• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 24
  • Tagged with
  • 24
  • 24
  • 14
  • 14
  • 14
  • 12
  • 12
  • 10
  • 9
  • 8
  • 8
  • 7
  • 5
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Análise da variação da posição relativa dos dentes artificiais no arco dental em função do processamento de próteses totais mandibulares mensurada por computação gráfica /

Zaze, Cesar Aurélio. January 2005 (has links)
Orientador: Humberto Gennari Filho / Banca: Helena de Freitas Oliveira Paranhos / Banca: Antonio Plese / Resumo: Este trabalho foi idealizado com o intuito de contribuir para os estudos pertinentes à área da prótese total, e teve como objetivo analisar a alteração da posição relativa dos dentes artificiais em razão do processamento de 40 próteses totais inferiores, obtidas por uma matriz de silicone pré-moldada. Na metodologia, as próteses foram divididas em quatro grupos de 10, que receberam os seguintes tratamentos: Grupo 1 - inclusão em muflas metálicas com muralha de gesso pedra tipo III e polimerização em banho de água quente; Grupo 2 - inclusão em muflas de fibra de vidro com muralha de gesso pedra tipo III e polimerização em microondas; Grupo 3 - inclusão em muflas metálicas com muralha de silicone e polimerização em banho de água quente e Grupo 4 - inclusão em muflas de fibra de vidro com muralha de silicone e polimerização em microondas. Como conclusões, os resultados demonstraram que houve alteração na posição dos dentes artificiais em todas as técnicas de processamento, com o grupo 3 apresentando os melhores resultados seguido dos grupos 4, 2 e 1. / Abstract: The purpose of this study is to analyze the change in denture tooth position in the fabrication of complete mandibular dentures after different processing techniques. A total of 40 mandibular complete dentures, obtained by a premolded matrix of silicon, were fabricated. There were a total of four groups of complete mandibular dentures. Each group consisted of 10 complete mandibular dentures which were fabricated in the following manner: Group 1 - were processed in a metallic flask using stone plaster type III and polymerized in hot water; Group 2 - were processed in a fiberglass flask using stone plaster type III and polymerized in a microwave; Group 3 - were processed in a metallic flask using silicon and stone plaster type III and polymerized in hot water; Group 4 - were processed in a fiberglass flask using silicon and stone plaster type III and polymerized in a microwave. In conclusion, the results demonstrated that there were alterations in tooth position in all processing techniques. However, Group 3 presented with the least amount of change in tooth positon, followed by Group 4, then Group 2, and finally Group 1 with the most amount of change in tooth position. / Mestre
12

"Estudo do tamanho dos dentes naturais superiores e dentes artificiais de diferentes marcas comerciais" / Study of the size of the upper natural teeth and of the artificial teeth of different commercial marks

Marina Sayuri Okawa 16 September 2005 (has links)
Neste estudo analisou-se o tamanho de dentes naturais superiores de 119 indivíduos com idade entre 20 e 30 anos. Mediu-se a largura e a altura de todos os dentes superiores em modelos de gesso, com auxílio de um paquímetro digital. Aferiu-se também o tamanho de dentes artificiais de três marcas comerciais. Essa análise permitiu a identificação do que freqüentemente ocorre na dentição natural. Concluiu-se que: aproximadamente 48% dos incisivos centrais superiores naturais possuem a largura maior que 9,0mm. Em contrapartida, somente 14,28% dos incisivos centrais superiores artificiais analisados possuíam essa dimensão. Aproximadamente 64% dos indivíduos da pesquisa possuíam o dente 14 com largura maior que 7,0mm. Nas cartelas de dentes artificiais aferidas, encontrou-se apenas um modelo com dimensão mesiodistal superior a 7,0mm. Cerca de 74% dos primeiros molares superiores naturais possuíam altura menor que 7,0mm. Somente um modelo artificial possui altura menor que 7,0mm. A adequação das dimensões dos dentes artificiais facilitaria a montagem dos dentes e traria a estética almejada ao portador de reabilitações protéticas. / In this study, the size of natural maxillary teeth of 119 individuals between 20 and 30 years old were analyzed. The width and the height of all of the upper teeth on the casts were measured with a digital caliper. The size of the artificial teeth of three commercial marks was also checked. That analysis allowed the identification of what frequently occurs in the natural dentition. The conclusion was that: approximately 48% of the width of natural maxillary central incisor was greater than 9,0mm. However, only 14,28% of the artificial central upper incisor analyzed had that dimension. Approximately 64% of the population in the research had tooth 14 with width larger than 7,0mm. In the moulds of the teeth available, was found only a model with mesiodistal dimension over 7,0mm. Around 74% of the height of natural maxillary first molars was smaller than 7,0mm. Only an artificial model had height smaller than 7,0mm. The adaptation of the dimensions by artificial teeth would facilitate the assembly of the teeth and would bring the esthetics desired for to the user of the prosthetic replacements.
13

"Estudo comparativo da largura dos dentes naturais anteriores superiores em ralação aos dentes artificiais para prótese total" / Comparative study between upper anterior natural teeth and artificial teeth for complete dentures

