• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 33
  • 4
  • 1
  • Tagged with
  • 38
  • 38
  • 32
  • 30
  • 16
  • 14
  • 13
  • 10
  • 10
  • 10
  • 10
  • 9
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Tratamento de efluentes de branqueamento de polpa celulósica em reator anaeróbio seguido de processo oxidativo avançado / Treatment of bleach plant effluent in anaerobic reactor and advanced oxidation processes

Adela Tatiana Rodriguez Chaparro 07 January 2010 (has links)
A remoção da matéria orgânica biodegradável e não biodegradável presente em efluentes de branqueamento de polpa celulósica kraft foi investigado utilizando processos biológicos anaeróbios seguidos de processos de oxidação avançada (POA) baseados em ozônio. Os experimentos foram realizados utilizando-se efluentes da planta de branqueamento de polpa celulósica kraft de duas indústrias. O reator anaeróbio horizontal de leito fixo (RAHLF) em escala de bancada operou em regime contínuo durante 418 dias e o efluente biotratado era submetido à oxidação avançada aplicando ozônio e ozônio/UV em regime de batelada. Os resultados demonstraram que a sequência de tratamento Anaeróbio + POA baseados em ozônio, favoreceu satisfatoriamente a remoção da matéria orgânica (biodegradável e não biodegradável) presente no efluente de branqueamento de polpa celulósica Kraft, medida como DQO, COd, AOX, lignina solúvel em ácido (LSA), e valores da absorbância em comprimentos de onda na região UV-VIS do espectro (UV215, UV254, UV280, VIS346).Verificou-se com testes de ecotoxicologia aquática utilizando Daphnia similis e Ceriodaphnia sp, que os efluentes de branqueamento são tóxicos aos organismos aquáticos. Do mesmo modo, ensaios de genotoxicidade utilizando células da região meristemática da raiz do Allium cepa L (cebola comum), revelaram que esses efluentes apresentam atividade mutagênica, genotoxica e citotóxica. No entanto, observou-se que tantos os efeitos tóxicos bem como os genotóxicos e mutagênicos, estão estreitamente relacionados com o conteúdo da matéria orgânica biodegradável, uma vez que, após o processo anaeróbio apresentaram-se remoções estatisticamente significativas para todos os efeitos já mencionados (até 100%) com concomitante remoção da demanda química de oxigênio (até 55 \'+ OU -\' 9%) e do carbono orgânico dissolvido (até 57 \'+ OU -\' 7%). Ainda, verificou-se que após a aplicação do ozônio/UV, embora, o teste de biodegradabilidade aeróbia pelo método de Zahn Wellens revelasse que esse efluente era o mais biodegradável, tanto a toxicidade crônica como a genotoxicidade e a citotoxicidade resultaram estatisticamente significativas em relação ao controle negativo. Este resultado indica que, efetivamente a matéria orgânica biodegradável deset tipo de efluentes pode se relacionar com a presença de efeitos tóxicos e genotóxicos. Tal fato não foi verificado no caso do tratamento apenas com ozônio. / Removal of biodegradable and non biodegradable organic matter present in kraft pulp mill effluent was investigated integrating an anaerobic biological process and advanced oxidation processes based on ozone. The experiments were carried out using two different Brazilian pulp mill. The bench scale Horizontal Anaerobic Immobilized Sludge Bioreactor (HAIS) was operated during 418 days; subsequently the biotreated effluent was oxidized applying ozone and ozone/UV in batch regime. The results show that the treatment sequence, anaerobic process + advanced oxidation processes based on ozone, results in removal of both organic matter biodegradable and non-biodegradable measured as chemical oxidation demand (COD), dissolved organic carbon (COd), adsorbable organic halides (AOX), acid soluble lignin (ASL) and absorbance values in the UV-VIS spectrum (i.e. UV215, UV205, UV280, VIS346). Ecotoxicological tests using Daphnia similis and Ceriodaphnia sp. confirmed that bleached kraft pulp mill is toxic to aquatic organisms. Moreover, genotoxicity tests with meristematic cells of Allium cepa (i.e. common onion) roots show that this type of effluent results in mutagenic, genotoxicological and citotoxicological activities. It is to be highlighted however that both toxicological and genotoxicological effects are closely related to the biodegradable organic matter, thus, after the anaerobic processes the removal of these effects occur, concomitant to reductions is chemical oxygen demand (55 \'+ OU -\' 9%) and dissolved organic carbon (57 \'+ OU -\' 7%). It was also observed that after ozone/UV application, both the chronic toxicity and genotoxicity activity were statically significant if compared with the negative control, although the Zahn Wellens test revealed that this effluent had the highest biodegradability. These results confirmed that biodegradable organic matter could be related with toxic and genotoxic effects. In the case of ozone application alone this behavior was not observed.
32

