• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 43
  • 1
  • Tagged with
  • 44
  • 44
  • 20
  • 20
  • 19
  • 19
  • 14
  • 13
  • 11
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Análise da distribuição de tensão em protocolo mandibular confeccionado pelo sistema convencional e CAD/CAM, variando tipo, número e inclinação dos implantes / Stress distribution analysis of mandibular protocol confectioned by the conventional system and cad/cam, ranging type, number and inclination of the implants

Sbardelotto, Cristian 19 January 2016 (has links)
As próteses totais fixas implantossuportadas tem ganhado cada dia mais seu espaço no tratamento reabilitador de pacientes edêntulos, pois se trata de uma forma de tratamento que atende todos os quesitos funcionais e estéticos. Ainda não existe na literatura um consenso de qual a configuração que melhor distribui as tensões aos implantes e tecidos adjacentes. O objetivo deste estudo foi comparar as tensões geradas na interface osso-implante de próteses totais mandibulares implantossuportadas através do método de correlação de imagens digitais (CID). Foram analisadas duas configurações diferentes quanto a quantidade e posicionamento de implantes (4 ou 5 implantes), diferentes conexões [hexágono externo (HE) e cone morse (CM)] e barras para prótese fixa implantossuportada obtidas por fundição convencional e usinadas pelo sistema CAD/CAM. Foram confeccionados modelos em poliuretano, utilizando implantes de 3,75x11mm, divididos em 8 grupos: G1 (5 implantes/HE/CAD-CAM), G2 (5 Implantes/CM/CAD CAM), G3 (5 Implantes/HE/Convencional), G4 (5 Implantes/CM/Convencional), G5 (4 Implantes/HE/CAD CAM), G6 (4 Implantes/CM/CAD CAM), G7 (4 Implantes/HE/Convencional) e G8 (4 Implantes/CM/Convencional). A análise por CID foi feita quantitativamente e qualitativamente, com aplicação de carga de 250N na fossa central do primeiro molar inferior, onde foram estabelecidas diferentes regiões de interesse para a análise, sendo denominadas de C1 (cervical 1) e A1 (apical 1) para região distal ao último implante, C2 (cervical 2) e A2 (apical) para região mesial ao último implante. Foram encontradas diferenças estatisticamente significantes para o número de implantes em todas as regiões analisadas [C1 (p=0,002), A1 (p=0,01), C2 (p=0,001), A2 (p=0,004)], para as conexões foram encontradas diferenças na região C2 (p<0,05) e para as barras na região A2 (p=0,003). De acordo com os resultados pode-se concluir que as prótese com 4 implantes apresentaram maior quantidade de tensões por tração nas regiões apicais, não houve diferença significativa na concentração de tensões para as conexões HE e CM, exceto para a região C2, onde houve maior concentração de tensão para conexão CM e em comparação ao método de obtenção das barras, as barras convencionais apresentaram maior concentração de tensões de tração nas próteses com 5 implantes. / The implant-supported fixed dental prostheses have been used to rehabilitate edentulous patients as it fulfills not only functional aspects but also esthetic questions. Literature shows that there is no consensus about the best configuration to distribute stress to the implants and surrounding tissues. The objective of this study was to compare the stress generated at the boneimplant interface of implant-supported mandibular dentures by a digital image correlation method (DIC). Two different configurations were analyzed for the implants quantity and position (4 or 5 implants), different connections [external hexagon (EH) and Cone Morse (CM)] and bars for implant-supported fixed prosthesis obtained by conventional casting and machined by CAD/CAM system. Models were prepared from polyurethane and implants (3.75x11mm) were divided in 8 groups: G1 (5 implants/EH/CAD-CAM), G2 (5 Implants/CM/CAD-CAM), G3 (5 Implants/EH/Conventional) , G4 (5 Implants/CM/Conventional), G5 (4 Implants/EH/CAD-CAM), G6 (4 Implants/CM/CAD-CAM) G7 (4 Implants/EH/Conventional) and G8 (4 Implants/CM/Conventional). DIC analysis were quantitative and qualitatively made with a 250N load at first molar central fossa, which were established in different regions of interest for analysis as C1 (cervical 1) and A1 (apical 1) to distal to the last implant, C2 (cervical 2) and A2 (apical) for mesial region to the last implant. Statistically significant differences were found for number of implants in all regions examined [C1 (p=0.002), A1 (p=0.01), C2 (p=0.001) and A2 (p=0.004)], for connections differences were found in the C2 region (p <0.05) and for the bar region at A2 (p=0.003). According to the results it can be concluded that the prosthesis with four implants showed a higher stress at the apical regions, there was no significant difference in the concentration of stress for EH and CM connections, except for the C2 region, where there was a higher concentration of stress for CM connection, and comparing bars obtained methods, conventional bars showed a higher concentration of stresses in prosthesis with 5 implants.
32

