• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influência da taxa de aplicação superficial e da concentração de ar na eficiência de clarificação de água de abastecimento em unidades de flotação por ar dissolvido / Influence of surface application fee and concentration of air in efficiency of clarification of water supply in units dissolved air flotation

Escher, Aline Eléia 22 September 2011 (has links)
Os objetivos deste trabalho foram verificar a influência das taxas de aplicação superficial das zonas de separação e de contato e da concentração de micro bolhas de ar na eficiência da remoção de partículas em unidades de flotação aplicadas ao tratamento de água para abastecimento público e, caracterizar a estrutura de escoamento no interior da zona de separação, com a utilização de uma planta piloto de flotação por ar dissolvido. Os trabalhos relativos à pesquisa foram divididos em duas etapas: a primeira delas contemplou a operação de unidade piloto alimentada com água sintética, utilizando três valores de taxa de aplicação superficial na zona de separação associadas a duas taxas de aplicação superficial na zona de contato, cada qual com três concentrações de ar fornecido à flotação. Foram mantidos fixos os parâmetros: tempo de contato na zona de contato, tempo de floculação, gradiente médio de floculação e velocidade cross-flow. Os resultados desta etapa foram monitorados com base na eficiência de remoção de cor e turbidez. As maiores eficiências de remoção, 87,5% para turbidez e 96,8% de cor aparente foram obtidos para as menores taxas de aplicação superficial nas zonas de contato e separação estudadas, associadas à concentração de ar de 4,90 g/\'CM POT.3\' de água. Este, entre outros resultados, levou à conclusão de que tal concentração de ar fornecida à flotação forneceu sempre os menores residuais de cor e turbidez nas condições investigadas. Quanto à taxa de aplicação superficial na zona de contato, 136,3 m/h resultou em maiores eficiências de clarificação, sendo que o aumento para 172,8 m/h causou ligeira queda na eficiência. Finalmente, quanto à taxa de aplicação superficial na zona de separação, a menor taxa (9,8 m/h) foi aquela onde as maiores eficiências de clarificação foram obtidas, as quais decresceram à medida que a taxa foi aumentada. Na segunda etapa utilizou-se a sonda microADV na caracterização do escoamento no interior da zona de separação. Foram realizadas caracterizações para as três concentrações de ar fornecidas para a flotação estudadas na etapa I, mantendo-se fixos a taxa de aplicação superficial e o tempo na zona de contato (136,3 m/h e 53 s, respectivamente), a taxa de aplicação superficial na zona de separação (12,3 m/h), a vazão de entrada e a velocidade cross-flow, conforme a etapa I. Para as três condições estudadas, adotou-se uma malha virtual de coleta de dados de duas dimensões, composta por 98 pontos igualmente espaçados, sendo 14 na altura e 7 paralelos ao comprimento. O tempo de coleta de dados em cada ponto foi de 2 min com uma freqüência de amostragem de 50 Hz. Os vetores de velocidade resultantes foram plotados em esquemas ilustrativos, afim de se comparar os três perfis obtidos. Observou-se em todos os casos um fluxo em curto-circuito na região superior da zona de separação e logo abaixo desta, um fluxo descendente no sentido dos coletores ao fundo da unidade. Quando comparadas, apenas pequenas diferenças quanto à espessura da região de curto circuito superior foram verificadas entre as três situações abordadas, as quais não explicam as diferentes eficiências de clarificação obtidas na etapa I da pesquisa, relacionadas à concentração de ar fornecida à flotação. / The objectives of this study were to determine the influence of hydraulic surface loading of contact and separation zones and of the air micro bubbles concentration in the particle removal efficiency in flotation units applied to water treatment for public supply and also characterize the flow structure into the separation zone. The works were divided into two stages: the first included the operation of the pilot plant fed with synthetic water, using three values of hydraulic surface loadings in the separation zone associated with two hydraulic surface loadings in the superficial zone of contact, each one with three concentrations of air supplied to the flotation. Were kept fixed parameters: contact time in the contact zone, flocculation time, mean flocculation gradient and cross-flow velocity. The results of this step were monitored based on the removal efficiency of color and turbidity. The higher removal efficiencies, 87.5% of turbidity and 96.8% apparent color were obtained for the lower hydraulic surface loading of contact and separation zones studied, associated with air concentration of 4.90 g/\'CM POT.3\' of water. This, among other results, led to the conclusion that this air supplied to the flotation concentration always provided the lowest residual color and turbidity values, under the conditions investigated. As for the hydraulic surface loading in the contact zone, 136.3 m/h resulted in higher efficiencies for clarification and when increasing to 172.8 m/h slight drop in efficiency was caused. Finally, regarding separation zone hydraulic surface loading, the lowest rate (9.8 m/h) was the one in which the highest efficiencies of clarification were obtained, which decreased, as the hydraulic surface loading was increased. In the second step, the probe microADV was used to characterize the flow inside the separation zone. Characterizations were carried out for the three air concentrations supplied to the flotation studied on the first step, fixing contact zone hydraulic surface loading and time (136.3 m/h and 53 s, respectively), the separation zone hydraulic surface loading (12.3 m/h), the input flow and cross-flow velocity as step I. For the three conditions studied, we adopted a of two-dimensional virtual data collection grid with 98 equally spaced points, 14 in height and 7 parallel to the length. The data collection time at each point was 2 min with a sampling frequency of 50 Hz. The resulting velocity vectors were plotted on illustrative diagrams in order to compare the three profiles obtained. A short-circuit flow in the upper part of the separation zone and below this, a downward flow toward the bottom of the collector unit were observed in all cases. In comparison, only small differences in the thickness of the upper region of short circuit were observed between the three situations discussed, which do not explain the different efficiencies of clarification obtained in the first step of the research related to the air bubble concentration.
