Design and evaluation of a portable device for the measurement of bio-impedance cardiography

Shi, Qinghai, Heinig, Andreas, Kanoun, Olfa 29 March 2011 (has links) (PDF)
Electrical impedance of biological matter is known as electrical bio-impedance or simply as bio-impedance. Bio-impedance devices are of great value for monitoring the pathological and physiological status of biological tissues in clinical and home environments. The technological progress in instrumentation has significantly contributed to the progress that has been observed during the last past decades in impedance spectroscopy and electrical impedance cardiograph. Although bio-impedance is not a physiological parameter, the method enables tissue characterization and functional monitoring and can contribute to the monitoring of the health status of a person. In this paper an inexpensive portable multi frequency impedance cardiograph device based on impedance spectroscopy technique has been developed. By means of this system the basic thoracic impedance range and the heart-action-caused changes of impedance can be measured and the hemodynamic parameters of the heart function can be determined. This system has small size and low current consumption. The impedance cardiograph signals of the electrodes configuration by Sramek, Penney and Qu in this work was measured; compared and summarized. The differences of the measuring method, the schematic circuit diagram, the measurement results and area of application between impedance cardiograph and impedance spectroscopy were discussed and compared. The performance of this sensor-system was evaluated.
12

Design and evaluation of a portable device for the measurement of bio-impedance cardiography

Shi, Qinghai, Heinig, Andreas, Kanoun, Olfa 29 March 2011 (has links)
Electrical impedance of biological matter is known as electrical bio-impedance or simply as bio-impedance. Bio-impedance devices are of great value for monitoring the pathological and physiological status of biological tissues in clinical and home environments. The technological progress in instrumentation has significantly contributed to the progress that has been observed during the last past decades in impedance spectroscopy and electrical impedance cardiograph. Although bio-impedance is not a physiological parameter, the method enables tissue characterization and functional monitoring and can contribute to the monitoring of the health status of a person. In this paper an inexpensive portable multi frequency impedance cardiograph device based on impedance spectroscopy technique has been developed. By means of this system the basic thoracic impedance range and the heart-action-caused changes of impedance can be measured and the hemodynamic parameters of the heart function can be determined. This system has small size and low current consumption. The impedance cardiograph signals of the electrodes configuration by Sramek, Penney and Qu in this work was measured; compared and summarized. The differences of the measuring method, the schematic circuit diagram, the measurement results and area of application between impedance cardiograph and impedance spectroscopy were discussed and compared. The performance of this sensor-system was evaluated.
13

Tělesné složení u pacientů s diagnózou systémové sklerodermie / Body composition in patitents with systemic sclerosis

Česák, Michal January 2016 (has links)
Title: Body composition of patients with systemic sclerosis Objectives: The aim of this study was to compare selected parameters of body composition in patients with systemic sclerosis (SSc) with a group of age- and sex-matched healthy individuals (CG). Another objective was to evaluate the effect of selected clinical parameters in patients with SSc on the detected variability of the parameters of body composition and on physical activity of patients. Methods: The research group N = 95, group SSc (n = 59), control group (n = 36). Anthropometry (body height [cm], weight [kg], BMI [kg/m2 ]), bioelectrical impedance analysis - BIA 2000 (body fat - BF [%], total body water - TBW [%], lean body mass - LBM [kg], body cell mass - BCM [kg], BCM of FFM [%], the ECM / BCM); DEXA - Lunar Series iDXA (bone mineral density - BMD [g/m3 ], lean body mass - LBM [kg] body fat - BF [%], visceral fat - VF [kg] questionnaire on physical activity Human Activity Profile. Statistics: T test/Mann-Whitney U test, Cohen's d/partial eta squared (η2 ). Results: The results are presented as mean ± SD: body height: SSc 166.5 ± 7.1 cm, CG 171.2 ± 8.3 cm; body weight: SSc 62.4 ± 10.7 kg, CG 77.3 ± 11.9 kg; BMI: SSc 22.4 ± 4.3 kg/m2 , CG 26.4 ± 3.3 kg/m2 ; BF % BIA: SSc 24.6 % ± 7.8 %; CG 31.1 % ± 6.4 %; BF % DEXA: SSc 32.6 ± 8.2...
14

Multivariate non-invasive measurements of skin disorders

Nyström, Josefina January 2006 (has links)
<p>The present thesis proposes new methods for obtaining objective and accurate diagnoses in modern healthcare. Non-invasive techniques have been used to examine or diagnose three different medical conditions, namely neuropathy among diabetics, radiotherapy induced erythema (skin redness) among breast cancer patients and diagnoses of cutaneous malignant melanoma. The techniques used were Near-InfraRed spectroscopy (NIR), Multi Frequency Bio Impedance Analysis of whole body (MFBIA-body), Laser Doppler Imaging (LDI) and Digital Colour Photography (DCP).</p><p>The neuropathy for diabetics was studied in papers I and II. The first study was performed on diabetics and control subjects of both genders. A separation was seen between males and females and therefore the data had to be divided in order to obtain good models. NIR spectroscopy was shown to be a viable technique for measuring neuropathy once the division according to gender was made. The second study on diabetics, where MFBIA-body was added to the analysis, was performed on males exclusively. Principal component analysis showed that healthy reference subjects tend to separate from diabetics. Also, diabetics with severe neuropathy separate from persons less affected.</p><p>The preliminary study presented in paper III was performed on breast cancer patients in order to investigate if NIR, LDI and DCP were able to detect radiotherapy induced erythema. The promising results in the preliminary study motivated a new and larger study. This study, presented in papers IV and V, intended to investigate the measurement techniques further but also to examine the effect that two different skin lotions, Essex and Aloe vera have on the development of erythema. The Wilcoxon signed rank sum test showed that DCP and NIR could detect erythema, which is developed during one week of radiation treatment. LDI was able to detect erythema developed during two weeks of treatment. None of the techniques could detect any differences between the two lotions regarding the development of erythema.</p><p>The use of NIR to diagnose cutaneous malignant melanoma is presented as unpublished results in this thesis. This study gave promising but inconclusive results. NIR could be of interest for future development of instrumentation for diagnosis of skin cancer.</p>
15

