1

Desenvolvimento de uma metodologia de calibração \"in situ \" de medidores de atividade / Development of an \"in situ\" calibration methodology to activity meters

Kuahara, Lilian Toshie 28 June 2017 (has links)
O desempenho de uma prática segura e eficiente de um serviço de medicina nuclear depende, entre outros fatores, de um programa de controle de qualidade completo, principalmente em se tratando dos instrumentos medidores de atividade dos radionuclídeos, os ativímetros. Um programa de controle de qualidade completo deve incluir a calibração de todos os instrumentos de medição utilizados no procedimento. No entanto, no Brasil, a atual norma que estabelece os requisitos de proteção radiológica para serviços de medicina nuclear (SMN), não inclui, ainda, a calibração do ativímetro. Considerando que estes instrumentos, por diversas razões, são de difícil remoção para envio a um serviço de calibração, o propósito deste trabalho foi desenvolver uma metodologia de calibração de medidores de atividades que possa ser aplicada \"in situ\", para o principal radiofármaco utilizado atualmente, o 99mTc. Foram definidos os parâmetros de influência que devem ser levados em conta durante a calibração, assim como uma logística de transporte dos radiofármacos. Um programa de controle de qualidade foi aplicado aos ativímetros do Laboratório de Calibração de Instrumento (LCI). Neste trabalho foram desenvolvidas três metodologias diferentes de calibração, considerando a logística disponível e também a origem da fonte de referência. Na primeira metodologia poderá ser aplicada nos casos em que o LCI envia uma fonte de referência ao SMN. Na segunda o SMN envia uma fonte previamente medida ao LCI que determinará sua atividade real. A terceira metodologia foi aplicada para calibração dos ativímetros pertencentes ao setor de produção de radiofármacos do IPEN. Neste caso a fonte de referência foi enviada ao LCI após uma medição prévia pelo setor de produção. Foi possível aplicar as metodologias em alguns instrumentos pertencentes a clínicas e ao setor de produção. Em todos eles foram encontrados coeficientes de calibração diferentes entre si. A maior variação encontrada foi de 5%, indicando que a medição com este ativímetro está menor em 5% do que é necessário aplicar no paciente. Verificou-se que a troca de recipientes deixa um resíduo que não tem sido considerado nas medições clínicas, podendo acrescentar uma diferença de até 3% nas medições. / The performance of a safety and efficient practice of a nuclear medicine service depends, among other factors, on a complete quality control program, especially in the case of the radionuclide activity measuring instrument, the activimeter. A complete quality control program should include the calibration of all measurement instruments used in the procedure. However, in Brazil, the actual standard that establishes the requirements of radiological protection for nuclear medicine services (NMS), does not include the calibration of the activimeter. Considering that these instruments, for various reasons, are difficult to remove for sending to a Calibration Service, the purpose of this work is to develop a methodology for activimeter calibration that can be applied \"in situ\" to the most used radiopharmaceutical, 99mTc. The parameters of influence that should be taken in into account during the calibration were defined, as well as a transport logistics of the radiopharmaceuticals. A quality control program was applied to LCI activimeters. In this study, three calibration methodologies have been established, considering the available logistics and the reference source origin. The first can be applied in cases that LCI sends the reference sample to the NMS. In the second, the NMS sends an already measured sample to the LCI that will determine its real activity. The third methodology was developed to be applied to the activimeters belonging to the radiopharmaceutical sector of IPEN. In this case, the reference source was sent to the LCI after a previous measurement by the production sector. It was possible to apply the methodologies in some instruments belonging to clinics and the production sector. In all of them, different calibration coefficients were found. The largest variation found was 5%, indicating that the measurement with this activimeter is 5% lower than that required for the patient. It was found that the exchange of containers leaves a residue that has not been considered in clinical measurements, and may add a difference of up to 3% in the measurements.
2

Desenvolvimento de uma metodologia de calibração \"in situ \" de medidores de atividade / Development of an \"in situ\" calibration methodology to activity meters

