Estudo comparativo entre métodos de calibração de aplicadores clínicos de radiação beta / COMPARATIVE STUDY AMONG CALIBRATION METHODS OF CLINICAL APPLICATORS OF BETA RADIATION

Antonio, Patrícia de Lara 03 September 2009 (has links)
Os aplicadores clínicos de 90Sr+90Y são instrumentos utilizados em procedimentos de braquiterapia e devem ser calibrados periodicamente, de acordo com normas e recomendações internacionais. Neste trabalho, foram estudados quatro métodos de calibração de aplicadores dermatológicos e oftálmicos, comparando-se os resultados com os fornecidos pelos certificados de calibração dos fabricantes dos aplicadores. Os métodos envolveram o aplicador clínico padrão do Laboratório de Calibração de Instrumentos (LCI), calibrado pelo laboratório padrão primário americano do National Institute of Standards and Technology, como referência; um aplicador da Amersham, também pertencente ao LCI, como referência; uma mini-câmara de extrapolação desenvolvida no IPEN como padrão absoluto; e dosimetria termoluminescente. A mini-câmara de extrapolação e uma câmara de extrapolação comercial PTW foram estudadas com relação ao seu desempenho por meio de testes de controle de qualidade, como corrente de fuga, repetitividade e reprodutibilidade. A distribuição de dose em profundidade na água, estudo de grande importância na dosimetria de aplicadores clínicos, foi determinada utilizando-se a mini-câmara de extrapolação e dosímetros termoluminescentes. Os resultados obtidos foram considerados satisfatórios para os dois casos, quando comparados com os dados fornecidos pela norma IAEA (2002). Além disso, foi desenvolvido um sistema postal dosimétrico para a calibração de aplicadores clínicos por meio da técnica da termoluminescência, para ser enviado para clínicas e hospitais, sem a necessidade do transporte das fontes ao LCI do IPEN para calibração. / 90Sr+90Y clinical applicators are instruments used in brachytherapy procedures and they have to be periodically calibrated, according to international standards and recommendations. In this work, four calibration methods of dermatological and ophthalmic applicators were studied, comparing the results with those given by the calibration certificates of the manufacturers. The methods included the use of the standard applicator of the Calibration Laboratory (LCI), calibrated by the National Institute of Standards and Technology; an Amersham applicator (LCI) as reference; a mini-extrapolation chamber developed at LCI as an absolute standard; and thermoluminescent dosimetry. The mini-extrapolation chamber and a PTW commercial extrapolation chamber were studied in relation to their performance through quality control tests of their response, as leakage current, repetibility and reproducibility. The distribution of the depth dose in water, that presents high importance in dosimetry of clinical applicators, was determined using the miniextrapolation chamber and the thermoluminescent dosimeters. The results obtained were considered satisfactory for the both cases, and comparable to the data of the IAEA (2002) standard. Furthermore, a dosimetry postal kit was developed for the calibration of clinical applicators using the thermoluminescent technique, to be sent to clinics and hospitals, without the need of the transport of the sources to IPEN for calibration.
2

Estudo comparativo entre métodos de calibração de aplicadores clínicos de radiação beta / COMPARATIVE STUDY AMONG CALIBRATION METHODS OF CLINICAL APPLICATORS OF BETA RADIATION

Patrícia de Lara Antonio 03 September 2009 (has links)
Os aplicadores clínicos de 90Sr+90Y são instrumentos utilizados em procedimentos de braquiterapia e devem ser calibrados periodicamente, de acordo com normas e recomendações internacionais. Neste trabalho, foram estudados quatro métodos de calibração de aplicadores dermatológicos e oftálmicos, comparando-se os resultados com os fornecidos pelos certificados de calibração dos fabricantes dos aplicadores. Os métodos envolveram o aplicador clínico padrão do Laboratório de Calibração de Instrumentos (LCI), calibrado pelo laboratório padrão primário americano do National Institute of Standards and Technology, como referência; um aplicador da Amersham, também pertencente ao LCI, como referência; uma mini-câmara de extrapolação desenvolvida no IPEN como padrão absoluto; e dosimetria termoluminescente. A mini-câmara de extrapolação e uma câmara de extrapolação comercial PTW foram estudadas com relação ao seu desempenho por meio de testes de controle de qualidade, como corrente de fuga, repetitividade e reprodutibilidade. A distribuição de dose em profundidade na água, estudo de grande importância na dosimetria de aplicadores clínicos, foi determinada utilizando-se a mini-câmara de extrapolação e dosímetros termoluminescentes. Os resultados obtidos foram considerados satisfatórios para os dois casos, quando comparados com os dados fornecidos pela norma IAEA (2002). Além disso, foi desenvolvido um sistema postal dosimétrico para a calibração de aplicadores clínicos por meio da técnica da termoluminescência, para ser enviado para clínicas e hospitais, sem a necessidade do transporte das fontes ao LCI do IPEN para calibração. / 90Sr+90Y clinical applicators are instruments used in brachytherapy procedures and they have to be periodically calibrated, according to international standards and recommendations. In this work, four calibration methods of dermatological and ophthalmic applicators were studied, comparing the results with those given by the calibration certificates of the manufacturers. The methods included the use of the standard applicator of the Calibration Laboratory (LCI), calibrated by the National Institute of Standards and Technology; an Amersham applicator (LCI) as reference; a mini-extrapolation chamber developed at LCI as an absolute standard; and thermoluminescent dosimetry. The mini-extrapolation chamber and a PTW commercial extrapolation chamber were studied in relation to their performance through quality control tests of their response, as leakage current, repetibility and reproducibility. The distribution of the depth dose in water, that presents high importance in dosimetry of clinical applicators, was determined using the miniextrapolation chamber and the thermoluminescent dosimeters. The results obtained were considered satisfactory for the both cases, and comparable to the data of the IAEA (2002) standard. Furthermore, a dosimetry postal kit was developed for the calibration of clinical applicators using the thermoluminescent technique, to be sent to clinics and hospitals, without the need of the transport of the sources to IPEN for calibration.
3