Degradação de benzeno, tolueno, etilbenzeno e xilenos (BTEX) em reator anaeróbio horizontal de leito fixo (RAHLF) / Benzene, toluene, ethylbenzene and xylenes (BTEX) degradation in horizontal-flow anaerobic immobilized biomass (HAIB) reactor

Ivana Ribeiro De Nardi 05 April 2002 (has links)
A atividade industrial diversificada tem sido responsável pelo lançamento, no ambiente, de resíduos que contém materiais tóxicos e/ou de difícil degradação. Benzeno, tolueno, etilbenzeno e xilenos (BTEX) são compostos importantes, por estarem presentes em águas superficiais e subterrâneas, geralmente a partir de contaminações por derivadas de petróleo. Enquanto a degradação aeróbia de BTEX já está amplamente entendida e descrita, a aplicação de processos anaeróbios de tratamento, indicados na década de 80 ainda requer mais estudos. Reatores anaeróbios horizontais de leito fixo de bancada preenchidos com cubos de espuma de poliuretano, contendo lodo anaeróbio proveniente de diversas fontes trataram a água residuária sintética a base de proteínas, carboidratos, lipídios, contendo solução etanólica de BTEX e solução de BTEX em detergente comercial; e solução etanólica de BTEX como únicas fontes de carbono. A influência da adição de nitrato e sulfato como aceptores de elétrons na degradação anaeróbia também é discutida. Os reatores foram capazes de remover BTEX nas concentrações testadas de até 15,0 mg/L de cada composto, com tempos de detenção hidráulica de 11,4 horas e 13,5 horas. Os reatores forneceram condições excelentes para o desenvolvimento de biofilme complexo capaz de degradar BTEX, contendo organismos degradadores de BTEX, acetogênicos, acetoclásticos e hidrogenotróficos. Arqueas metanogênicas representaram menos de 0,5% do total de organismos anaeróbios na biomassa dos reatores. O modelo cinético de primeira ordem com residual foi o que melhor representou os dados experimentais e as velocidades de degradações de BTEX, estimadas neste trabalho, foram cerca de 10 a 94 vezes maiores que as encontradas na literatura, em ensaios realizados em microcosmos. / The diversified industrial activity has been responsible for discharge in the environment of toxic and/or difficult degradation compounds. Benzene, toluene, ethylbenzene and xylenes (BTEX) are important compounds present in surface and ground waters, usually from petroleum products contamination. While BTEX aerobic degradation is extensively understood and described, anaerobic treatment application, started in the eighties, associated to fundamental studies need to be improved. Bench-scale horizontal-flow anaerobic immobilized biomass reactors filled with polyurethane foam matrices, containing immobilized anaerobic biomass from various sources, treated synthetic substrate containing protein, carbohydrates, lipids, BTEX solution in ethanol and BTEX solution in commercial detergent, as well as BTEX solution in ethanol as the sole carbon source. The influence of the addition of nitrate and sulfate as electron acceptors on anaerobic degradation is also discussed. The reactors were able to remove up to 15.0 mg/L of each BTEX compound, with hydraulic detention time of 11.4 hours and 13.5 hours. The reactors provided excellent conditions for developing a complex biofilm with BTEX-degraders, acetogenic, acetoclastic and hydrogenotrophic microorganisms. Methanogenic archaea were found to represent less than 0.5% of the total anaerobic organisms in the biomass inside the reactors. Residual first order kinetic model fitted well the experimental data and the BTEX degradation rates, estimated in this work, were about 10- to 94-fold higher than those found in the literature, in microcosms studies.
33

Tratamento de água residuária parcialmente solúvel em reator anaeróbio em batelada seqüencial contendo biomassa imobilizada e agitação mecânica: análise da influência da intensidade de agitação e do tamanho de biopartícula / Treatment of partially soluble wastewater in an anaerobic sequencing batch reactor with immobilized biomass and mechanical stirring: analysis of the influence of agitation rate and bioparticle size