2

Influência da taxa de aplicação superficial e da concentração de ar na eficiência de clarificação de água de abastecimento em unidades de flotação por ar dissolvido / Influence of surface application fee and concentration of air in efficiency of clarification of water supply in units dissolved air flotation

Aline Eléia Escher 22 September 2011 (has links)
Os objetivos deste trabalho foram verificar a influência das taxas de aplicação superficial das zonas de separação e de contato e da concentração de micro bolhas de ar na eficiência da remoção de partículas em unidades de flotação aplicadas ao tratamento de água para abastecimento público e, caracterizar a estrutura de escoamento no interior da zona de separação, com a utilização de uma planta piloto de flotação por ar dissolvido. Os trabalhos relativos à pesquisa foram divididos em duas etapas: a primeira delas contemplou a operação de unidade piloto alimentada com água sintética, utilizando três valores de taxa de aplicação superficial na zona de separação associadas a duas taxas de aplicação superficial na zona de contato, cada qual com três concentrações de ar fornecido à flotação. Foram mantidos fixos os parâmetros: tempo de contato na zona de contato, tempo de floculação, gradiente médio de floculação e velocidade cross-flow. Os resultados desta etapa foram monitorados com base na eficiência de remoção de cor e turbidez. As maiores eficiências de remoção, 87,5% para turbidez e 96,8% de cor aparente foram obtidos para as menores taxas de aplicação superficial nas zonas de contato e separação estudadas, associadas à concentração de ar de 4,90 g/\'CM POT.3\' de água. Este, entre outros resultados, levou à conclusão de que tal concentração de ar fornecida à flotação forneceu sempre os menores residuais de cor e turbidez nas condições investigadas. Quanto à taxa de aplicação superficial na zona de contato, 136,3 m/h resultou em maiores eficiências de clarificação, sendo que o aumento para 172,8 m/h causou ligeira queda na eficiência. Finalmente, quanto à taxa de aplicação superficial na zona de separação, a menor taxa (9,8 m/h) foi aquela onde as maiores eficiências de clarificação foram obtidas, as quais decresceram à medida que a taxa foi aumentada. Na segunda etapa utilizou-se a sonda microADV na caracterização do escoamento no interior da zona de separação. Foram realizadas caracterizações para as três concentrações de ar fornecidas para a flotação estudadas na etapa I, mantendo-se fixos a taxa de aplicação superficial e o tempo na zona de contato (136,3 m/h e 53 s, respectivamente), a taxa de aplicação superficial na zona de separação (12,3 m/h), a vazão de entrada e a velocidade cross-flow, conforme a etapa I. Para as três condições estudadas, adotou-se uma malha virtual de coleta de dados de duas dimensões, composta por 98 pontos igualmente espaçados, sendo 14 na altura e 7 paralelos ao comprimento. O tempo de coleta de dados em cada ponto foi de 2 min com uma freqüência de amostragem de 50 Hz. Os vetores de velocidade resultantes foram plotados em esquemas ilustrativos, afim de se comparar os três perfis obtidos. Observou-se em todos os casos um fluxo em curto-circuito na região superior da zona de separação e logo abaixo desta, um fluxo descendente no sentido dos coletores ao fundo da unidade. Quando comparadas, apenas pequenas diferenças quanto à espessura da região de curto circuito superior foram verificadas entre as três situações abordadas, as quais não explicam as diferentes eficiências de clarificação obtidas na etapa I da pesquisa, relacionadas à concentração de ar fornecida à flotação. / The objectives of this study were to determine the influence of hydraulic surface loading of contact and separation zones and of the air micro bubbles concentration in the particle removal efficiency in flotation units applied to water treatment for public supply and also characterize the flow structure into the separation zone. The works were