Métodos numéricos aplicados a mecânica da fratura: avaliação da integridade estrutural de componentes nucleares / NUMERICAL METHODS APPLIED TO THE FRACTURE MECHANICS: INTEGRITY TRUCTURAL OF NUCLEAR COMPONENTS

Claudio Roberto Soares 25 May 2009 (has links)
Nenhuma / A tenacidade à fratura avalia a resistência à propagação de uma trinca e tornou-se uma importante propriedade a ser considerada em metodologias para avaliação de integridade estrutural de componentes mecânicos em geral. A principal metodologia para avaliação dos efeitos da perda de restrição à plasticidade (Teoria J-Q) representa um grande passo para a inclusão dos efeitos geométricos nos estudos da fratura. Alguns avanços têm sido propostos para a obtenção de um parâmetro para transferência de valores de tenacidade obtidos em laboratório para o componente estrutural real. Assim, neste trabalho teórico de pesquisa foram realizadas diversas análises numéricas 3D, com o objetivo de compreender os efeitos da perda de restrição à plasticidade sobre os valores de tenacidade à fratura. Parâmetros como tamanho de trinca e geometria do corpo-de-prova foram analisados para fornecer informações mais detalhadas sobre a perda de restrição à plasticidade. Esta análise revelou uma variação da integral J e do parâmetro Q com a espessura de cada corpo-de-prova. Novas curvas J-QA foram traçadas para a descrição do nível de restrição à plasticidade e para um ajuste dos valores mais realísticos de tenacidade à fratura. Também foram comparados os resultados com o código ASME, onde foi possível ver como o mesmo tem um conceito extremamente conservador. / The fracture toughness is used to evaluate the resistance to the propagation of a crack and became an important property to be considered in methodologies for structural integrity evolution of mechanical components in general. The main methodology for assessing the crack-tip constraint (JQ Theory) represents a major step towards the inclusion of geometrical effects in studies of fracture. Some advances have been proposed for a parameter to transfer values of toughness obtained in laboratory to real structural components. Thus, theoretical work in this research consisted of several 3D numerical analysis with the aim of understanding the constraint effects on the values of fracture toughness. Several parameters such as crack size and specimens geometry were analyzed to provide detailed information about constraint effects. This analysis revealed a variation of J integral and the parameter Q with the thickness of each specimen. New J-Q curves were drawn to describe the level constraint of plasticity and a more realistic set of values of fracture toughness. The results were compared with the ASME code, where it was possible to see that the code criteria are very conservative.
33

Análise da distribuição de tensão em protocolo mandibular confeccionado pelo sistema convencional e CAD/CAM, variando tipo, número e inclinação dos implantes / Stress distribution analysis of mandibular protocol confectioned by the conventional system and cad/cam, ranging type, number and inclination of the implants