Pinho, Samantha Cristina de 09 June 2004 (has links)
Neste trabalho de doutorado utilizou-se um reator anaeróbio em batelada seqüencial contendo biomassa imobilizada em matrizes cúbicas de espuma de poliuretano e agitação mecânica, com volume total de 5.5 L e volume útil de 4.5 L. A agitação do meio líquido foi realizada com quatro tipos de impelidores (turbina tipo hélice, lâminas planas, lâminas planas inclinadas e lâminas curvas, testados individualmente, sempre em número de 3), com 6 cm de diâmetro. A pesquisa foi realizada em quatro etapas experimentais. A etapa 1 objetivou determinar o tempo de mistura no reator para cada tipo de impelidor, ou seja, o tempo necessário para que o meio líquido ficasse totalmente homogêneo. A etapa 2 objetivou selecionar o tipo de impelidor e a respectiva intensidade de agitação que garantisse a minimização da resistência à transferência de massa externa no sistema. As intensidades de agitação testadas variaram de 200 a 1100 rpm, dependendo do tipo de impelidor. A etapa 3 foi realizada com tipo de impelidor e intensidade de agitação definidos na etapa 2, mas variando-se o tamanho da biopartícula (0,5, 1,0, 2,0 e 3,0 cm de aresta). O objetivo desta etapa foi selecionar o tamanho de biopartícula que minimizasse a resistência à transferência de massa interna. De posse das condições operacionais otimizadas (tipo de impelidor, intensidade de agitação e tamanho de partícula de suporte), a etapa 4 constituiu na aplicação das mesmas para o tratamento de um resíduo real, sendo escolhida água residuária de suinocultura. Na etapa 1, os resultados mostraram que os tempos de mistura para todos os tipos de impelidores foram desprezíveis em relação ao tempo total de ciclo. A etapa 2 revelou tempos de partida muito curtos (cerca de 20 dias), em todas as condições testadas, sendo atingidas remoções de DQO próximas de 70%. Além disso, o tipo de impelidor exerceu grande influência na qualidade final do efluente, fato este claramente constatado quando as frações de DQO foram consideradas separadamente (filtrada e suspensa). De acordo com os resultados obtidos na etapa 3, o tamanho da biopartícula teve influência decisiva no desempenho do sistema, nas condições testadas. As velocidades de dissolução foram aparentemente influenciadas pelo empacotamento do leito de espuma, enquanto que o consumo da fração de DQO correspondente às amostras filtradas foi provavelmente influenciado por fatores mais complexos. Finalmente, o teste realizado com resíduo diluído de suinocultura demonstrou que a operação do reator em estudo para o tratamento deste tipo de água residuária é possível. Os dados operacionais mostraram que o reator permaneceu estável durante o período testado. A agitação mecânica provou ser eficiente para melhorar a degradação da DQO suspensa, um dos maiores problemas no tratamento deste tipo de água residuária. Sendo assim, de acordo com os dados experimentais obtidos ao longo do trabalho, pode-se afirmar que a agitação em reatores em batelada mostrou-se importante não somente para proporcionar boas condições de mistura ou melhorar a transferência de massa na fase líquida, mas também para melhorar a solubilização da matéria orgânica particulada, melhorando as velocidades de consumo de matéria orgânica. / The bench-scale anaerobic sequencing batch reactor containing immobilized biomass and provided with mechanical stirring employed in this work had total and useful volumes of 5.5 and 4.5 L, respectively. The biomass was immobilized on cubic polyurethane foam matrices, and the agitation of the liquid medium was provided by four types of impellers (propeller, flat-blade, pitched-blade and curved-blade turbines, individually tested, always in a set of three), with 6 cm of diameter. The research was divided into 4 experimental steps. The first one aimed at determining the mixing time in the reactor for each sort of impeller, i.e., the time necessary for the system to be completely homogeneized. As for the second step, its objective was to choose the sort of impeller and the agitation rate suitable for minimizing the external mass-transfer resistance. The agitation rates tests ranged from 200 to 1100 rpm, depending on the impeller type. The step 3 was carried out utilizing the chosen impeller and agitation rate, but varying the bioparticle size (0.5, 1.0, 2.0 and 3.0 cm of side). The aim of these experiments was to determine the bioparticle size that minimized the solid-phase mass transfer. Using these optimized operational conditions (type of impeller and bioparticle size), the step 4 consisted of the utilization of them in the treatment of a real wastewater (diluted swine manure). As for the results, step 1 showed the mixing times were very low compared to the total cycle times employed in the experiments (8 and 24 h). Very short start-up periods were revealed by the second experimental part (about 20 days in average) for all conditions tested, and the removal efficiencies reached approximately 70%. Besides that, the impeller type exerted great influence on the final quality of the effluent, fact clearly observed when the COD fractions were analyzed separately (filtered and suspended). According to the data obtained in the step 3, the bioparticle size influenced decisively on the performance of the system, in the conditions tested. The bed packing apparently influenced the dissolution rates, whereas the consumption of the COD correspondent to the filtered samples was defined by more complex factors. Finally, the test with the diluted swine manure demonstrated that the operation of this reactor with this type of wastewater is feasible, as the operational data showed the reactor remained stable during all the period tested. The mechanical stirring proved to be efficient to improve the degradation of the suspended COD, one of the major problems in the treatment of this type of wastewater. In this sense, according to the experimental data obtained in this work, it can be affirmed the mechanical stirring in anaerobic sequencing batch reactors showed to be not only important to provide good mixing conditions and improve the liquid phase mass transfer, but also to improve the solubilization of the particulate organic matter and increase the overall organic matter consumption rates.
34

