• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de uma metodologia de calibração \"in situ \" de medidores de atividade / Development of an \"in situ\" calibration methodology to activity meters

Kuahara, Lilian Toshie 28 June 2017 (has links)
O desempenho de uma prática segura e eficiente de um serviço de medicina nuclear depende, entre outros fatores, de um programa de controle de qualidade completo, principalmente em se tratando dos instrumentos medidores de atividade dos radionuclídeos, os ativímetros. Um programa de controle de qualidade completo deve incluir a calibração de todos os instrumentos de medição utilizados no procedimento. No entanto, no Brasil, a atual norma que estabelece os requisitos de proteção radiológica para serviços de medicina nuclear (SMN), não inclui, ainda, a calibração do ativímetro. Considerando que estes instrumentos, por diversas razões, são de difícil remoção para envio a um serviço de calibração, o propósito deste trabalho foi desenvolver uma metodologia de calibração de medidores de atividades que possa ser aplicada \"in situ\", para o principal radiofármaco utilizado atualmente, o 99mTc. Foram definidos os parâmetros de influência que devem ser levados em conta durante a calibração, assim como uma logística de transporte dos radiofármacos. Um programa de controle de qualidade foi aplicado aos ativímetros do Laboratório de Calibração de Instrumento (LCI). Neste trabalho foram desenvolvidas três metodologias diferentes de calibração, considerando a logística disponível e também a origem da fonte de referência. Na primeira metodologia poderá ser aplicada nos casos em que o LCI envia uma fonte de referência ao SMN. Na segunda o SMN envia uma fonte previamente medida ao LCI que determinará sua atividade real. A terceira metodologia foi aplicada para calibração dos ativímetros pertencentes ao setor de produção de radiofármacos do IPEN. Neste caso a fonte de referência foi enviada ao LCI após uma medição prévia pelo setor de produção. Foi possível aplicar as metodologias em alguns instrumentos pertencentes a clínicas e ao setor de produção. Em todos eles foram encontrados coeficientes de calibração diferentes entre si. A maior variação encontrada foi de 5%, indicando que a medição com este ativímetro está menor em 5% do que é necessário aplicar no paciente. Verificou-se que a troca de recipientes deixa um resíduo que não tem sido considerado nas medições clínicas, podendo acrescentar uma diferença de até 3% nas medições. / The performance of a safety and efficient practice of a nuclear medicine service depends, among other factors, on a complete quality control program, especially in the case of the radionuclide activity measuring instrument, the activimeter. A complete quality control program should include the calibration of all measurement instruments used in the procedure. However, in Brazil, the actual standard that establishes the requirements of radiological protection for nuclear medicine services (NMS), does not include the calibration of the activimeter. Considering that these instruments, for various reasons, are difficult to remove for sending to a Calibration Service, the purpose of this work is to develop a methodology for activimeter calibration that can be applied \"in situ\" to the most used radiopharmaceutical, 99mTc. The parameters of influence that should be taken in into account during the calibration were defined, as well as a transport logistics of the radiopharmaceuticals. A quality control program was applied to LCI activimeters. In this study, three calibration methodologies have been established, considering the available logistics and the reference source origin. The first can be applied in cases that LCI sends the reference sample to the NMS. In the second, the NMS sends an already measured sample to the LCI that will determine its real activity. The third methodology was developed to be applied to the activimeters belonging to the radiopharmaceutical sector of IPEN. In this case, the reference source was sent to the LCI after a previous measurement by the production sector. It was possible to apply the methodologies in some instruments belonging to clinics and the production sector. In all of them, different calibration coefficients were found. The largest variation found was 5%, indicating that the measurement with this activimeter is 5% lower than that required for the patient. It was found that the exchange of containers leaves a residue that has not been considered in clinical measurements, and may add a difference of up to 3% in the measurements.
2

Desenvolvimento de uma metodologia de calibração \"in situ \" de medidores de atividade / Development of an \"in situ\" calibration methodology to activity meters

