• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 210
  • 10
  • 10
  • 10
  • 10
  • 9
  • 7
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 220
  • 210
  • 117
  • 105
  • 89
  • 68
  • 45
  • 33
  • 28
  • 25
  • 24
  • 23
  • 23
  • 20
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Análise termodinâmica e físico-química de duas resinas acrílicas termopolimerizadas em água aquecida e por microondas / Analysis of the thermodynamic, physical and chemistry behavior of two acrylic resins thermal polymerized by water bath and microwave.

José Henrique Bachiega Martins 09 February 2004 (has links)
O comportamento termodinâmico, assim como as propriedades físicas e químicas da resina acrílica, podem ser diferentes quando termopolimerizadas por diferentes métodos, podendo ser analisado através do monitoramento da temperatura em função do tempo de termopolimerização, do grau de porosidade, dureza Knoop (0,015 Kg) e quantidade de monômero residual. No presente trabalho foram avaliados o comportamento termodinâmico e algumas propriedades físicas e químicas de duas resinas acrílicas, termopolimerizadas em água aquecida e por energia de microondas. As resinas acrílicas Clássico e Onda Cryl foram termopolimerizadas em água aquecida pelo método clássico de Tuckfield, Worner e Guerin64 em 1943 (TWG) e através da energia de microondas a 520 W – 10 minutos, segundo Nishi44 em 1968 (MW). A temperatura da termopolimerização em função do tempo foi monitorada por termopares de cobre / constantan conectados a aparelhos eletrônicos e computacionais. Os termopares foram instalados dentro da massa de resina acrílica, da água e do revestimento de gesso. Os 22 espécimes de resina acrílica, medindo 65 / 49 / 5 mm, foram analisados sobre o grau de porosidade, dureza Knoop e quantidade de monômero residual. Os resultados foram submetidos a análise estatística através dos testes Mann – Whitney e “t” de Student. Houve diferença significante na temperatura máxima das termopolimerizações TWG e MW, na incidência de porosidade e na quantidade de monômero residual, já a dureza Knoop não apresentou diferença significante. A resina acrílica quando termopolimerizada pelas microondas sofreu um rápido aquecimento, alcançando temperaturas de 155o C, com alta incidência de porosidade, enquanto na termopolimerização em água aquecida, a temperatura máxima foi de 101,2o C, com isenção de porosidade. A maior quantidade de monômero residual foi detectada nos espécimes termopolimerizados pelo método MW. O comportamento termodinâmico da resina acrílica no método MW foi inadequado, caracterizado pela alta incidência de porosidade, menor dureza Knoop e maior quantidade de monômero residual. / Acrylic resins of the methyl methacrylate present unsuitable thermodynamic behavior during thermal polymerization mainly if the temperature exceed boiling point (100.8o C), what brings about an increase to the degree of porosity. The thermodynamic study was carried out with acrylic resins Clássico and Onda Cryl, thermal polymerized by water bath (3 hours, Tuckfield, Worner and Guerin in 1943) and by microwave (520 W – 10 minutes, Nishi in 1968). The temperature of the thermal polymerization was recorded by thermocouples (copper / constantan) and monitored by electric - electronically equipment and computers. The 2.0 mm spherical thermocouples were placed into acrylic resin and gypsium investment and the thermal polymerization was monitored. Twenty-two specimens (65 / 49 / 5 mm) were obtained after finishing and polishing and the degree of porosity was analyzed stabilizing temperature parameters in thermal polymerizations. Was analysis to hardness Knoop, by hardness machine Testor (Otto Wolpert – Werke) and residual monomer was analysis in the spectrophotometer U.V. (Ultrospect 2000 U.V. Pharmacia – Biotech). Statistical analysis was performed using Mann - Whitney and “t” Student tests. Significant difference was observed in the degree of porosity. residual monomer and maximum temperature between thermal microwave polymerization and polymerization by water bath. The microwave thermal polymerized acrylic resin quickly heated to 155o C and showed high incidence of porosity, whereas in thermal polymerization by water bath the maximum temperature reached 101.2o C and specimens were porosity free. According to the power and time used in the present study, the thermal polymerization by microwave irradiation showed unsuitable thermodynamic behavior, characterized by high incidence of porosity, least hardness and greater amount residual monomer.
22

Compositos de resina ester vinilica e aditivos a base de silicona

Mazali, Cristiana Aparecida Ittner 03 August 2018 (has links)
Orientador: Maria Isabel Felisberti / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-03T14:34:04Z (GMT). No. of bitstreams: 1 Mazali_CristianaAparecidaIttner_D.pdf: 5967892 bytes, checksum: 47ad046293774ee6c836d5678de8b5f1 (MD5) Previous issue date: 2003 / Doutorado
23