Geração de metano em reator UASB: avaliação de parâmetros de monitoramento para controle do processo de tratamento anaeróbio de vinhaça / Methane generation in a UASB reactor: evaluation of monitoring parameters for control of anaerobic treatment process of vinasse

Longo, Rodrigo Rodrigues 29 May 2015 (has links)
Com o propósito de explorar o potencial de geração de metano a partir de vinhaça de cana-de-açúcar e propor procedimentos de controle do processo anaeróbio, foi utilizado um reator UASB (Upflow Anaerobic Sludge Blanket) em escala piloto, equipado de separador gás-sólido-líquido modificado e sem recirculação de efluente. A unidade foi inoculada com lodo granular e utilizou-se substrato concentrado (DQO de 20 g.L-1) para sua alimentação. O reator foi submetido a cargas orgânicas volumétricas (COV) de 0,7 a 7 KgDQO.m-3.d-1, durante 300 dias de operação. O procedimento operacional baseou-se no aumento de carga por escalonamento da vazão de alimentação em função da manutenção de variação inferior a 10% para a eficiência do sistema. Para o tamponamento da vinhaça de alimentação, no início da operação utilizou-se 1g NaHCO3.g-1DQOafluente, com redução gradativa até 0,125g NaHCO3.g-1DQOafluente. O monitoramento do desempenho do processo anaeróbio se deu pela avaliação dos parâmetros: eficiência de remoção de DQO, pH, alcalinidade, ácidos voláteis, razão alcalinidade intermediária/alcalinidade parcial, razão Prop:Ac, vazão de metano e porcentagem de metano no biogás. O reator UASB apresentou valor médio de eficiência de remoção de DQO de 92±4,4%, para cargas aplicadas entre 0,7 e 4,8 KgDQO.m-3.d-1. A maior produção média de metano observada durante o período operacional foi 5 m3CH4.m-3 de vinhaça aplicada para cargas orgânicas entre 4,1 e 5,6 KgDQO.m-3.d-1. A produção de biogás apresentou valor médio de metano de 70±7% para 1 a 5,6 Kg DQO.m-3.d-1. A operação do reator com cargas aplicadas acima de 5,6 KgDQO.m-3.d-1 gerou menor produção de biogás, redução na porcentagem de metano e aumento da carga de ácidos voláteis efluente, assim como queda na eficiência de remoção de DQO. Devido ao acréscimo de carga (0-2 para 4-6 KgDQO.m-3.d-1), a variação da concentração para cada tipo de ácido foi: acético (56±70 para 216±121 mg.L-1), propiônico (26±28 para 165±150 mg.L-1) e butírico (4±7 para 60±18 mg.L-1). Notou-se que a relação entre as concentrações de ácido propiônico e ácido acético (razão Prop:Ac) pode ser utilizada como parâmetro de monitoramento da estabilidade do reator. A elevação de COV de 3,9 a 6,4 KgDQO.m-3.d-1acarretou alteração na razão Prop:Ac de 0,8 a 1,75, corroborando descontroles do processo anaeróbio associado à queda de eficiência na geração de metano. / In order to explore the potential of methane generation from sugarcane vinasse and propose procedures for the anaerobic process control, was utilized a pilot scale UASB reactor (Upflow Anaerobic Sludge Blanket), equipped with modified gas-solid-liquid separator and without recirculation of effluent. The unit was inoculated with granular sludge and concentrated substrate was used (COD 20 g.L-1) for feeding. The reactor was submitted to volumetric organic load (VOL) from 0.7 to 7 KgCOD.m-3.d-1, during 300 days of operation. The reactor operation was based on the increase of load by staggering the feed flow in function of the maintenance of variation lower than 10% for the system efficiency. For buffering the feedings vinasse was used 1g NaHCO3.g-1CODinfluent at the beginning of the operation, with gradual reduction to the value of 0.125 g NaHCO3.g-1CODinfluent. The monitoring of the anaerobic process performance was due to the evaluation of the following parameters: efficiency of COD removal pH, alkalinity, intermediate alkalinity/partial alkalinity ratio; Prop:Ac ratio, methane flow and percentage of methane in the biogas. The UASB reactor demonstrated a COD average removal efficiency of 92±4.4%, to applied loads between 0.7 and 4.8 KgCOD.m-3.d-1. The highest average methane production observed during the operational period was 5 m3CH4.m-3 of vinasse applied for organic loads between 4.1 and 5.6 KgCOD.m-3.d-1. The biogás production demonstrated a methane average of 70±7% for 1 to 5.6 KgCOD.m-3.d-1. The reactor operation with loads up to 5.6 KgCOD.m-3.d-1 caused lower production of biogas, reduction in the percentage of methane and increase for effluent volatile acids load, as well as decrease of COD removal efficiency. Due to the additional load (0-2 to 4-6 KgCOD.m-3.d-1), the change in concentration for each type of acid was: acetic acid (56±70 to 216±121 mg.L-1), propionic acid (26±28 to 165±150 mg.L-1) and butyric acid (4±7 to 60 ± 18 mg.L-1). It was noted that the relationship between the concentrations of propionic acid and acetic acid (ratio Prop:Ac) may be used as a monitoring parameter of the reactor stability. The increase in VOL of 3.9 to 6.4 KgCOD.m-3.d-1 caused change in the Prop:Ac ratio of 0.8 to 1.75, confirming the upsets on the anaerobic process associated with efficiency drop in methane generation.
35