Lilian Toshie Kuahara 28 June 2017 (has links)
O desempenho de uma prática segura e eficiente de um serviço de medicina nuclear depende, entre outros fatores, de um programa de controle de qualidade completo, principalmente em se tratando dos instrumentos medidores de atividade dos radionuclídeos, os ativímetros. Um programa de controle de qualidade completo deve incluir a calibração de todos os instrumentos de medição utilizados no procedimento. No entanto, no Brasil, a atual norma que estabelece os requisitos de proteção radiológica para serviços de medicina nuclear (SMN), não inclui, ainda, a calibração do ativímetro. Considerando que estes instrumentos, por diversas razões, são de difícil remoção para envio a um serviço de calibração, o propósito deste trabalho foi desenvolver uma metodologia de calibração de medidores de atividades que possa ser aplicada \"in situ\", para o principal radiofármaco utilizado atualmente, o 99mTc. Foram definidos os parâmetros de influência que devem ser levados em conta durante a calibração, assim como uma logística de transporte dos radiofármacos. Um programa de controle de qualidade foi aplicado aos ativímetros do Laboratório de Calibração de Instrumento (LCI). Neste trabalho foram desenvolvidas três metodologias diferentes de calibração, considerando a logística disponível e também a origem da fonte de referência. Na primeira metodologia poderá ser aplicada nos casos em que o LCI envia uma fonte de referência ao SMN. Na segunda o SMN envia uma fonte previamente medida ao LCI que determinará sua atividade real. A terceira metodologia foi aplicada para calibração dos ativímetros pertencentes ao setor de produção de radiofármacos do IPEN. Neste caso a fonte de referência foi enviada ao LCI após uma medição prévia pelo setor de produção. Foi possível aplicar as metodologias em alguns instrumentos pertencentes a clínicas e ao setor de produção. Em todos eles foram encontrados coeficientes de calibração diferentes entre si. A maior variação encontrada foi de 5%, indicando que a medição com este ativímetro está menor em 5% do que é necessário aplicar no paciente. Verificou-se que a troca de recipientes deixa um resíduo que não tem sido considerado nas medições clínicas, podendo acrescentar uma diferença de até 3% nas medições. / The performance of a safety and efficient practice of a nuclear medicine service depends, among other factors, on a complete quality control program, especially in the case of the radionuclide activity measuring instrument, the activimeter. A complete quality control program should include the calibration of all measurement instruments used in the procedure. However, in Brazil, the actual standard that establishes the requirements of radiological protection for nuclear medicine services (NMS), does not include the calibration of the activimeter. Considering that these instruments, for various reasons, are difficult to remove for sending to a Calibration Service, the purpose of this work is to develop a methodology for activimeter calibration that can be applied \"in situ\" to the most used radiopharmaceutical, 99mTc. The parameters of influence that should be taken in into account during the calibration were defined, as well as a transport logistics of the radiopharmaceuticals. A quality control program was applied to LCI activimeters. In this study, three calibration methodologies have been established, considering the available logistics and the reference source origin. The first can be applied in cases that LCI sends the reference sample to the NMS. In the second, the NMS sends an already measured sample to the LCI that will determine its real activity. The third methodology was developed to be applied to the activimeters belonging to the radiopharmaceutical sector of IPEN. In this case, the reference source was sent to the LCI after a previous measurement by the production sector. It was possible to apply the methodologies in some instruments belonging to clinics and the production sector. In all of them, different calibration coefficients were found. The largest variation found was 5%, indicating that the measurement with this activimeter is 5% lower than that required for the patient. It was found that the exchange of containers leaves a residue that has not been considered in clinical measurements, and may add a difference of up to 3% in the measurements.
3

Desenvolvimento de metodologia para a caracterização de fontes radioativas seladas / Development of methodology for the characterization of radioactive sealed sources