divided into two stages: the first included the operation of the pilot plant fed with synthetic water, using three values of hydraulic surface loadings in the separation zone associated with two hydraulic surface loadings in the superficial zone of contact, each one with three concentrations of air supplied to the flotation. Were kept fixed parameters: contact time in the contact zone, flocculation time, mean flocculation gradient and cross-flow velocity. The results of this step were monitored based on the removal efficiency of color and turbidity. The higher removal efficiencies, 87.5% of turbidity and 96.8% apparent color were obtained for the lower hydraulic surface loading of contact and separation zones studied, associated with air concentration of 4.90 g/\'CM POT.3\' of water. This, among other results, led to the conclusion that this air supplied to the flotation concentration always provided the lowest residual color and turbidity values, under the conditions investigated. As for the hydraulic surface loading in the contact zone, 136.3 m/h resulted in higher efficiencies for clarification and when increasing to 172.8 m/h slight drop in efficiency was caused. Finally, regarding separation zone hydraulic surface loading, the lowest rate (9.8 m/h) was the one in which the highest efficiencies of clarification were obtained, which decreased, as the hydraulic surface loading was increased. In the second step, the probe microADV was used to characterize the flow inside the separation zone. Characterizations were carried out for the three air concentrations supplied to the flotation studied on the first step, fixing contact zone hydraulic surface loading and time (136.3 m/h and 53 s, respectively), the separation zone hydraulic surface loading (12.3 m/h), the input flow and cross-flow velocity as step I. For the three conditions studied, we adopted a of two-dimensional virtual data collection grid with 98 equally spaced points, 14 in height and 7 parallel to the length. The data collection time at each point was 2 min with a sampling frequency of 50 Hz. The resulting velocity vectors were plotted on illustrative diagrams in order to compare the three profiles obtained. A short-circuit flow in the upper part of the separation zone and below this, a downward flow toward the bottom of the collector unit were observed in all cases. In comparison, only small differences in the thickness of the upper region of short circuit were observed between the three situations discussed, which do not explain the different efficiencies of clarification obtained in the first step of the research related to the air bubble concentration.
3

Influência do gradiente médio de velocidade na zona de contato na eficiência de clarificação de água para abastecimento por flotação / Influence of the velocity gradient in the contact zone in the efficiency of clarification of potable water by flotation

Souza, Irene Monteiro da Franca 13 September 2012 (has links)
O presente trabalho teve como objetivo estudar a influência do gradiente médio de velocidade (Gzc), associado ao tempo de detenção hidráulico (tzc) e à taxa de aplicação superficial (TASzc), na zona de contato, na eficiência de clarificação de uma unidade retangular de flotação por ar dissolvido, em escala piloto, tratando água para abastecimento. Foram estudadas duas configurações da Unidade Piloto de Flotação por Ar Dissolvido (UPFAD) (A e B), as quais diferem no comprimento da zona de contato A (90 mm) e B (140 mm). A TASzc - A (133 ± 3 m/h) e B (86 ± 1 m/h) - e o tzc - A (54 ± 1s) e B (84 ± 1 s) - são diferentes. Foram avaliados três valores do Gzc A (1,8; 6,5;10,2) e B (0,9; 4,7; 6,3), através da inserção de telas com características diferentes no interior da zona de contato. E, Para cada valor de Gzc, foram investigados três valores de A/V (3,73; 4,90; 6,41). Em todos os ensaios realizados, foram fixados os seguintes parâmetros: vazão da água bruta preparada (5,4 