IWESS, an integrated water, energy and sanitation solution : A holistic approach to reach sustainability trough organic waste management for the Lake Victoria Basin, Kenya

Martinsson, Erik, Martinsson, Emil, Säf, Sören January 2008 (has links)
The process of allocating necessary resources like clean water, fuel/energy and food have resulted in an unsustainable use of natural resources causing problems with Soil erosion, soil fertility, desertification, deforestation, eutrophication and global warming. The purpose of this study was to gain information on the functional design of a waste management system enabling the organic components of domestic waste to be processed as useful resources while at the same time allow them to be re-circulated. The main part of this study was carried out at the Kendu SDA Hospital in the Rachyonyo district in western Kenya. For the case of this study two main objectives where chosen. The first was to develop a principal technological solution using three classed “appropriate technologies” found suitable for the purpose namely biogas, ecological water treatment systems and slow sand filtration. The second was to further analyse each included technology to further develop their potential to fit the concept. Results from the pilot facilities where then to be retrieved from the actual component selection and construction process itself, with performance analysis left for future studies. The main purpose of the biogas system study has been to evaluate the original ideas of overall concept, details, materials and construction methods. The 1 m3 biogas system has improved significantly during the development process and is today not far from an implementation, i.e. construction on a slightly larger scale. The biogas system developed during the project has proven to have potential for digestion of both latrine and kitchen waste. Using the two as fuel for the process does not only remove a problem – it grants several benefits. The ecological waste water treatment system main objective was to design and construct a pilot SSF-wetland. Results show that the construction process for smaller scaled SSF systems is simple and does not require trained personnel or specialized equipment and that significant cost reduction can be made by using locally available materials. The slow sand filtration sub system concept is called PT SCX and though still in the stage of development proved to have great potential concerning both efficiency and sustainability. The PT SCX comprises the advantages of slow sand filtration with further development of individual system solutions. It was adapted to enable both integration to the IWESS solution and stand alone installations purifying even highly turbid surface water sources to drinking water quality. The result from the study confirms the suitability of the three included technologies, ecological waste water treatment, biogas and slow sand filtration to work in an integrated system called IWESS- Integrated Water Energy and Sanitation Solution. The combined subsystems can together with source separated sewage offer full resource recovery enabling recirculation of both nutrients and water. In addition the system can be designed as a net producer of renewable and emission free energy.
36

IWESS, an integrated water, energy and sanitation solution : A holistic approach to reach sustainability trough organic waste management for the Lake Victoria Basin, Kenya

