• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 26
  • Tagged with
  • 27
  • 27
  • 27
  • 26
  • 23
  • 23
  • 12
  • 8
  • 8
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação biomecânica de pré-molares superiores restaurados com diferentes monômeros resinosos / Biomechanical evaluation of pre-molars restored with different monomers resins

Barreto, Bruno de Castro Ferreira 18 August 2018 (has links)
Orientador: Luis Roberto Marcondes Martins / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T01:00:44Z (GMT). No. of bitstreams: 1 Barreto_BrunodeCastroFerreira_D.pdf: 19459123 bytes, checksum: 7994f36259737060feeacf56adfc4410 (MD5) Previous issue date: 2011 / Resumo: O objetivo deste trabalho foi avaliar a viabilidade da utilização de um método de geração de modelo tridimensional de pré-molar superior, com capacidade de representar as tensões de contração de polimerização por meio de analogia térmica com aplicabilidade ao método de elementos finitos. Após isto, neste trabalho avaliou-se o comportamento biomecânico de pré-molar superior enfraquecido, restaurado com dois tipos de monômeros resinosos por meio de análise por elementos finitos comparando ao dente hígido. Para geração do modelo 3D foi selecionado primeiro pré-molar superior hígido. O dente escolhido foi mapeado com scanner de contato 3D (Modela, Roland) e, logo após, o esmalte foi degradado com ácido clorídrico-10%, para a realização da digitalização da imagem da dentina coronária. Para o mapeamento do volume pulpar, a dentina foi seccionada longitudinalmente no sentido vestíbulo-palatino e realizada a digitalização do espaço negativo referente à polpa. Os arquivos com extensão *.STL (steriolitografia) foram exportados para programa Bio-CAD (Rhinoceros-3D). Volumes de cada estrutura dental e técnicas restauradoras foram gerados por meio da associação de superfícies complexas não regulares (NURBS). Os modelos foram exportados para o programa de elementos finitos (Ansys Workbench v12), onde foi realizado o processo de malhagem, inserção das propriedades mecânicas e condições de contorno. Foram gerados 9 modelos, sendo um do dente hígido e 8 modelos de acordo com os 3 fatores em estudo: tipo de perda estrutural em dois níveis: com e sem socavamento de cúspide, tipo de monômero resinoso em dois níveis: silorano e metacrilato, e aplicação de carregamento de compressão em dois níveis: com carregamento e sem carregamento. Os resultados foram analisados pelo critério de tensão máxima principal e von Mises. Os resultados obtidos mostraram consonância com a literatura, e a observação do estudo comprovou que o uso do modelo geométrico 3D com analogia térmica para contração de polimerização é adequado para a análise por elementos finitos. Concluiu-se que a presença do socavamento apresentou aumento da concentração de tensões nas estruturas dentárias, principalmente quando associado ao uso da resina de metacrilato; o tipo de monômero resinoso e a diferença de contração volumétrica influenciaram na concentração das tensões no material, na interface e no substrato, e que o carregamento compressivo influenciou os valores de tensão / Abstract: The aim of this study was to evaluate the feasibility of using a method of generating three-dimensional model of maxillary premolar tooth, with ability to represent the tensions of polymerization shrinkage through thermal analogy with applicability to the finite element method. After that, this study evaluated the biomechanical behavior of weakened premolar, restored with two types of resin monomers through finite element analysis compared to healthy teeth. To generate the 3D model was selected first premolar healthy. The tooth was chosen mapped contact with scanner (3D Models, Roland) and, soon after, the enamel was degraded with hydrochloric acid-10%, to perform the scan image of the coronal dentin. To map the volume pulp, dentin was sectioned longitudinally in the buccopalatal and performed scanning the negative space on the pulp. The files with extension *. STL (steriolitography) were exported to Bio-CAD program (Rhinoceros-3D). Volumes of each tooth structure and restorative techniques were generated through the association of non-regular complex surfaces (NURBS). The models were exported to the finite element program (Ansys Workbench v12), which had undertaken the process of mesh size, insertion of the mechanical properties and boundary conditions. 9 models were generated, one of the healthy tooth and eight models according to three factors studied: type of structural loss at two levels: with and without undermining the cusp, type of resin monomer into two levels: Silorane and methacrylate, and application of compression loading on two levels: with and without loading. The results were analyzed by the criterion of maximum principal stress and von Mises. The results showed agreement with the literature, and observation of the study showed that use of the 3D geometric model with analogy to thermal polymerization shrinkage is suitable for finite element analysis. It was concluded that the presence of undermining showed an increase in stress concentration in the dental structures, especially when associated with the use of methacrylate resin, type of resin monomer and the difference in shrinkage influence the concentration of stresses in the material, in the interface and substrate, and the compressive loading influenced the values of tension / Doutorado / Dentística / Doutor em Clínica Odontológica
12

Efeito da ciclagem mecânica na resistência de união à dentina humana de uma resina composta associada a dois sistemas adesivos / Effect of mechanical cycling on the human dentin bond strength, of a composite associated to two adhesive systems