Max Dalla Kiausinis 14 September 2005 (has links)
Estudou-se a largura dos dentes anteriores superiores de 121 jovens universitários brasileiros para determinar quais modelos e qual marca de dentes artificiais seriam os mais adequados para este grupo. As arcadas dentais completas foram moldadas com alginato e vazadas em gesso especial na parte oclusal e gesso pedra na base. Os dentes não apresentavam nenhum sinal de abrasões anormais, restaurações ou deformidades. A saúde periodontal era boa com mínima ou nenhuma retração gengival, inflamação ou hipertrofia. Os dentes dos modelos em gesso e os artificiais tiveram sua dimensão mesio-distal (largura) mensurada com um paquímetro digital. Não foi observada diferença significativa entre os sexos e entre as hemi-arcadas direita e esquerda com relação à largura dos dentes anteriores superiores. Das marcas analisadas nenhuma foi considerada apropriada para o grupo em questão devido ao fato de possuírem poucas opções de modelos e estes serem fabricados em tamanhos predominantemente pequenos enquanto que os dentes naturais mostraram-se predominantemente maiores (mais largos), o que nos apontou à necessidade de se adaptar ou criar modelos que sejam mais adequados à realidade brasileira. / It was studied the width of upper anterior teeth in 121 Brazilian college students intending to determine which models and brands would be more adequate to such group. The whole dental arch was molded with alginate and stone type four was poured in the oclusal surface of teeth while stone type two was poured in the left parts. Those teeth did not present abnormal abrasions, fillings or deformities. Periodont was healthy presenting little or none gengival retraction, inflamation or hipertrophy. Both stone models and artificial teeth had their mesio-distal distance (width) measured by a digital caliper rule. It was not observed significant difference between genders or right and left hemi-arches when comparing to the upper anterior teeth’s width. Considering the analyzed brands none was considered appropriate to such group because there were little options besides sizes being considered too small when compared to natural teeth, which pointed to the necessity to adapt or to create models more adequate to the Brazilian reality.
14

Análise do comportamento do coeficiente de desgaste nas diferentes camadas dos Dentes de Resina Acrílica / Analysis of the behavior of wear coefficient in the different layers of Acrylic Resin Teeth

Uehara, Priscila Nakasone 08 June 2016 (has links)
O objetivo desse estudo foi analisar o comportamento de desgaste das camadas correspondentes ao esmalte e à dentina. Foram utilizados incisivos centrais superiores de seis modelos comerciais de dentes artificiais para confecção dos corpos de prova (Premium, Magister, Vivodent PE, Biotone, Artiplus IPN e Trilux). O número total de amostras foi igual a cinco para cada marca comercial Para analisar o coeficiente de desgaste dos dentes artificiais o ensaio de desgaste micro-abrasivo foi em função da Distância de deslizamento (S) e da Força normal (N), sob condições de N constante. As crateras de desgaste foram realizadas sem paradas intermediárias para obtenção da evolução do diâmetro da cratera em função do tempo de ensaio. Os tempos de ensaio foram: 5; 8,33 e 11,66 minutos, os pontos para realização dos ensaios foram escolhidos aleatoriamente. Para cada condição de ensaio foram realizadas cinco repetições. As crateras foram analisadas por meio de microscópio óptico e as medições foram realizadas por meio do software ©Leica Microsytems. Para todas as análises, a normalidade da distribuição dos dados e a homogeneidade foram testadas. Análise de Variância (ANOVA) 2-fatores e o Teste de Tukey para comparações múltiplas foram calculados a partir dos valores obtidos no t3. O menor e maior valor obtido de k foram respectivamente k=22,60.10?? (Ar) e k=47,8.10?? (Ma). Para os fatores marca (p=0.0012) e região (p=0.028) as diferenças foram estatisticamente significantes, no entanto para marca x região (p=0.16) não houve diferença significante. De acordo com os resultados apresentados, conclui-se que o comportamento observado do coeficiente de desgaste em todas as amostras, esmalte e dentina, teve como mecanismo o riscamento. Também, foi possível estabelecer diferenças do comportamento ao desgaste dos dentes artificiais de resina acrílica de diferentes marcas comerciais e suas camadas. E o ensaio de micro abrasão com esfera rotativa fixa é apropriado para o estudo de materiais poliméricos utilizados na Odontologia. / The aim of this study was to analyze the wear behavior of the layers of artificial teeth corresponding to the enamel and dentine by means of micro-abrasive wear with \"ballcratering\". Upper central incisors of six artificial teeth commercial brands were used to confection of the test specimens (Premium, Magister, Vivodent PE, Biotone, Artiplus IPN e Trilux). The total number of samples was five to each commercial brand. To analyze the artificial teeth wear coefficient, the micro-abrasive wear testing was performed according to Distance sliding (S) and normal Force (N), under conditions of constant N. The wear craters were made without intermediate stops in order to obtain the evolution of craters diameter in accordance to in the experiment duration. The testing times were: 5; 8,33 and 11,66 minutes, the points to the testing execution were chosen randomly. Three repetitions were used for each testing condition. Craters were analyzed with optical microscopes and measurements were taken with the software ©Leica Microsytems. For all analyses data distribution normality and homogeneity were tested. \"Analysis of Variance\" (ANOVA) 2- factors and Tukey Test to multiple comparisons were calculated from the obtained values in t3. The lowest and biggest values obtained of k were k=22,60.10?? (Ar) and k=47,8.10?? (Ma), respectively. In relation to brand factors (p=0.0012) and region (p=0.028) the differences were statistically significant, however regarding to brand x region (p=0.16) there was no significant difference. According to the results, it can be concluded that the behavior of the wear coefficient in all samples, enamel and dentin presented grooving abrasion. Also, it was possible to observe differences in wear behavior of brands of acrylic resin artificial teeth and its layers. The micro-abrasive wear with \"ball-cratering\" test is appropriate for the study of polymeric materials in Dentistry.
15

