Análisis y diseño estructural de un tanque elevado de concreto armado con capacidad de 2000 m3

Coral Carrera, Kevin Mijail, Fernández Arana, Shelly Beatriz 01 August 2018 (has links)
Los tanques elevados para el almacenamiento de agua desempeñan un rol muy importante en los sistemas de distribución de agua. Es importante realizar un adecuado análisis y diseño sismoresistente debido a que el Perú se encuentra en una zona sísmica por la interacción de la placa de Nazca y la Sudamericana. En el Perú no se cuenta con normas necesarias ni específicas para el correcto análisis y diseño de este tipo de estructuras no convencionales. Por lo cual, además de la Norma de Diseño Sismoresistente (E.030) y Diseño de Concreto Armado (E.060) del Reglamento Nacional de Edificaciones, se usaron las Normas Internacionales Seismic Design of Liquid – Containing Concrete Structures and Commentary (ACI 350.3 – 06) y American Society of Civil Engineers (ASCE 7-05), así mismo, para el modelo dinámico de interacción del líquido con la estructura se usó el modelo propuesto por G.W.Housner. En este modelo la masa total del líquido se clasifica en Masa Impulsiva y Masa Convectiva. Para el modelamiento se usó el programa de elementos finitos SAP2000 Versión 18. Para el análisis dinámico se usó el mapa de isoaceleraciones espectrales con el cual se calculó un espectro de respuesta sísmico dando como resultado un periodo de T = 4.01s y una cortante de V = 1496.68 Ton-f. Para fines de cálculo se consideró la ubicación en la ciudad de Lima y el tipo de suelo rígido. Finalmente, se propone el uso de anillos deflectores en la cuba, las cuales estarán adosadas en la pared interna en forma de viga. Esta propuesta es un sistema de amortiguamiento sísmico que disminuye las fuerzas producidas por la masa del agua hasta en un 30%. La idealización de la propuesta, cálculos y resultados se verán con mayor detalle en la presente tesis. / Elevated water storage tanks constitute an important role in water distribution systems. It is important to conduct a proper analysis and earthquake resistant design, because Peru is in a seismic zone caused by the interaction of the Nazca plate and the South American plate. In Peru there are no adequate nor specific norms for the correct analysis and design of this type of unconventional structures. Therefore, in addition to the Sismo Resistant Design Standard (E.030) and Armed Concrete Design (E.060) of the National Building Regulations, the International Standards Seismic Design of Liquid Concrete Structures and Comments (ACI 350.3 - 06) and American Society of Civil Engineers (ASCE 7-05), likewise, for the dynamic model of interaction of the liquid with the structure the model proposed by GW Housner was used. In this model, the total mass of the liquid is classified as Impulsive Mass and Convective Mass. For modeling, the finite element program SAP2000 Version 18 is used. For the dynamic analysis, the map of spectral isoacelerations was used, with which a seismic response spectrum was calculated, resulting in a period of T = 4.01s and a shear of V = 1496.68 Ton-f. For the purposes of calculation, the location in the city of Lima and the type of rigid floor. Finally, it is proposed to use baffle rings in the tank, which are attached to the internal wall in the form of a beam. This proposal is a system of seismic damping that reduces the forces produced by the mass of water by up to 30%. The idealization of the proposal, calculations and results will be seen in greater detail in this thesis / Tesis
12

Evaluación estructural y ampliación de niveles para el cambio de uso de la casa del adulto mayor a centro comercial en el Distrito de La Molina