Martinsson, Erik, Martinsson, Emil, Säf, Sören January 2008 (has links)
<p>The process of allocating necessary resources like clean water, fuel/energy and food have resulted in an unsustainable use of natural resources causing problems with Soil erosion, soil fertility, desertification, deforestation, eutrophication and global warming. The purpose of this study was to gain information on the functional design of a waste management system enabling the organic components of domestic waste to be processed as useful resources while at the same time allow them to be re-circulated. The main part of this study was carried out at the Kendu SDA Hospital in the Rachyonyo district in western Kenya. For the case of this study two main objectives where chosen. The first was to develop a principal technological solution using three classed “appropriate technologies” found suitable for the purpose namely biogas, ecological water treatment systems and slow sand filtration. The second was to further analyse each included technology to further develop their potential to fit the concept. Results from the pilot facilities where then to be retrieved from the actual component selection and construction process itself, with performance analysis left for future studies.</p><p>The main purpose of the biogas system study has been to evaluate the original ideas of overall concept, details, materials and construction methods. The 1 m3 biogas system has improved significantly during the development process and is today not far from an implementation, i.e. construction on a slightly larger scale. The biogas system developed during the project has proven to have potential for digestion of both latrine and kitchen waste. Using the two as fuel for the process does not only remove a problem – it grants several benefits.</p><p>The ecological waste water treatment system main objective was to design and construct a pilot SSF-wetland. Results show that the construction process for smaller scaled SSF systems is simple and does not require trained personnel or specialized equipment and that significant cost reduction can be made by using locally available materials.</p><p>The slow sand filtration sub system concept is called PT SCX and though still in the stage of development proved to have great potential concerning both efficiency and sustainability. The PT SCX comprises the advantages of slow sand filtration with further development of individual system solutions. It was adapted to enable both integration to the IWESS solution and stand alone installations purifying even highly turbid surface water sources to drinking water quality.</p><p>The result from the study confirms the suitability of the three included technologies, ecological waste water treatment, biogas and slow sand filtration to work in an integrated system called IWESS- Integrated Water Energy and Sanitation Solution. The combined subsystems can together with source separated sewage offer full resource recovery enabling recirculation of both nutrients and water. In addition the system can be designed as a net producer of renewable and emission free energy.</p>
37

Tratamento de água residuária parcialmente solúvel em reator anaeróbio em batelada seqüencial contendo biomassa imobilizada e agitação mecânica: análise da influência da intensidade de agitação e do tamanho de biopartícula / Treatment of partially soluble wastewater in an anaerobic sequencing batch reactor with immobilized biomass and mechanical stirring: analysis of the influence of agitation rate and bioparticle size

