de um pavilhão industrial: um sem aberturas, para a medição dos coeficientes de pressão, e outro, com aberturas de ventilação de área variável, para a medição das velocidades do vento com anemômetro de fio quente. Além da comparação das duas metodologias para determinação das vazões de ventilação, os resultados dos ensaios foram também utilizados para analisar as alterações nas vazões de ventilação e nas velocidades do escoamento do ar decorrentes do fechamento de algumas aberturas do modelo estudado. Conclui-se que as aberturas localizadas na cumeeira e o tipo de escoamento exercem grande influência nas vazões de ventilação. A utilização da metodologia de medição direta de velocidades através de anemômetro de fio quente permite a obtenção de vazões de ventilação sem iterações, com resultados compatíveis com os modelos teóricos que se baseiam na diferença de pressões externas e internas. / Natural ventilation in industrial buildings may be promoted by two mechanisms: one due to wind effects and other called chimney effect. However, the two mechanisms may also occur simultaneously. The determination of wind induced ventilation flows in industrial buildings may be performed through wind tunnel tests, with measurement of discharge velocity at openings, or else, with measurement of the pressure coefficients at the face of the buildings, where the openings are located. The methodology which employs the pressure coefficients requires the use of a theoretical model to calculate the flows, being the conventional way of using the wind tunnel as a tool in the ventilation project. The objective of this work is to evaluate the experimental procedures previously mentioned in order to be able to calculate the wind induced ventilation flows in industrial buildings. To reach this objective, two reduced models of an industrial building were tested at a geometric scale 1:200; one without openings, for the measurement of the pressure coefficients, and the other with ventilation openings with variable area, for the measurement of the wind velocities by the use of hot-wire anemometer. Different opening combinations were also tested and the flows analyzed. It is concluded that the opening types and the different flows exert a big influence in the ventilation flows and, therefore, in the natural ventilation itself. Also, the direct velocity measurement technique, through hot-wire anemometer, allows the ventilation flows to obtained directly, without interactions, being the results compatible with the theoretical models based on pressure differences.
|
4 |
Estudo da ventilação natural por efeito do vento em pavilhões industriais utilizando modelos reduzidos / The use of reduced models in the study of wind induced natural ventilation in industrial buildingsNunes, Daniel Alexandre January 2006 (has links)
A ventilação natural pode ser promovida por dois mecanismos: o denominado efeito chaminé e o efeito dos ventos, porém também podem ocorrer os dois mecanismos simultaneamente. A determinação das vazões de ventilação por efeito do vento, em pavilhões industriais, pode ser realizada a partir de ensaios de modelos reduzidos em túnel de vento, com medição das velocidades do escoamento nas aberturas, ou então, com medição dos coeficientes de pressão em modelos fechados, nas faces onde estão localizadas as aberturas. A metodologia com medição dos coeficientes de pressão, que exige o emprego de um modelo teórico para calcular as vazões, é a forma convencional de usar o túnel de vento como ferramenta no projeto de ventilação. O objetivo deste trabalho é avaliar os procedimentos citados, para calcular as vazões de ventilação por efeito do vento em pavilhões industriais. Para atingir esse objetivo foram ensaiados em túnel de vento dois modelos reduzidos (escala geométrica 1:200) de um pavilhão industrial: um sem aberturas, para a medição dos coeficientes de pressão, e outro, com aberturas de ventilação de área variável, para a medição das velocidades do vento com anemômetro de fio quente. Além da comparação das duas metodologias para determinação das vazões de ventilação, os resultados dos ensaios foram também utilizados para analisar as alterações nas vazões de ventilação e nas velocidades do escoamento do ar decorrentes do fechamento de algumas aberturas do modelo estudado. Conclui-se que as aberturas localizadas na cumeeira e o tipo de escoamento exercem grande influência nas vazões de ventilação. A utilização da metodologia de medição direta de velocidades através de anemômetro de fio quente permite a obtenção de vazões de ventilação sem iterações, com resultados compatíveis com os modelos teóricos que se baseiam na diferença de pressões externas e internas. / Natural ventilation in industrial buildings may be promoted by two mechanisms: one due to wind effects and other called chimney effect. However, the two mechanisms may also occur simultaneously. The determination of wind induced ventilation flows in industrial buildings may be performed through wind tunnel tests, with measurement of discharge velocity at openings, or else, with measurement of the pressure coefficients at the face of the buildings, where the openings are located. The methodology which employs the pressure coefficients requires the use of a theoretical model to calculate the flows, being the conventional way of using the wind tunnel as a tool in the ventilation project. The objective of this work is to evaluate the experimental procedures previously mentioned in order to be able to calculate the wind induced ventilation flows in industrial buildings. To reach this objective, two reduced models of an industrial building were tested at a geometric scale 1:200; one without openings, for the measurement of the pressure coefficients, and the other with ventilation openings with variable area, for the measurement of the wind velocities by the use of hot-wire anemometer. Different opening combinations were also tested and the flows analyzed. It is concluded that the opening types and the different flows exert a big influence in the ventilation flows and, therefore, in the natural ventilation itself. Also, the direct velocity measurement technique, through hot-wire anemometer, allows the ventilation flows to obtained directly, without interactions, being the results compatible with the theoretical models based on pressure differences.