Lucia Helena Vieira Diniz Bodi 24 March 2010 (has links)
Diante da grande preocupação atual por sorrisos que também embelezem um rosto, a escolha por materiais estéticos impulsiona pesquisas, que tem como objetivo não só melhorar a qualidade, mas, facilitar o uso desses materiais pelos profissionais. Assim, a proposta desse trabalho foi avaliar a influência da ciclagem mecânica na resistência de união de uma resina composta associada a um sistema adesivo convencional e um autocondicionante à dentina humana hígida por meio de teste de microtração. Para o estudo, foram utilizados 40 terceiros molares humanos hígidos, nos quais as faces oclusais foram lixadas até a obtenção de uma superfície plana com exposição do tecido dentinário. Os dentes foram divididos, aleatoriamente, em quatro grupos (n=10) de acordo com o sistema adesivo utilizado e a realização ou não da ciclagem mecânica: G1 Sistema adesivo Adper Single Bond 2 sem ciclagem mecânica (SB); G2 Sistema adesivo Clearfil SE Bond sem ciclagem mecânica (CF); G3 - Sistema adesivo Adper Single Bond 2 com ciclagem mecânica (SBC); G4 - Sistema adesivo Clearfil SE Bond sem ciclagem mecânica (CFC). Blocos de resina composta foram confeccionados nas superfícies dentinárias após aplicação do sistema adesivo correspondente. Após esse passo, os espécimes dos grupos 3 e 4 passaram por ciclagem mecânica enquanto o restante ficou armazenado em água destilada, mantidos em estufa à 37ºC até o momento do recorte dos espécimes para o teste de microtração. Os corpos de prova foram seccionados em planos perpendiculares à área de união para obtenção de espécimes com área de secção transversal aproximada de 1,0 mm², que foram tracionados, em máquina de ensaios universal, a velocidade de 0,5mm/min. Os resultados de resistência de união foram analisados usando o teste estatístico análise de variância e os modos de fratura foram avaliados em lupa estereoscópica (25X). Não foram encontradas diferenças estatísticas entre os grupos (p<0,05). Pôde-se concluir que não houve influência da ciclagem mecânica nos valores de resistência de união da resina composta associada a ambos os sistemas adesivos utilizados. / In face of an increasing concern about a smile profile that also enhances the overall facial appearance (esthetics), the choosing for more esthetic restorative materials, set in motion researches that have as objective not only the improvement of the quality, but also the easiness of use of these materials by clinicians. The purpose of this in vitro study was to evaluate, by means of a micro tensile test, the influence of the mechanical cycling, on the bond strength of a resin composite, associated to a total etch and a self etching adhesive systems, on the surfaces of sound human dentin. For this study, forty freshly extracted third molars had their oclusal surfaces grounded parallel-flat, until the dentin surfaces were completely exposed. The teeth were randomly divided in four groups (n=10) in accordance with the type of adhesive system and the mechanical cycling treatment, being: G1 Adper Single Bond 2 without mechanical cycling (SB); G2 Clearfill SE Bond without mechanical cycling (CF); G3 - Adper Single Bond 2 with mechanical cycling (SBC); G4 - Clearfill SE Bond without mechanical cycling (CFC).Following the application of the adhesive systems, regarding to each experimental condition, blocks of Z-250 composite were built, on the dentinal surfaces. After this step, the G3 and G4 specimens were submitted to the mechanical cycling test, while the G1 and G2 specimens were kept stored in distilled water at 37°C, until the moment of sectioning for the microtensile test. The specimens were seccionated perpendicularly to their adhesive area to obtain beam shaped specimens with approximate cross-section area of 0.8mm2, which were readily submitted to the microtensile test in a universal test machine with a crosshead speed of 0.5mm/min. The fracture modes were evaluated by means of a stereoscopic microscope (25x). There were no significant statistical differences founded in the bond strength values among the tested groups.
13

Análise da distribuição das tensões em maxila submetida à expansão cirurgicamente assistida com aparelho ósseo-suportado / Analysis of the distribution of maxillary stresses submitted to surgically assisted maxillary expansion with a bone-supported device