Avaliação da angulação do sulco de trabalho de dentes artificiais em relação ao plano de orientação e ao eixo de rotação vertical de lateralidade da mandíbula no articulador / Evaluation of the relationship amongst the working groove angulation of artificial teeth and the orientation plane and the vertical rotation axis of mandibular lateral translation in the articulator

Furuyama, Ricardo Jun 22 September 2006 (has links)
Na reabilitação protética, a oclusão e os movimentos mandibulares estão intrinsecamente ligados. A harmonia entre estes dois fatores torna-se indispensável para o sucesso do tratamento. Um dos conceitos sempre abordados na busca deste ideal é a relação entre os sulcos e as cúspides dos dentes com os movimentos mandibulares, onde as segundas devem passar livremente sobre os primeiros durante a movimentação mandibular. Assim, foi proposto avaliar o grau de coincidência da angulação do sulco de trabalho do primeiro molar inferior artificial, quando posicionado no arco, em relação à trajetória descrita pela cúspide mésiopalatina do primeiro molar superior em relação ao eixo de rotação vertical de lateralidade da mandíbula no articulador semi-ajustável. O autor utilizou uma metodologia que permitiu identificar esta trajetória com o auxílio de um programa de editoração gráfica. Foi possível avaliar as imagens digitais de montagens em cera de dentes artificiais em prótese totais inferiores e de seus respectivos planos de orientação posicionados em articulador. Através das imagens, localizou-se o sulco de trabalho do primeiro molar inferior, a trajetória da cúspide mésio-palatina do primeiro molar superior adotando-se o eixo de rotação vertical no centro das esferas condilares, e a perpendicular à tangente ao plano de orientação. Assim, mediu-se o ângulo formado entre a perpendicular à tangente e o sulco de trabalho e o ângulo entre a trajetória do eixo de rotação vertical e o sulco de trabalho. Os resultados mostraram que houve casos onde o sulco de trabalho coincidiu com a perpendicular à tangente do plano de orientação, nos demais casos a angulação apresentou, em média, valores baixos demonstrando que as montagens dos dentes artificiais seguiram os parâmetros adotados no plano de orientação segundo a técnica proposta. Estatisticamente, a distância intercondilar não interferiu nas médias dos ângulos entre o sulco de trabalho e a trajetória do eixo vertical de rotação. Não foi observada a coincidência entre o sulco de trabalho e a trajetória do eixo de rotação vertical, indicando que, durante a reprodução do movimento de lateralidade no articulador, ocorre interferência na excursão da cúspide mésio-palatina do primeiro molar superior. / In prosthetic rehabilitation, occlusion and mandibular movements are closely linked. Harmony between these factors is essential for treatment success. One of the main concepts approached when aiming for this goal is the relationship between teeth grooves and cuspids and mandibular movements, where cuspids must not touch grooves during these movements. Therefore, the present study proposes to evaluate the degree of coincidence of the working groove angulation from the artificial mandibular first molar, when positioned on the arch, with the trajectory traced by the mesio-palatal cuspid from the maxillary first molar during mandibular lateral translation determined by the vertical axis rotation in a semi-adjustable articulator. To identify this trajectory, the author utilized a graphical editing program. It was possible to evaluate digital images from artificial teeth mounted on wax for mandibular complete dentures, and their respective orientation planes positioned on the articulator. Through these images, the author located the working groove from the mandibular first molar, the trajectory described by the mesio-palatal cuspid from the maxillary first molar considering the vertical axis rotation at the center of the condilar spheres, and the perpendicular to the tangent of orientation plane. Thus, the angle between the perpendicular to the tangent and working groove and the angle between the trajectory of the vertical axis rotation and the working groove were measured. The results showed some cases where the working groove coincided with the perpendicular to the tangent of the orientation plane. In the remaining cases, the angulation displayed low mean values, illustrating that the mounting of artificial teeth followed the parameters adopted for the orientation plane according to the proposed technique. The distance between condoles did not significantly interfere in the mean values for the angles between the working groove and the trajectory of the vertical axis rotation. The coincidence between the working groove and the trajectory of the vertical axis rotation was not observed, indicating that, during the lateral translation movement in the articulator, there is interference in the trajectory of the maxillary first molar mesio-palatal cuspid.
16

