• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 2
  • Tagged with
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Development of a Transmission-type Ultra-thin ScCVD Diamond ∆E Detector for Alpha Particles

Cheng, Xingzhi January 2020 (has links)
We present an ultra-thin transmission-type radiation detector developed for counting microbeam alpha particles. The ∆E alpha detector is a single crystal chemical vapor deposited diamond (ScCVDD) and will be installed between the microbeam accelerator window and a biologic sample. The commercially available optical grade ScCVDD sample (3 mm × 3 mm × 50 µm) was etched down to a few µm thickness which allows alpha particles to penetrate, and then it was followed by the surface cleaning, electrical contact deposition and post-metallization annealing. SRIM code and MCNP6 were used for energy loss calculation of alpha particles in electrodes and diamond and pulse height spectra prediction. In order to evaluate the performance of the ultra-thin ScCVDD detector, a ∆E-E detectors system was setup using a calibration source, the ScCVD detector and a silicon surface barrier detector (SBD). The absolute and intrinsic totally efficiency were determined as 0.3 % and 16 % respectively. Alpha and gamma peaks were observed while the peak resolution is not quite promised. The transmission ability of the ScCVDD detector was verified by applying coincidence operation with 0.22 µs time window. The thickness of the ultra-thin diamond sample was reassessed to be 8.315±0.690 µm from ∆E-E spectrometery. / Thesis / Master of Science (MSc)
2

Fabrication and Characterization of Gallium Nitride Schottky Diode Devices for Determination of Electron-Hole Pair Creation Energy and Intrinsic Neutron Sensitivity

Mulligan, Padhraic Liam January 2015 (has links)
No description available.
3

"Fatores que influenciam a resolução em energia na espectrometria de partículas alfa com diodos de Si" / "Factors affecting the energy resolution in alpha particle spectrometry with silicon diodes"

Camargo, Fabio de 10 May 2005 (has links)
Neste trabalho são apresentados os estudos das condições de resposta de um diodo de Si, com estrutura de múltiplos anéis de guarda, na detecção e espectrometria de partículas alfa. Este diodo foi fabricado por meio do processo de implantação iônica (Al/p+/n/n+/Al) em um substrato de Si do tipo n com resistividade de 3 kohm•cm, 300 mícrons de espessura e área útil de 4 mm2. Para usar este diodo como detector, a face n+ deste dispositivo foi polarizada reversamente, o primeiro anel de guarda aterrado e os sinais elétricos extraídos da face p+. Estes sinais eram enviados diretamente a um pré-amplificador desenvolvido em nosso laboratório, baseado no emprego do circuito híbrido A250 da Amptek, seguido da eletrônica nuclear convencional. Os resultados obtidos com este sistema na detecção direta de partículas alfa do Am-241evidenciaram excelente estabilidade de resposta com uma elevada eficiência de detecção (= 100 %). O desempenho deste diodo na espectrometria de partículas alfa foi estudado priorizando-se a influência da tensão de polarização, do ruído eletrônico, da temperatura e da distância fonte-detector na resolução em energia. Os resultados mostraram que a maior contribuição para a deterioração deste parâmetro é devida à espessura da camada morta do diodo (1 mícron). No entanto, mesmo em temperatura ambiente, a resolução medida (FWHM = 18,8 keV) para as partículas alfa de 5485,6 keV (Am-241) é comparável àquelas obtidas com detectores convencionais de barreira de superfície freqüentemente utilizados em espectrometria destas partículas. / In this work are presented the studies about the response of a multi-structure guard rings silicon diode for detection and spectrometry of alpha particles. This ion-implanted diode (Al/p+/n/n+/Al) was processed out of 300 micrometers thick, n type substrate with a resistivity of 3 kohm•cm and an active area of 4 mm2. In order to use this diode as a detector, the bias voltage was applied on the n+ side, the first guard ring was grounded and the electrical signals were readout from the p+ side. These signals were directly sent to a tailor made preamplifier, based on the hybrid circuit A250 (Amptek), followed by a conventional nuclear electronic. The results obtained with this system for the direct detection of alpha particles from Am-241 showed an excellent response stability with a high detection efficiency (= 100 %). The performance of this diode for alpha particle spectrometry was studied and it was prioritized the influence of the polarization voltage, the electronic noise, the temperature and the source-diode distance on the energy resolution. The results showed that the major contribution for the deterioration of this parameter is due to the diode dead layer thickness (1 micrometer). However, even at room temperature, the energy resolution (FWHM = 18.8 keV) measured for the 5485.6 MeV alpha particles (Am-241) is comparable to those obtained with ordinary silicon barrier detectors frequently used for these particles spectrometry.
4

"Fatores que influenciam a resolução em energia na espectrometria de partículas alfa com diodos de Si" / "Factors affecting the energy resolution in alpha particle spectrometry with silicon diodes"

Fabio de Camargo 10 May 2005 (has links)
Neste trabalho são apresentados os estudos das condições de resposta de um diodo de Si, com estrutura de múltiplos anéis de guarda, na detecção e espectrometria de partículas alfa. Este diodo foi fabricado por meio do processo de implantação iônica (Al/p+/n/n+/Al) em um substrato de Si do tipo n com resistividade de 3 kohm•cm, 300 mícrons de espessura e área útil de 4 mm2. Para usar este diodo como detector, a face n+ deste dispositivo foi polarizada reversamente, o primeiro anel de guarda aterrado e os sinais elétricos extraídos da face p+. Estes sinais eram enviados diretamente a um pré-amplificador desenvolvido em nosso laboratório, baseado no emprego do circuito híbrido A250 da Amptek, seguido da eletrônica nuclear convencional. Os resultados obtidos com este sistema na detecção direta de partículas alfa do Am-241evidenciaram excelente estabilidade de resposta com uma elevada eficiência de detecção (= 100 %). O desempenho deste diodo na espectrometria de partículas alfa foi estudado priorizando-se a influência da tensão de polarização, do ruído eletrônico, da temperatura e da distância fonte-detector na resolução em energia. Os resultados mostraram que a maior contribuição para a deterioração deste parâmetro é devida à espessura da camada morta do diodo (1 mícron). No entanto, mesmo em temperatura ambiente, a resolução medida (FWHM = 18,8 keV) para as partículas alfa de 5485,6 keV (Am-241) é comparável àquelas obtidas com detectores convencionais de barreira de superfície freqüentemente utilizados em espectrometria destas partículas. / In this work are presented the studies about the response of a multi-structure guard rings silicon diode for detection and spectrometry of alpha particles. This ion-implanted diode (Al/p+/n/n+/Al) was processed out of 300 micrometers thick, n type substrate with a resistivity of 3 kohm•cm and an active area of 4 mm2. In order to use this diode as a detector, the bias voltage was applied on the n+ side, the first guard ring was grounded and the electrical signals were readout from the p+ side. These signals were directly sent to a tailor made preamplifier, based on the hybrid circuit A250 (Amptek), followed by a conventional nuclear electronic. The results obtained with this system for the direct detection of alpha particles from Am-241 showed an excellent response stability with a high detection efficiency (= 100 %). The performance of this diode for alpha particle spectrometry was studied and it was prioritized the influence of the polarization voltage, the electronic noise, the temperature and the source-diode distance on the energy resolution. The results showed that the major contribution for the deterioration of this parameter is due to the diode dead layer thickness (1 micrometer). However, even at room temperature, the energy resolution (FWHM = 18.8 keV) measured for the 5485.6 MeV alpha particles (Am-241) is comparable to those obtained with ordinary silicon barrier detectors frequently used for these particles spectrometry.

Page generated in 0.0802 seconds