Tieghi Neto, Victor 22 June 2017 (has links)
A expansão de maxila cirurgicamente assistida (EMCA) é a modalidade de tratamento que tem como objetivo romper as regiões de reforço maxilar permitindo seu movimento expansivo gradativamente. Tal movimento pode ser realizado às custas de aparelhos dento-suportado, dento-muco-suportado, implanto-suportados ou ósseo-suportado. Os efeitos produzidos pelo tratamento vão desde alterações esqueléticas (aumento da base, cavidade e do espaço aéreo nasais) até inclinações dentárias (principalmente nos dentes de suporte do aparelho expansor), dentre outras. O objetivo desta pesquisa foi avaliar, por meio do Método de Elementos Finitos (MEF), a distribuição das tensões produzidas pela EMCA nas estruturas maxilares utilizando-se aparelho expansor ósseo-suportado. Material e métodos: Foi confeccionado um modelo tridimensional de maxila para simulação da EMCA com osteotomia tipo LeFort I descendente sem degrau, com disjunção pterigomaxilar utilizando um modelo de aparelho ósseo-suportado para o teste com a simulação de abertura de 1mm. Os resultados mostraram maior abertura da maxila na região anterior de incisivos a pré-molar (1 mm) e em menor quantidade (0,6mm) na região de molares. A tensão máxima principal (TMXP) mostrou a concentração de tensões principalmente em toda face palatina da maxila de pré-molar ao túber maxilar. Pela face lateral, ficou mais evidente a TMXP nas região de osso alveolar posterior ao pré-molar, molares e túber, assim como na região de pilar zigomático acima da osteotomia. Pelo plano transversal foi possível observar a transmissão de tensões ao longo das estruturas ósseas mostrando pouca dissipação para as raízes do molar. Enquanto que as forças de compressão (Tensão Mínima Principal), evidenciadas pela tensão mínima principal, se manifestaram nas áreas de pilar zigomático e adjacentes as osteotomias, assim como na áreas de contato do apoio do aparelho com o osso palatino. Tensões de tração e compressão também foram evidenciadas na região de processo pterigoide. A análise de tensão de Von Mises mostrou que a parte que mais sofre estresse é a haste que liga o módulo do aparelho com a plataforma de apoio. Conclusão: Houve maior abertura da maxila na região anterior e as tensões resultantes de forças transmitidas ao osso alveolar dos dentes adjacentes ao aparelho, parecem não ser suficientes para deslocar os dentes. / Surgically assisted maxillary expansion (SARME) is the modality of treatment that aims to weaken the points of maxillary reinforcement allowing its gradual expansion. Such movement can be performed at the expense of dento-supported, dento-muco-supported, implanto-supported or bony-backed devices. The effects produced by the treatment range from skeletal changes (increase of nasal base, cavity and nasal air space) to dental inclinations (mainly in the supporting teeth of the expander apparatus), among others. The objective of the present research was to evaluate the distribution of stress produced by SARME in the maxillary structures using the bone-supported expander apparatus by the Finite Element Method (FEM). Material and methods: A three-dimensional hemi-maxilla model was simulated for SARME with a non-step descending LeFort I osteotomy with pterygomaxillary disjunction using a bone-supported device model for the 1mm aperture simulation test. The results showed a greater opening of the maxilla in the anterior region of the incisors to the premolar (1 mm) and smaller (0.6 mm) in the molar region. The principal maximal stress (TMXP) showed the concentration of the tension forces mainly in all the palatine face of the pre-molar maxilla to the maxillary tuft. Due to the lateral aspect, the TMXP was more evident in the posterior alveolar bone region, the molars and tuber, as well as in the epilating zygomatic region above the osteotomy. From the transversal plane, it was possible to observe the transmission of stress along the bony structures showing little dissipation for the roots of the molar. Meanwhile, the forces of compression (Principal Minimum Tension) evidenced by the principal minimal stress, were manifested in the areas of the zygomatic pillar adjacent to the osteotomies, as well as in the areas of contact of the support of the apparatus with the palatine bone. Tension and compression forces were also evidenced in the pterygoid process region. Von Mises\' stress analysis showed that the most stressed part is the rod connecting the device module to the support platform. Conclusion: There was a greater opening of the maxilla in the anterior region and the resulting forces of tension transmitted to the alveolar bone of the teeth adjacent to the appliance did not seem to be sufficient to displace the teeth.
14

Comparação da eficiência na distribuição de tensões de diferentes modelos de retentores intrarradiculares: uma análise de elementos finitos tridimensional / Efficiency comparison in stress distribution of different post types: a 3D finite element analysis

Mayer-Santos, Eric Mayer dos 03 November 2016 (has links)
Elementos dentais endodonticamente tratados geralmente necessitam de retentores intrarradiculares para prover retenção e suporte ao processo restaurador. O objetivo deste estudo foi comparar a eficiência na distribuição de tensões de diferentes modelos de retentores intrarradiculares, através do método dos elementos finitos. Um modelo tridimensional de elementos finitos foi desenvolvido para representar um incisivo central superior endodonticamente tratado e restaurado com uma coroa total cerâmica, e quatro tipos diferentes de pinos pré-fabricados (dois convencionais, e dois modelos customizados) foram inseridos sob esse modelo e comparados quanto à distribuição das tensões às quais foram submetidos. Os quatro pinos diferem em formato e material de composição. O primeiro é um pino pré-fabricado metálico customizado referente à uma patente, com porção coronária anatômica (com curvaturas e formatos semelhantes à coroa anatômica) e flange rosqueável. O segundo pino pré-fabricado é semelhante em formato ao primeiro pino, mas será composto por fibra de vidro. O terceiro é um pino metálico pré-fabricado convencional, sem presença de flange. O quarto pino é semelhante ao terceiro pino em formato, mas será composto por fibra de vidro. Foi aplicada sobre os modelos uma mesma força estática média de 100 N com uma angulação de 135 graus ao longo eixo do dente no centro da face palatina do modelo, com o objetivo de simular a carga mastigatória e obter a distribuição das tensões. A avaliação apresentou os resultados considerando os critérios de Von Mises e tensões máximas principais. Os resultados mostraram que os pinos metálicos customizados resultaram em menores tensões à dentina e à estrutura coronária quando comparados aos pinos convencionais, e que ambos os pinos metálicos apresentaram menores tensões à estrutura coronária se comparados aos pinos em fibra de vidro. Em relação à estrutura dentinária, os pinos metálicos e os pinos em fibra de vidro apresentaram resultados semelhantes quanto à distribuição de tensões. Os modelos em fibra de vidro apresentaram resultados semelhantes em ambas as avaliações. Conclui-se que os modelos customizados foram superiores aos convencionais quando compostos pela liga metálica, mas semelhantes quando compostos por fibra de vidro. / Endodontically treated teeth commonly require a post to provide retention and support to the restorative process. The aim of this study was to compare the efficiency of the distribution stresses of different models of posts through the finite element method. A three-dimensional finite element model was developed to represent an endodontically treated maxillary central incisor restored with a ceramic crown, and four different types of prefabricated posts (two conventional and two customized models) have been inserted in that model and compared regarding the distribution of the stresses to which they were subjected. The four posts differ in size and material composition. The first is a custom metal prefabricated post relating to a patent, with anatomical coronal portion (with curvatures and format similar to the anatomical crown) and threaded flange. The second prefabricated post is similar in format to the first post, but is composed of fiberglass. The third is a conventional prefabricated metal post without the flange. The fourth post is similar to the third in format, but is composed of fiberglass. It was applied on the models the same average static occlusal force of 100N with an angle of 135 degrees to the tooth long axis in the palatal surface of the crown, with an objective of simulate the masticatory load and obtain the stress distribution. The evaluation presented the results considering the Von Mises and Maximum principal stress criteria. The results showed that the customized metal posts resulted in lower stresses to dentin and coronal tooth structure when compared to conventional posts, and both metallic posts had lower stresses in the coronal portion structure compared to glass fiber posts. Regarding the dentinal structure, metal posts and fiberglass posts showed similar results of stresses. The fiberglass models showed similar results in both evaluations. We conclude that the custom models were superior to conventional posts when composed by metal, but similar when composed of fiberglass.
15