Viabilidade da substituição de raízes de dentes humanos por raízes construídas em compósito para estudos de mecânica da fratura / Viability of replacing the roots of human teeth by roots made of composite for the study of fracture mechanics

Espósito, Camila Oliveira Moraes 27 April 2012 (has links)
OBJETIVO: A restauração de dentes tratados endodonticamente é um desafio para a Odontologia. A fratura do remanescente radicular é comum neste tratamento. São três os métodos utilizados para estudar as fraturas: a análise por elementos finitos, os que utilizam dentes naturais e aqueles que utilizam dentes artificiais. O uso de dentes naturais apresenta alguns inconvenientes, como as variações anatômicas e de histórico de exposição a esforços (que aumentam a variabilidade da amostra e dificultam as conclusões), além da pequena disponibilidade de espécimes. Este estudo propõe-se avaliar a viabilidade de usar compósito para a construção de raízes artificiais e a aplicação dessas réplicas em estudos sobre a essas fraturas. MÉTODOS: Na primeira etapa foram utilizadas 50 raízes unirradiculares de 2º pré-molar superior e 50 réplicas. As raízes naturais foram selecionadas por terem características anatômicas semelhantes. As réplicas foram confeccionadas a partir de um molde de resina acrílica que copiou uma raiz natural com proporções dentro da média. O compósito foi escolhido pelas propriedades mecânicas mais próximas das propriedades mecânicas da dentina. Todas as raízes e as réplicas foram submetidas a forças compressivas de uma ponta metálica cônica (simulação do pino intrarradicular), até a fratura. A velocidade de avanço da ponta foi de 5mm/min. Na segunda etapa, foram confeccionadas 30 réplicas, divididas em 3 grupos (n=10). Todas foram restauradas com pinos metálicos fundidos e coroas metálicas. No grupo FZ os pinos foram cimentados com fosfato de zinco; no grupo CRD foi aplicada uma camada de vaselina sólida no conduto radicular e os pinos foram cimentados com cimento resinoso dual; no grupo CRC foi feita aplicação de um agente de união no conduto radicular e os pinos foram cimentados com cimento resinoso dual. Os espécimes foram submetidas a ciclagem mecânica de 130.000 ciclos sob pressão de 5bar. Duas raízes de cada grupo foram utilizadas para testar os parâmetros do ensaio de resistência à fratura. Em seguida, as outras raízes (n=8) foram submetidas ao teste de resistência sob forças compressivas até a ruptura. A carga foi aplicada com inclinação de 20º e velocidade de 5mm/min. RESULTADOS: Na comparação entre a resistência das raízes naturais e artificiais à penetração de pino no conduto radicular, houve diferença estatística entre os dois grupos. As raízes artificiais apresentam maior resistência à fratura (115,4MPa) do que as raízes naturais (75,4MPa). O coeficiente de variação das réplicas (21%) é menor que o das raízes naturais (36,3%), o que indica uma menor variabilidade da amostra das réplicas. Mesmo com valores diferentes, há semelhança na direção do traço de fratura e no local onde ocorrem. Esse resultado indica que a concentração de tensões e a propagação da fratura é semelhante em dentina e compósito. Quanto às réplicas restauradas com pinos, não houve diferença estatística entre os grupos. CONCLUSÃO: As raízes artificiais quando comparadas as raízes naturais, apresentam maior resistência à fratura, menor variação dos resultados individuais em torno da média e modo de fratura semelhante às raízes naturais. Desta maneira, é viável a utilização das réplicas nos estudos sobre mecânica da fratura. / OBJECTIVE: The restoration of endodontically treated teeth is a challenge for dentistry. The fracture of the remaining root is common in this treatment. There are three methods used to study fractures: a finite element analysis, using the natural teeth and those who use artificial teeth. The use of natural teeth has some disadvantages, such as anatomical variations and a history of exposure to stresses (which increase the variability of the sample and the findings difficult), beyond the limited availability of specimens. This study aims to evaluate the feasibility of using composite for the construction of artificial roots and application of these replicas in studies of these fractures. METHODS: In the first stage were used 50 single-rooted roots of 2nd premolar and 50 replicas. The natural roots were selected for having similar anatomical features. The replicas were made from an acrylic resin such that a natural root copied with ratios in the average. The composite was selected by the mechanical properties closer to the mechanical properties of the dentin. All the roots and the replicas were subjected to compressive forces of a conical metal tip (simulation post) until failure. The feed rate was tip of 5mm/min. In the second step, 30 replicas were prepared, divided into 3 groups (n = 10). All were filled with molten metal pins and metal crowns. In group A the posts were cemented with zinc phosphate, group B was applied to a solid layer of vaseline in the root canal and the posts were cemented with dual resin cement, in group C was made applying a bonding agent in the root canal and the posts were cemented with dual resin cement. The specimens were subjected to mechanical loading of 130,000 cycles under a pressure of 5bar. Two roots from each group were used to test the parameters of fracture toughness test. Then the other root (n = 8) were subjected to endurance test under compressive forces until failure. The load was applied with an inclination of 20° and speed 5mm/min. RESULTS: Comparing the resistance of natural and artificial root penetration of the pin in the root canal, was no statistical difference between the two groups. The artificial roots showed higher fracture strength (115.4 MPa) than the natural roots (75.4 MPa). The coefficient of variation of the replicas (21%) is less than the natural root (36.3%), indicating a lower variability of the replicas of the sample. Even with different values, there are similarities in the direction of the fracture site and where they occur. This result indicates that the stress concentration and fracture propagation is similar in dentin and composite. As for replicas restored with posts, no statistical difference between groups was found. CONCLUSION: The artificial roots showed greater resistance to fracture when compared to natural roots, less variation of individual results around the mean and mode of fracture similar to the natural roots. Thus, it is feasible to use in studies of replicas of fracture mechanics.
17