Ferreira, Robson de Jesus 15 September 2010 (has links)
Fontes radioativas seladas são largamente empregadas no mundo. A Agência Internacional de Energia Atômica AIEA estima em dezenas de milhões de fontes radioativas no mundo. No Brasil, este número é próximo de 500 mil unidades, considerando-se as fontes de pára-raios e detectores de fumaça. Uma fonte selada pode tornar-se desnecessária, seja devido ao seu decaimento ou outro motivo, sendo classificada como fontes radioativas seladas fora de uso (FRS). No Brasil, a maioria das FRS é considerada rejeito radioativo e são encaminhadas a um dos institutos da CNEN. Sem uma estratégia definida para a deposição das FRS, estas são armazenadas aguardando uma solução. A Gerência de Rejeitos Radioativos - GRR do IPEN-CNEN/SP é o principal centro de recepção desse material e até meados de 2010 havia recebido cerca de 14.000 fontes. O processo proposto para a gestão dessas FRS consiste em retirá-las de suas blindagens originais e transferi-las a outra blindagem, projetada para esse fim. As operações de transferência são realizadas em uma cela quente, garantindo a segurança radiológica. Uma das exigências da CNEN é que todas as fontes seladas sejam caracterizadas. No processo estudado, a avaliação da atividade de cada fonte será feita utilizando-se um detector, do tipo câmara de ionização tipo poço. O presente trabalho tem por objetivo desenvolver uma metodologia para aferir ou determinar a atividade de FRS armazenadas na GRR de acordo com sua geometria e determinar suas incertezas. / Sealed radioactive sources are widely used in many applications of nuclear technology in industry, medicine, research and others. The International Atomic Energy Agency (IAEA) estimates tens of millions sources in the world. In Brazil, the number is about 500 thousand sources, if the Americium-241 sources present in radioactive lightning rods and smoke detectors are included in the inventory. At the end of the useful life, most sources become disused, constitute a radioactive waste, and are then termed spent sealed radioactive sources (SSRS). In Brazil, this waste is collected by the research institutes of the Nuclear Commission of Nuclear Energy and kept under centralized storage, awaiting definition of the final disposal route. The Waste Management Laboratory (WML) at the Nuclear and Energy Research Institute is the main storage center, having received until July 2010 about 14.000 disused sources, not including the tens of thousands of lightning rod and smoke detector sources. A program is underway in the WML to replacing the original shielding by a standard disposal package and to determining the radioisotope content and activity of each one. The identification of the radionuclides and the measurement of activities will be carried out with a well type ionization chamber. This work aims to develop a methodology for measuring or to determine the activity SSRS stored in the WML accordance with its geometry and determine their uncertainties.
4

Desenvolvimento de metodologia para a caracterização de fontes radioativas seladas / Development of methodology for the characterization of radioactive sealed sources

Robson de Jesus Ferreira 15 September 2010 (has links)
Fontes radioativas seladas são largamente empregadas no mundo. A Agência Internacional de Energia Atômica AIEA estima em dezenas de milhões de fontes radioativas no mundo. No Brasil, este número é próximo de 500 mil unidades, considerando-se as fontes de pára-raios e detectores de fumaça. Uma fonte selada pode tornar-se desnecessária, seja devido ao seu decaimento ou outro motivo, sendo classificada como fontes radioativas seladas fora de uso (FRS). No Brasil, a maioria das FRS é considerada rejeito radioativo e são encaminhadas a um dos institutos da CNEN. Sem uma estratégia definida para a deposição das FRS, estas são armazenadas aguardando uma solução. A Gerência de Rejeitos Radioativos - GRR do IPEN-CNEN/SP é o principal centro de recepção desse material e até meados de 2010 havia recebido cerca de 14.000 fontes. O processo proposto para a gestão dessas FRS consiste em retirá-las de suas blindagens originais e transferi-las a outra blindagem, projetada para esse fim. As operações de transferência são realizadas em uma cela quente, garantindo a segurança radiológica. Uma das exigências da CNEN é que todas as fontes seladas sejam caracterizadas. No processo estudado, a avaliação da atividade de cada fonte será feita utilizando-se um detector, do tipo câmara de ionização tipo poço. O presente trabalho tem por objetivo desenvolver uma metodologia para aferir ou determinar a atividade de FRS armazenadas na GRR de acordo com sua geometria e determinar suas incertezas. / Sealed radioactive sources are widely used in many applications of nuclear technology in industry, medicine, research and others. The International Atomic Energy Agency (IAEA) estimates tens of millions sources in the world. In Brazil, the number is about 500 thousand sources, if the Americium-241 sources present in radioactive lightning rods and smoke detectors are included in the inventory. At the end of the useful life, most sources become disused, constitute a radioactive waste, and are then termed spent sealed radioactive sources (SSRS). In Brazil, this waste is collected by the research institutes of the Nuclear Commission of Nuclear Energy and kept under centralized storage, awaiting definition of the final disposal route. The Waste Management Laboratory (WML) at the Nuclear and Energy Research Institute is the main storage center, having received until July 2010 about 14.000 disused sources, not including the tens of thousands of lightning rod and smoke detector sources. A program is underway in the WML to replacing the original shielding by a standard disposal package and to determining the radioisotope content and activity of each one. The identification of the radionuclides and the measurement of activities will be carried out with a well type ionization chamber. This work aims to develop a methodology for measuring or to determine the activity SSRS stored in the WML accordance with its geometry and determine their uncertainties.

Page generated in 0.0392 seconds