Cristian Sbardelotto 19 January 2016 (has links)
As próteses totais fixas implantossuportadas tem ganhado cada dia mais seu espaço no tratamento reabilitador de pacientes edêntulos, pois se trata de uma forma de tratamento que atende todos os quesitos funcionais e estéticos. Ainda não existe na literatura um consenso de qual a configuração que melhor distribui as tensões aos implantes e tecidos adjacentes. O objetivo deste estudo foi comparar as tensões geradas na interface osso-implante de próteses totais mandibulares implantossuportadas através do método de correlação de imagens digitais (CID). Foram analisadas duas configurações diferentes quanto a quantidade e posicionamento de implantes (4 ou 5 implantes), diferentes conexões [hexágono externo (HE) e cone morse (CM)] e barras para prótese fixa implantossuportada obtidas por fundição convencional e usinadas pelo sistema CAD/CAM. Foram confeccionados modelos em poliuretano, utilizando implantes de 3,75x11mm, divididos em 8 grupos: G1 (5 implantes/HE/CAD-CAM), G2 (5 Implantes/CM/CAD CAM), G3 (5 Implantes/HE/Convencional), G4 (5 Implantes/CM/Convencional), G5 (4 Implantes/HE/CAD CAM), G6 (4 Implantes/CM/CAD CAM), G7 (4 Implantes/HE/Convencional) e G8 (4 Implantes/CM/Convencional). A análise por CID foi feita quantitativamente e qualitativamente, com aplicação de carga de 250N na fossa central do primeiro molar inferior, onde foram estabelecidas diferentes regiões de interesse para a análise, sendo denominadas de C1 (cervical 1) e A1 (apical 1) para região distal ao último implante, C2 (cervical 2) e A2 (apical) para região mesial ao último implante. Foram encontradas diferenças estatisticamente significantes para o número de implantes em todas as regiões analisadas [C1 (p=0,002), A1 (p=0,01), C2 (p=0,001), A2 (p=0,004)], para as conexões foram encontradas diferenças na região C2 (p<0,05) e para as barras na região A2 (p=0,003). De acordo com os resultados pode-se concluir que as prótese com 4 implantes apresentaram maior quantidade de tensões por tração nas regiões apicais, não houve diferença significativa na concentração de tensões para as conexões HE e CM, exceto para a região C2, onde houve maior concentração de tensão para conexão CM e em comparação ao método de obtenção das barras, as barras convencionais apresentaram maior concentração de tensões de tração nas próteses com 5 implantes. / The implant-supported fixed dental prostheses have been used to rehabilitate edentulous patients as it fulfills not only functional aspects but also esthetic questions. Literature shows that there is no consensus about the best configuration to distribute stress to the implants and surrounding tissues. The objective of this study was to compare the stress generated at the boneimplant interface of implant-supported mandibular dentures by a digital image correlation method (DIC). Two different configurations were analyzed for the implants quantity and position (4 or 5 implants), different connections [external hexagon (EH) and Cone Morse (CM)] and bars for implant-supported fixed prosthesis obtained by conventional casting and machined by CAD/CAM system. Models were prepared from polyurethane and implants (3.75x11mm) were divided in 8 groups: G1 (5 implants/EH/CAD-CAM), G2 (5 Implants/CM/CAD-CAM), G3 (5 Implants/EH/Conventional) , G4 (5 Implants/CM/Conventional), G5 (4 Implants/EH/CAD-CAM), G6 (4 Implants/CM/CAD-CAM) G7 (4 Implants/EH/Conventional) and G8 (4 Implants/CM/Conventional). DIC analysis were quantitative and qualitatively made with a 250N load at first molar central fossa, which were established in different regions of interest for analysis as C1 (cervical 1) and A1 (apical 1) to distal to the last implant, C2 (cervical 2) and A2 (apical) for mesial region to the last implant. Statistically significant differences were found for number of implants in all regions examined [C1 (p=0.002), A1 (p=0.01), C2 (p=0.001) and A2 (p=0.004)], for connections differences were found in the C2 region (p <0.05) and for the bar region at A2 (p=0.003). According to the results it can be concluded that the prosthesis with four implants showed a higher stress at the apical regions, there was no significant difference in the concentration of stress for EH and CM connections, except for the C2 region, where there was a higher concentration of stress for CM connection, and comparing bars obtained methods, conventional bars showed a higher concentration of stresses in prosthesis with 5 implants.
34

Análise de tensões em equipamentos de moagem da cana-de-açucar usando o método dos elementos finitos / Stress analysis in grinding equipment of cane sugar by using the finite element method