Técnica de replicação de raízes dentárias em resina composta fotopolimerizável a partir de molde de resina acrílica autopolimerizável / Root tooth replication technique in photo polymerized composite resin made by means of an acrylic resin mold by self polymerized resin

Camargo, Sergio Luiz da Silveira 08 February 2011 (has links)
Pelas fraturas que sofrem os dentes caninos, torna-se necessário tratá-los endodonticamente, e repará-los proteticamente. Porém, novas fraturas coronais, com ou sem perda de coroa metálica podem se repetir. Muitas técnicas restauradoras priorizam os dentes com maior percentual de porção coronal, porque a extensa área de coroa remanescente assegura execução facilitada, favorecendo a recuperação do elemento dental e garantindo sucesso do assentamento da peça metálica. As pesquisas realizadas para se conseguir novos tratamentos utilizam dentes naturais para simular a realidade. Não há banco de dentes rotineiro na Odontologia Veterinária. O uso de dentes naturais de animais encontra restrições por conta da grande diversidade de raças e de porte entre cães, consequentemente no tamanho e na anatomia dos dentes. Existe ainda a carência de disponibilidade de amostras naturais na quantidade necessária para desenvolver tais estudos. O material artificial capaz de substituir os dentes naturais pode estar nas resinas compostas fotopolimerizáveis que apresentam propriedades mecânicas semelhantes às da dentina. Para se replicar o dente natural em resina composta, foi criado um molde em resina acrílica transparente. A literatura deste assunto é escassa ou mesmo inexiste. Com a construção de dentes artificiais muitas pesquisas podem ser realizadas, pois as amostras dentárias serão padronizadas de acordo com a necessidade de cada estudo a ser desenvolvido. Neste trabalho objetivou-se reproduzir quarenta dentes artificiais (réplicas) para demonstrar a possibilidade do padrão de cópia a partir do uso de um molde de resina acrílica. Os resultados mostraram que as réplicas foram similares ao dente natural. / Due to the fractures that canine teeth suffer, it is necessary to treat these teeth endodonticaly and restore them prosthetically (with pin, post core and metallic crown) in its coronal portion. However a new coronal fracture can happen with or without loss of the prosthodontic work. Many of the techniques aim at the teeth with larger extension of remaining area of crown, which favors the crown preparation and fixation of the prosthesis. Many researches use natural teeth to simulate the real conditions. In Veterinary Dentistry there is no routine bank of teeth. However there is a variety of dog breeds with different sizes, as well as a great variety in extension of the teeth. Additionally there is large numbers of natural teeth available enough for use in all researches. The material that can substitute the natural teeth seems to be the photo polymerized composite resin, which has similar mechanical properties to dentin. To replicate the natural teeth in composite resin, a mold was created in acrylic transparent resin. Literature of this subject is spares or inexistent. With artificial replication of teeth many researches can be achieved, once the samples of teeth can be standardized, according to which study. This project aimed to reproduce 40 replicas to demonstrate the possibility of copy from a transparent acrylic mold. Results showed that the replicas were similar to the natural tooth.
18

Avaliação dos efeitos adversos de soluções desinfetantes nas propriedades físicas e mecânicas de materiais para confecção de próteses totais / Evaluation of the adverse effects of disinfectant solutions on the physical and mechanical properties of materials for making complete dentures