m³/h); temperatura da água bruta preparada (26 ± 1ºC); pH de coagulação (6,5 ± 0,1); tempo de floculação (17,2 min); gradiente médio de velocidade de floculação (110 s-1); vazão de descarte após a floculação (0,8 m³/h); vazão de entrada para a flotação (Qe) (4,6 m³/h); velocidade de entrada para a flotação (ve) (180 m/h); velocidade cross-flow (45 m/h); TASzs (14,6 ± 0,2 m/h); pressão de saturação (4,5 ± 0,1 Kgf/cm²). A unidade piloto FAD foi alimentada com água preparada, que apresentou turbidez em torno de 7,4 ± 0,6 UNT, e cor aparente, em torno de 39,4 ± 4,3 UH. A fração removida dos parâmetros analisados para cada Gzc é menos sensível a variações de A/V na configuração A que na configuração B. Na configuração A, a tela que apresentou Gzc em torno de 6,5 s-1 gerou melhores resultados para cada A/V analisado. Na configuração B, a tela que gerou Gzc em torno de 4,7 s-1 proporcionou melhor fração removida de turbidez e cor para cada A/V estudado. Além disso, na configuração B, a fração removida de turbidez e cor foi menos sensível a variações de A/V, para Gzc de 4,7 s-1 que para os demais valores de Gzc. A tela que gerou resultados mais eficientes na configuração A foi a mesma para a configuração B. Portanto o uso da referida tela favoreceu o desempenho das configurações A e B. Comparando todas as situações estudadas nas duas configurações, o ensaio com a configuração A (com tzc de 54 s) com Gzc de 6,3 s-1 e A/V de 4,9 g/m³, apresentou as maiores frações de remoção de cor e turbidez. / The present work aimed to study the influence of velocity gradient (Gzc) associated with the hydraulic detention time (tzc) and the rate of surface application (TASzc) in the contact zone in the efficiency of clarification of a unit rectangular dissolved air flotation pilot scale, treating water supplies. Two different kinds of configurations of the reactor dissolved air flotation in pilot scale (UPFA) (A and B) were studied, which differ in the length of the contact zone - A (90 mm) and B (140 mm). The TASzc - A (133 ± 3 m/h) and B (86 ± 1 m/h) - and tzc - A (54 ± 1 s) and B (84 ± 1 s) were different. Three different values of Gzc were analysed - A (1.8, 6.5, 10.2 s-1) and B (0.9, 4.7, 6.3 s-1) by insertion of grilles with different characteristics within the zone contact. And for each value of Gzc, three values of A/V (3.73, 4.90, 6.41 g/m³) were investigated. In all trials, the following parameters were set: flow of synthetic raw water (5.4 m³/h), synthetic raw water temperature (26 ± 1ºC), coagulation pH (6.5 ± 0.1); flocculation time (17.2 minutes), the speed gradient flocculation (110 s-1); flow disposal after flocculation (0.8 m³/h), input flow to the flotation (Qe) (4, 6 m³/h), input speed for flotation (ve) (180 m/h), cross-flow velocity (45 m/h), TASzs (14.6 ± 0.2 m/h), saturation pressure (4.5 ± 0.1 kgf/cm ²). The pilot plant was fed with synthetic water, which showed turbidity of approximately 7.4 ± 0.6 NTU, and apparent color, about 39.4 ± 4.3 HU. The removal efficiency of the analyzed parameters for each Gzc is less sensitive to variations in the A/V in the configuration A than in the configuration B. In configuration A, the grille that showed Gzc about 6.5 s-1 gave better results for each A/V analysis. In configuration B, the grille that has generated Gzc around 4.7 s-1 provided the best removal efficiency of turbidity and color for each A/V studied. Furthermore, in the configuration B, the removal efficiency of color and turbidity was less sensitive to variations in A/V for Gzc 4.7 s-1 than for other values of Gzc. The grille that generated the best results in the configuration A was the same for the configuration B. Therefore the use of that grille favored the performance of configurations A and B. Comparing all the situations studied in two configurations, the test with the configuration A (with tzc the 54 s) with Gzc of 6.3 s-1 and A/V of 4.9 g/m³, had the highest removal efficiencies of color and turbidity.