Inclinação dental em protese total em função de diferentes tecnicas de inclusão

Sousa, Rodrigo Luiz dos Santos 16 August 2004 (has links)
Orientador: Celia Marisa Rizzatti-Barbosa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:43:59Z (GMT). No. of bitstreams: 1 Sousa_RodrigoLuizdosSantos_D.pdf: 5394210 bytes, checksum: 6cc0e505d12e21be6af73e2699dad266 (MD5) Previous issue date: 2004 / Resumo: Este trabalho comparou a alteração da inclinação de primeiros molares de próteses totais obtidas pela utilização da mufla bimaxilar, com a de próteses totais obtidas em mufla monomaxilar, polimerizadas por energia de microondas (20 minutos a 20% de potência, mais 5 minutos a 60% de potência), e divididas aleatoriamente em 4 grupos, incluídos através dos seguintes protocolos: grupo 1 ¿ mufla monomaxilar e inclusão com gesso; grupo 2 ¿ mufla bimaxilar e muralha de silicone; grupo 3 - mufla bimaxilar e inclusão com gesso; grupo 4 ¿ mufla bimaxilar e muralha de silicone associada à retenção na face vestibular dos dentes. Foram confeccionados 40 pares de modelos em gesso tipo III, e sobre eles, obtidas matrizes de prótese total superior e inferior, a partir de dispositivos duplicadores e divididos em 4 grupos. Em seguida, foi confeccionada uma canaleta paralela à inclinação da vertente triturante da cúspide mésio-vestibular nos primeiros molares superiores e outra pararela à inclinação da vertente triturante da cúspide disto-vestibular para os inferiores. Em cada extremidade das canaletas foram determinados pontos referenciais com segmentos de alfinete. Em seguida, foram determinados os catetos de um triângulo imaginário, passando pelos pontos referenciais, com auxílio de um microscópio linear Olympus (0,0005 mm). Posteriormente, foi aplicado o teorema de Pitágoras e a fórmula do cosseno para determinação do ângulo de inclinação dos dentes antes e após o processamento das próteses. Os dados foram submetidos aos testes de correlação entre ângulos e de Kruskal-Wallis (5%). Não houve correlação entre os ângulos do lado direito e esquerdo de uma mesma prótese, como também entre ângulos os superior e inferior para os pares de prótese de todos os grupos estudados. Para o ângulo direito superior houve diferença estatística significante (p<0,05) entre os períodos antes e depois dos tratamentos para o grupo I (antes ¿ 39,64° e depois ¿ 40,79°), grupo II (antes ¿ 38,20° e depois ¿ 39,66°), grupo III (antes ¿ 39,14° e depois ¿ 40,12°), mas não houve diferença estatística significativa (p<0,05) entre os períodos antes e depois para o grupo IV (antes ¿ 39,49° e depois ¿ 40,73°). Para o ângulo direito inferior houve diferença estatística significante (p<0,05) entre os períodos antes e depois de aplicados os tratamentos para o grupo II (antes ¿ 37,92° e depois ¿ 38,47°) e grupo IV (antes ¿ 39,54° e depois ¿ 40,22°), mas não houve diferença estatística significativa (p<0,05) entre os períodos antes e depois para o grupo I (antes ¿ 38,11° e depois ¿ 38,22°) e grupo III (antes ¿ 39,46° e depois ¿ 39,60°). Para o ângulo esquerdo superior houve diferença estatística significativa (p<0,05) entre os períodos antes e depois de aplicados os tratamentos para o grupo I (antes ¿ 38,89° e depois ¿ 39,95°), grupo II (antes ¿ 39,47° e depois ¿ 40,26°), grupo III (antes ¿ 38,45° e depois ¿ 40,11°) e grupo IV (antes ¿ 41,98° e depois ¿ 43,04°). Para o ângulo esquerdo inferior houve diferença estatística significativa (p<0,05) entre os períodos antes e depois de aplicados os tratamentos para o grupo III (antes ¿ 40,35° e depois ¿ 39,81°) e grupo IV (antes ¿ 39,82° e depois ¿ 40,25°), mas não houve diferença estatística significativa (p<0,05) entre os períodos antes e depois para o grupo I (antes ¿ 39,57° e depois ¿ 40,34°) e grupo II (antes ¿ 38,84° e depois ¿ 39,69°). As médias de todos os ângulos estudados, não apresentaram diferença estatística significativa (p<0,05) entre si para os grupos I, II, III e IV, antes e depois de aplicados os tratamentos. Diante do exposto, foi possível concluir que as alterações de inclinação observadas estabeleceram similaridade para os tipos de muflas e de materiais de inclusão / Abstract: The purpose of this study was to evaluate first molar inclination in maxillary and mandibular complete dentures processed in monomaxilary and bimaxillary flasks by microwave irradiation (at 20 % power for 20 minutes and 60% power for 5 minutes). Forty pairs of type-III-stone models were obtained, and complete dentures were waxed and standardized with a special appliance. Dentures were divided in four groups, according to flasking and processing procedures: group 1 ¿ flasking with stone in monomaxillary flasks; group 2 ¿ flasking with silicone rubber and stone in bimaxillary flasks; group 3 --¿ flasking with stone in bimaxillary flasks; group 4 ¿ acrylic resin retentions were confectioned on buccal tooth surfaces, and flasking were taken with silicone rubber in bimaxillary flasks. For each tooth, two reference points were determined (in mesiopalatine and distobuccal cusps for maxillary first molars and in mesiobuccal and distolingual cusps for mandibular first molars). A linear comparator microscope (Olympus, 0.0005 mm tolerance) was used to measure the distance between two reference points, determining a triangle side. Using Pitagora¿s Theorem and Cossen Law, tooth inclination angles were calculated. Data were submitted to Correlation test and Kruskal-Wallis (5% significance). There was no correlation between right and left side angles and no correlation between maxillary and mandibular angles for all groups. For maxillary right angle, there were significant statistical differences (p<0.05) before and after processing among groups I (39.64° and 40.79°, respectivelly), II (38.20° and 39.66°) and III (39.14° and 40.12°). However, for group IV, there was no significant statistical difference (p>0.05) before and after processing (39.49° and 40.73°). For mandibular right angle, there were significant statistical differences (p<0.05) before and after processing between groups II (37.92° and 38.47°) and IV (39.54° and 40.22°). However, there was no significant statistical difference (p>0.05) between groups I (38.11° and 38.22°) and III (39.46° and 39.60°). For maxillary left angle, there were significant statistical differences (p<0.05) before and after processing among groups I (38.89° and 39.95°), II (39.47° and 40.26°), III (38.45° and 40.11°) and IV (41.98° and 43.04°). For mandibular left angle, there were significant statistical differences (p<0.05) between groups III (40.35° and 39.81°) and IV (39.82° and 40.25°). However, there was no significant statistical difference (p>0.05) before and after processing between groups I (39.57° and 40.34°), and II (38.84° and 39.69°). Regarding angle mean values, there was no significant statistical difference (p<0.05) before and after processing for all groups. It could be concluded that alterations observed in tooth inclination were similar for all flasking and processing procedures / Doutorado / Protese Dental / Doutor em Clínica Odontológica
24