Samantha Cristina de Pinho 09 June 2004 (has links)
Neste trabalho de doutorado utilizou-se um reator anaeróbio em batelada seqüencial contendo biomassa imobilizada em matrizes cúbicas de espuma de poliuretano e agitação mecânica, com volume total de 5.5 L e volume útil de 4.5 L. A agitação do meio líquido foi realizada com quatro tipos de impelidores (turbina tipo hélice, lâminas planas, lâminas planas inclinadas e lâminas curvas, testados individualmente, sempre em número de 3), com 6 cm de diâmetro. A pesquisa foi realizada em quatro etapas experimentais. A etapa 1 objetivou determinar o tempo de mistura no reator para cada tipo de impelidor, ou seja, o tempo necessário para que o meio líquido ficasse totalmente homogêneo. A etapa 2 objetivou selecionar o tipo de impelidor e a respectiva intensidade de agitação que garantisse a minimização da resistência à transferência de massa externa no sistema. As intensidades de agitação testadas variaram de 200 a 1100 rpm, dependendo do tipo de impelidor. A etapa 3 foi realizada com tipo de impelidor e intensidade de agitação definidos na etapa 2, mas variando-se o tamanho da biopartícula (0,5, 1,0, 2,0 e 3,0 cm de aresta). O objetivo desta etapa foi selecionar o tamanho de biopartícula que minimizasse a resistência à transferência de massa interna. De posse das condições operacionais otimizadas (tipo de impelidor, intensidade de agitação e tamanho de partícula de suporte), a etapa 4 constituiu na aplicação das mesmas para o tratamento de um resíduo real, sendo escolhida água residuária de suinocultura. Na etapa 1, os resultados mostraram que os tempos de mistura para todos os tipos de impelidores foram desprezíveis em relação ao tempo total de ciclo. A etapa 2 revelou tempos de partida muito curtos (cerca de 20 dias), em todas as condições testadas, sendo atingidas remoções de DQO próximas de 70%. Além disso, o tipo de impelidor exerceu grande influência na qualidade final do efluente, fato este claramente constatado quando as frações de DQO foram consideradas separadamente (filtrada e suspensa). De acordo com os resultados obtidos na etapa 3, o tamanho da biopartícula teve influência decisiva no desempenho do sistema, nas condições testadas. As velocidades de dissolução foram aparentemente influenciadas pelo empacotamento do leito de espuma, enquanto que o consumo da fração de DQO correspondente às amostras filtradas foi provavelmente influenciado por fatores mais complexos. Finalmente, o teste realizado com resíduo diluído de suinocultura demonstrou que a operação do reator em estudo para o tratamento deste tipo de água residuária é possível. Os dados operacionais mostraram que o reator permaneceu estável durante o período testado. A agitação mecânica provou ser eficiente para melhorar a degradação da DQO suspensa, um dos maiores problemas no tratamento deste tipo de água residuária. Sendo assim, de acordo com os dados experimentais obtidos ao longo do trabalho, pode-se afirmar que a agitação em reatores em batelada mostrou-se importante não somente para proporcionar boas condições de mistura ou melhorar a transferência de massa na fase líquida, mas também para melhorar a solubilização da matéria orgânica particulada, melhorando as velocidades de consumo de matéria orgânica. / The bench-scale anaerobic sequencing batch reactor containing immobilized biomass and provided with mechanical stirring employed in this work had total and useful volumes of 5.5 and 4.5 L, respectively. The biomass was immobilized on cubic polyurethane foam matrices, and the agitation of the liquid medium was provided by four types of impellers (propeller, flat-blade, pitched-blade and curved-blade turbines, individually tested, always in a set of three), with 6 cm of diameter. The research was divided into 4 experimental steps. The first one aimed at determining the mixing time in the reactor for each sort of impeller, i.e., the time necessary for the system to be completely homogeneized. As for the second step, its objective was to choose the sort of impeller and the agitation rate suitable for minimizing the external mass-transfer resistance. The agitation rates tests ranged from 200 to 1100 rpm, depending on the impeller type. The step 3 was carried out utilizing the chosen impeller and agitation rate, but varying the bioparticle size (0.5, 1.0, 2.0 and 3.0 cm of side). The aim of these experiments was to determine the bioparticle size that minimized the solid-phase mass transfer. Using these optimized operational conditions (type of impeller and bioparticle size), the step 4 consisted of the utilization of them in the treatment of a real wastewater (diluted swine manure). As for the results, step 1 showed the mixing times were very low compared to the total cycle times employed in the experiments (8 and 24 h). Very short start-up periods were revealed by the second experimental part (about 20 days in average) for all conditions tested, and the removal efficiencies reached approximately 70%. Besides that, the impeller type exerted great influence on the final quality of the effluent, fact clearly observed when the COD fractions were analyzed separately (filtered and suspended). According to the data obtained in the step 3, the bioparticle size influenced decisively on the performance of the system, in the conditions tested. The bed packing apparently influenced the dissolution rates, whereas the consumption of the COD correspondent to the filtered samples was defined by more complex factors. Finally, the test with the diluted swine manure demonstrated that the operation of this reactor with this type of wastewater is feasible, as the operational data showed the reactor remained stable during all the period tested. The mechanical stirring proved to be efficient to improve the degradation of the suspended COD, one of the major problems in the treatment of this type of wastewater. In this sense, according to the experimental data obtained in this work, it can be affirmed the mechanical stirring in anaerobic sequencing batch reactors showed to be not only important to provide good mixing conditions and improve the liquid phase mass transfer, but also to improve the solubilization of the particulate organic matter and increase the overall organic matter consumption rates.
38

Geração de metano em reator UASB: avaliação de parâmetros de monitoramento para controle do processo de tratamento anaeróbio de vinhaça / Methane generation in a UASB reactor: evaluation of monitoring parameters for control of anaerobic treatment process of vinasse