Influência da contração de sinterização na adaptação de copings de Y-TZP: Efeito na distribuição de tensões / Influence of Sintering Shrinkage on the Fit of Y-TZP Copings: Effect on Stress Distribuition

Rezende, Carlos Eduardo Edwards 07 July 2015 (has links)
A longevidade das coroas cerâmicas depende, entre outros fatores, de sua adaptação ao pilar, bem como da distribuição das tensões nas mesmas. Não há um consenso sobre a melhor adaptação dos copings de zircônia feitos em CAD/CAM em relação aos métodos convencionais, podendo haver uma influência da contração de sinterização sobre esta. O presente estudo avaliou as alterações dimensionais decorrentes do processo de sinterização em três diferentes marcas comerciais de blocos de zircônia, relacionando-as com a adaptação de copings confeccionados por um sistema CAD/CAM, além de avaliar como a adaptação de tais copings poderia impactar na distribuição de tensões em coroas cerâmicas bi-camadas com estrutura de zircônia. A contração de sinterização das três marcas comerciais de zircônia foi obtida experimentalmente a partir da mensuração de espécimes geométricos. Trinta e seis copings de zircônia confeccionados por CAD/CAM foram divididos em três grupos (n=12): ZMAX a partir de blocos de IPS E.max ZirCad (Ivoclar Vivadent; Liechtenstein); ZYZ blocos de InCeram YZ (Vita Zahnfabrik; Alemanha) e; ZMC zircônia de manufatura controlada (Zirklein/Biodinâmica; Brasil). Os copings foram escaneados em micro-CT antes a após a sinterização para que as alterações dimensionais decorrentes do processo de sinterização fossem obtidas a partir da mensuração de cortes específicos. Os dados das alterações dimensionais obtidos para os espécimes geométricos e para os copings foram confrontados com as taxas de contração de sinterização informadas pelos fabricantes dos blocos de zircônia. Os copings sinterizados foram assentados sobre um pilar de zircônia e levados ao micro-CT para averiguação da adaptação interna e marginal dos mesmos. As mensurações foram realizadas pelo software ImageJ em 33 pontos diferentes. Os dados da adaptação possibilitaram a comparação estatística (p0,05) entre marcas comerciais e locais de mensuração, bem como a comparação entre a adaptação obtida experimentalmente e àquela determinada no software CAD/CAM para confecção dos copings. As imagens de micro-CT dos copings com menor e maior espaçamento foram utilizadas para a construção de modelos de elemento finito tridimensionais visando avaliar a distribuição de tensões em função do espaçamento coping/pilar na região oclusal. A contração de sinterização obtida para os espécimes geométricos foi 21,59±1,14%; 20,63±0,96% e 20,73±0,92% para os grupos ZMAX, ZYZ e ZMC, respectivamente. Todos os grupos apresentaram diferença estatística entre a taxa de contração do fabricante e a obtida experimentalmente. A análise das alterações dimensionais dos copings demonstrou incompatibilidade entre a taxa de contração ocorrida nos copings e àquela informada pelos fabricantes dos grupos ZMAX e ZMC. Também houve diferença entre a taxa de contração dos espécimes geométricos e a dos copings para todos os grupos estudados. Não houve uniformidade de contração de sinterização das paredes dos copings. Não houve diferença estatística entre os grupos para a adaptação marginal, havendo diferença apenas para a adaptação interna e entre as diferentes regiões mensuradas, havendo maior espaçamento na região oclusal. Considerando as diferentes faces axiais do copings, houve maior espaçamento na região vestibular. A comparação entre a adaptação obtida e àquela determinada pelo sistema CAD/CAM demonstrou diferença estatística em determinadas regiões mensuradas para todos os grupos. A avaliação da distribuição de tensões pelo método de elementos finitos demonstrou maior concentração de tensão no modelo com maior espaçamento entre copings e pilar na porção oclusal. Concluiu-se que não houve uniformidade na contração de sinterização, a marca comercial dos blocos de zircônia influenciou na adaptação, os parâmetros de espaçamento copings/pilar determinados no sistema CAD/CAM não foram obtidos na prática e, um maior espaçamento interno entre coping e pilar na região oclusal resultou em maior concentração de tensões na coroa cerâmica. / The longevity of ceramic crowns depends, among other factors, on its fit and the stress distribution. There is no consensus regarding the better fitting of zirconia CAD/CAM made crowns over conventional methods and may be an influence of zirconia sintering shrinkage on the abutment/coping spacing. This study aimed at evaluating the dimensional changes from sintering process of three zirconia blocks trademarks, relating them to the fit of CAD / CAM made zirconia copings, and to evaluate how the fit of such copings could impact on the stress distribution in bilayered Y-TZP based ceramic crowns. The sintering shrinkage of the three trademarks of zirconia was obtained experimentally from the measurement of geometric specimens. Thirty-six zirconia copings made by CAD / CAM were equally divided into three groups (n = 12): ZMAX - from blocks of IPS e.max ZirCAD (Ivoclar Vivadent, Liechtenstein); ZYZ - InCeram YZ blocks (Vita Zahnfabrik, Germany) and; ZMC - controlled manufacturing zirconia (Zirklein/Biodinamica, Brazil). The copings were scanned in micro-CT before and after the sintering so that dimensional changes from the sintering process were obtained from measurements taken from specific slices. Data from dimensional changes obtained for the geometric specimens and for the copings were faced with the sintering shrinkage rates reported by the manufacturers of zirconia blanks. The sintered copings were settled on a zirconia abutment and taken to the micro-CT scanner to evaluate its marginal and internal fit. Thirty three different points were measured using the Image J software. The data enabled the statistical comparison (p 0,05) between trademarks and measurement sites, as well as the comparison between the fit obtained experimentally with that stipulated by the CAD / CAM software. The micro-CT images of copings with smaller and larger cement space were used to build finite element models to evaluate stress distribution as a function of the abutment/coping fit in the occlusal aspect. The sintering shrinkage obtained for the geometric specimens was 21.59 ± 1.14%, 20.63 ± 0.96% and 20.73 ± 0.92% for ZMAX, ZYZ and ZMC groups, respectively. All groups showed statistical difference between the sintering shrinkage rate reported by the manufacturer and those obtained experimentally. The copings dimensional changes analysis showed incompatibility between the rates of shrinkage occurred in copings and to that reported by the manufacturers of ZMAX and ZMC groups. There was also a difference between the sintering shrinkage rate of the geometric specimens and the copings for all groups. In general, the sintering shrinkage of the walls of the copings showed no uniformity. Considering the adaptation of copings, there was no statistical difference between the groups for marginal fit, with differences only for internal fit and between the different regions measured. The thicker gap was found in the occlusal aspect. Considering the different axial aspects of the coping, the thicker spacing was found in the buccal region. The comparison between the fit obtained experimentally with that determined by the CAD/CAM system showed statistically significant differences in certain measured regions for all groups. The evaluation of stress distribution by finite element method showed higher stress concentration in the model with thicker cement space on the occlusal aspect. It was concluded that the sintering shrinkage did not occur uniformly; the adaptation of copings differed from a trademark to another; the obtained fitting did not achieve parameters determined in the CAD / CAM system; and a higher internal spacing between coping and abutment in the occlusal aspect resulted in higher stress concentration in the ceramic bi-layered crowns.
16