Efeito da desinfecção química sobre a microdureza e rugosidade superficial de resinas para base de dentaduras e resinas rígidas para reebasamento: estudo longitudinal / Effect of chemical disinfection on the hardness and roughness of denture base resins and hard chairside resins: a longitudinal study

Pinto, Luciana de Rezende 20 April 2007 (has links)
O objetivo deste estudo foi investigar, longitudinalmente, o efeito de cinco soluções desinfetantes sobre a microdureza e rugosidade superficial de uma resina acrílica termopolimerizável e três materiais reembasadores rígidos. Um total de 240 corpos de prova circulares (30 X 6mm) foram fabricados, utilizando um material para base de dentaduras (Lucitone 550; n=60), e três materiais rígidos, para reembasamento (Jet; n=60, Kooliner; n=60, Tokuyama rebase II fast; n=60), os quais foram imersos em água (controle), e em cinco soluções desinfetantes (hipoclorito de sódio a 1%, hipoclorito de sódio a 2%, hipoclorito de sódio a 5,25%, glutaraldeído a 2% e gluconato de clorexidina a 4%), e testados para avaliação de microdureza Knoop (KHN) e rugosidade superficial (Ra-µm) em diferentes intervalos (antes das imersões, após 30, 90 e 180 ciclos de desinfecção. Em cada condição experimental foram utilizados 10 corpos de prova de cada material estudado. Os dados foram analisados através de esquema fatorial (6X4) e as médias foram analisadas por meio de análise de variância, seguida por teste de Tukey a 5%. Para as resinas Lucitone 550 (20,61 ± 1,36 a 15,44 ± 1,26 KHN), Jet (18,74 ± 0,47 a 13,75 ± 0,95 KNH), Kooliner (14,09 ± 1,63 a 7,52 ± 0,88 KHN) e Tokuyama rebase II fast (12,57 ± 0,94 a 8,28 ± 0,39 KHN), foi observada uma diminuição significativa dos valores de microdureza, independente da solução utilizada, após 180 ciclos de imersão. Não foi observada interação significativa para a rugosidade da resina Kooliner. Para a resina Lucitone 550 (0,06 ± 0,01 a 0,20 ± 0,02µm) e Jet (0,07 ± 0,01 a 0,23 ± 0,04µm), foi observado aumento significativo dos valores de rugosidade superficial, independente da solução desinfetante utilizada, e a após 180 ciclos de imersão em água, estes materiais mantiveram valores semelhantes ao da avaliação inicial. A resina Tokuyama rebase II fast não mostrou diferenças significativas nos valores de rugosidade superficial quando imersa em água, hipoclorito de sódio a 2%, 5,25% e glutaraldeído a 2%, durante o período do estudo. Ao final da avaliação (180 ciclos), conclui-se que, embora todas as soluções tenham causado redução da microdureza da resina Lucitone 550, os espécimes submetidos às imersões em H5,25% e H2% apresentaram menores valores, no entanto, não ocorreu diferença significante entre os desinfetantes para as resinas autopolimerizáveis. As soluções H1%, H2% e GC4% causaram maior alteração na rugosidade superficial da resina Lucitone 550. Estas mesmas soluções, além de H5,25%, promoveram maior rugosidade na resina Jet, enquanto que, para a resina Tokuyama Rebase II fast, não houve diferença entre os desinfetantes. / The aim of this study was to investigate the longitudinal effect of five disinfection solutions on the hardness and roughness of one heat-polymerizing denture base acrylic resin and three hard chairside resins. A total of 240 circular specimens (30 X 6mm) were fabricated using one denture base material (Lucitone 550; n=60) and three hard chairside reliners (Jet; n=60, Kooliner; n=60, Tokuyama rebase II fast; n=60), which were immersed in water (control), and five disinfecting solutions (1% sodium hypochlorite; 2% sodium hypochlorite; 5,25% sodium hypochlorite, 2% glutaraldehyde; 4% chlorhexidine gluconate) that were tested for knoop hardness (KHN) and roughness (Ra-µm) for different times (before immersions, after 30, 90 and 180 immersion cycles). For each experimental condition, 10 specimens were used from each material. Data was analyzed by factorial scheme (6 X 4) and the means were analyzed by The Variance Analysis which was followed by Tukey\'s test 5%. For Lucitone 550 (from 20,61 ± 1,36 to 15,44 ± 1,26 KHN), Jet (from 18,74 ± 0,47 to 13,75 ± 0,95 KHN), Kooliner (from 14,09 ± 1,63 to 7,52 ± 0,88 KHN), Tokuyama rebase II fast (from 12,57 ± 0,94 to 8,28 ± 0,39 KHN) significant decrease in hardness was observed regardless of the solution used, after 180 immersion cycles. No significant interactions were observed for Kooliner roughness. Between Lucitone (from 0,06 ± 0,01 to 0,20 ± 0,02µm) and Jet, (from 0,07 ± 0,01 to 0,23 ± 0,04µm) there was a significant increase in roughness regardless of the disinfectant solution used; Jet showed significant increase in roughness after immersion in water for 180 cycles. Tokuyama rebase II fast showed no significant differences in roughness when immersed in water, 2% sodium hypochlorite, 5.25% sodium hypochlorite, and 2% glutaraldehyde after 180 cycles. In conclusion, this study showed that Lucitone 550 specimens exhibited significant decrease in hardness regardless of the disinfection solution used, and the specimens immersed in H5,25% and H2% showed lower hardness values; However, no significant differences were noted between all disinfectants solution, for hard chairside resins. The solutions H1%, H2% and GC4% caused more alteration in roughness of Lucitone 550. These solutions along with H5,25% caused an increase in the roughness of Jet, while with the Tokuyama rebase II fast there was no difference between the disinfection solutions.
25

Efeito de sucessivos ciclos de desinfecção por microondas sobre a microdureza e rugosidade superficial de diferentes bases de próteses totais: estudo longitudinal / Effect of successive microwave disinfection cycles on the hardness and roughness of different denture base resins: a longitudinal study