4

Influência do gradiente médio de velocidade na zona de contato na eficiência de clarificação de água para abastecimento por flotação / Influence of the velocity gradient in the contact zone in the efficiency of clarification of potable water by flotation

Irene Monteiro da Franca Souza 13 September 2012 (has links)
O presente trabalho teve como objetivo estudar a influência do gradiente médio de velocidade (Gzc), associado ao tempo de detenção hidráulico (tzc) e à taxa de aplicação superficial (TASzc), na zona de contato, na eficiência de clarificação de uma unidade retangular de flotação por ar dissolvido, em escala piloto, tratando água para abastecimento. Foram estudadas duas configurações da Unidade Piloto de Flotação por Ar Dissolvido (UPFAD) (A e B), as quais diferem no comprimento da zona de contato A (90 mm) e B (140 mm). A TASzc - A (133 ± 3 m/h) e B (86 ± 1 m/h) - e o tzc - A (54 ± 1s) e B (84 ± 1 s) - são diferentes. Foram avaliados três valores do Gzc A (1,8; 6,5;10,2) e B (0,9; 4,7; 6,3), através da inserção de telas com características diferentes no interior da zona de contato. E, Para cada valor de Gzc, foram investigados três valores de A/V (3,73; 4,90; 6,41). Em todos os ensaios realizados, foram fixados os seguintes parâmetros: vazão da água bruta preparada (5,4 m³/h); temperatura da água bruta preparada (26 ± 1ºC); pH de coagulação (6,5 ± 0,1); tempo de floculação (17,2 min); gradiente médio de velocidade de floculação (110 s-1); vazão de descarte após a floculação (0,8 m³/h); vazão de entrada para a flotação (Qe) (4,6 m³/h); velocidade de entrada para a flotação (ve) (180 m/h); velocidade cross-flow (45 m/h); TASzs (14,6 ± 0,2 m/h); pressão de saturação (4,5 ± 0,1 Kgf/cm²). A unidade piloto FAD foi alimentada com água preparada, que apresentou turbidez em torno de 7,4 ± 0,6 UNT, e cor aparente, em torno de 39,4 ± 4,3 UH. A fração removida dos parâmetros analisados para cada Gzc é menos sensível a variações de A/V na configuração A que na configuração B. Na configuração A, a tela que apresentou Gzc em torno de 6,5 s-1 gerou melhores resultados para cada A/V analisado. Na configuração B, a tela que gerou Gzc em torno de 4,7 s-1 proporcionou melhor fração removida de turbidez e cor para cada A/V estudado. Além disso, na configuração B, a fração removida de turbidez e cor foi menos sensível a variações de A/V, para Gzc de 4,7 s-1 que para os demais valores de Gzc. A tela que gerou resultados mais eficientes na configuração A foi a mesma para a configuração B. Portanto o uso da referida tela favoreceu o desempenho das configurações A e B. Comparando todas as situações estudadas nas duas configurações, o ensaio com a configuração A (com tzc de 54 s) com Gzc de 6,3 s-1 e A/V de 4,9 g/m³, apresentou as maiores frações de remoção de cor e turbidez. / The present work aimed to study the influence of velocity gradient (Gzc) associated with the hydraulic detention time (tzc) and the rate of surface application (TASzc) in the contact zone in the efficiency of clarification of a unit rectangular dissolved air flotation pilot scale, treating water supplies. Two different kinds of configurations of the reactor dissolved air flotation in pilot scale (UPFA) (A and B) were studied, which differ in the length of the contact zone - A (90 mm) and B (140 mm). The TASzc - A (133 ± 3 m/h) and B (86 ± 1 m/h) - and tzc - A (54 ± 1 s) and B (84 ± 1 s) were different. Three different values of Gzc were analysed - A (1.8, 6.5, 10.2 s-1) and B (0.9, 4.7, 6.3 s-1) by insertion of grilles with different characteristics within the zone contact. And for each value of Gzc, three values of A/V (3.73, 4.90, 6.41 g/m³) were investigated. In all trials, the following parameters were set: flow of synthetic raw water (5.4 m³/h), synthetic raw water temperature (26 ± 1ºC), coagulation pH (6.5 ± 0.1); flocculation time (17.2 minutes), the speed gradient flocculation (110 s-1); flow disposal after flocculation (0.8 m³/h), input flow to the flotation (Qe) (4, 6 m³/h), input speed for flotation (ve) (180 m/h), cross-flow velocity (45 m/h), TASzs (14.6 ± 0.2 m/h), saturation pressure (4.5 ± 0.1 kgf/cm ²). The pilot plant was fed with synthetic water, which showed turbidity of approximately 7.4 ± 0.6 NTU, and apparent color, about 39.4 ± 4.3 HU. The removal efficiency of the analyzed parameters for each Gzc is less sensitive to variations in the A/V in the configuration A than in the configuration B. In configuration A, the grille that showed Gzc about 6.5 s-1 gave better results for each A/V analysis. In configuration B, the grille that has generated Gzc around 4.7 s-1 provided the best removal efficiency of turbidity and color for each A/V studied. Furthermore, in the configuration B, the removal efficiency of color and turbidity was less sensitive to variations in A/V for Gzc 4.7 s-1 than for other values of Gzc. The grille that generated the best results in the configuration A was the same for the configuration B. Therefore the use of that grille favored the performance of configurations A and B. Comparing all the situations studied in two configurations, the test with the configuration A (with tzc the 54 s) with Gzc of 6.3 s-1 and A/V of 4.9 g/m³, had the highest removal efficiencies of color and turbidity.

Page generated in 0.0641 seconds