Mallaupoma Arias, Brayhan Ubaldo, Montenegro Callacna, Omar Kenny January 2015 (has links)
En la evaluación estructural y ampliación de niveles para el cambio de uso de la casa del adulto mayor a centro comercial en el distrito de la molina, se determina que tan factible puede ser darle un uso comercial a una casa del adulto mayor que con las modificaciones necesarias a nivel de estructura como la ampliación de la misma en 3 niveles, nos brinda un negocio potencialmente rentable, gracias a la zona comercial donde se encuentra ubicada avenida alameda del corregidor – Cuadra 5 y el área aproximada de 700m2. Por ello ,tenemos como objetivo general evaluar la estructura de una casa del adulto mayor para el cambio de uso a centro comercial en el distrito de La Molina y como consecuencia a la evaluación determinar si es factible ampliarlo en 3 niveles más con el fin de darle un mejor uso, acondicionándola como tiendas comerciales en todos sus niveles. La principal teoría utilizada para evaluar la estructura y ampliarla son el análisis sísmico estático y dinámico teniendo en cuenta las cargas puntuales y distribuidas de la estructura para el estático y el espectro de Pseudo-aceleraciones para el dinámico de acuerdo a la normatividad vigente, también el modelamiento estructural en el programa ETABS con el que mediante el análisis del programa nos proporcionara los desplazamiento en la estructura y con estos resultados de acuerdo a la norma sísmica vigente podremos determinar las distorsiones en cada nivel siendo estos valores para que cumpla con la norma menores a 0.07. El tipo de investigación utilizado es básico, cuantitativo, explicativo y el diseño es no experimental, transversal y descriptivo. Es prospectiva pues trata de un diseño sísmico donde trabajaremos con valores proporcionados por el programa. De los resultados que se calcularon tanto en la estructura original como en la ampliación se determinó que el cambio de uso para la estructura original teniendo en cuenta el retiro de las cargas adicionales y la ampliación es factible ya que ningún valor en las torsiones fueron mayores al 0.07 propuesto en la norma. In the structural evaluation and extension levels for the change of use of the house of the elderly to shopping center in the district of La Molina, it is determined to be feasible as a commercial use to give a house the elderly with amendments necessary level of structure and expanding the same into 3 levels, it offers a potentially profitable business, thanks to the commercial area where it is located mayor Avenue Mall - Cuadra 5 to the approximate area of 700m2. Therefore, we have as a general objective to evaluate the structure of a house of the elderly for change of use to a commercial center in the district of La Molina and consequently to determine the feasibility assessment extend over 3 levels more in order to give better use, renovating as commercial shops at all levels. The main theory used to evaluate the structure and expand are static and dynamic seismic analysis considering point loads and distributed structure for static and pseudo-acceleration spectrum for dynamic according to regulations, also the structural modeling in ETABS program that by analyzing the program we provide the shift in the structure and the results according to current seismic code can determine distortions at each level being these values to comply with the norm under 0.07. The research used is basic, quantitative and explanatory design is not experimental, transversal and descriptive. It is a prospective for seismic design where work with values provided by the program. From the results that were calculated in both the original structure and the extension was determined that change of use for the original structure considering the withdrawal of additional charges and the expansion it is feasible because no value was higher by twisting 0.07 proposed in the standard.
13

Comparativo de análisis estructural considerando interacción suelo - estructura (ISE) vs. empotrado, para un edificio de oficinas de 5 pisos, en la ciudad de Lima, con sistema dual, según la propuesta de norma E030-2014

Alfaro Quispe, Giuseppe Leoncio, Copello Muñante, Renatto Mauricio 31 December 2017 (has links)
Presenta el modelamiento desde el predimensionamiento de elementos hasta el cálculo de estructural para modelos con base rígida, base rígida con elementos agrietados e interacción suelo – estructura (ISE). Para ello se hace uso de un edificio de 5 pisos con sistema Dual, ubicado en San Isidro. En el desarrollo de los modelos se hace uso del programa ETABS, sin embargo, algunos cálculos se presentan manualmente para dar al lector la visión de cómo es el diseño analíticamente. Se buscó ser lo más detallado y minucioso posible en la presentación de la obtención de los coeficientes de rigidez que involucra el modelo con ISE, así mismo se presenta demostración teórica del modelo que rige dicho modelo, el cual es el modelo Barkan. Este modelo tiene una explicación extendida e histórica de cómo se originó. Con los modelos realizados se procedió a obtener las derivas, fuerzas y periodos a los que está sometido cada modelo. Donde con estos resultados se realiza una comparación y se realiza el diseño estructural para posteriormente ver diferencias económicas relacionadas al casco. Finalmente, se presenta el análisis de las diferencias observadas entre los tres modelos estudiados.
14

Evaluación y reforzamiento de dos edificios contiguos construidos en la década del 60 en el centro de Lima