Távora, Flora Freitas Fernandes 22 June 2007 (has links)
O objetivo desse estudo foi investigar longitudinalmente, o efeito de sucessivos ciclos de desinfecção sobre as propriedades de microdureza e rugosidade superficial de 4 diferentes resinas acrílicas. Foram confeccionados 200 corpos de prova, utilizando um material para base de dentaduras (Lucitone 550) e três materiais rígidos para reembasamento (Jet, Kooliner e Tokuyama Rebase II Fast), os quais foram divididos, para cada resina, em cinco grupos: imersos em água (controle) e submetidos à irradiação por microondas em quatro combinações diferentes de potência-tempo. Esses grupos foram avaliados em relação à rugosidade superficial (Ra-µm) e microdureza Knoop (KHN) em um período anterior às desinfecções e após 30, 90 e 180 ciclos de desinfecção. Os dados foram submetidos à análise de variância, seguida por teste de Tukey a 5%. As principais alterações nos valores de microdureza (diminuição) e rugosidade superficial (aumento) ocorreram após 30 ciclos de desinfecção em microondas. Após esse período existiu uma tendência para a estabilização dos valores dessas propriedades, mesmo quando ciclos adicionais (90 e 180 ciclos) foram realizados. Os tratamentos empregados para os diferentes grupos experimentais (diferentes combinações de potência-tempo) não foram os principais fatores que tiveram influência sobre a propriedade de microdureza. É provável que a redução dos valores de microdureza tenha sido mais dependente da sorpção de água do que da energia de microondas por si só. O principal efeito sobre a microdureza através da irradiação por microondas parece ser o efeito da água. A exposição da prótese a fluidos como água e saliva é uma condição que não pode ser evitada. Esse comportamento não foi observado para a rugosidade superficial. Os tratamentos empregados para os diferentes grupos experimentais (diferentes combinações de potência-tempo) tiveram influência sobre a propriedade de rugosidade superficial. De maneira geral observou-se que os valores de rugosidade superficial dos espécimes somente imersos em água foram menores do que os valores dos espécimes irradiados. Apesar da rugosidade de alguns espécimes ter ficado acima de 0.2 um, isso não parece contra-indicar a desinfecção por microondas. As técnicas convencionais de acabamento e polimento aplicadas para as outras superfícies dificilmente atingem níveis de rugosidade superficial inferiores a 0,2 µm. Dessa maneira parece ser prudente a afirmação de que a desinfecção através da energia de microondas pode ser utilizada para a desinfecção de próteses. / The objective of this study was to investigate the longitudinal effect of microwave disinfection on the hardness and roughness of one heat-polymerizing denture base acrylic resin and three hard chairside resins. A total of 200 specimens were fabricated using one denture base material (Lucitone 550; n=50) and three hard chairside reliners (Jet; n=50, Kooliner; n=50, Tokuyama Rebase II Fast; n=50), which were immersed in water (control), and submitted to microwave disinfection at four different arrangements of power and time. These specimens were tested for knoop hardness (KHN) and roughness (Ra-µm) for different times (before disinfection, after 30, 90 and 180 disinfection cycles). Data were analyzed by Variance Analysis which was followed by the Turkey\'s test at a level of 5%. The principal alterations on hardness (reduction) and on roughness (elevation) occurred after 30 disinfection cycles. Both of the properties remained stable after this period, even after 90 and 180 disinfection cycles. The different arrangements of power and time carried out for the experimental groups did not have influence on hardness. It is possible that this property was more affected from water sorption than microwave energy only. During its clinical use, the denture is exposed to water and saliva and it seems that this condition cannot be prevented. This fact was not observed for roughness. The different arrangements of power and time carried out for the experimental groups had influence on roughness. It was observed that the control group had lower roughness values when compared to the experimental groups. The roughness values of some specimens were greater than 0.2 um. However, this fact does not compromise the indication of microwave disinfection. The finishing and polishing techniques commonly used for the other surfaces of the denture do not get roughness values below 0.2 um. Therefore, it is very likely that microwave disinfection could be recommended for the disinfection of dentures.
