A Novel Highly Accurate Wireless Wearable Human Locomotion Tracking and Gait Analysis System via UWB RadiosShaban, Heba Ahmed 09 June 2010 (has links)
Gait analysis is the systematic study of human walking. Clinical gait analysis is the process by which quantitative information is collected for the assessment and decision-making of any gait disorder. Although observational gait analysis is the therapist's primary clinical tool for describing the quality of a patient's walking pattern, it can be very unreliable. Modern gait analysis is facilitated through the use of specialized equipment. Currently, accurate gait analysis requires dedicated laboratories with complex settings and highly skilled operators. Wearable locomotion tracking systems are available, but they are not sufficiently accurate for clinical gait analysis. At the same time, wireless healthcare is evolving. Particularly, ultra wideband (UWB) is a promising technology that has the potential for accurate ranging and positioning in dense multi-path environments. Moreover, impulse-radio UWB (IR-UWB) is suitable for low-power and low-cost implementation, which makes it an attractive candidate for wearable, low-cost, and battery-powered health monitoring systems. The goal of this research is to propose and investigate a full-body wireless wearable human locomotion tracking system using UWB radios. Ultimately, the proposed system should be capable of distinguishing between normal and abnormal gait, making it suitable for accurate clinical gait analysis. / Ph. D.
|
2 |
Efficient Wireless Communication in Healthcare Systems; Design and Performance EvaluationRashwand, Saeed January 2012 (has links)
Increasing number of ageing population and people who need continuous health monitoring and rising the costs of health care have triggered the concept of the novel wireless technology-driven human body monitoring. Human body monitoring can be performed using a network of small and intelligent wireless medical sensors which may be attached to the body surface or implanted into the tissues. It enables carers to predict, diagnose, and react to adverse events earlier than ever. The concept of Wireless Body Area Network (WBAN) was introduced to fully exploit the benefits of wireless technologies in telemedicine and m-health.
The main focus of this research is the design and performance evaluation of strategies and architectures that would allow seamless and efficient interconnection of patient’s body area network and the stationary (e.g., hospital room or ward) wireless networks. I first introduce the architecture of a healthcare system which bridges WBANs and Wireless Local Area Networks (WLANs). I adopt IEEE 802.15.6 standard for the patient’s body network because it is specifically designed for WBANs. Since IEEE 802.15.6 has strict Quality of Service (QoS) and priorities to transfer the medical data to the medical server a QoS-enabled WLAN for the next hop is needed to preserve the end-to-end QoS. IEEE 802.11e standard is selected for the WLAN in the hospital room or ward because it provides prioritization for the stations in the network. I investigate in detail the requirements posed by different healthcare parameters and to analyze the performance of various alternative interconnection strategies, using the rigorous mathematical apparatus of Queuing Theory and Probabilistic Analysis; these results are independently validated through discrete event simulation models.
This thesis has three main parts; performance evaluation and MAC parameters settings of IEEE 802.11e Enhanced Distributed Channel Access (EDCA), performance evaluation and tuning the MAC parameters of IEEE 802.15.6, and designing a seamless and efficient interconnection strategy which bridges IEEE 802.11e EDCA and IEEE 802.15.6 standards for a healthcare system.
|
3 |
Efficient Wireless Communication in Healthcare Systems; Design and Performance EvaluationRashwand, Saeed January 2012 (has links)
Increasing number of ageing population and people who need continuous health monitoring and rising the costs of health care have triggered the concept of the novel wireless technology-driven human body monitoring. Human body monitoring can be performed using a network of small and intelligent wireless medical sensors which may be attached to the body surface or implanted into the tissues. It enables carers to predict, diagnose, and react to adverse events earlier than ever. The concept of Wireless Body Area Network (WBAN) was introduced to fully exploit the benefits of wireless technologies in telemedicine and m-health.
The main focus of this research is the design and performance evaluation of strategies and architectures that would allow seamless and efficient interconnection of patient’s body area network and the stationary (e.g., hospital room or ward) wireless networks. I first introduce the architecture of a healthcare system which bridges WBANs and Wireless Local Area Networks (WLANs). I adopt IEEE 802.15.6 standard for the patient’s body network because it is specifically designed for WBANs. Since IEEE 802.15.6 has strict Quality of Service (QoS) and priorities to transfer the medical data to the medical server a QoS-enabled WLAN for the next hop is needed to preserve the end-to-end QoS. IEEE 802.11e standard is selected for the WLAN in the hospital room or ward because it provides prioritization for the stations in the network. I investigate in detail the requirements posed by different healthcare parameters and to analyze the performance of various alternative interconnection strategies, using the rigorous mathematical apparatus of Queuing Theory and Probabilistic Analysis; these results are independently validated through discrete event simulation models.
This thesis has three main parts; performance evaluation and MAC parameters settings of IEEE 802.11e Enhanced Distributed Channel Access (EDCA), performance evaluation and tuning the MAC parameters of IEEE 802.15.6, and designing a seamless and efficient interconnection strategy which bridges IEEE 802.11e EDCA and IEEE 802.15.6 standards for a healthcare system.
|