Bueno, Frank Lucarini 23 January 2017 (has links)
O estudo avaliou os efeitos adversos de soluções desinfetantes sobre a dureza, alteração de cor, sorção e solubilidade, resistência à flexão, rugosidade e resistência ao impacto de uma resina acrílica e dentes artificiais. Microscopia confocal a laser foi utilizada para análise de superfície. Através da concentração inibitória mínima (CIM), utilizando o método de micro diluições, foi determinada a concentração de 0,15% para a solução de Triclosan e 0,25% para a Cloramina T. As variáveis foram mensuradas antes e após a imersão dos espécimes nas soluções. Os corpos de prova em resina acrílica termicamente ativada e os dentes artificiais foram distribuídos em grupos (n=10): GC = água destilada; GHS = Hipoclorito de sódio a 0,25%; GT = Solução de Triclosan a 0,15%; GCt = Solução de Cloramina T a 0,25%; GRc2 = solução de R. communis a 2%; GRc10 = solução de R. communis a 10%; GS = Sabonete Antisséptico. Os corpos de prova foram imersos em 100 mL de cada solução, simulando imersões diárias de 20 minutos por 5 anos. Os dados foram submetidos aos Testes ANOVA e Duncan ou ANOVA e Tukey (p=0,05). Para resina acrílica, todos os grupos diminuíram a dureza, tendo GC causado a maior diminuição (p=0,001). Nos demais grupos a diminuição da dureza foi semelhante. O grupo GRc2 apresentou a maior alteração de cor, enquanto o GCt causou a menor. Os demais grupos apresentaram valores intermediários (p=0,043). Em relação à sorção, o grupo GRc2 seguido do GC apresentaram maior valor de sorção e os grupos GT e GS, os menores. Para a solubilidade, os grupos GC, GHS, GCt, GT e GS apresentaram os maiores valores, e o grupo GRc2 seguido do GRc10 apresentou o menor valor (p=0,001). O menor valor de resistência a flexão foi verificado no GRc2, enquanto os grupos GC e GCt apresentaram os maiores valores (p=0,000). Os demais grupos apresentaram valores intermediários. Todas as soluções causaram diminuição da rugosidade exceto os grupos Rc10 e GC (p=0,001). Os grupos GS, GT e GCt apresentaram os maiores valores de resistência ao impacto, e o GRc10 apresentou o menor valor (p=0,000). Já para os dentes, houve aumento da dureza em todos os grupos, tendo os grupos GHS e GC causado maior alteração (p=0,000). Os grupos GS e GRc2 apresentaram a maior alteração de cor, enquanto os grupos GC, GCt e GT apresentaram as menores (p=0,000). Os grupos GC, GRc2 e GRc10 apresentaram os maiores valores de sorção e os grupos GT e GS os menores. Para a solubilidade, os grupos GRc10 e GRc2 apresentaram os maiores valores e os grupos GT e GS, os menores. A variação da rugosidade dos dentes indicou que todas as soluções causaram diminuição da rugosidade exceto o grupo GT. A maior variação de rugosidade foi causada pela solução de Rc10 (p=0,001). No período avaliado, todas as propriedades sofreram alterações em função das soluções de desinfecção avaliadas após simulação de imersões diárias de 20 minutos por 5 anos, porém todas as variáveis estudas apresentaram valores clinicamente aceitáveis, exceto a alteração de cor. / This study evaluated the adverse effects of disinfectant solutions on hardness, color change, sorption and solubility, flexural strength, roughness and impact strength of an acrylic resin and artificial teeth. Confocal laser microscopy was used for surface analysis. The minimum inhibitory concentration (MIC) using the microdilution method determined the concentration of 0.15% for the Triclosan solution and 0.25% for the Chloramine T. Variables were measured before and after immersion of the specimens in the solutions. The thermally activated acrylic resin specimens and the artificial teeth were distributed in groups (n = 10): GC = distilled water; GHS = 0.25% Sodium hypochlorite; GT = 0.15% Triclosan solution; GCt = 0.25% Chloramine T solution; GRc2 = 2% R. communis solution; GRc10 = 10% R. communis solution; GS = Antiseptic Soap. The specimens were immersed in 100 mL of each solution, simulating daily immersions of 20 minutes for 5 years. The data obtained were submitted to ANOVA and Duncan tests or ANOVA and Tukey tests (p = 0.05). For acrylic resin, all groups decreased hardness and GC showed the greatest decrease (p = 0.001). In the other groups the decrease in hardness was similar. The GRc2 group presented the greatest color change, while the GCt, the lowest. The other groups presented intermediate values (p = 0.043). In relation to the sorption, the GRc2 group followed by the GC presented higher sorption value and the GT and GS groups, the smaller. For solubility, GC, GHS, GCt, GT and GS presented the highest values, and the GRc2 group followed by GRc10 had the lowest value (p = 0.001). The GRc2 showed a lower value of flexural strength, while GC and GCt had the highest values (p = 0.000). The other groups presented intermediate values. All solutions caused a decrease in roughness except the groups Rc10 and GC (p = 0.001). The groups GS, GT and GCt had the highest values of impact resistance, and the GRc10 had the lowest value (p = 0.000). For the teeth, there were an increase on hardness in all groups, and the GHS and CG groups showed a greater change (p = 0.000). The GS and GRc2 groups had the highest color change, while the GC, GCt and GT groups showed the lowest (p = 0.000). The GC, GRc2 and GRc10 groups had the highest sorption values and the GT and GS groups had the lowest values. For the solubility, the GRc10 and GRc2 groups had the highest values and the GT and GS groups, the lowest. The variation of the roughness of the teeth indicated that all solutions caused a decrease in roughness except for the GT group. The highest roughness variation was caused by the Rc10 solution (p = 0.001). In the evaluated period, all the properties were altered as a function of the disinfection solutions evaluated after simulation of daily immersions of 20 minutes for 5 years, however all variables studied presented clinically acceptable values, except for color change.
19