26

Efeito de reembasamento, ciclagem mecânica e armazenagem em água sobre a resistência flexural de uma resina acrílica para base de prótese /

Reis, José Mauricio dos Santos Nunes. January 2005 (has links)
Orientador: Carlos Eduardo Vergani / Banca: Marco Antonio Compagnoni / Banca: Marcelo Ferraz Mesquita / Resumo: Este estudo avaliou o efeito do reembasamento da ciclagem mecânica e da armazenagem em água sobre a resistência à flexão de uma resina acrílica para base de prótese (Lucitone 550- L). Os corpos-de-prova foram confeccionados a partir da confecção de lâminas da resina L (64x10x2 mm3), reembasadas (1,3 mm) com quatro reembasadores quimicamente ativados (Kooliner-K, Ufi Gel Hard-UGH, Tokuso Rebase Fast-TR e New Truliner-NT). Além disso, foram confeccionados corpos-de-prova a partir do reembasamento com a própria resina L e corpos-de-prova intactos da resina L. Quarenta corpos-de-prova (64x10x3,3 mm3) foram confeccionados para cada combinação entre os materiais e divididos em quatro grupos (n=10). Os corpos-de-prova foram submetidos aos testes de flexão nas seguintes condições: após polimerização (G1); após armazenagem em água destilada a 37+-1ºC por 30 dias (G2); após ciclagem mecânica flexural de 10.000 ciclos com frequência de 5Hz (G3) e após armazenagem em água a 37ºC por 30 dias, seguida de ciclagem mecânica (G4). Os testes de flexão em três pontos foram realizados em máquina de ensaios mecânicos (5mm/min; span=50mm). A resistência à flexão (MPa) foi calculada na força máxima de ruptura (RM) e no limite de proporcionalidade (RP). A análise de variância em três níveis e o teste de Tukey HSD para comparações múltiplas foram utilizados para determinar a significância estatística dos resultados obtidos (P=0,05). Houve efeito significativo para os fatores Material e Ciclagem mecânica e para interação Armazenagem x Material. A análise dessa interação permitiu observar um aumento significante da RM das amostras L-UGH (50,64 MPa) e L-TR(57,36 MP-a), após armazenamento em água (P=0,001 e 0,016 respectivamente). Foi observado, ainda, ...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study investigated the effect of relining, cyclic loading and water storage on the flexural strength of a denture base acrylic resin (Lucitone 550-L). Specimens L were made (64x10x2 mm3) and relined (1.3 mm) with four different relining resins (Kooliner-K, Ufi Gel Hard-UGH, Tokuso Rebase Fast-TR and New Truliner-NT). In addition, specimens relined with L and intact L specimens were made. Forty specimens (64x10x3.3 mm3) were made for each material combination and divided into four groups (n=10). Specimens were submitted to the flexural strength test after: polymerization (G1); water storage in distilled water for 30 days at 37+-1ºC (G2); cyclic loading for 10000 cycles at 5 Hz (G3) and water storage in distilled water for 30 days at 37+-1ºC followed by cyclic loading (G4). For the flexural tests, force measurements were made with a testing machine at a crosshead speed of 5mm/min using a three point bending fixture with a span of 50 mm. The ultimate flexure strength (RM) and the flexural strength at the proportional limit (RP) were calculated. The results were analyzed with 3-way ANOVA and Tukey's HSD tests. After water storage, the specimens L-UGH (50.64 MPa) and L-TR (57.36 MPa) demonstrated in increased RM (P=.001 and .016, respectively). Only L-TR (24.21 MPa) demonstrated an increased RP (P=.012) after water storage. The L-L specimens produced the highest RM and RP (P=.0000), followed by intact L specimens. After water storage, L-TR demonstrated higher RM and RP than L-K, L-UGH and L-NT. The cyclic loading decreased the RM and RP of all materials (P=.031 and .0000, respectively). It has been concluded that the water storage improved the RM of L-UGH and L-TR and the RP of L-TR. The L-L specimens produced the highest values of RM and RP. The RM and RP of all materials were detrimentally influenced by cyclic loading. / Mestre
27

