Spelling suggestions: "subject:"anemometer"" "subject:"anemometry""
1 |
Avaliacao da fluxometria laser doppler como teste de vitalidade pulparEDUARDO, FLAVIA T. de O. de PAULA 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:49:27Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:02:28Z (GMT). No. of bitstreams: 1
10284.pdf: 2486069 bytes, checksum: 20878b727a99c4512cfcae6179c9ff90 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
2 |
Avaliacao da fluxometria laser doppler como teste de vitalidade pulparEDUARDO, FLAVIA T. de O. de PAULA 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:49:27Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:02:28Z (GMT). No. of bitstreams: 1
10284.pdf: 2486069 bytes, checksum: 20878b727a99c4512cfcae6179c9ff90 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
3 |
Estudo das origens e funções do fluxo sanguíneo medido em dentes humanos usando a fluxometria laser DopplerCORREA, MELISSA S.F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:54:56Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:59Z (GMT). No. of bitstreams: 1
12801.pdf: 2431192 bytes, checksum: b7e93ba00685003bca6016af5031d88f (MD5) / Dissertação (Mestrado Profissionalizante em Lasers em Odontologia) / IPEN/D-MPLO / Instituto de Pesquisas Energéticas e Nucleares - IPEN/CNEN-SP; Faculdade de Odontologia, Universidade de São Paulo, São Paulo
|
4 |
Fluxometria laser doppler da polpa dental apos o clareamento com laser de diodoMORAES, MARIANA P. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:52:44Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:06Z (GMT). No. of bitstreams: 1
13713.pdf: 2929463 bytes, checksum: 0637522e7b2fbcf6cf36b794dceb09a6 (MD5) / Dissertacao (Mestrado Profissionalizante em Lasers em Odontologia) / IPEN/D-MPLO / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
5 |
Caracterização das flutuações do sinal doppler do fluxo microvascular / Characterization of laser doppler signal fluctuations in microvascular flowFOLGOSI CORREA, MELISSA S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:00Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:05Z (GMT). No. of bitstreams: 0 / O sinal de fluxo cutâneo obtido via fluxometria Laser Doppler (SFLD) tem flutuações de baixas frequências que estão relacionadas a mecanismos de controle do fluxo microvascular. Análises espectrais, via transformada de Fourier e transformada de wavelet, têm sido usadas para correlacionar as flutuações de SFLD com os seguintes mecanismos de controle de fluxo: metabólico, metabólico NO-dependente, neurogênico e miogênico, nos respectivos intervalos de frequência 0,005-0,0095 Hz, 0,0095-0,02 Hz, 0,02-0,05 Hz e 0,05-0,15 Hz. A potência do sinal, em cada intervalo de frequência, geralmente é usada como uma medida da atividade do mecanismo de controle microvascular relacionado. Uma vez que os métodos usados de análise são espectrais, as características das flutuações do SFLD, em cada intervalo de frequência, no domínio do tempo são desconhecidas. Como consequência, há ausência de critérios objetivos para medir adequadamente, em cada intervalo de frequência, os parâmetros hemodinâmicos relacionados. O objetivo deste trabalho foi caracterizar e quantificar flutuações temporais, espaciais e espaço-temporais do SFLD em cada faixa de frequência, usando um método no domínio do tempo. Os fluxos basais (320C) e termicamente estimulados à (420C) das regiões volares de antebraços de 20 voluntários saudáveis foram coletados em duas regiões próximas e analisados. As análises dos dados obtidos indicam que janelas temporais pequenas (1 minuto) são aceitáveis para a quantificação do fluxo médio, e que janelas temporais maiores são necessários para quantificar as flutuações de fluxo. A análise espaço-temporal revelou uma forte correlação entre sinais (em todas as bandas, exceto na banda B5) das duas regiões investigadas, durante longos intervalos de tempo, quando as duas regiões estudadas foram termicamente estimuladas, e menor variabilidade intragrupo quando comparada à obtida para os valores médios das flutuações, sugerindo que o intervalo de tempo de correlação é um parâmetro promissor para estudar mecanismos de controle do fluxo microvascular. / Tese (Doutoramento) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
|
6 |
Fluxometria laser doppler da polpa dental apos o clareamento com laser de diodoMORAES, MARIANA P. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:52:44Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:06Z (GMT). No. of bitstreams: 1
13713.pdf: 2929463 bytes, checksum: 0637522e7b2fbcf6cf36b794dceb09a6 (MD5) / Dissertacao (Mestrado Profissionalizante em Lasers em Odontologia) / IPEN/D-MPLO / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
7 |
Análise de Sensibilidade de Anemômetros a Temperatura Constante Baseados em Sensor Termo-resistivo / Analysis of Sensitivity of Based Anemometers the Constant Temperature in Term SensorGabriel, Michel Valença 30 January 2004 (has links)
Made available in DSpace on 2016-08-17T14:52:51Z (GMT). No. of bitstreams: 1
Michel Valenca Gabriel.pdf: 465513 bytes, checksum: 942d92f812d9d94a2f9910b710ac55f2 (MD5)
Previous issue date: 2004-01-30 / In this work we present a study on the sensitivity of anemometers based on
thermoresistive sensors heated to a constant temperature. The configurations that makes the
thermoresistive sensor heated to a constant temperature are composed of a Wheatstone bridge
using a feedback operational amplifier. The substitution measurement method is used, where an
electrical quantity, the operational amplifier output voltage, varies in accordance to the variation
of the quantity of interest, in such a way that the electrical quantity compensates the effect of the
former in the sensor. In our case, the quantity to be measured is the speed of the wind and the
quantity of substitution is operational amplifier output voltage. Studies were carried out
considering two types of sensors, the metallic PTC and the thermistor NTC.