Vega Pereda, Carlos Enrique 2013 March 1919 (has links)
En la actualidad, existen diversos edificios ubicados en el centro de Lima, con una antigüedad mayor a los 50 años aproximadamente. Varios de estos edificios están siendo remodelados para los proyectos del programa MI VIVIENDA. Sin embargo, en la mayoría de los casos no se está realizando un análisis que permita verificar si la estructura cumple con las normas actuales y si necesita ser reforzado. El tema de tesis que se desarrollará consiste en la evaluación y reforzamiento de dos edificios contiguos de 11 pisos construidos en la década del 60 en el centro de Lima; utilizando solo los planos de arquitectura, el cual contiene el levantamiento de las dimensiones estructurales. Se utilizarán los planos de Arquitectura pues al igual que la mayoría de edificaciones del centro de Lima, no se cuenta con los planos estructurales en la Municipalidad. Se utilizará planos de proyectos similares de la época, para evaluar el desarrollo de los proyectos en ese tiempo y deducir el tipo de refuerzo con el que cuenta la estructura que analizaremos. Posteriormente, se plantearán distintas alternativas de reforzamiento haciendo uso de elementos nuevos de concreto como la inclusión de placas, ensanchamiento de los elementos estructurales como vigas y columnas, elementos nuevos de acero como arriostres, así como el reforzamiento con fibra de carbono con mayor énfasis en el cortante de las vigas. Para el análisis de las distintas alternativas se utilizará el software ETABS8 Nonlinear el cual nos ayudará a determinar las ventajas y desventajas de las alternativas propuestas así como el cumplimiento de lo exigido por la norma sismorresistente en cuanto al análisis estático, análisis dinámico, los desplazamientos laterales de entrepisos, cálculo de la junta, etc. Una vez evaluadas las distintas alternativas se procederá a diseñar la más adecuada desde el punto de vista económico, su funcionalidad y seguridad, cumpliendo con todos los parámetros exigidos en la Norma de concreto armado y la Norma de diseño y sismorresistente. Por último, en función a los resultados de la investigación se concluirá en el desarrollo de una propuesta de guía metodológica para las edificaciones construi / Tesis
15

Aplicación de métodos de inspección y reparación en viviendas de albañileria confinada con presencia de daños en sus elementos estructurales provocado por un sismo