Efeito da variação do período do polimento na rugosidade superficial e na manutenção do polimento de diferentes resinas compostas /

Silva, João Maurício Ferraz da. January 2007 (has links)
Orientador: José Roberto Rodrigues / Banca: Eduardo Shigueyuki Uemura / Banca: George Miguel Spyrides / Resumo: O objetivo do estudo foi avaliar o efeito da realização de um polimento imediato, após 24h e após uma semana, na rugosidade superficial de duas resinas microhíbridas (Esthet - X - Dentsply e Opallis - FGM) e uma nanoparticulada (Z 350 - 3M), além de verificar a manutenção do polimento, após 1 ano, simulado por meio de termociclagem. Com auxílio de uma matriz metálica, que apresentava orifícios de 6 mm de diâmetro e 3 mm de altura, 43 cdp de cada material foram confeccionados. Em seguida foram divididos em um grupo controle e 3 grupos experimentais. Os cdp do grupo controle não receberam nenhum tipo de tratamento em suas superfícies. O grupo 1 recebeu acabamento com ponta diamantada extra-fina e posterior polimento com os sistemas Enhance e PoGo (Dentsply), imediatamente após a polimerização. O grupo 2 recebeu os mesmos procedimentos descritos para o grupo 1, porém estes foram realizados após 24 h de armazenamento em H2O destilada a 37°C. O ultimo grupo recebeu o tratamento de superfície após 7 dias de armazenamento. Após os procedimentos de acabamento e polimento os cdp tiveram a rugosidade superficial avaliada por um rugosimetro Perthometer PRK S8P (Perthen, Mahr, Germany). Feita a leitura inicial os cdp foram levadas a uma cicladora térmica e submetidos a 10.000 ciclos simulando permanência em meio oral durante o período de um ano. Após a ciclagem uma nova leitura da rugosidade foi realizada. Os resultados mostraram uma maior rugosidade para a resina Esthet - X, sendo que as resinas Opallis e Z 350 apresentaram os mesmos valores de rugosidade. Em relação ao período de realização do polimento, os cdp polidos imediatamente após a polimerização se apresentaram mais rugosos em relação aos outros dois períodos. Após a ciclagem térmica, a estatística através do teste t-pareado, mostrou que... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of the study was to evaluate the effect of a immediate polishing, after 24h and after one week, in the surface roughness of two micro-hybrid resins (Esthet - X - Dentsply and Opallis - FGM) and one nanoparticle (Z 350 - 3M), beyond verifying the maintenance of the polishing, after 1 year, simulated through thermal cycling. With aid of a metallic matrix, with orifices of 6 mm of diameter and 3 mm of height, 43 specimens of each material had been confectioned. After that they had been divided in a control group and 3 experimental groups. The specimens of the control group had received no treatment in its surfaces. Group 1 received finishing with extra-fine diamond drill and posterior polishing with the systems Enhance and PoGo (Dentsply), immediately after the polymerization. Group 2 received the same procedures described for group 1, however these had been carried out after 24 h of storage in distilled H2O 37°C. The last group received the treatment on the surface after 7 days of storage. After the procedures of finishing and burnishing the surface roughness was evaluated by a profilemeter Perthometer PRK S8P (Perthen, Mahr, Germany). After the initial reading the specimens had been taken to a thermal cycle and submitted to 10000 cycles simulating permanence in mouth on a period of one year. After the thermal cycling a new reading of the roughness was carried out. The results had shown a higher roughness for the resin Esthet - X, having the resins Opallis and Z 350 presented the same values of roughness. In relation to the period of accomplishment of polishing, specimens polished immediately after the polymerization presented higher values of roughness in relation to the other two periods. After the thermal cycling the statistics, through the test t-paired, showed that occurred maintenance of the polishing for the Opallis resin, having... (Complete abstract, click electronic access below) / Mestre
28