"Influência das ciclagens térmica, mecânica e de pH na resistência de união de sistemas adesivos à dentina de dentes decíduos" / Thermal, mechanical load and pH cycling influence on adhesive systems bond strength to primary dentin.

Rocha, Rachel de Oliveira 16 December 2004 (has links)
Nesta pesquisa foi realizada a avaliação da influência das ciclagens térmica, mecânica e de pH na resistência de união de sistemas adesivos à dentina de dentes decíduos. Para tal, cavidades oclusais foram preparadas em 80 molares decíduos e restauradas com os sistemas adesivos Single Bond e Clearfil SE Bond e resina composta Z100. Os dentes restaurados com cada um dos sistemas adesivos foram divididos em oito grupos (n= 5), de acordo com as condições de tratamento: ciclagem térmica (2000 ciclos, 5°C e 55°C), ciclagem de pH (10 ciclos, 8 horas de imersão em solução desmineralizadora e 16 em solução remineralizadora), ciclagem mecânica (100.000 ciclos, 8 kg), térmica/pH, térmica/mecânica, pH/mecânica e térmica/pH/mecânica, além do grupo controle. Os dentes foram seccionados perpendicularmente à interface de união e foram obtidos espécimes com área de superfície aderida com cerca de 0,8 mm 2 . Os espécimes foram submetidos ao teste de microtração e à análise do padrão de fratura em microscopia eletrônica de varredura. Os valores obtidos, expressos em MPa, foram submetidos à Análise de Variância (p < 0,05). Não foram encontradas diferenças estatísticas significantes na comparação entre os sistemas adesivos avaliados nem para os grupos submetidos à aplicação dos estresses térmico, mecânico e térmico/pH. Os demais grupos apresentaram valores de resistência de união inferiores àqueles obtidos pelo grupo controle (p < 0,05) Fraturas do tipo adesiva/mista foram as mais prevalentes (95,9%). A resistência de união dos sistemas adesivos avaliados é negativamente influenciada pela aplicação combinada das tensões com naturezas distintas. / The influence of thermal, mechanical load and pH cycling on adhesive systems bond strength to primary dentin was evaluated. Occlusal cavities in 80 primary molars were prepared with diamond bur and restored with Single Bond and Clearfil SE Bond adhesive systems and Z100 composite. Teeth restored with each adhesive system were shared into eight groups according treatment condition: thermal cycling (2000 cycle, 5°C and 55°C), pH cycling (10 cycles, demineralization solution immersion to 8 hours and 16 hours in remineralization solution), mechanical load cycling (100.000 cycles, 8kg), thermal/pH, thermal/mechanical load, pH/mechanical load and thermal/pH/mechanical load, besides control groups. The teeth were transversally sectioned in two axis rendering 0,8mm 2 stick shaped specimen. Sticks were then submitted to microtensile bond testing with a crosshead speed of 1mm/min. Fracture analysis was performed by scanning electron microscopy. Bond strength means expressed in MPa were submitted to two-wav ANOVA (p<0.05). No statistically significant differences were found between the adhesive systems nor to thermal, mechanical load and thermal/pH stresses groups. Lower bond strength values were found to other groups compared to control (p<0.05). Adhesive/mixed failures were prevalent (95.9%). Bond strengths of evaluated adhesive systems were negatively influenced by distinct tension application.
17