Chavez Huerta, Brian Francisco, Espíritu Castillejo, Martín Andree 24 October 2019 (has links)
Los sismos a través del tiempo han sido perjudiciales en el desarrollo de construcciones hechas por el hombre. Un sismo es un movimiento repentino del terreno producido por fuerzas que actúan en el interior del planeta; sus orígenes son numerosos pero el más importante son los choques entre las placas tectónicas. Respecto a las estructuras dañadas por el sismo, en la mayoría de los casos, son las viviendas familiares las que se ven perjudicadas en mayor medida, son muchas las causas, pero uno de los más importantes es la construcción de edificaciones de albañilería confinada realizadas sin ningún parámetro ingenieril (Hermosa, 2003). Por ello, cuando ocurre un sismo suele aparecer fallas en sus elementos estructurales, que en algunos casos no se le toma la debida importancia por el usuario, vale mencionar que este acto no es el correcto debido a que, si ocurriera un sismo de alta magnitud podría colapsar y como consecuencia se perderían vidas humanas. Por esta razón, a todos los profesionales dedicados al rubro de la construcción les es imprescindible contar con nociones de inspección de los daños estructurales y asimismo saber repararlas. En este documento se aprenderá las diferentes aplicaciones de métodos de inspección de fisuras en elementos estructurales tanto en columnas, vigas y muros, pero enfocado principalmente en el muro ya que, en esta técnica constructiva, el muro es el que soporta los esfuerzos, este análisis será de dos formas: Evaluación rápida y evaluación detallada. En la evaluación rápida, se determina rápidamente el riesgo o seguridad que representa la estructura; esta información será almacenada en una aplicación, el cual será la herramienta para la evaluación con el fin de determinar el nivel de seguridad de la vivienda, las cuales son seguridad total, habitable, cuidado e insegura, estableciendo de esta manera si la vivienda es habitable o no (Pinto y Torres, 2016). Finalmente, si la vivienda se encontrase en el nivel de seguridad de cuidado o insegura se pasará a una evaluación detallada; en esta evaluación se recomienda una inspección no mayor a 6 horas. En la evaluación detallada, se realiza una reevaluación de acuerdo a los niveles establecidos en la evaluación rápida, centrándose en los últimos niveles, cuidado e inseguro, respectivamente; se determinará las causas que originaron los daños, así como la magnitud de daños en los elementos estructurales a través de equipos de inspección, siendo algunos de ellos, el pacómetro y el comparador; para la posterior aplicación de diversos métodos de reparación. Finalmente, la reparación involucra la inyección de resina epoxi en grietas, reforzamiento con fibra de carbono, malla electrosoldada, entre otros. El éxito de la aplicación de estos métodos tiene como objetivo lograr disminuir el porcentaje de probabilidad de colapso y eliminar la pérdida de vidas humanas que se realizará mediante un modelamiento de la vivienda reparada la cual tendrá que cumplir con las normas de diseño sismorresistente. Como resultado de este modelamiento en Etabs se pudo comprobar que efectivamente tras la reparación a través de fibra de carbono y malla electrosoldada en los muros de albañilería confinada, la estructura es capaz de soportar sismos de igual o mayor magnitud. / Earthquakes over time have been detrimental in the development of man-made constructions. An earthquake is a sudden movement of the land produced by forces acting inside the planet; Its origins are numerous but the most important are the clashes between the tectonic plates. Regarding the structures damaged by the earthquake, in most cases, it is family homes that are harmed to a greater extent, there are many causes, but one of the most important is the construction of confined masonry buildings made without no engineering parameter (Hermosa, 2003). Therefore, when an earthquake occurs, failures usually appear in its structural elements, which in some cases do not take due importance by the user, it is worth mentioning that this act is not correct because, if a high magnitude earthquake occurs It could collapse and as a result human lives would be lost. For this reason, all professionals dedicated to the construction sector are essential to have notions of inspection of structural damage and also know how to repair them. In this document we will learn the different applications of methods of inspection of fissures in structural elements both in columns, beams and walls, but focused mainly on the wall since, in this construction technique, the wall is the one that supports the efforts, this analysis It will be in two ways: Rapid evaluation and detailed evaluation. In the rapid assessment, the risk or safety of the structure is quickly determined; This information will be stored in an application, which will be the tool for the evaluation in order to determine the level of security of the house, which are total, habitable, careful and insecure security, establishing in this way if the house is habitable or not (Pinto y Torres, 2016). Finally, if the house is at the level of care or insecurity, a detailed evaluation will be carried out; In this evaluation, an inspection of no more than 6 hours is recommended. In the detailed evaluation, a reassessment is carried out according to the levels established in the rapid evaluation, focusing on the last levels, careful and insecure, respectively; the causes that caused the damage will be determined, as well as the magnitude of damage to the structural elements through inspection equipment, some of them being the pacometer and the comparator; for the subsequent application of various repair methods. Finally, the repair involves the injection of epoxy resin in cracks, reinforcement with carbon fiber, welded mesh, among others. The success of the application of these methods aims to reduce the likelihood of collapse and eliminate the loss of human lives that will be done through a modeling of repaired housing which will have to comply with seismic-resistant design standards. As a result of this modeling in Etabs, it was found that after the repair through carbon fiber and welded mesh in the confined masonry walls, the structure is capable of withstanding earthquakes of equal or greater magnitude. / Tesis
16

Reforzamiento estructural para mejorar el nivel de desempeño del Hospital Santa Rosa, implementando el diseño apropiado de amortiguadores fluido viscoso