Desenvolvimento de um sistema de dosimetria para aplicadores de betaterapia de 90Sr+90Y / Dosimetry system development for 90sr+90y betatherapy applicators

Coelho, Talita Salles 17 September 2010 (has links)
Os aplicadores de 90Sr+90Y utilizados no Brasil em betaterapia para prevenção de quelóide e pterígio são importados e suas características dosimétricas são obtidas através de tabelas e manuais dos fabricantes apenas de forma ilustrativa pelos fabricantes. A rotina exaustiva dos profissionais de física médica nos serviços de radioterapia muitas vezes não viabiliza a realização de procedimentos para confirmação destes parâmetros. Este trabalho apresenta o desenvolvimento de uma metodologia para dosimetria de aplicadores de betaterapia de 90Sr+90Y. O software MCNP5 que é baseado no método de Monte Carlo foi utilizado para simulação das curvas de porcentagem de dose profunda e perfis de distribuição de dose produzidos por estes aplicadores. As medidas experimentais da atenuação da radiação, perfil radial e axial, foram realizadas com uma mini-câmara de extrapolação, dosímetros termoluminescentes e filmes radiocrômicos. Os resultados das medidas experimentais foram comparados com os valores simulados. Ambas as curvas de porcentagem de dose profunda e os perfis de distribuição de dose radiais, teóricos e experimentais, apresentaram boa concordância, o que pode validar o uso do software MCNP5 para estas simulações, reforçando a viabilidade do uso deste método nos procedimentos de dosimetria destas fontes emissoras de radiação beta. / The 90Sr+90Y applicators, used in Brazil betatherapy for prevention of keloids and pterigium, are imported and their dosimetric features are obtained through charts and manuals provided only in an illustrated form by the manufacturers. The exhaustive routine of the medical physicists in the clinic often do not make possible the accomplishment of procedures for the confirmation of these parameters. This work presents the development of a methodology for the dosimetry of 90Sr+90Y betatherapy applicators. The MCNP5 software that is based on the Monte Carlo method was used for the simulation of the percentage depth dose curves and dose distribution profiles produced by these applicators. The experimental measurements of the radial and axial radiation attenuation, have been done with a mini-extrapolation chamber, thermoluminescent dosimeters and radiographic films. The experimental results have been compared with the simulated values. Both percentage depth dose curves and the radial dose profiles, the theoretical and the experimental ones, have presented good agreement, which may validate the use of the MCNP5 software for these simulations, confirming the viability of the usage of this method in procedures of beta emitter sources dosimetry.
4

Desenvolvimento de um sistema de dosimetria para aplicadores de betaterapia de 90Sr+90Y / Dosimetry system development for 90sr+90y betatherapy applicators

Talita Salles Coelho 17 September 2010 (has links)
Os aplicadores de 90Sr+90Y utilizados no Brasil em betaterapia para prevenção de quelóide e pterígio são importados e suas características dosimétricas são obtidas através de tabelas e manuais dos fabricantes apenas de forma ilustrativa pelos fabricantes. A rotina exaustiva dos profissionais de física médica nos serviços de radioterapia muitas vezes não viabiliza a realização de procedimentos para confirmação destes parâmetros. Este trabalho apresenta o desenvolvimento de uma metodologia para dosimetria de aplicadores de betaterapia de 90Sr+90Y. O software MCNP5 que é baseado no método de Monte Carlo foi utilizado para simulação das curvas de porcentagem de dose profunda e perfis de distribuição de dose produzidos por estes aplicadores. As medidas experimentais da atenuação da radiação, perfil radial e axial, foram realizadas com uma mini-câmara de extrapolação, dosímetros termoluminescentes e filmes radiocrômicos. Os resultados das medidas experimentais foram comparados com os valores simulados. Ambas as curvas de porcentagem de dose profunda e os perfis de distribuição de dose radiais, teóricos e experimentais, apresentaram boa concordância, o que pode validar o uso do software MCNP5 para estas simulações, reforçando a viabilidade do uso deste método nos procedimentos de dosimetria destas fontes emissoras de radiação beta. / The 90Sr+90Y applicators, used in Brazil betatherapy for prevention of keloids and pterigium, are imported and their dosimetric features are obtained through charts and manuals provided only in an illustrated form by the manufacturers. The exhaustive routine of the medical physicists in the clinic often do not make possible the accomplishment of procedures for the confirmation of these parameters. This work presents the development of a methodology for the dosimetry of 90Sr+90Y betatherapy applicators. The MCNP5 software that is based on the Monte Carlo method was used for the simulation of the percentage depth dose curves and dose distribution profiles produced by these applicators. The experimental measurements of the radial and axial radiation attenuation, have been done with a mini-extrapolation chamber, thermoluminescent dosimeters and radiographic films. The experimental results have been compared with the simulated values. Both percentage depth dose curves and the radial dose profiles, the theoretical and the experimental ones, have presented good agreement, which may validate the use of the MCNP5 software for these simulations, confirming the viability of the usage of this method in procedures of beta emitter sources dosimetry.