Análise da resistência à flexão e da microdureza de resinas acrílicas utilizadas para confecção de placas interoclusais /

Costa, Patrícia dos Santos. January 2006 (has links)
Resumo: As placas interoclusais podem ser confeccionadas por meio de várias técnicas, sendo a resina acrílica o material de escolha mais difundido atualmente. Devido ao fato de as placas serem submetidas a diferentes tipos de forças por um longoperíodo no interior da cavidade bucal, estas podem fraturar-se ou desgastar-se com facilidade. O objetivo do presente estudo foi avaliar e comparar, por meio de ensaio de resistência à flexão e teste de microdureza Knoop, o comportamento das resinas acrílicas térmica e quimicamente ativadas utilizadas na confecção de placas interoclusais, variando-se as técnicas de confecção e processamento. Para tanto, foram confeccionados 60 espécimes divididos em seis grupos (GI, GII, GIII, GIV, GV, GVI), de acordo com o tipo de resina e técnica de processamento utilizadas. Os grupos GI e GII utilizaram resina acrílica termopolimerizável convencional (Clássico), sendo o GI polimerizado em banho de água quente e o GII pela energia de microondas. Para os grupos GIII, GIV, GV e GVI, utilizou-se resina acrílica autopolimerizável (Jet) e as seguintes técnicas de processamento: GIII) polimerização em condição ambiente (23 l 2oC), GIV) sob pressão de 2kgf/cm2 e água a 40°C, GV) sob a mesma pressão e temperatura a seco e GVI) associação de placa de acetato e polimerização em água a 40°C. Após ensaio de flexão, os dados foram submetidos à análise de variância, complementada pelo teste de Tukey (a = 0,05). Para os valores de microdureza, estes foram submetidos ao teste não paramétrico de Kruskal-Wallis (a = 0,05). Verificou-se que GII e GIII apresentaram, respectivamente, os maiores e menores valores de resistência à flexão em relação aos demais grupos. GI e GII apresentaram valores semelhantes de resistência à flexão (p > 0,05). GIV, V e VI não apresentaram diferença significante entre si (p > 0,05), porém foram estatisticamente superiores ao GIII (p < 0,05). / Abstract: The occlusal splints can be fabricated by many techniques and the acrylic resin is the main material used for this propose. The splints can be easily facture or worn because they are subjected to different kinds of forces during a long period in the oral cavity. The objective of this study was to evaluate the flexural strength and Knoop microhardness of a conventional heat-polymerized and an autopolymerized acrylic resin used to fabricate occlusal splints, varying the processing laboratorial techniques. Sixty specimens were manufactured and divided in 6 groups (GI, GII, GIII, GIV, GV, GVI) according to the type of the resin and the processing technique used. GI and GII were manufactured with conventional heatpolymerized acrylic resin (Clássico). GI was hot-water-bath polymerized and GII was microwave polymerized. GIII, GIV and GV specimens were fabricated using an autopolymerized acrylic resin (Jet). GIII was polymerized in air condition (23 l 2oC), GIV under 2kgf/cm2 pressure and in water at 40°C, and GV under the same pressure and temperature at dry condition. The GVI specimens were manufactured using autopolymerized acrylic resin and acetate sheet, polymerized in water at 40°C. The resin specimens were broken using a 3-point load on a testing machine. A ANOVA and Tukey test were performed to identify significant differences (a = .05). Knoop microhardness values were analyzed with Kruskal-Wallis test (a = .05). GII and GIII showed, respectively, the highest and the lowest significantly values of strength comparing with the other groups. GI and GII, manufactured with conventional heat-polymerized acrylic resin showed similar strength (p > .05). GIV, V e VI showed similar values between them, however they were stronger than GIII (p < .05). GII showed the highest significantly values of microhardness even when compared to GI. / Orientador: Paulo Renato Junqueira Zuim / Coorientador: Débora Barros Barbosa / Banca: Alício Rosalino Garcia / Banca: Osvaldo Luiz Bezzon / Mestre
29

Resistência à fratura entre a resina acrílica e a resina composta em coroas provisórias implanto-suportadas unitárias imediatas anteriores: estudo in vitro /