Cáceres Pérez, Gladys, Pichihua Alata, Natali Sheyla 10 June 2020 (has links)
Movimientos telúricos ocurridos en distintas partes del mundo han originado considerables pérdidas económicas y humanas. Es importante mencionar también que, durante estos últimos años, en los principales países desarrollados tales como Taiwán, Japón y Estados Unidos se ha venido implementando nuevas tecnologías para mejorar el desempeño en las estructuras frente a acciones sísmicas como son los sistemas de protección sísmica. Uno de estos avances son los disipadores de energía fluido viscoso cuya implementación muestra resultados óptimos para el incremento del amortiguamiento y reducción de desplazamientos laterales. Para cumplir con el objetivo principal de la investigación, se evaluó el diseño estructural del bloque A2 del Hospital Santa Rosa, una edificación esencial ubicada en el distrito de Pueblo Libre, Lima. Se realizó el modelo y análisis sísmico de la estructura existente, cuyos resultados muestras derivas ( ∆=5.98%o ) mayores al límite establecido en la Norma E.030 ( ∆=5%o ). Además, presenta efectos de columna corta que originan el agrietamiento de las unidades de albañilería, hecho que los hace vulnerables. Frente a los resultados presentados se realiza una nueva modelación y análisis sísmico del bloque en estudio, considerando como reforzamiento los disipadores de fluido viscoso. Para ello, se analiza nuevamente la estructura a través de un análisis tiempo historia tomando distintas consideraciones como el sismo de diseño y las propiedades de los disipadores fluido viscoso en donde las derivas máximas se han reducido de 5.98%o a 3.30 %o. Adicionalmente, se analiza la estructura con una técnica de reforzamiento tradicional como son las placas de concreto armado, con el objetivo de evaluar la viabilidad de la primera propuesta. Los resultados indican que, con un reforzamiento de muros de concreto se obtiene una deriva de ∆=3.36%o y ∆=3.30%o empleando los disipadores viscosos, lo cual demuestra la viabilidad de la propuesta en respuestas estructurales. / Telluric movements in different parts of the world have caused considerable economic and human losses. It is also important to mention that, in recent years, in the main developed countries such as Taiwan, Japan and the United States, new technologies have been implemented to improve the performance of structures against seismic actions such as seismic protection systems. One of these advances are the viscous fluid energy dissipators whose implementation shows optimal results for increasing damping and reducing displacement. In order to comply with the main objective of the research, the structural design of block A2 of the Santa Rosa Hospital, an essential building located in the Pueblo Libre district, Lima, was evaluated. The seismic analysis and model of the existing structure was carried out, whose results show drifts ( ∆=5.98%o ) greater than the limit established in Standard E.030 ( ∆=5%o ). In addition, it presents short column effects that cause cracking of the masonry units, a fact that makes them vulnerable. In front of the presented results, a new modeling and seismic analysis of the block under study is performed, considering viscous fluid dissipators as reinforcement. For this, the structure is analyzed again through a time-history analysis taking different considerations such as the design earthquake and the properties of the viscous fluid heatsinks where the maximum drifts have been reduced from 5.98%o to 3 .30%o Additionally, the structure is analyzed with a traditional reinforcement technique such as reinforced concrete plates, with the aim of evaluating the feasibility of the first proposal. The results indicate that, with a reinforcement of concrete walls, a drift of ∆=3.36%o and ∆=3.30 is obtained using viscous heatsinks, which demonstrates the viability of the proposal in structural responses. / Tesis
17

Análisis del comportamiento dinámico del agua en tanques apoyados rectangulares y cilíndricos bajo acción sísmica