Avaliação dos efeitos adversos de soluções desinfetantes nas propriedades físicas e mecânicas de materiais para confecção de próteses totais / Evaluation of the adverse effects of disinfectant solutions on the physical and mechanical properties of materials for making complete dentures

Frank Lucarini Bueno 23 January 2017 (has links)
O estudo avaliou os efeitos adversos de soluções desinfetantes sobre a dureza, alteração de cor, sorção e solubilidade, resistência à flexão, rugosidade e resistência ao impacto de uma resina acrílica e dentes artificiais. Microscopia confocal a laser foi utilizada para análise de superfície. Através da concentração inibitória mínima (CIM), utilizando o método de micro diluições, foi determinada a concentração de 0,15% para a solução de Triclosan e 0,25% para a Cloramina T. As variáveis foram mensuradas antes e após a imersão dos espécimes nas soluções. Os corpos de prova em resina acrílica termicamente ativada e os dentes artificiais foram distribuídos em grupos (n=10): GC = água destilada; GHS = Hipoclorito de sódio a 0,25%; GT = Solução de Triclosan a 0,15%; GCt = Solução de Cloramina T a 0,25%; GRc2 = solução de R. communis a 2%; GRc10 = solução de R. communis a 10%; GS = Sabonete Antisséptico. Os corpos de prova foram imersos em 100 mL de cada solução, simulando imersões diárias de 20 minutos por 5 anos. Os dados foram submetidos aos Testes ANOVA e Duncan ou ANOVA e Tukey (p=0,05). Para resina acrílica, todos os grupos diminuíram a dureza, tendo GC causado a maior diminuição (p=0,001). Nos demais grupos a diminuição da dureza foi semelhante. O grupo GRc2 apresentou a maior alteração de cor, enquanto o GCt causou a menor. Os demais grupos apresentaram valores intermediários (p=0,043). Em relação à sorção, o grupo GRc2 seguido do GC apresentaram maior valor de sorção e os grupos GT e GS, os menores. Para a solubilidade, os grupos GC, GHS, GCt, GT e GS apresentaram os maiores valores, e o grupo GRc2 seguido do GRc10 apresentou o menor valor (p=0,001). O menor valor de resistência a flexão foi verificado no GRc2, enquanto os grupos GC e GCt apresentaram os maiores valores (p=0,000). Os demais grupos apresentaram valores intermediários. Todas as soluções causaram diminuição da rugosidade exceto os grupos Rc10 e GC (p=0,001). Os grupos GS, GT e GCt apresentaram os maiores valores de resistência ao impacto, e o GRc10 apresentou o menor valor (p=0,000). Já para os dentes, houve aumento da dureza em todos os grupos, tendo os grupos GHS e GC causado maior alteração (p=0,000). Os grupos GS e GRc2 apresentaram a maior alteração de cor, enquanto os grupos GC, GCt e GT apresentaram as menores (p=0,000). Os grupos GC, GRc2 e GRc10 apresentaram os maiores valores de sorção e os grupos GT e GS os menores. Para a solubilidade, os grupos GRc10 e GRc2 apresentaram os maiores valores e os grupos GT e GS, os menores. A variação da rugosidade dos dentes indicou que todas as soluções causaram diminuição da rugosidade exceto o grupo GT. A maior variação de rugosidade foi causada pela solução de Rc10 (p=0,001). No período avaliado, todas as propriedades sofreram alterações em função das soluções de desinfecção avaliadas após simulação de imersões diárias de 20 minutos por 5 anos, porém todas as variáveis estudas apresentaram valores clinicamente aceitáveis, exceto a alteração de cor. / This study evaluated the adverse effects of disinfectant solutions on hardness, color change, sorption and solubility, flexural strength, roughness and impact strength of an acrylic resin and artificial teeth. Confocal laser microscopy was used for surface analysis. The minimum inhibitory concentration (MIC) using the microdilution method determined the concentration of 0.15% for the Triclosan solution and 0.25% for the Chloramine T. Variables were measured before and after immersion of the specimens in the solutions. The thermally activated acrylic resin specimens and the artificial teeth were distributed in groups (n = 10): GC = distilled water; GHS = 0.25% Sodium hypochlorite; GT = 0.15% Triclosan solution; GCt = 0.25% Chloramine T solution; GRc2 = 2% R. communis solution; GRc10 = 10% R. communis solution; GS = Antiseptic Soap. The specimens were immersed in 100 mL of each solution, simulating daily immersions of 20 minutes for 5 years. The data obtained were submitted to ANOVA and Duncan tests or ANOVA and Tukey tests (p = 0.05). For acrylic resin, all groups decreased hardness and GC showed the greatest decrease (p = 0.001). In the other groups the decrease in hardness was similar. The GRc2 group presented the greatest color change, while the GCt, the lowest. The other groups presented intermediate values (p = 0.043). In relation to the sorption, the GRc2 group followed by the GC presented higher sorption value and the GT and GS groups, the smaller. For solubility, GC, GHS, GCt, GT and GS presented the highest values, and the GRc2 group followed by GRc10 had the lowest value (p = 0.001). The GRc2 showed a lower value of flexural strength, while GC and GCt had the highest values (p = 0.000). The other groups presented intermediate values. All solutions caused a decrease in roughness except the groups Rc10 and GC (p = 0.001). The groups GS, GT and GCt had the highest values of impact resistance, and the GRc10 had the lowest value (p = 0.000). For the teeth, there were an increase on hardness in all groups, and the GHS and CG groups showed a greater change (p = 0.000). The GS and GRc2 groups had the highest color change, while the GC, GCt and GT groups showed the lowest (p = 0.000). The GC, GRc2 and GRc10 groups had the highest sorption values and the GT and GS groups had the lowest values. For the solubility, the GRc10 and GRc2 groups had the highest values and the GT and GS groups, the lowest. The variation of the roughness of the teeth indicated that all solutions caused a decrease in roughness except for the GT group. The highest roughness variation was caused by the Rc10 solution (p = 0.001). In the evaluated period, all the properties were altered as a function of the disinfection solutions evaluated after simulation of daily immersions of 20 minutes for 5 years, however all variables studied presented clinically acceptable values, except for color change.
20