|
5 |
Estudo da influência da modelagem estrutural do núcleo nos painéis de contraventamento de edifícios altos / Study of the influence of the structural modeling of the cores in the bracing panels of tall buildingsPereira, Ana Claudia de Oliveira 30 August 2000 (has links)
O núcleo resistente, considerado um dos principais elementos componentes dos sistemas estruturais de edifícios de andares múltiplos, quando associado ao sistema de contraventamento, consegue conferir à estrutura um razoável acréscimo de rigidez. O núcleo é ainda o único elemento estrutural capaz de resistir isoladamente a todos os esforços atuantes na estrutura de um edifício, contribuindo na determinação mais precisa dos seus deslocamentos. Baseado nestes fatores, acredita-se que as diferentes modelagens, adotadas para o núcleo, proporcionarão diferentes resultados para a mesma estrutura de contraventamento. Este trabalho tem como principal objetivo analisar a influência que estas modelagens exercem na estrutura de contraventamento. Inicialmente, são apresentadas algumas das modelagens mais utilizadas para o núcleo. Com estas modelagens foram processadas algumas estruturas, e os diversos resultados obtidos utilizados no processo comparativo. Para o processamento foram consideradas análises em teoria de primeira e segunda ordem e, para as fundações, vinculação rígida. Não serão consideradas as deformações por esforço cortante nos elementos. / Resistant cores, are considered one of the principal elements of the structural systems of multistory buildings. When associated to the bracing structure, it gives to the structure a reasonable stiffness increment. The core is still the only structural element capable to resist separately all the efforts in the structure of a building, contributing to a more accurate determination of its displacements. Based on these factors, it is believed that different modeling adopted for the cores will provide different results for the same bracing structure. The main aim of this work is to analyze the influence that these modeling exerts on the bracing structure. First, some of the most used core modeling were presented. Then some structures were processed, using these modeling. The several obtained results were compared. For all the analysis it was considered the first and second order theory and rigid connections for the foundations. Shear deformation were not considered in the elements.
|
6 |
Contribuições à análise de estruturas de contraventamento de edifícios em concreto armado / Contributions for analysis of bracing structures for reinforced concrete buildingsPereira, Gustavo Souza 16 May 1997 (has links)
Este trabalho trata de detalhes de modelagem de estruturas de contraventamento de edifícios de concreto armado. Inicialmente são discutidos esquemas de modelagem para núcleos de rigidez. São comparados resultados obtidos através de três procedimentos distintos, com diferentes graus de simplicidade e eficiência. É também avaliada a contribuição de vigas secundárias, vigas que não estão conectadas diretamente em pilares, na estrutura de contraventamento. Para tanto são apresentados alguns arranjos onde a consideração das referidas vigas muda significativamente os resultados obtidos e a modelagem de uma estrutura completa de edifício com e sem as referidas vigas secundárias. Por fim, são apresentados um gerador de estruturas de contraventamento e um pós-processador gráfico para visualização da estrutura gerada e dos resultados obtidos, sejam esforços ou deslocamentos. / This work deals with some modelling details of bracing structures for reinforced concrete buildings. lnitially, modelling schemes of structural cores are discussed. Results obtained by three different procedures, with distinct levels of simplicity and efficacy, are compared. The work also shows the contribution of secondary beams, ones that are not directly connected to columns, to the stiffness of bracing structures. Some schemes, in which the consideration of those beams changes expressively the obtained results, and the complete modelling of a building structure, with and without secondary beams, are presented. Finally, the work also introduces a generator of bracing structures and a pos-processor, that permit the visualisation of the obtained results: internal efforts and displacements.
|
7 |
Análise dinâmica de suportes para antenas em torres metálicas para telecomunicaçõesSANTOS, Ives José Adriano dos 11 December 2015 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2016-12-12T15:55:02Z
No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Dissertação de mestrado - Análise dinâmica de torres para telecomunicações (Revisão Definitiva).pdf: 5572516 bytes, checksum: 3aeb29a09ea2819f49316a79c5388a73 (MD5) / Made available in DSpace on 2016-12-12T15:55:02Z (GMT). No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Dissertação de mestrado - Análise dinâmica de torres para telecomunicações (Revisão Definitiva).pdf: 5572516 bytes, checksum: 3aeb29a09ea2819f49316a79c5388a73 (MD5)
Previous issue date: 2015-12-11 / Na última década, o crescimento da telefonia celular no Brasil venceu os limites das grandes capitais, levando a rede a cobrir municípios antes desprovidos de tal tecnologia. A transmissão do sinal pode ocorrer de diversas formas, mas, de fato, a mais comumente utilizada é por meio de antenas sustentadas por torres metálicas.