An analysis of the measurement circuits was carried out for each sensor type, taking into
account the constants and variables that influence the measurement process. For these circuits,
simulation results are presented which make possible to evaluate the measurement system
behavior. An analysis of the sensitivity of the measurement circuits output voltage with respect
to the wind speed is also carried out. This analysis made possible the development of a
procedure for determining the operation point for the NTC-based circuit that yields the
maximum sensitivity.
From the analysis of the measurement configurations sensitivity, it was observed that the
NTC-based configuration presents higher sensitivity compared to the PTC-based configuration,
for relatively low operating temperatures, above the ambient temperature. The equivalent
sensitivity for the PTC-based configuration occurs only for temperatures much higher than that
for achieving the maximum sensitivity for the NTC. This characteristic can be used for
implementing anemometers that operates at a temperature much closer to the ambient temperature. / Neste trabalho apresentamos um estudo sobre a sensibilidade de anemômetros baseados
em sensores termo-resistivos aquecidos a temperatura constante. A configuração que faz com
que o sensor termo-resistivo seja aquecido a uma temperatura constante é composta de uma
ponte de Wheatstone realimentada usando um amplificador operacional [1]. O método de
medição utilizado é o de substituição, em que uma grandeza elétrica, a tensão de saída do
amplificador operacional, varia de acordo com a variação da grandeza de interesse, de forma a
compensar seu efeito no sensor. Neste caso, a grandeza a ser medida é a velocidade do vento e a
grandeza de substituição é a tensão de saída do amplificador operacional. Foram feitos estudos
considerandos dois tipos de sensores, o PTC metálico e o termistor NTC.
Faz-se uma análise dos circuitos de medição para cada tipo de sensor, levando em conta
as constantes e as variáveis que interferem no processo de medição. Para tais circuitos são
apresentados resultados de simulações em computador que nos possibilitaram avaliar o
comportamento do sistema de medição. Para os circuitos de medição, faz-se uma análise da
sensibilidade da tensão de saída do amplificador operacional com relação à velocidade do vento.
Essa análise possibilitou desenvolvimento de um método para cálculo do ponto de maior
sensibilidade e ponto de operação do circuito baseado no NTC.
Observou-se que a configuração com NTC apresenta uma maior sensibilidade do que a
configuração com PTC para temperaturas de operação do sensor relativamente baixas, mas
acima da temperatura ambiente. A sensibilidade equivalente da configuração com o PTC ocorre
para temperaturas bem acima do ponto de máxima sensibilidade do NTC. Essa característica
pode ser aproveitada para implementações de anemômetros aquecidos que operam com
temperaturas mais próximas da temperatura ambiente.
|
8 |
Echo-planar anemometry using conventional magnetic resonance imaging hardwareDerbyshire, John Andrew January 1995 (has links)
No description available.
|
9 |
Avaliação de dois métodos de análise da microcirculação gengival via fluxometria Laser DopplerLEITE, PAULA S.A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:54:09Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:14Z (GMT). No. of bitstreams: 1
12700.pdf: 3254214 bytes, checksum: 3ca272c1fec4a2ef9d9cc0005e976dc4 (MD5) / Dissertacao (Mestrado Profissionalizante em Lasers em Odontologia) / IPEN/D-MPLO / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP; Faculdade de Odontologia, Universidade de Sao Paulo , Sao Paulo
|
10 |
Avaliação de dois métodos de análise da microcirculação gengival via fluxometria Laser DopplerLEITE, PAULA S.A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:54:09Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:14Z (GMT). No. of bitstreams: 1
12700.pdf: 3254214 bytes, checksum: 3ca272c1fec4a2ef9d9cc0005e976dc4 (MD5) / Dissertacao (Mestrado Profissionalizante em Lasers em Odontologia) / IPEN/D-MPLO / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP; Faculdade de Odontologia, Universidade de Sao Paulo , Sao Paulo
|
Page generated in 0.4654 seconds