Fábio Caltarosso 04 September 2008 (has links)
O álcool produzido no Brasil por meio da cana-de-açúcar é um combustível alternativo que obteve seu espaço no mercado mundial junto com o interesse dos países industrializados em contribuir para a diminuição da poluição no planeta. Para o processo de produção do álcool, há várias etapas e, uma delas é a extração do caldo da cana-de-açúcar realizada, em sua grande maioria, por equipamentos denominados \"ternos de moenda\". Conhecer o comportamento destes equipamentos sob os esforços atuantes em sua estrutura é de suma importância para a realização de novos projetos destes e uma otimização dos já existentes. Para o conhecimento de tais tensões, tecnologias na área da engenharia auxiliada por computador (CAE) trazem programas de computador (softwares) capazes de cumprir tal finalidade. Muitos destes softwares são responsáveis por uma otimização no processo de concepção de um produto, pois os mesmos são capazes de detectar falhas em projetos com extrema facilidade, coisa que seria muito difícil por cálculos realizados manualmente. Assim, o objetivo deste trabalho é estudar as tensões atuantes num castelo de moenda 53\"x90\", peça de maior expressão no conjunto do terno de moenda de mesma bitola, para auxílio em futuros projetos e otimização dos já existentes. Para o conhecimento das tensões atuantes no castelo e utilização do Cosmosworks, software de elementos finitos que apresenta resultados com grande precisão, será utilizado. Depois de analisadas, as tensões atuantes no castelo foram apresentadas com ênfase aos pontos de maior concentração de tensão. A verificação de coeficientes de segurança elevados nas mais diversas regiões do castelo também foi explorada. Com base nos resultados apresentados pôde-se otimizar o castelo de moenda reduzindo seu peso próprio em 15%, que corresponde aproximadamente a 3.000 Kg. O conhecimento das tensões atuantes em componentes para o setor sucroalcooleiro oferece condições de se projetar novos equipamentos otimizados para um mercado cada vez mais globalizado e conseqüentemente mais competitivo. / The alcohol produced in Brazil through the sugar cane is an alternative fuel that acquire her space on the world market with the interest of industrialized countries to contribute to reducing the planet pollution. In the process of ethanol production, there are several steps and one is the extraction of juice from sugar cane held, in majority, of the equipment called \"milling housing\". Knowing the behavior of this equipment efforts engaged in its structure is of paramount importance for the realization of these new projects and an optimization of existing ones. To the knowledge of these stress, technologies in the field of computer-aided engineering (CAE) bring computer programs (software) capable of fulfilling this purpose. Many software are responsible for an optimization in the process of product design, due to the fact that they are capable of detecting projects flaws with great ease, when something would be very difficult handling calculation. The objective of this work is to study the stresses working in the milling housing, the greatest expression throughout the suit of milling, to help in future projects and optimization of existing ones. To the knowledge of the stress working in the housing Cosmoworks, software for finite element that gives results with great accuracy, had been used. After the analysis, stresses working in the housing were presented with emphasis on the points of greatest stress concentration. The proof of factor of safety in the most diverse regions of the housing had been also explored. Based on the results presented, it is possible to optimize the milling housing reducing its own weight by 15% which is approximately 3,000 Kg. Knowledge of stresses in active components for the sector offers conditions to design new equipment optimized for an increasingly globalised market and thereafter more competitive.
35

Análise de tensões em equipamentos de moagem da cana-de-açucar usando o método dos elementos finitos / Stress analysis in grinding equipment of cane sugar by using the finite element method

Caltarosso, Fábio 04 September 2008 (has links)
O álcool produzido no Brasil por meio da cana-de-açúcar é um combustível alternativo que obteve seu espaço no mercado mundial junto com o interesse dos países industrializados em contribuir para a diminuição da poluição no planeta. Para o processo de produção do álcool, há várias etapas e, uma delas é a extração do caldo da cana-de-açúcar realizada, em sua grande maioria, por equipamentos denominados \"ternos de moenda\". Conhecer o comportamento destes equipamentos sob os esforços atuantes em sua estrutura é de suma importância para a realização de novos projetos destes e uma otimização dos já existentes. Para o conhecimento de tais tensões, tecnologias na área da engenharia auxiliada por computador (CAE) trazem programas de computador (softwares) capazes de cumprir tal finalidade. Muitos destes softwares são responsáveis por uma otimização no processo de concepção de um produto, pois os mesmos são capazes de detectar falhas em projetos com extrema facilidade, coisa que seria muito difícil por cálculos realizados manualmente. Assim, o objetivo deste trabalho é estudar as tensões atuantes num castelo de moenda 53\"x90\", peça de maior expressão no conjunto do terno de moenda de mesma bitola, para auxílio em futuros projetos e otimização dos já existentes. Para o conhecimento das tensões atuantes no castelo e utilização do Cosmosworks, software de elementos finitos que apresenta resultados com grande precisão, será utilizado. Depois de analisadas, as tensões atuantes no castelo foram apresentadas com ênfase aos pontos de maior concentração de tensão. A verificação de coeficientes de segurança elevados nas mais diversas regiões do castelo também foi explorada. Com base nos resultados apresentados pôde-se otimizar o castelo de moenda reduzindo seu peso próprio em 15%, que corresponde aproximadamente a 3.000 Kg. O conhecimento das tensões atuantes em componentes para o setor sucroalcooleiro oferece condições de se projetar novos equipamentos otimizados para um mercado cada vez mais globalizado e conseqüentemente mais competitivo. / The alcohol produced in Brazil through the sugar cane is an alternative fuel that acquire her space on the world market with the interest of industrialized countries to contribute to reducing the planet pollution. In the process of ethanol production, there are several steps and one is the extraction of juice from sugar cane held, in majority, of the equipment called \"milling housing\". Knowing the behavior of this equipment efforts engaged in its structure is of paramount importance for the realization of these new projects and an optimization of existing ones. To the knowledge of these stress, technologies in the field of computer-aided engineering (CAE) bring computer programs (software) capable of fulfilling this purpose. Many software are responsible for an optimization in the process of product design, due to the fact that they are capable of detecting projects flaws with great ease, when something would be very difficult handling calculation. The objective of this work is to study the stresses working in the milling housing, the greatest expression throughout the suit of milling, to help in future projects and optimization of existing ones. To the knowledge of the stress working in the housing Cosmoworks, software for finite element that gives results with great accuracy, had been used. After the analysis, stresses working in the housing were presented with emphasis on the points of greatest stress concentration. The proof of factor of safety in the most diverse regions of the housing had been also explored. Based on the results presented, it is possible to optimize the milling housing reducing its own weight by 15% which is approximately 3,000 Kg. Knowledge of stresses in active components for the sector offers conditions to design new equipment optimized for an increasingly globalised market and thereafter more competitive.
36