Guillén Ascarza, Misael Enzo, Rojas Pérez, Alex Vladimir 04 September 2017 (has links)
La presente tesis tiene como objetivo analizar y comparar la repuesta sísmica de tanques rectangulares y circulares de concreto armado conteniendo agua y con el tanque apoyado sobre el suelo, con el fin de demostrar que las fuerzas del movimiento y amplitud de movimiento del agua sobre las paredes del tanque dan resultados menos conservadores cuando se usa en el análisis las ecuaciones de Navier-Stokes en vez del Método Simplificado de Housner. Se presenta una propuesta de tanque rectangular y otro circular para un volumen de diseño de 1000 m3 de agua para un tanque apoyado en un suelo intermedio ubicado en Lima. Se procede a calcular el cortante basal y momento mediante el método de Housner con las especificaciones del ACI 350-01 y la norma Peruana de diseño sismoresitente E.030-2006. El cortante basal y momento se calculan con la ayuda de un modelo mecánico equivalente basado en las ecuaciones de Navier-Stokes para una, dos y tres masas oscilatorias modeladas en el software SAP 2000. Luego se encuentra que con el modelo mecánico equivalente basado en las ecuaciones de Navier- Stokes se obtiene un 10% y 15% menos de cortante y momento que con el modelo Housner. Asimismo, se procede a evaluar la amplitud del oleaje con las ecuaciones originales de Housner y ACI-350-01 y a su vez, resolviendo las ecuaciones de Navier-Stokes para varios modos de vibración. Luego se encuentra que la amplitud del oleaje máximo determinado en base a las ecuaciones de movimiento de Navier-Stokes son más conservardoras que la amplitud calculada por las especificaciones del ACI 350.3-01 y el Metodo de Houser. Sin embargo, el valor no sobrepasa del 20% por encima de lo propuesto por el ACI, para ambos tipos de tanques / The present thesis aims to analyze and compare the seismic response of rectangular and circular tanks of reinforced concrete containing water and with the tank resting on the ground, in order to demonstrate that the forces of movement and the amplitude of the movement of water over the tank walls give less conservative results when the Navier-Stokes equations are used in the analysis instead of the Housner's Simplified Method. We present a proposal for a rectangular tank and a circular one for a design volume of 1000 m3 of water for a tank supported on an intermediate ground located in Lima. We proceed to calculate the basal and momentum cut by the Housner method with the specifications of ACI 350-01 and the Peruvian standard of seismic design E.030-2006. The basal shear and momentum are calculated with the help of a mechanical model based on the Navier-Stokes equations for one, two and three oscillatory models modeled on the SAP 2000 software. It then encounters the equivalent mechanical model based on equations of Navier-Stokes is 10% and 15% less shear and moment than with the Housner model. Also, test the amplitude of the wave with the original equations of Housner and ACI-350-01 and turn, solving the Navier-Stokes equations for various modes of vibration. Then it encounters the amplitude of the wave at the base of the Navier-Stokes equations of motion are more conservative than the amplitude calculated by the specifications of ACI 350.3-01 and the Houser Method. However, the value does not exceed 20% above that proposed by the ACI, for both types of tanks. / Tesis
18

Análisis Comparativo del Comportamiento Sísmico Dinámico del diseño normativo sismo-resistente de un sistema dual frente al modelo con aisladores elastoméricos de alto amortiguamiento (HDR) de un sistema aporticado, del Edificio de Oficinas Schell de seis pisos ubicado en la Provincia de Lima – Perú

Carmona Ramírez, Pedro, Rosas Fetta, Angello Jesús 2015 December 1921 (has links)
El objetivo principal es realizar un análisis comparativo y un diseño estructural utilizando aisladores sísmicos en la base (elastoméricos de alto amortiguamiento HDR) para estudiar el comportamiento estructural de un edificio de oficinas contra un sistema dual bajo un criterio normativo sismo-resistente, mediante un modelo sísmico según el programa de modelación estructural SAP2000, el cual proporcionará resultados necesarios para elegir el mejor modelo ante un evento sísmico. Inicialmente se recopilará información acerca de los métodos para la mejora del comportamiento sísmico. Se realizará un análisis sísmico dinámico utilizando un espectro de respuesta de aceleración según tipo de suelo. Luego, Se colocará el aislador HDR (Aisladores Elastoméricos de Alto Amortiguamiento) en la base de la estructura. Además, se realizará el modelamiento adecuado con el programa de modelación estructural SAP2000. Por último, se describe y compara los resultados obtenidos en los diferentes análisis y modelamiento. / Tesis
19

Análisis y diseño sísmico por desempeño de los bloques A, B y C del departamento de ordenamiento territorial y construcción de la UNALM según el código ATC-40 / Analysis and seismic design for performance of block A, B and C of the department of land use and construction of the UNALM according to the ATC-40 code