Na prática, as antenas são instaladas em qualquer momento após a montagem da torre, mesmo anos após sua construção, sem qualquer verificação estrutural e, por vezes, excedendo a capacidade de carga nominal. Além disso, na maioria dos casos, não são levados em conta certos cuidados com relação ao posicionamento de suportes e das próprias antenas. Portanto, é comum encontrarmos antenas instaladas de forma inadequada, sendo colocadas fora da silhueta da torre. Este posicionamento, aliado com a ação dinâmica ocasionada pelo vento, pode trazer problemas graves à estrutura. Neste trabalho, são apresentados dois casos reais de torres metálicas que sofreram danos estruturais devido ao problema em questão.
Este trabalho tem como principal objetivo apresentar uma solução de amortecimento para as vibrações causadas pelo vento em antenas para telecomunicações. A proposta visa utilizar elastômeros, como o Neoprene, entre a cantoneira do montante e as abraçadeiras dos suportes, reduzindo assim o período de vibração e, consequentemente, os efeitos da fadiga. / In the last decade, the growth of mobile telephony in Brazil won the boundaries of the great capitals, leading the network to cover cities before devoid of such technology. The signal transmission can occur in various ways, but, in fact, the most commonly used is through antennas supported by steel towers. In practice, the antennas are installed at any time after assembly of the tower, even years after its construction, without any structural verification and sometimes exceeding the rated load capacity. Moreover, in most cases, care is not taken into account in relation to the positioning brackets and their antennas. Therefore, it is common to find antennas installed improperly, being placed outside the tower silhouette. This positioning, combined with dynamic action brought by the wind, can bring serious problems to the structure. In this work, we present two real cases of metal towers that have suffered structural damage due to the problem at hand. The objective of this work is to present a solution for damping the vibrations caused by the wind in telecommunications antennas. The proposal to use elastomers, such as neoprene, between the bracket and the tower column, thus reducing the vibration period and, consequently, the effects of fatigue.
|
8 |
Contribuições à análise de estruturas de contraventamento de edifícios em concreto armado / Contributions for analysis of bracing structures for reinforced concrete buildingsGustavo Souza Pereira 16 May 1997 (has links)
Este trabalho trata de detalhes de modelagem de estruturas de contraventamento de edifícios de concreto armado. Inicialmente são discutidos esquemas de modelagem para núcleos de rigidez. São comparados resultados obtidos através de três procedimentos distintos, com diferentes graus de simplicidade e eficiência. É também avaliada a contribuição de vigas secundárias, vigas que não estão conectadas diretamente em pilares, na estrutura de contraventamento. Para tanto são apresentados alguns arranjos onde a consideração das referidas vigas muda significativamente os resultados obtidos e a modelagem de uma estrutura completa de edifício com e sem as referidas vigas secundárias. Por fim, são apresentados um gerador de estruturas de contraventamento e um pós-processador gráfico para visualização da estrutura gerada e dos resultados obtidos, sejam esforços ou deslocamentos. / This work deals with some modelling details of bracing structures for reinforced concrete buildings. lnitially, modelling schemes of structural cores are discussed. Results obtained by three different procedures, with distinct levels of simplicity and efficacy, are compared. The work also shows the contribution of secondary beams, ones that are not directly connected to columns, to the stiffness of bracing structures. Some schemes, in which the consideration of those beams changes expressively the obtained results, and the complete modelling of a building structure, with and without secondary beams, are presented. Finally, the work also introduces a generator of bracing structures and a pos-processor, that permit the visualisation of the obtained results: internal efforts and displacements.