Avaliação do nível de inserção óssea do dente suporte em prótese parcial removível mandibular classe I associada a implante osseointegrado : análise pelo método dos elementos finitos /

Verri, Fellippo Ramos. January 2006 (has links)
Resumo: A colocação de PPR de extremidade livre no arco inferior é uma das mais complexas dentro da área protética. A associação desta com implantes na região distal tem melhorado biomecanicamente seu funcionamento. Porém, existem poucos estudos a respeito desta associação levando em consideração o nível de inserção óssea do dente suporte. Assim, o objetivo desta pesquisa foi avaliar, por meio do método dos elementos finitos bidimensional, a distribuição de tensão nas estruturas de suporte de uma PPREL, associada a um implante osseointegrado de 10,0 x 3,75 mm (Sistema Branemark), próximo ao dente suporte, com diferentes níveis de inserção óssea (íntegro e 1/2 da raiz) e com diferentes tipos de conexão entre a PPR e o dente suporte (apoio incisal e placa distal). Para o estudo, foram confeccionados 8 modelos mandibulares, de extremo livre, com a presença apenas do dente 33, sendo: MA - PPREL convencional, apoio incisal distal, inserção íntegra; MB - idem ao MA, mas utilizando placa distal; MC - idem ao MA, com implante de 3,75 x 10,0 mm e sistema ERA associado; MD - idem ao MC, mas utilizando placa distal; ME - idem ao MA, mas com perda de inserção de 1/2 da raiz; MF - idem ao MB, mas com perda de inserção de 1/2 da raiz; MG - idem ao MC, mas com perda de inserção de 1/2 da raiz; MH - idem ao MD, mas com perda de inserção de 1/2 da raiz. Com o auxilio do programa ANSYS 9.0, os modelos foram carregados com forças verticais de 50 N em cada ponta de cúspide. Os resultados foram obtidos pelos mapas de deslocamento e de tensão de von Mises e mostraram que o implante favorece a associação da forma descrita, que a placa possibilita um maior alívio e menor deslocamento do dente suporte, e que a perda do periodonto de suporte prejudica o prognóstico da prótese. / Abstract: The rehabilitation with distal extension RPDA is very complex in the prosthetic area and the association with implants had improving its work biomechanical. However, there is little studies about this type of association and no study about the lost of insertion was encountered by FEA. So, the aim of this study was to evaluate, by FEA 2-D, the tension distribution in support structures of a DERPD associated with a osseointegrated implant of 10,0 x 3,75 mm (Branemark System), near to support tooth, with different levels of bone insertion (no lost and 1/2 of root) and with different type of connection between the DERPD and de support tooth (incisal rest and distal plate). For the study, 8 distal extension mandibular models were made, with the presence of tooth 33, presenting: MA - conventional DERPD, incisal rest, no bone lost; MB - like MA, but with distal plate; MC - like MA, but with implanto of 3,75 x 10,0 mm and ERA system associated; MD - like MC, but with distal plate; ME - like MA, but with bone lost of 1/2 of root; MF - like MB, but with bone lost of 1/2 of root; MG - like MC, but with bone lost of 1/2 of root; MH - like MD, but with bone lost of 1/2 of root. By mean of program of FEA ANSYS 9.0, the models were carried with axial forces of 50 N in each cusp tip. The results were obtained by dislodgement maps and von Mises tension maps and shown that the implant was benefit to association by the study, and the plate decreased the tension and the dislodgement of the support tooth, and the bone lost was prejudicial to prognostic of this type of prosthesis. By this methodology, was possible to conclude that: the introduction of an osseointegrated implant with ERA system used like this study decrease the dislodgement of above structures in all models. / Orientador: Eduardo Pizza Pellizzer / Coorientador: João Antônio Pereira / Banca: Marcelo Coelho Goiato / Banca: Mário Alexandre Coelho Sinhoreti / Banca: Humberto Gennari Filho / Banca: Dalva Cruz Laganá / Doutor
18

"Influência das ciclagens térmica, mecânica e de pH na resistência de união de sistemas adesivos à dentina de dentes decíduos" / Thermal, mechanical load and pH cycling influence on adhesive systems bond strength to primary dentin.