Cardoso, Kátia Vieira. January 2014 (has links)
Orientador: João Neudenir Arioli Filho / Banca: Ana Carolina Pero Vizoto / Banca: Raphael Freitas de Souza / Resumo: O propósito do presente estudo foi avaliar a resistência à fratura de coroas provisórias implanto - suportadas unitárias imediatas anteriores confeccionadas com facetas de resina acrílica e resina composta após diferentes tratamentos superficiais. Para isto 64 coroas provisórias implanto-suportadas foram confeccionadas e divididas 8 grupos experimentais (n=8), de acordo com o material de confecção, resina acrílica(RA) no grupo 1 ou resina composta(RC) nos grupos 2 a 8, e, tratamentos superficiais realizados na faceta: 1- sem tratamento, 2- sem tratamento, 3- metilmetacrilato(MM), 4- primer para metal(PM), 5- sistema adesivo(SA), 6- jateamento com óxido de alumínio(Al3O2)+MM, 7- Al3O2+PM e 8- Al3O2+SA . Os espécimes foram submetidos a 1x104 ciclos térmicos variando entre duas temperaturas (5ºC e 55 ºC) e posteriormente ao ensaio de resistência à fratura, com carga aplicada com velocidade de 0,5 mm/ min até a ocorrência de falha. Quando os valores de carga máxima para fratura foram analisados, o grupo 1 (controle) obteve os maiores valores (332 N média e ± 67 desvio padrão). Comparados ao controle, os grupos 2, 3, 4, 6 e 7 se mostraram estatisticamente diferentes (P < 0.05), com valores de carga máxima para fratura inferiores ao controle. Por outro lado os grupos 5 e 8 foram semelhantes e não demonstraram diferença estatística quando comparados com o controle (P > 0.05). A partir da análise dos dados, de acordo com a metodologia utilizada, pode-se concluir que o tratamento com sistema adesivo é uma boa opção para uso clínico, aumentando a resistência das coroas provisórias implanto-suportadas confeccionadas com resina acrílica e resina composta. / Abstract: The purpose of this study was to evaluate the fracture resistance of the immediate implant-supported provisional crown prepared with denture tooth and composite resin, after different surface treatments. Sixty-four screw-retained implant-supported provisional crown were divided into 8 groups (n= 8) according to the crown material, acrylic resin(AR) group1 or composite resin(CR) groups 2 to 8 and surface treatment performed: 1- no surface treatment, and 2- no surface treatment, 3- methyl methacrylate(MM), 4- metal primer(MP), 5- bonding system(BS) 6- alumina air abrasion (Al3O2) +MM, 7- Al3O2+MP and 8- Al3O2+BS. Specimens were subjected to 1x104 thermal cycles at two temperatures (5ºC and 55 ºC) and after that was performed the static mechanical test with a crosshead speed of 0.5 mm/ min until the sample fracture. When the maximum load to failure was analyzed the group 1 (control) had the highest values (332 N ± 67 mean and standard deviation). Compared to the control, groups 2, 3, 4, 6 and 7 were statistically different (P <0.05), with lower values of maximum than the control. Moreover the 5 and 8 groups were similar and showed no statistical difference when compared with the control (p> 0.05). From the analysis of the data in accordance with the methodology used, it can be concluded that the treatment with bonding system is a good option for clinical use, increasing the resistance of implant-supported provisional crowns made with acrylic resin and composite resin. / Mestre
30

Avaliação da eficácia do ácido peracético como desinfetante de resinas acrílicas

Chassot, Ana Lucia Campani January 2001 (has links)
Para prevenir a transmissão de doenças entre pacientes e profissionais, é necessária a adoção de medidas de controle de infecção cruzada. Uma dessas medidas é a desinfecção de aparatos de resina adliça. O glutaraldeído e o hipocloito de sbdio tem sido recomendados para a desinfecção deste material, entretanto estes desinfetantes ngo são ideais para tal fim. O ácido peracetico, utilizado na Medicina para desinfeção de materiais termossensiveis, é um desinfetante eficaz e não deixa residuos tóxicos e pode ser uma alternativa. Sendo assim o objetivo deste trabalho foi avaliar a eficácia antimicrobiolbgica do ácido peracético na desinfecção de resinas acrlíicas. Foram testadas as resinas acrílicas termicamente ativada, quimicamente ativada e polimerizada em forno de microondas. As resinas foram contaminadas através do uso intraosal durante sete noites e também através do contato com microrganismos conhecidos: Bacillus subtilis e Bacillus tearothemrophilus. Os corpos de prova de resina amílica comaminada foram imersos em ácido peracético 0,2% (Sterilie®/Lifemed, São Paulo, SP) durante 5 minutos e então colocados no meio de cultura BHI (Brain Hemt lnfiszon) Após o período de incubação, a observação do crescimento bacteriano foi feita através da análise da turvação do meio de cultura. Cem por cento dos corpos de prova contaminados e colocados diretamente no meio de cultura (grupo controle) provocaram turvação do meio de cultura enquanto que nenhum dos demais corpos de prova de resina aciílica termicamente ativada, de resina acriiica quimicamente ativada e de resina acrilica polimerizada em microondas turvaram o meio, após imessão em ácido peracético por 5 minutos, comprovando a eficácia do mesmo. Concluiu-se que a imersão em ácido peracético durante 5 minutos e eficaz na desinfecção de resinas acrilicas contaminadas com Bacillus subtilis, ou com Bacillus tearothermophílzcs ou com saliva humana. Para que se estabeleça um protocolo de desinfecção de resinas acrilicas, são necessários trabalhos que provem a inércia do ácido peracético sobte as propriedades fisicas e químicas das resinas.

Page generated in 0.0548 seconds