Análise da variação da posição dos dentes artificiais durante as fases específicas do processamento de próteses totais superiores mensurada por computação gráfica

Shibayama, Ricardo [UNESP] 23 March 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-03-23Bitstream added on 2014-06-13T19:24:19Z : No. of bitstreams: 1 shibayama_r_dr_araca.pdf: 1447114 bytes, checksum: 3c09de09a6fe8d140870e923ba0cd69a (MD5) / Foi investigada a alteração da posição dos dentes artificiais durante o processamento de próteses totais desde a fase de enceramento até o polimento, utilizando as resinas de marcas comerciais QC 20 (Dentsply) e Onda Cryl (Clássico - específico para microondas), com inclusão em gesso tipo II e com muralha de silicone, polimerizadas tanto pelo método de banho em água quente, quanto pela polimerização por energia de microondas. Foram utilizadas 40 amostras, obtidas de um modelo padrão e divididas em 4 grupos de 10, que receberam os seguintes tipos de processamento. a) grupo 1: incluídos em muflas metálicas com muralha de gesso pedra e polimerização por banho de água quente. b) grupo 2: incluídos em muflas de fibra de vidro com muralha de gesso pedra e polimerização por microondas. c) grupo 3: incluídos em muflas metálicas com muralha de silicone e polimerização por banho em água quente. d) grupo 4: incluídos em muflas de fibra de vidro com muralha de silicone e polimerização por energia de microondas. Para detecção dos deslocamentos dentais utilizou-se um guia de resina acrílica com 5 pontos pré-determinados nas cúspides dos dentes que proporcionaram pontos de referência nas réplicas permitindo mensurar tais deslocamentos através da digitalização das superfícies oclusais dos dentes e analisados por um programa de computador AutoCad. Baseados nos resultados obtidos, de acordo com os materiais e metodologia empregados, concluimos que: 1. Em todas as técnicas de processamento de prótese total estudadas houve alteração da posição dos dentes após o processamento. 2. A técnica de inclusão com muralha de silicone e polimerização por microondas (grupo 4) apresentou os menores valores de alterações na posição dos dentes durante toda a fase de processamento... / Artificial teeth position changes were investigated during the upper complete denture processing, resins QC 20 (Dentsply) and Onda Cryl (Clássico - specific for microwave energy) were used and flasked in type II gypsum stone mould or silicone mould, polymerized in hot water bath as well in microwave polymerization. Forty specimens were used, which were obtained from one standard cast, and divided into four groups of ten that were processed as the following: a) group I (control): flasked in metallic muffles with gypsum stone barrier and conventional polymerization. b) group II: flasked in glass fiber muffles with gypsum stone barrier and polymerization by microwave energy. c) group III: flasked in metallic muffles with silicone barrier and conventional polymerization. d) group IV: flasked in glass fiber muffles with silicone barrier and microwave polymerization. An acrylic resin guide was used to detect teeth displacements, this guide was marked with 5 predetermined points in teeth cuspids that has proportionate reference points in the replicas. These points were used to measure, by AutoCad software, teeth displacements by digitized occlusal surface of the teeth. Based upon the results, according to the employed material and method, the following can be concluded: 1. It was observed teeth position changes after denture processing in all experimental groups. 2. The technique of flasking with silicone mould and microwave polymerization (group 4) presented minor degree of teeth position changes during all the processing. 3. The segments that constitute the smaller triangle represented by the points of teeth 15, 21 and 25 showed more homogeneity and linearity than the bigger triangle represented by the cuspids of 17, 21 and 27. 4. These dimensional changes of shrinkage and expansion in both triangles followed a uniform sequence for all the segments, that is, as one segment changes, the others follow it, thus, they don t occur randomly.

Page generated in 0.0807 seconds