Rodrigo Rodrigues Longo 29 May 2015 (has links)
Com o propósito de explorar o potencial de geração de metano a partir de vinhaça de cana-de-açúcar e propor procedimentos de controle do processo anaeróbio, foi utilizado um reator UASB (Upflow Anaerobic Sludge Blanket) em escala piloto, equipado de separador gás-sólido-líquido modificado e sem recirculação de efluente. A unidade foi inoculada com lodo granular e utilizou-se substrato concentrado (DQO de 20 g.L-1) para sua alimentação. O reator foi submetido a cargas orgânicas volumétricas (COV) de 0,7 a 7 KgDQO.m-3.d-1, durante 300 dias de operação. O procedimento operacional baseou-se no aumento de carga por escalonamento da vazão de alimentação em função da manutenção de variação inferior a 10% para a eficiência do sistema. Para o tamponamento da vinhaça de alimentação, no início da operação utilizou-se 1g NaHCO3.g-1DQOafluente, com redução gradativa até 0,125g NaHCO3.g-1DQOafluente. O monitoramento do desempenho do processo anaeróbio se deu pela avaliação dos parâmetros: eficiência de remoção de DQO, pH, alcalinidade, ácidos voláteis, razão alcalinidade intermediária/alcalinidade parcial, razão Prop:Ac, vazão de metano e porcentagem de metano no biogás. O reator UASB apresentou valor médio de eficiência de remoção de DQO de 92±4,4%, para cargas aplicadas entre 0,7 e 4,8 KgDQO.m-3.d-1. A maior produção média de metano observada durante o período operacional foi 5 m3CH4.m-3 de vinhaça aplicada para cargas orgânicas entre 4,1 e 5,6 KgDQO.m-3.d-1. A produção de biogás apresentou valor médio de metano de 70±7% para 1 a 5,6 Kg DQO.m-3.d-1. A operação do reator com cargas aplicadas acima de 5,6 KgDQO.m-3.d-1 gerou menor produção de biogás, redução na porcentagem de metano e aumento da carga de ácidos voláteis efluente, assim como queda na eficiência de remoção de DQO. Devido ao acréscimo de carga (0-2 para 4-6 KgDQO.m-3.d-1), a variação da concentração para cada tipo de ácido foi: acético (56±70 para 216±121 mg.L-1), propiônico (26±28 para 165±150 mg.L-1) e butírico (4±7 para 60±18 mg.L-1). Notou-se que a relação entre as concentrações de ácido propiônico e ácido acético (razão Prop:Ac) pode ser utilizada como parâmetro de monitoramento da estabilidade do reator. A elevação de COV de 3,9 a 6,4 KgDQO.m-3.d-1acarretou alteração na razão Prop:Ac de 0,8 a 1,75, corroborando descontroles do processo anaeróbio associado à queda de eficiência na geração de metano. / In order to explore the potential of methane generation from sugarcane vinasse and propose procedures for the anaerobic process control, was utilized a pilot scale UASB reactor (Upflow Anaerobic Sludge Blanket), equipped with modified gas-solid-liquid separator and without recirculation of effluent. The unit was inoculated with granular sludge and concentrated substrate was used (COD 20 g.L-1) for feeding. The reactor was submitted to volumetric organic load (VOL) from 0.7 to 7 KgCOD.m-3.d-1, during 300 days of operation. The reactor operation was based on the increase of load by staggering the feed flow in function of the maintenance of variation lower than 10% for the system efficiency. For buffering the feedings vinasse was used 1g NaHCO3.g-1CODinfluent at the beginning of the operation, with gradual reduction to the value of 0.125 g NaHCO3.g-1CODinfluent. The monitoring of the anaerobic process performance was due to the evaluation of the following parameters: efficiency of COD removal pH, alkalinity, intermediate alkalinity/partial alkalinity ratio; Prop:Ac ratio, methane flow and percentage of methane in the biogas. The UASB reactor demonstrated a COD average removal efficiency of 92±4.4%, to applied loads between 0.7 and 4.8 KgCOD.m-3.d-1. The highest average methane production observed during the operational period was 5 m3CH4.m-3 of vinasse applied for organic loads between 4.1 and 5.6 KgCOD.m-3.d-1. The biogás production demonstrated a methane average of 70±7% for 1 to 5.6 KgCOD.m-3.d-1. The reactor operation with loads up to 5.6 KgCOD.m-3.d-1 caused lower production of biogas, reduction in the percentage of methane and increase for effluent volatile acids load, as well as decrease of COD removal efficiency. Due to the additional load (0-2 to 4-6 KgCOD.m-3.d-1), the change in concentration for each type of acid was: acetic acid (56±70 to 216±121 mg.L-1), propionic acid (26±28 to 165±150 mg.L-1) and butyric acid (4±7 to 60 ± 18 mg.L-1). It was noted that the relationship between the concentrations of propionic acid and acetic acid (ratio Prop:Ac) may be used as a monitoring parameter of the reactor stability. The increase in VOL of 3.9 to 6.4 KgCOD.m-3.d-1 caused change in the Prop:Ac ratio of 0.8 to 1.75, confirming the upsets on the anaerobic process associated with efficiency drop in methane generation.

Page generated in 0.0742 seconds