Programa para análise de juntas coladas: compósito/compósito e metal/compósito / Software for analyses of bonded joints: composite-composite and metal-composite

Ribeiro, Marcelo Leite 18 March 2009 (has links)
O presente trabalho consiste basicamente no desenvolvimento de um programa de engenharia denominado SAJ (sistema de análise de juntas) capaz de realizar uma análise detalhada do comportamento de dois dos diversos tipos de juntas coladas existentes, a junta simples colada (\"single lap joint\") e a junta dupla colada (\"double lap joint\"). Sendo que foram analisadas juntas coladas com aderentes de material compósito ou, então, compostas de aderentes de compósitos e metal. O programa de engenharia desenvolvido possibilita o cálculo das tensões, dos esforços e dos deslocamentos nessas juntas. Para validar o referido programa, os resultados obtidos do mesmo foram confrontados com os resultados obtidos para condições semelhantes utilizando \"softwares\" comerciais de elementos finitos e de cálculo de juntas. Após a validação do programa, são apresentados alguns estudos de fatores que influenciam na resistência da junta colada, verificando a influência do comprimento de \"overlap\" (sobreposição), a rigidez do adesivo e a espessura da camada adesiva. Também é apresentada uma análise de falha dos aderentes de compósito evidenciando assim, as potencialidades e limitações desta ferramenta computacional para a área de desenvolvimento de produto. / This work consists on the development of software called SAJ which can analyze a bonded joint behavior in detail, not only for single lap joint, but also, for double lap joint. These joints could be made of composite/composite materials or metal/composite as adherentes. The software developed can calculate the joints stresses, loads and displacements. The results obtained are compared to the results obtained using commercial software and the same problems proposed. After the validation of SAJ, some studies were performed in order to determine how some characteristics affect the joint stresses distribution as overlap length, adhesive elastic modulus, adhesive thickness and a failure analysis of composite adherents showing the potential and limitation of this computational tool for the product development area.
37

Análise biomecânica de implantes odontológicos / Biomechanical Analysis of Dental Implants