Rachel de Oliveira Rocha 16 December 2004 (has links)
Nesta pesquisa foi realizada a avaliação da influência das ciclagens térmica, mecânica e de pH na resistência de união de sistemas adesivos à dentina de dentes decíduos. Para tal, cavidades oclusais foram preparadas em 80 molares decíduos e restauradas com os sistemas adesivos Single Bond e Clearfil SE Bond e resina composta Z100. Os dentes restaurados com cada um dos sistemas adesivos foram divididos em oito grupos (n= 5), de acordo com as condições de tratamento: ciclagem térmica (2000 ciclos, 5°C e 55°C), ciclagem de pH (10 ciclos, 8 horas de imersão em solução desmineralizadora e 16 em solução remineralizadora), ciclagem mecânica (100.000 ciclos, 8 kg), térmica/pH, térmica/mecânica, pH/mecânica e térmica/pH/mecânica, além do grupo controle. Os dentes foram seccionados perpendicularmente à interface de união e foram obtidos espécimes com área de superfície aderida com cerca de 0,8 mm 2 . Os espécimes foram submetidos ao teste de microtração e à análise do padrão de fratura em microscopia eletrônica de varredura. Os valores obtidos, expressos em MPa, foram submetidos à Análise de Variância (p < 0,05). Não foram encontradas diferenças estatísticas significantes na comparação entre os sistemas adesivos avaliados nem para os grupos submetidos à aplicação dos estresses térmico, mecânico e térmico/pH. Os demais grupos apresentaram valores de resistência de união inferiores àqueles obtidos pelo grupo controle (p < 0,05) Fraturas do tipo adesiva/mista foram as mais prevalentes (95,9%). A resistência de união dos sistemas adesivos avaliados é negativamente influenciada pela aplicação combinada das tensões com naturezas distintas. / The influence of thermal, mechanical load and pH cycling on adhesive systems bond strength to primary dentin was evaluated. Occlusal cavities in 80 primary molars were prepared with diamond bur and restored with Single Bond and Clearfil SE Bond adhesive systems and Z100 composite. Teeth restored with each adhesive system were shared into eight groups according treatment condition: thermal cycling (2000 cycle, 5°C and 55°C), pH cycling (10 cycles, demineralization solution immersion to 8 hours and 16 hours in remineralization solution), mechanical load cycling (100.000 cycles, 8kg), thermal/pH, thermal/mechanical load, pH/mechanical load and thermal/pH/mechanical load, besides control groups. The teeth were transversally sectioned in two axis rendering 0,8mm 2 stick shaped specimen. Sticks were then submitted to microtensile bond testing with a crosshead speed of 1mm/min. Fracture analysis was performed by scanning electron microscopy. Bond strength means expressed in MPa were submitted to two-wav ANOVA (p<0.05). No statistically significant differences were found between the adhesive systems nor to thermal, mechanical load and thermal/pH stresses groups. Lower bond strength values were found to other groups compared to control (p<0.05). Adhesive/mixed failures were prevalent (95.9%). Bond strengths of evaluated adhesive systems were negatively influenced by distinct tension application.
19

Análise da distribuição das tensões em maxila submetida à expansão cirurgicamente assistida com aparelho ósseo-suportado / Analysis of the distribution of maxillary stresses submitted to surgically assisted maxillary expansion with a bone-supported device

Victor Tieghi Neto 22 June 2017 (has links)
A expansão de maxila cirurgicamente assistida (EMCA) é a modalidade de tratamento que tem como objetivo romper as regiões de reforço maxilar permitindo seu movimento expansivo gradativamente. Tal movimento pode ser realizado às custas de aparelhos dento-suportado, dento-muco-suportado, implanto-suportados ou ósseo-suportado. Os efeitos produzidos pelo tratamento vão desde alterações esqueléticas (aumento da base, cavidade e do espaço aéreo nasais) até inclinações dentárias (principalmente nos dentes de suporte do aparelho expansor), dentre outras. O objetivo desta pesquisa foi avaliar, por meio do Método de Elementos Finitos (MEF), a distribuição das tensões produzidas pela EMCA nas estruturas maxilares utilizando-se aparelho expansor ósseo-suportado. Material e métodos: Foi confeccionado um modelo tridimensional de maxila para simulação da EMCA com osteotomia tipo LeFort I descendente sem degrau, com disjunção pterigomaxilar utilizando um modelo de aparelho ósseo-suportado para o teste com a simulação de abertura de 1mm. Os resultados mostraram maior abertura da maxila na região anterior de incisivos a pré-molar (1 mm) e em menor quantidade (0,6mm) na região de molares. A tensão máxima principal (TMXP) mostrou a concentração de tensões principalmente em toda face palatina da maxila de pré-molar ao túber maxilar. Pela face lateral, ficou mais evidente a TMXP nas região de osso alveolar posterior ao pré-molar, molares e túber, assim como na região de pilar zigomático acima da osteotomia. Pelo plano transversal foi possível observar a transmissão de tensões ao longo das estruturas ósseas mostrando pouca dissipação para as raízes do molar. Enquanto que as forças de compressão (Tensão Mínima Principal), evidenciadas pela tensão mínima principal, se manifestaram nas áreas de pilar zigomático e adjacentes as osteotomias, assim como na áreas de contato do apoio do aparelho com o osso palatino. Tensões de tração e compressão também foram evidenciadas na região de processo pterigoide. A análise de tensão de Von Mises mostrou que a parte que mais sofre estresse é a haste que liga o módulo do aparelho com a plataforma de apoio. Conclusão: Houve maior abertura da maxila na região anterior e as tensões resultantes de forças transmitidas ao osso alveolar dos dentes adjacentes ao aparelho, parecem não ser suficientes para deslocar os dentes. / Surgically assisted maxillary expansion (SARME) is the modality of treatment that aims to weaken the points of maxillary reinforcement allowing its gradual expansion. Such movement can be performed at the expense of dento-supported, dento-muco-supported, implanto-supported or bony-backed devices. The effects produced by the treatment range from skeletal changes (increase of nasal base, cavity and nasal air space) to dental inclinations (mainly in the supporting teeth of the expander apparatus), among others. The objective of the present research was to evaluate the distribution of stress produced by SARME in the maxillary structures using the bone-supported expander apparatus by the Finite Element Method (FEM). Material and methods: A three-dimensional hemi-maxilla model was simulated for SARME with a non-step descending LeFort I osteotomy with pterygomaxillary disjunction using a bone-supported device model for the 1mm aperture simulation test. The results showed a greater opening of the maxilla in the anterior region of the incisors to the premolar (1 mm) and smaller (0.6 mm) in the molar region. The principal maximal stress (TMXP) showed the concentration of the tension forces mainly in all the palatine face of the pre-molar maxilla to the maxillary tuft. Due to the lateral aspect, the TMXP was more evident in the posterior alveolar bone region, the molars and tuber, as well as in the epilating zygomatic region above the osteotomy. From the transversal plane, it was possible to observe the transmission of stress along the bony structures showing little dissipation for the roots of the molar. Meanwhile, the forces of compression (Principal Minimum Tension) evidenced by the principal minimal stress, were manifested in the areas of the zygomatic pillar adjacent to the osteotomies, as well as in the areas of contact of the support of the apparatus with the palatine bone. Tension and compression forces were also evidenced in the pterygoid process region. Von Mises\' stress analysis showed that the most stressed part is the rod connecting the device module to the support platform. Conclusion: There was a greater opening of the maxilla in the anterior region and the resulting forces of tension transmitted to the alveolar bone of the teeth adjacent to the appliance did not seem to be sufficient to displace the teeth.
20