|
9 |
Estudo da influência da modelagem estrutural do núcleo nos painéis de contraventamento de edifícios altos / Study of the influence of the structural modeling of the cores in the bracing panels of tall buildingsAna Claudia de Oliveira Pereira 30 August 2000 (has links)
O núcleo resistente, considerado um dos principais elementos componentes dos sistemas estruturais de edifícios de andares múltiplos, quando associado ao sistema de contraventamento, consegue conferir à estrutura um razoável acréscimo de rigidez. O núcleo é ainda o único elemento estrutural capaz de resistir isoladamente a todos os esforços atuantes na estrutura de um edifício, contribuindo na determinação mais precisa dos seus deslocamentos. Baseado nestes fatores, acredita-se que as diferentes modelagens, adotadas para o núcleo, proporcionarão diferentes resultados para a mesma estrutura de contraventamento. Este trabalho tem como principal objetivo analisar a influência que estas modelagens exercem na estrutura de contraventamento. Inicialmente, são apresentadas algumas das modelagens mais utilizadas para o núcleo. Com estas modelagens foram processadas algumas estruturas, e os diversos resultados obtidos utilizados no processo comparativo. Para o processamento foram consideradas análises em teoria de primeira e segunda ordem e, para as fundações, vinculação rígida. Não serão consideradas as deformações por esforço cortante nos elementos. / Resistant cores, are considered one of the principal elements of the structural systems of multistory buildings. When associated to the bracing structure, it gives to the structure a reasonable stiffness increment. The core is still the only structural element capable to resist separately all the efforts in the structure of a building, contributing to a more accurate determination of its displacements. Based on these factors, it is believed that different modeling adopted for the cores will provide different results for the same bracing structure. The main aim of this work is to analyze the influence that these modeling exerts on the bracing structure. First, some of the most used core modeling were presented. Then some structures were processed, using these modeling. The several obtained results were compared. For all the analysis it was considered the first and second order theory and rigid connections for the foundations. Shear deformation were not considered in the elements.
|
10 |
Höga hus i trä- dynamiska vindpåverkan och brandrisk / High building in wood- dynamic-wind effect and fire risksMohammad, Raidi January 2021 (has links)
Stort intresse har väckts för höga trähus den senaste tiden. Vi är nu i en tid där höga trähus går från teoretiska koncept till verkliga byggnader. Norge har världens högsta träbyggnad med dess 84 meter över marken. Mjöstårnet i Brumddal har lett till djupare förståelse för de dynamiska parametrar som är viktiga för dess konstruktioner. Men även både i Sverige och Kanada planeras högre flervåningshus i trä. Målet med detta examensarbete är att titta närmare på de utmaningarna som uppstår när man bygger höga trähus. För att kunna utföra undersökningen har litteratur studerats samt har intervjuer genomförts med erfarna aktörer inom byggbranschen som är inriktade inom trähus. En av de största utmaningarna är dynamisk vindpåverkan med hänsyn till träs låga vikt, en annan är brand med tanke på att trä är ett brännbart material. Resultaten visar att massa är det viktigaste faktorn som avgör hur byggnaden påverkas av vindlasten. Genom att öka byggnadens totala massa i överdelen innebär att byggnaden kommer vara tyngre mot toppen. Ju mer massa desto mindre svängningar. Brandproblematiken är något som i stor del redan är löst och man klarar ganska lätt av att uppskatta brandkrav. Dock är det betydligt svårare när det kommer till Br0-byggnader. Resultaten visar att eurokoder är diffust skrivet i hela brandkapitlet då ett högt hus av trä måste överdimensioneras. Slutsatsen visas att trä som bärande stomme är ett utmärkt stomalternativ till betong och stål med tanke på koldioxidutsläpp. Det finns många fördelar med att bygga i trä, bland annat har trä hög hållfasthet i förhållande med sin egentyngd vilket resulterar att transporten blir billigare, det skapar möjligheter att bearbeta med trä inomhus, byggtiden bli kortare då inga torktider behöver beaktas såväl som att trä är ett förnybart material. / There is a great interest in tall timber buildings. We are now in a time when tall timber buildings has gone from theoretical concepts to real buildings. Norway has the world’s tallest timber buildings with it’s 84 meters above the ground. Thanks to Mjöstårnet in Brumddal, we have gained a deeper understanding of the dynamic parameters that are important for these constructions. But also, in both Sweden and Canada, higher multistorey timber buildings are planned. The aim of this work is to take a closer look at the challenges that arise when tall timber buildings are built. In order to be able to carry out the survey, literature has been studied and interviews have been conducted with experienced players in the construction industry who are focused on timber buildings. One of the biggest challenges is the dynamic wind effect with regard to the low weight of wood. While the other is fire considering wood is a combustible material. The results show that mass is the most important factor that determines how the building is affected by the wind load. By increasing the building’s total mass in the upper part means that the building will be heavier towards the top. The more mass, the less oscillations. Fire the problem is something that has largely already been solved and it is quite easy to estimate fire requirements. However, it is much more difficult when it com s to Br0-buildings. The results show that Eurocodes are diffusely written throughout the fire chapter as a tall timber building must over dimension. The conclusion is shown that wood is like a load-bearing frame and is an excellent frame alternative to concrete and steel. There are many other advantages to building in wood, among other things, wood has high strength in relation to its own weight, which results in transport being cheaper, it creates opportunities to process with wood indoors, construction time is shorter.
|
Page generated in 0.0418 seconds