Silva, Naiara Cristina da 09 March 2007 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / It was objectified in this dissertation to analyze the distribution of the stress and displacements in the bone-implant interface, using the finite element method. The implants had been analyzed in two distinct situations: put directly in the two bone layers, cortical and trabecular, simulating the situation of immediate load, previous to osseointegration, and with the implants involved by a denser bone layer simulating the occurrence of the osseointegration. The geometry of the bone layers was obtained by means of computerized cat scan and the format of the implants and the prosthetic components had been supplied by the Neodent (Curitiba, Brazil). The variables analysed had been: geometry of the implants (cylindrical and taper), abutment (internal hexagon and morse taper) and the positioning of the implants in relation to the alveolar bone boards (buccaly and palatine). With this, 16 groups of analysis were formed, for which bidimensional models of the alveolus of extration of an upper central incisor had been constructed, simultaneously with the geometry of the implants, for the numerical simulation. The results of bigger relevance had been: the Von Mises stresses, principal stress (maximum and minimum) and the shear stresses, as well as the relative displacements presented by the bone-implant structure. Through the analyses, one concluded that different implant geometries adjust themselves better to each situation (immediate load and osseointegrated implant), and that the Titamax CM implant, of cylindrical format with prosthetic connection, morse taper, in palatine position was the one that best adapted itself. The found values can lead to a better understanding of the biomechanics around the implants. Despite of being a preliminary study, the work supplies subsidies for the accomplishment of future researches, since the methodology used can be applied in a variety of similar cases found in the Implantology. / Objetivou-se nesta dissertação analisar a distribuição das tensões e deslocamentos na interface osso-implante, utilizando o método dos elementos finitos. Os implantes foram analisados em duas situações distintas: assentados diretamente nas duas camadas ósseas, cortical e trabecular, simulando a situação de carga imediata, anterior a osseointegração; e com os implantes envolvidos por uma camada óssea mais densa simulando a ocorrência da osseointegração. A geometria das camadas ósseas foi obtida por meio de tomografia computadorizada. O formato dos implantes e componentes protéticos foram fornecidos pela Neodent (Curitiba, Brasil). As variáveis analisadas foram: geometria dos implantes (cilíndrico e cônico), pilar (hexágono interno e cone morse) e o posicionamento dos implantes em relação às tábuas ósseas alveolares (vestibularizado e palatinizado). Com isto formou-se 16 grupos de análise, para os quais foram construídos modelos bidimensionais do alvéolo de extração de um incisivo central superior, conjuntamente com as geometrias dos implantes, para a simulação numérica. Os resultados de maior relevância foram: as tensões de Von Mises, tensões principais (máximas e mínimas) e as tensões cisalhantes, bem como os deslocamentos relativos apresentados pela estrutura osso-implante. Por meio das análises concluiu-se que, diferentes geometrias de implantes se ajustam melhor a cada situação (carga imediata e implante osseointegrado), e que o implante Titamax CM, de formato cilíndrico com conexão protética cone morse posicionado palatinizado, foi o que melhor adaptou-se. Os valores encontrados podem levar a um melhor entendimento da biomecânica ao redor dos implantes. Apesar de ser um estudo preliminar, o trabalho realizado fornece subsidio para a realização de pesquisas futuras, pois a metodologia utilizada pode ser empregada em uma variedade de casos similares encontrados na implantodontia. / Mestre em Engenharia Mecânica
38

Programa para análise de juntas coladas: compósito/compósito e metal/compósito / Software for analyses of bonded joints: composite-composite and metal-composite

Marcelo Leite Ribeiro 18 March 2009 (has links)
O presente trabalho consiste basicamente no desenvolvimento de um programa de engenharia denominado SAJ (sistema de análise de juntas) capaz de realizar uma análise detalhada do comportamento de dois dos diversos tipos de juntas coladas existentes, a junta simples colada (\"single lap joint\") e a junta dupla colada (\"double lap joint\"). Sendo que foram analisadas juntas coladas com aderentes de material compósito ou, então, compostas de aderentes de compósitos e metal. O programa de engenharia desenvolvido possibilita o cálculo das tensões, dos esforços e dos deslocamentos nessas juntas. Para validar o referido programa, os resultados obtidos do mesmo foram confrontados com os resultados obtidos para condições semelhantes utilizando \"softwares\" comerciais de elementos finitos e de cálculo de juntas. Após a validação do programa, são apresentados alguns estudos de fatores que influenciam na resistência da junta colada, verificando a influência do comprimento de \"overlap\" (sobreposição), a rigidez do adesivo e a espessura da camada adesiva. Também é apresentada uma análise de falha dos aderentes de compósito evidenciando assim, as potencialidades e limitações desta ferramenta computacional para a área de desenvolvimento de produto. / This work consists on the development of software called SAJ which can analyze a bonded joint behavior in detail, not only for single lap joint, but also, for double lap joint. These joints could be made of composite/composite materials or metal/composite as adherentes. The software developed can calculate the joints stresses, loads and displacements. The results obtained are compared to the results obtained using commercial software and the same problems proposed. After the validation of SAJ, some studies were performed in order to determine how some characteristics affect the joint stresses distribution as overlap length, adhesive elastic modulus, adhesive thickness and a failure analysis of composite adherents showing the potential and limitation of this computational tool for the product development area.
39

"Análise comparativa pelo método dos elementos finitos bidimensional das tensões geradas nas estruturas de suporte de prótese parcial removível de extremidade livre inferior sobre rebordo residual ascendente distal e descendente distal"