Lilian Toshie Kuahara 28 June 2017 (has links)
O desempenho de uma prática segura e eficiente de um serviço de medicina nuclear depende, entre outros fatores, de um programa de controle de qualidade completo, principalmente em se tratando dos instrumentos medidores de atividade dos radionuclídeos, os ativímetros. Um programa de controle de qualidade completo deve incluir a calibração de todos os instrumentos de medição utilizados no procedimento. No entanto, no Brasil, a atual norma que estabelece os requisitos de proteção radiológica para serviços de medicina nuclear (SMN), não inclui, ainda, a calibração do ativímetro. Considerando que estes instrumentos, por diversas razões, são de difícil remoção para envio a um serviço de calibração, o propósito deste trabalho foi desenvolver uma metodologia de calibração de medidores de atividades que possa ser aplicada \"in situ\", para o principal radiofármaco utilizado atualmente, o 99mTc. Foram definidos os parâmetros de influência que devem ser levados em conta durante a calibração, assim como uma logística de transporte dos radiofármacos. Um programa de controle de qualidade foi aplicado aos ativímetros do Laboratório de Calibração de Instrumento (LCI). Neste trabalho foram desenvolvidas três metodologias diferentes de calibração, considerando a logística disponível e também a origem da fonte de referência. Na primeira metodologia poderá ser aplicada nos casos em que o LCI envia uma fonte de referência ao SMN. Na segunda o SMN envia uma fonte previamente medida ao LCI que determinará sua atividade real. A terceira metodologia foi aplicada para calibração dos ativímetros pertencentes ao setor de produção de radiofármacos do IPEN. Neste caso a fonte de referência foi enviada ao LCI após uma medição prévia pelo setor de produção. Foi possível aplicar as metodologias em alguns instrumentos pertencentes a clínicas e ao setor de produção. Em todos eles foram encontrados coeficientes de calibração diferentes entre si. A maior variação encontrada foi de 5%, indicando que a medição com este ativímetro está menor em 5% do que é necessário aplicar no paciente. Verificou-se que a troca de recipientes deixa um resíduo que não tem sido considerado nas medições clínicas, podendo acrescentar uma diferença de até 3% nas medições. / The performance of a safety and efficient practice of a nuclear medicine service depends, among other factors, on a complete quality control program, especially in the case of the radionuclide activity measuring instrument, the activimeter. A complete quality control program should include the calibration of all measurement instruments used in the procedure. However, in Brazil, the actual standard that establishes the requirements of radiological protection for nuclear medicine services (NMS), does not include the calibration of the activimeter. Considering that these instruments, for various reasons, are difficult to remove for sending to a Calibration Service, the purpose of this work is to develop a methodology for activimeter calibration that can be applied \"in situ\" to the most used radiopharmaceutical, 99mTc. The parameters of influence that should be taken in into account during the calibration were defined, as well as a transport logistics of the radiopharmaceuticals. A quality control program was applied to LCI activimeters. In this study, three calibration methodologies have been established, considering the available logistics and the reference source origin. The first can be applied in cases that LCI sends the reference sample to the NMS. In the second, the NMS sends an already measured sample to the LCI that will determine its real activity. The third methodology was developed to be applied to the activimeters belonging to the radiopharmaceutical sector of IPEN. In this case, the reference source was sent to the LCI after a previous measurement by the production sector. It was possible to apply the methodologies in some instruments belonging to clinics and the production sector. In all of them, different calibration coefficients were found. The largest variation found was 5%, indicating that the measurement with this activimeter is 5% lower than that required for the patient. It was found that the exchange of containers leaves a residue that has not been considered in clinical measurements, and may add a difference of up to 3% in the measurements.
3

Estudo e determinação de fatores de influência das dimensões dos frascos de radiofármacos utilizados no IPEN para calibração de ativímetros / Study and determination of the influence factors of the radiopharmaceutical vials dimensions used for activimeter calibration at IPEN

