• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 1
  • Tagged with
  • 34
  • 34
  • 34
  • 25
  • 24
  • 20
  • 20
  • 20
  • 19
  • 12
  • 9
  • 8
  • 8
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Implantação de radiações de referência em máquina de raios X diagnóstico médico para fins de calibração de dosímetros pessoais

Annibal Theotonio Baptista Neto 28 February 2005 (has links)
Nenhuma / Campos de raios-x que estejam em conformidade com os requisitos internacionais de padronização nem sempre são disponíveis em uma região e, principalmente, em países em desenvolvimento. Esta situação tem sido usada como justificativa para a ausência de calibração de dosímetros pessoais e tem contribuído para a falta de confiabilidade nos programas de monitoração de trabalhadores expostos à radiação. Considerando a existência de diversas máquinas de raios-x em hospitais e a necessidade da calibração de dosímetros pessoais, este trabalho investigou a viabilidade da implantação de feixes de radiação-x destinados à calibração, comparáveis às radiações padronizadas internacionalmente, em uma máquina de raios-x diagnóstico médico. A implantação das radiações para calibração foi realizada com a determinação e comparação de parâmetros dos feixes de raios-x como a tensão do tubo, camada semi-redutora, uniformidade do campo de radiação, filtração e radiação espalhada. Os procedimentos, a geometria e as condições de irradiação foram, sempre, os mais simples possíveis para uma confiabilidade mínima dos resultados, nas condições usuais em hospitais. A viabilidade do uso dos feixes de radiação implantados foi confirmado através da análise do desempenho de um dosímetro pessoal do tipo filme, em calibrações e irradiações no Laboratório de Calibração de Dosímetros do Centro de Desenvolvimento da Tecnologia Nuclear, no Laboratório Nacional de Metrologia das Radiações Ionizantes e no University of Wisconsin Radiation Calibration Laboratory. Apesar da diferença entre os feixes de raios-x implantados e as radiações de referência, o desempenho do dosímetro pessoal atendeu aos requisitos para a monitoração individual. / X-ray fields that comply with international standardization requirements are not available in a world region, mainly in developing countries. This is used as an excuse for a lack of calibration of personal dosimeters and, consequently, a lack of reliability in individual monitoring programs applied to occupational workers under radiation exposures. Considering the availability of x-ray machines in many hospitals, this work studied the feasibility of implementing x-ray calibration beams in a medical diagnostic machine, which are comparable to international reference radiations for calibrating personal dosimeters. Implementation of the calibration beams was carried out by determining and comparing beam parameters as tube voltage, half-value layer, beam uniformity, filtration and scattered radiation. Procedures, geometry and exposure conditions were as simple as possible for a minimum reliability and close to the hospital conditions. The feasibility of the use of the implemented radiation beams was confirmed by analyzing the performance of a film personal dosimeter under calibration and irradiation at the Dosimeter Calibration Laboratory of the Centro de Desenvolvimento da Tecnologia Nuclear, the National Metrology Laboratory for Ionizing Radiations and the University of Wisconsin Radiation Calibration Laboratory. In spite of the difference between the implemented x-ray beams and the reference radiations, the performance of the film personal dosimeter complied with the accuracy requirements for individual monitoring.
Read more
22

Elaboração de um procedimento para controle de qualidade em sistemas de radiodiagnóstico odontológico / Quality control procedures of dental diagnostic radiology systems

Paula Serra Sasaki Andrade 27 March 2007 (has links)
O trabalho apresenta uma metodologia para aplicação de procedimentos de referência, seguindo as recomendações da Portaria Federal n° 453 do Ministério da Saúde (PF 453), para controle de qualidade em sistemas de radiodiagnóstico odontológico, que possa ser aplicada em consultórios odontológicos, visando uma melhoria na qualidade da imagem radiológica e a diminuição da dose no paciente. Foram realizados testes em um equipamento de raios X intrabucal, seguindo uma metodologia desenvolvida neste trabalho e os requisitos da PF 453. Foi desenvolvido neste trabalho um objeto teste (objeto simulador) para a verificação da melhor qualidade de imagem em relação ao menor tempo de exposição. A utilização deste objeto permitiu a redução do tempo de exposição de 0,5 s, maior valor da região linear da curva característica, para 0,2 s. O sistema de raios X testado atendeu de maneira satisfatória à norma, destacando que a dose de entrada na pele diminuiu com o uso de posicionadores, mas o tamanho do campo aumentou e ultrapassou o valor máximo de 6cm recomendado nesta portaria. A importância do controle de qualidade em sistemas de radiodiagnóstico odontológico é evidenciada pelo uso rotineiro da radiação X nos consultórios odontológicos. A PF 453 recomenda a realização dos testes de constância com freqüência mínima de 2 anos, porém sugere-se que o próprio profissional, cirurgião-dentista, implemente seu controle interno da qualidade das radiografias obtidas em seu aparelho. Isto poderá ser executado por meio de exposições mensais do objeto teste (objeto simulador) desenvolvido neste trabalho. / This work presents quality control reference procedures for dental diagnostic radiology systems, following the recommendations of the Publication 453 of the Brazilian Health Ministry (PF 453), to be applied in dental clinics, in order to achieve an improvement in the radiological image qualities and the patient dose reduction. All tests were applied in an intraoral X rays system, following the methodology developed and the requirements of the PF 453. In order to verify the best quality of the image in relation to the smaller exposition time an object test was also developed in this work. The use of this object allowed the reduction of the exposition time of 0.5 seconds, the maximum value of the linear region of the characteristic curve, for 0.2 seconds. The tested X rays system showed a very good agreement with the applied procedures, detaching the reduction of the skin entrance dose using the film-holding devices. However, the size of the field increased and exceeded the maximum value of 6cm recommended in the standard. The importance of the quality control in dental diagnostic radiology systems is essential due to the constant use of X radiation in dental clinics. The PF453 recommends the frequency of at least two years for the constancy tests. However, it is suggested that the professional, surgeon-dentist, should be responsible for the internal control of the image quality obtained from the X rays device. This can be done through monthly exposures of the object test developed in this work.
Read more
23