Camargo, Renato Zanutto Bueno de 14 April 2005 (has links)
Nesta pesquisa, foi realizada uma análise comparativa, por meio do método dos elementos finitos bidimensional linear, das deformações e tensões geradas a partir da aplicação de uma carga de 100N, nas estruturas de suporte (fibromucosa,ligamento periodontal, osso cortical e osso esponjoso) de dois modelos que simulam um hemiarco mandibular associada a uma prótese parcial removível de extremidade livre dista inferiorl, quando da variação da inclinação do rebordo residual no plano sagital. O modelo A (MA) foi desenhado com um rebordo ascendente distal com 15 graus de inclinação e o modelo B (MB) com um rebordo descendente distal com 15 graus negativos, ambos em relação ao plano oclusal. Nos dois modelos aplicou-se uma carga primeiramente na cúspide médio-vestibular do primeiro molar inferior artificial (C1) e depois na cúspide vestibular do segundo pré-molar inferior (C2), por meio do programa I-deas (software de elementos finitos) onde foram feitas as análises de deformações e tensões e processamento das imagens. Fez-se então uma análise comparativa dos carregamentos (C1 e C2) em cada modelo individualmente e entre os dois modelos(MA e MB). Os resultados permitiram concluir que: 1) A inclinação do rebordo residual no plano sagital influenciou na distribuição e na intensidade das tensões das estruturas de suporte; 2) No osso cortical as tensões foram mais localizadas e de maior intensidade que no osso esponjoso; 3) A diferença de deformação entre fibromucosa e ligamento periodontal foi maior quando a carga foi aplicada no primeiro molar, de ambos os modelos, sendo a mais expressiva no rebordo ascendente distal; 4) As tensões de compressão foram maiores em intensidade e melhor distribuídas no osso esponjoso e no osso cortical, quando comparadas as tensões de tração; 5) O rebordo ascendente distal se mostrou mais favorável à distribuição das tensões nas estruturas de suporte quando comparado ao rebordo descendente distal; 6) Nos dois modelos a aplicação da carga no primeiro molar gerou um maior torque sobre o dente suporte para a distal do que quando aplicado no segundo pré-molar, principalmente no rebordo descendente distal; 7) As estruturas de suporte do rebordo residual foram mais solicitadas em C1 que em C2, em ambos os modelos, principalmente no rebordo ascendente distal; 8) No dente suporte as tensões nas estruturas de suporte foram mais axiais quando o carregamento ocorreu no segundo pré-molar inferior, em ambos os modelos. / In this study, a two-dimensional finite element comparative analysis of the stress distribution and of displacement in the supporting structures – oral mucosa,periodontal ligament, compact and cancellous bone – was carried out for a distal extension base removable partial denture (RPD), modeled on two mandibular dental archs with different types of residual ridge when aplaying loads of 100N. The A model (MA) was developed to include a distal ascending alveolar ridge with a 15-degrees positive inclination, while the B model (MB) was prepared with a distal descending alveolar ridge with a 15-degrees negative inclination. Both models had a load applied inicially on the lower first molar median cusp (C1) and then on the lower second premolar buccal cusp (C2). Using the FEA software (I-DEAS, USA) for the stress distribution and displacement analysis of the generated images. A comparative analysis was them performed on the C1 and C2 loads for which and both models (MA and MB).The results showed that: 1 – The alveolar ridge inclination showed some degree of on the stress distribution and intensity generated by the RPD; 2 –The compact bone showed greater stress concentration and intensity than the cancellous bone; 3 – The ratio between oral mucosa and periodontal ligament displacement showed greater values when load was applied on the lower first molar for both models. The ratio was higher for the distal ascending alveolar ridge; 4- The compressive stress showed greater intensity and better range of distribution than the tensile stress for both the compact and cancellous bone; 5 – The distal ascending residual ridge had a more favourable stress distribution than distal descending conterpart ; 6 – The load applied on the lower first molar produced more distal torquing on the supporting tooth than that on the lower second premolar ,specially on the distal descending residual ridge; 7 – the load applied on the lower firt molar generated greater amount of stress on the residual ridge supporting structures for both models, but specially for the distal ascending residual ridge; 8 – The load applied on the lower second premolar produced more vertical forces on the supporting structures of the tooth for both models.
40

"Análise comparativa, pelo método dos elementos finitos bidimensional, das tensões geradas nas estruturas de suporte de prótese parcial removível de extremidade livre inferior, em rebordo horizontal e descendente-ascendente" / A two-dimensional finite element analysis of the stress distribution in the supporting structures of a distal extension base removable partial denture over a horizontal and descending/ascending residual ridge.