Martins, Elaine Wirney 25 October 2010 (has links)
A eficiência e a segurança de uma prática de medicina nuclear dependem, entre outros fatores, de um programa de controle de qualidade, principalmente no que diz respeito à utilização de medidores de atividade de radionuclídeos (ativímetros). Dentre as maiores fontes de erro nas medidas realizadas com um ativímetro estão: a espessura, o tamanho e o volume do frasco que contém o radiofármaco, considerando que um ativímetro típico tem a sua resposta reconhecidamente dependente do frasco utilizado. O propósito desse trabalho foi implantar um programa de controle de qualidade além de estabelecer fatores de correção referente à geometria do frasco de vidro para distribuição de radiofármacos e calibração de ativímetros, considerando que o Laboratório de Calibração de Instrumentos (LCI) do Instituto de Pesquisas Energéticas e Nucleares (IPEN) possui um Sistema Padrão Secundário NPL-CRC radionuclide calibrator, fabricado pela Southern Scientific, composto por uma câmara de ionização tipo poço e um sistema de medida de corrente, com rastreabilidade ao National Physical Laboratory (NPL) e calibrado com um frasco de vidro tipo P6 que possui dimensões diferentes dos utilizados pelo IPEN. Foram testados os radiofármacos 67Ga, 131I, 201Tl e 99mTc, todos produzidos pelo IPEN. Os resultados demonstraram uma variação de até 22% para o radiofármaco 201Tl, sendo que a menor variação foi encontrada para o 131I (2,98%). Os fatores de correção encontrados devem ser incorporados na calibração rotineira dos ativímetros. / The efficiency and safety of the nuclear medicine practice depend, among others factors, of a quality control programme, mainly related to the use of the nuclide activity meters (activimeter). One of the most important sources of errors in the activimeter measurements is the thickness, size and volume of the vial that contains the radiopharmaceutical considering that a typical activimeter has its response dependent of the vial used. The objective of this work was to establish a quality control programme and the correction factors for the geometry of the vials used for distribution of radiopharmaceutical and activimeters calibration, considering that the Calibration Laboratory of Instrumentos (LCI) of the Instituto de Pesquisas Energéticas e Nucleares (IPEN) has a NPL-CRC Secondary Standard Radionuclide Calibrator System, manufactured for the Southern Scientific plc, compound by an ionization chamber well type and a current measurement system, with traceability to National Physical Laboratory (NPL) and calibrated with a P6 vial type with different dimensions of the one used for the IPEN. The radiopharmaceutical produced by IPEN 67Ga, 131I, 201Tl and 99mTc, had been tested using the two different vials. The results shown a maximum variation of 22% for 201Tl, and the minimum variation was 2.98% for 131I. The correction factors must be incorporated in the routine calibration of the activimeters.
4

Estudo e determinação de fatores de influência das dimensões dos frascos de radiofármacos utilizados no IPEN para calibração de ativímetros / Study and determination of the influence factors of the radiopharmaceutical vials dimensions used for activimeter calibration at IPEN

Elaine Wirney Martins 25 October 2010 (has links)
A eficiência e a segurança de uma prática de medicina nuclear dependem, entre outros fatores, de um programa de controle de qualidade, principalmente no que diz respeito à utilização de medidores de atividade de radionuclídeos (ativímetros). Dentre as maiores fontes de erro nas medidas realizadas com um ativímetro estão: a espessura, o tamanho e o volume do frasco que contém o radiofármaco, considerando que um ativímetro típico tem a sua resposta reconhecidamente dependente do frasco utilizado. O propósito desse trabalho foi implantar um programa de controle de qualidade além de estabelecer fatores de correção referente à geometria do frasco de vidro para distribuição de radiofármacos e calibração de ativímetros, considerando que o Laboratório de Calibração de Instrumentos (LCI) do Instituto de Pesquisas Energéticas e Nucleares (IPEN) possui um Sistema Padrão Secundário NPL-CRC radionuclide calibrator, fabricado pela Southern Scientific, composto por uma câmara de ionização tipo poço e um sistema de medida de corrente, com rastreabilidade ao National Physical Laboratory (NPL) e calibrado com um frasco de vidro tipo P6 que possui dimensões diferentes dos utilizados pelo IPEN. Foram testados os radiofármacos 67Ga, 131I, 201Tl e 99mTc, todos produzidos pelo IPEN. Os resultados demonstraram uma variação de até 22% para o radiofármaco 201Tl, sendo que a menor variação foi encontrada para o 131I (2,98%). Os fatores de correção encontrados devem ser incorporados na calibração rotineira dos ativímetros. / The efficiency and safety of the nuclear medicine practice depend, among others factors, of a quality control programme, mainly related to the use of the nuclide activity meters (activimeter). One of the most important sources of errors in the activimeter measurements is the thickness, size and volume of the vial that contains the radiopharmaceutical considering that a typical activimeter has its response dependent of the vial used. The objective of this work was to establish a quality control programme and the correction factors for the geometry of the vials used for distribution of radiopharmaceutical and activimeters calibration, considering that the Calibration Laboratory of Instrumentos (LCI) of the Instituto de Pesquisas Energéticas e Nucleares (IPEN) has a NPL-CRC Secondary Standard Radionuclide Calibrator System, manufactured for the Southern Scientific plc, compound by an ionization chamber well type and a current measurement system, with traceability to National Physical Laboratory (NPL) and calibrated with a P6 vial type with different dimensions of the one used for the IPEN. The radiopharmaceutical produced by IPEN 67Ga, 131I, 201Tl and 99mTc, had been tested using the two different vials. The results shown a maximum variation of 22% for 201Tl, and the minimum variation was 2.98% for 131I. The correction factors must be incorporated in the routine calibration of the activimeters.