Gutierrez Yaya, Luis Fernando, Lezama Romero, Erwin Ibraim 03 August 2020 (has links)
La presente tesis trata de demostrar que la norma peruana de diseño sismoresitente debe evolucionar y tener mayores exigencias en instituciones de uso esencial, por lo que se evaluará los daños obtenidos mediante un diseño con la Norma E-030 y el ACT-40 ante diferentes niveles sísmicos a los bloques A, B y C de la facultad de Ingeniería Agrícola de la UNALM, para ello en el primer capítulo se explicará la evolución de la norma de diseño sismoresistente E-030 y de algunas normas internacionales como el ATC. En el capítulo 2, se dará a conocer la clasificación de los parámetros de desempeño que tienen las estructuras según el código ATC-40 para el diseño por desempeño. En el siguiente capítulo, se presentarán los bloques diseñados. Mientras que en el capítulo 4 y 5 se realizará un análisis y diseño estructural con la Norma E030 y el ATC-40, respectivamente. Finalmente, en el capítulo 6 Y 7 se presentará una comparación entre los niveles de daños producidos en los elementos mediante el monitoreo de las deformaciones (giros y desplazamientos) comprándolas con los límites de aceptación de las normas mencionadas anteriormente. / This thesis tries to demonstrate that the Peruvian standard of earthquake-resistant design must evolve and have greater demands in institutions of essential use, so that the damages obtained through a design with Standard E-030 and ACT-40 will be evaluated at different levels Seismic blocks A, B and C of the Faculty of Agricultural Engineering of the UNALM, for this in the first chapter the evolution of the E-030 earthquake resistant design standard and some international standards such as the ATC will be explained. In chapter 2, the classification of performance parameters that structures have according to the ATC-40 code for performance design will be announced. In the next chapter, the designed blocks will be presented. While in Chapter 4 and 5 an analysis and structural design will be carried out with Standard E030 and ATC-40, respectively. Finally, in chapter 6 and 7 a comparison will be presented between the levels of damage caused to the elements by monitoring the deformations (turns and displacements) by buying them with the limits of acceptance of the aforementioned standards. / Tesis
20

Análisis comparativo de la respuesta sísmica de una edificación esencial y otra común utilizando espectros de sitio y análisis dinámico modal espectral compatibilizando el perfil de suelo y el factor de amplificación sísmica según normas E.030 y NCH433, en la provincia del Callao / Comparative analysis of the seismic response of an essential building and a common one using site spectra and dynamic modal spectral analysis making compatible the soil profile and the amplification factor of the seismic standards E.030 and NCH433, in Callao

Huaripata Escobal, Fernando Rafael, Torres Mera, Jose Franklin 06 July 2021 (has links)
Las edificaciones construidas sobre suelo costero, ubicados sobre el cinturón del fuego presentan un alto riesgo sísmico, ya que sobre estas existen condiciones de suelo desfavorables y en otros casos subducción de placas. Esto ha conllevado a que los países ubicados en estas zonas desarrollen normativas sísmicas que permitan el diseño adecuado de obras de ingeniería; sin embargo, diversos reglamentos presentan distintas consideraciones para el diseño como la utilización de los parámetros que permiten estandarizar el diseño que muchas veces no presentan las mismas respuestas sísmicas del comportamiento dinámico real del suelo. Por ello, la presente investigación propone evaluar la respuesta sísmica de dos edificaciones, una esencial y otra común, con un análisis utilizando espectros de sitio, un análisis dinámico modal espectral y adicionalmente un análisis tiempo-historia teniendo consideraciones de tipos de suelo y utilización de distintos parámetros sísmicos de normas sudamericanas. El principal resultado es que la respuesta sísmica por análisis con espectros de sitio (ES) es mayor en comparación con el análisis dinámico modal espectral según la magnitud de los sismos y la tipología de suelos. / The buildings built on coastal soil, located on the fire belt present a high seismic risk, since there are unfavorable soil conditions and in other cases plate subduction. This has led to countries located in these areas developing seismic regulations that allow the proper design of engineering works; however, various regulations present different considerations for the design, such as the use of parameters that allow standardizing the design that often does not present the same seismic responses of the real dynamic behavior of the soil. Therefore, the present research proposes to evaluate the seismic response of two buildings, one essential and the other common, with an analysis using site spectra, a dynamic spectral modal analysis and additionally a time-history analysis taking into account soil types and use of different seismic parameters of South American standards. The main result is that the seismic response by analysis with site spectra (ES) is greater compared to the dynamic spectral modal analysis according to the magnitude of the earthquakes and the type of soil / Tesis