Estabelecimento e controle de qualidade de feixes padroes de radiacao X para calibracao de instrumentos, nivel mamografia

GUERRA, ALINE B. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:41Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:10Z (GMT). No. of bitstreams: 1 07150.pdf: 9130636 bytes, checksum: cb7e14964ddd9719ff5fe8392bed1d90 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
24

Desenvolvimento de camaras de ionizacao Tandem para utilizacao em programas de controle da qualidade em radioterapia e radiodiagnostico

COSTA, ALESSANDRO M. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:48:23Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:11Z (GMT). No. of bitstreams: 1 08715.pdf: 4323271 bytes, checksum: 6c93cac5d8cfc34b7d3a208547cb8f8d (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP / FAPESP:98/14763-4
25

Avaliação de dispositivos de proteção individual utilizados em radiologia diagnóstica

SOARES, FERNANDA C.S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:52:11Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:13Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
26

Determinacao das dimensoes do ponto focal de tubos de raios X utilizando um sensor CCD e o metodo das funcoes de transferencias

NERSISSIAN, DENISE Y. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:49:54Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:02:15Z (GMT). No. of bitstreams: 1 10189.pdf: 7945514 bytes, checksum: fc959ff6c97125fc66c813f5c29a3647 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
27

Estabelecimento e controle de qualidade de feixes padroes de radiacao X para calibracao de instrumentos, nivel mamografia

GUERRA, ALINE B. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:41Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:10Z (GMT). No. of bitstreams: 1 07150.pdf: 9130636 bytes, checksum: cb7e14964ddd9719ff5fe8392bed1d90 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
28

Desenvolvimento de camaras de ionizacao Tandem para utilizacao em programas de controle da qualidade em radioterapia e radiodiagnostico

COSTA, ALESSANDRO M. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:48:23Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:11Z (GMT). No. of bitstreams: 1 08715.pdf: 4323271 bytes, checksum: 6c93cac5d8cfc34b7d3a208547cb8f8d (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP / FAPESP:98/14763-4
29

Avaliação de dispositivos de proteção individual utilizados em radiologia diagnóstica

SOARES, FERNANDA C.S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:52:11Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:13Z (GMT). No. of bitstreams: 0 / Neste trabalho foram avaliados aventais de proteção e blindagens de ovário de cinco fabricantes segundo as normas NBR / IEC 61331-1 e NBR / IEC 61331-3 de 2004. Para a determinação da espessura equivalente de atenuação foram aplicadas três metodologias diferentes (interpolação linear, modelo de Archer e somatório de exponenciais), uma vez que a norma não indica como este valor deve ser obtido. Além disso, foram estimadas as incertezas associadas a cada método e a influência do número de medições na incerteza combinada. As características de confecção avaliadas foram: documento acompanhante, projeto, materiais, dimensões e marcação da etiqueta. Para esta avaliação foi elaborado um formulário que contemplava todas as exigências da NBR / IEC 61331-3. Os resultados mostraram uma grande diferença entre os valores de espessura equivalente de atenuação declarados e medidos. A comparação dos resultados das três metodologias aplicadas mostrou que há pouca variação entre os valores obtidos e entre as incertezas associadas nas diferentes metodologias. Foi possível observar também que o número de medições não contribui significativamente para o aumento da incerteza nas três metodologias. A metodologia que melhor se adequou à rotina do laboratório foi a metodologia da interpolação linear com cinco medições da taxa de kerma no ar. A discrepância entre os resultados apresentados neste trabalho e as exigências das normas estudadas mostra a necessidade de tornar compulsória a certificação dos dispositivos de proteção, contribuindo assim para o aumento da proteção radiológica do usuário. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
Read more
30

Determinacao das dimensoes do ponto focal de tubos de raios X utilizando um sensor CCD e o metodo das funcoes de transferencias

NERSISSIAN, DENISE Y. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:49:54Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:02:15Z (GMT). No. of bitstreams: 1 10189.pdf: 7945514 bytes, checksum: fc959ff6c97125fc66c813f5c29a3647 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP

Page generated in 0.0736 seconds