Comparação da eficiência na distribuição de tensões de diferentes modelos de retentores intrarradiculares: uma análise de elementos finitos tridimensional / Efficiency comparison in stress distribution of different post types: a 3D finite element analysis

Eric Mayer dos Mayer-Santos 03 November 2016 (has links)
Elementos dentais endodonticamente tratados geralmente necessitam de retentores intrarradiculares para prover retenção e suporte ao processo restaurador. O objetivo deste estudo foi comparar a eficiência na distribuição de tensões de diferentes modelos de retentores intrarradiculares, através do método dos elementos finitos. Um modelo tridimensional de elementos finitos foi desenvolvido para representar um incisivo central superior endodonticamente tratado e restaurado com uma coroa total cerâmica, e quatro tipos diferentes de pinos pré-fabricados (dois convencionais, e dois modelos customizados) foram inseridos sob esse modelo e comparados quanto à distribuição das tensões às quais foram submetidos. Os quatro pinos diferem em formato e material de composição. O primeiro é um pino pré-fabricado metálico customizado referente à uma patente, com porção coronária anatômica (com curvaturas e formatos semelhantes à coroa anatômica) e flange rosqueável. O segundo pino pré-fabricado é semelhante em formato ao primeiro pino, mas será composto por fibra de vidro. O terceiro é um pino metálico pré-fabricado convencional, sem presença de flange. O quarto pino é semelhante ao terceiro pino em formato, mas será composto por fibra de vidro. Foi aplicada sobre os modelos uma mesma força estática média de 100 N com uma angulação de 135 graus ao longo eixo do dente no centro da face palatina do modelo, com o objetivo de simular a carga mastigatória e obter a distribuição das tensões. A avaliação apresentou os resultados considerando os critérios de Von Mises e tensões máximas principais. Os resultados mostraram que os pinos metálicos customizados resultaram em menores tensões à dentina e à estrutura coronária quando comparados aos pinos convencionais, e que ambos os pinos metálicos apresentaram menores tensões à estrutura coronária se comparados aos pinos em fibra de vidro. Em relação à estrutura dentinária, os pinos metálicos e os pinos em fibra de vidro apresentaram resultados semelhantes quanto à distribuição de tensões. Os modelos em fibra de vidro apresentaram resultados semelhantes em ambas as avaliações. Conclui-se que os modelos customizados foram superiores aos convencionais quando compostos pela liga metálica, mas semelhantes quando compostos por fibra de vidro. / Endodontically treated teeth commonly require a post to provide retention and support to the restorative process. The aim of this study was to compare the efficiency of the distribution stresses of different models of posts through the finite element method. A three-dimensional finite element model was developed to represent an endodontically treated maxillary central incisor restored with a ceramic crown, and four different types of prefabricated posts (two conventional and two customized models) have been inserted in that model and compared regarding the distribution of the stresses to which they were subjected. The four posts differ in size and material composition. The first is a custom metal prefabricated post relating to a patent, with anatomical coronal portion (with curvatures and format similar to the anatomical crown) and threaded flange. The second prefabricated post is similar in format to the first post, but is composed of fiberglass. The third is a conventional prefabricated metal post without the flange. The fourth post is similar to the third in format, but is composed of fiberglass. It was applied on the models the same average static occlusal force of 100N with an angle of 135 degrees to the tooth long axis in the palatal surface of the crown, with an objective of simulate the masticatory load and obtain the stress distribution. The evaluation presented the results considering the Von Mises and Maximum principal stress criteria. The results showed that the customized metal posts resulted in lower stresses to dentin and coronal tooth structure when compared to conventional posts, and both metallic posts had lower stresses in the coronal portion structure compared to glass fiber posts. Regarding the dentinal structure, metal posts and fiberglass posts showed similar results of stresses. The fiberglass models showed similar results in both evaluations. We conclude that the custom models were superior to conventional posts when composed by metal, but similar when composed of fiberglass.

Page generated in 0.1145 seconds