Plaza, Carla Aparecida Seno 03 February 2005 (has links)
O objetivo deste estudo foi avaliar, pelo método dos elementos finitos bidimensional, a distribuição das tensões geradas nas estruturas de suporte das próteses parciais removíveis (PPR) - osso cortical, osso esponjoso, fibromucosa e ligamento periodontal, em modelos de arcos parcialmente dentados de extremidade livre inferior, em rebordo horizontal (MA) e descendente-ascendente (MB). Foram confeccionados dois modelos de quadrante de mandíbula em AUTOCAD 2004 (Autodesk Inc., USA), contendo apenas o primeiro pré-molar e rebordo residual, sendo repostos o segundo pré-molar e primeiro molar pela PPR, tendo como dente suporte o primeiro pré-molar com apoio oclusal distal. Posteriormente, foi aplicada carga axial de 100 N nas cúspides dos dentes artificiais da PPR (somente sobre o 1 o molar - C1 e somente sobre o 2 o pré-molar - C2). Os modelos confeccionados em AUTOCAD foram transferidos para o programa I-DEAS (software de elementosfinitos), que discretizou-os e realizou a distribuição das tensões sob as condições de aplicação de carga citadas. Pôde–se observar que no osso esponjoso, a maior deformação e tensão de compressão foram observadas ao redor do dente suporte, principalmente no terço cervical distal para a deformação e no ápice do dente para a tensão de compressão durante a aplicação de carga sobre o segundo pré-molar no rebordo horizontal (0,003 mm e 0,621 N/mm 2 , respectivamente). Já no rebordo descendente-ascendente, as áreas solicitadas foram as mesmas, apresentando deformação e tensão de compressão máximas de 0,003 mm e 0,609 N/mm 2 . Para a fibromucosa, pode-se notar que no rebordo horizontal, a maior deformação e tensão de compressão ocorreram abaixo do ponto de aplicação de carga, ou seja, no primeiro molar, com valores de 0,137 mm e 0,144 N/mm 2 . No rebordo descendente-ascendente, a área de maior deformação e tensão de compressão localizaram-se na porção ascendente do rebordo em direção do trígono retromolar, com valores de 0,131 mm e 0,122 N/mm 2 , respectivamente. Diante dos limites do presente estudo pode-se concluir que: 1 - O osso cortical apresenta uma concentração de tensões maior que o osso esponjoso; 2 – O osso cortical apresenta uma deformação mais restrita em área que o osso esponjoso; 3 - O rebordo descendente-ascendente com a aplicação de carga sobre o primeiro molar (MB-C1) apresenta a maior deformação da fibromucosa quando comparada à deformação sofrida pelo ligamento periodontal, na proporção de 10:1; 4 - O rebordo descendente-ascendente apresenta uma distribuição de tensões menos favorável que o rebordo horizontal; 5 - A aplicação de carga no primeiro molar gera mais torque sobre o dente para distal do que a aplicação de carga sobre o segundo pré-molar. / This study is a two-dimensional finite element analysis (FEA) of the stress distributionin the supporting structures – compact and cancellous bone; periodontal ligament and oral mucosa – for a distal extension base removable partial denture (RPD) modeled on mandibular dental archs with two residual ridge forms: horizontal and descending-ascending. The two experimental quadrant models were developed in the AUTOCAD 2004 (Autodesk Inc., USA), software to include the first premolar asthe dental support with a distal occlusal rest; the second premolar and first molar as the artificial teeth inserted on the base over an RPD framework and the residual ridge. These models were discretized on the FEA software (I-DEAS, USA) and an axial load of 100 N was applied to the mesh on the artificial teeth cusps either on the first mola r (C1) or on the second premolar (C2). It was noticed that, in the cancellous bone, the maximum strain was around the supporting tooth, mainly in the distalcervical third (0.003 mm) while the largest compression tension (CT) was at the tooth apex when the load was applied over the second premolar, with a horizontal residual ridge (0,621 N/mm 2 ). When the ridge was descending-ascending, the areas affected were the same, showing 0,003 mm and 0,609 N/mm 2 , respectively as the maximum displacement and CT. In the oral mucosa, the largest results occurred when the load application point was over the first molar and the residual ridge was horizontal: 0,137 mm and 0,144 N/mm 2 . The descending-ascending alveolar ridge showed the maximum displacement and CT in the ascending segment of the residual ridge, toward the retromolar trigon, with 0,131 mm and 0,122 N/mm 2 , respectively. Within the constraints of this study, it was concluded that: 1 – The compact bone shows greater stress concentration than the cancellous bone; 2 – The compact bone shows greater area displacement concentration than the cancellous bone; 3 – The descending-ascending residual ridge with the load application on the first molar showed the largest displacement of the oral mucosa when compared to the periodontal ligament displacement with a 10:1 ratio; 4 – The descending-ascending residual ridge had a less favourable stress distribution than its horizontal counterpart; 5 – The load applied on the first molar produced more distal torquing on the supporting tooth than that on the second premolar.

Page generated in 0.0603 seconds