Multivariate non-invasive measurements of skin disorders

Nyström, Josefina January 2006 (has links)
The present thesis proposes new methods for obtaining objective and accurate diagnoses in modern healthcare. Non-invasive techniques have been used to examine or diagnose three different medical conditions, namely neuropathy among diabetics, radiotherapy induced erythema (skin redness) among breast cancer patients and diagnoses of cutaneous malignant melanoma. The techniques used were Near-InfraRed spectroscopy (NIR), Multi Frequency Bio Impedance Analysis of whole body (MFBIA-body), Laser Doppler Imaging (LDI) and Digital Colour Photography (DCP). The neuropathy for diabetics was studied in papers I and II. The first study was performed on diabetics and control subjects of both genders. A separation was seen between males and females and therefore the data had to be divided in order to obtain good models. NIR spectroscopy was shown to be a viable technique for measuring neuropathy once the division according to gender was made. The second study on diabetics, where MFBIA-body was added to the analysis, was performed on males exclusively. Principal component analysis showed that healthy reference subjects tend to separate from diabetics. Also, diabetics with severe neuropathy separate from persons less affected. The preliminary study presented in paper III was performed on breast cancer patients in order to investigate if NIR, LDI and DCP were able to detect radiotherapy induced erythema. The promising results in the preliminary study motivated a new and larger study. This study, presented in papers IV and V, intended to investigate the measurement techniques further but also to examine the effect that two different skin lotions, Essex and Aloe vera have on the development of erythema. The Wilcoxon signed rank sum test showed that DCP and NIR could detect erythema, which is developed during one week of radiation treatment. LDI was able to detect erythema developed during two weeks of treatment. None of the techniques could detect any differences between the two lotions regarding the development of erythema. The use of NIR to diagnose cutaneous malignant melanoma is presented as unpublished results in this thesis. This study gave promising but inconclusive results. NIR could be of interest for future development of instrumentation for diagnosis of skin cancer.
16

Studies on Multifrequensy Multifunction Electrical Impedance Tomography (MfMf-EIT) to Improve Bio-Impedance Imaging

Bera, Tushar Kanti January 2013 (has links) (PDF)
Electrical Impedance Tomography (EIT) is a non linear inverse problem in which the electrical conductivity or resistivity distribution across a closed domain of interest is reconstructed from the surface potentials measured at the domain boundary by injecting a constant sinusoidal current through an array of surface electrodes. Being a non-invasive, non-radiating, non-ionizing, portable and inexpensive methodology, EIT has been extensively studied in medical diagnosis, biomedical engineering, biotechnology, chemical engineering, industrial and process engineering, civil and material engineering, soil and rock science, electronic industry, defense field, nano-technology and many other fields of applied physics. The reconstructed image quality in EIT depends mainly on the boundary data quality and the performance of the reconstruction algorithm used. The boundary data accuracy depends on the design of the practical phantoms, current injection method and boundary data measurement process and precision. On the other hand, the reconstruction algorithm performance is highly influenced by the mathematical modeling of the system, performance of the forward solver and Jacobian computation, inverse solver and the regularization techniques. Hence, for improving the EIT system performance, it is essential to improve the design of practical phantom, instrumentation and image reconstruction algorithm. As the electrical impedance of biological materials is a function of tissue composition and the frequency of applied ac signal, the better assessment of impedance distribution of biological tissues needs multifrequency EIT imaging. In medical EIT, to obtain a better image quality for a complex organ or a body part, accurate domain modelling with a large 3D finite element mesh is preferred and hence, the computation speed becomes very expensive and time consuming. But, the high speed reconstruction with improved image quality at low cost is always preferred in medical EIT. In this direction, a complete multifrequency multifunction EIT (MfMf-EIT) system is developed and multifrequency impedance reconstruction is studied to improve the bioimpedance imaging. The MfMf-EIT system consists of an MfMf-EIT instrumentation (MfMf-EITI), high speed impedance image reconstruction algorithms (IIRA), a Personal Computer (PC) and a number of practical phantoms with EIT sensors or electrodes. MfMf-EIT system and high speed IIRA are studied tested and evaluated with the practical phantoms and the multifrequency impedance imaging is improved with better image quality as well as fast image reconstruction. The MfMf-EIT system is also applied to the human subjects and the impedance imaging is studied for human body imaging and the system is evaluated. MfMf-EIT instrumentation (MfMf-EITI) consists of a multifrequency multifunction constant current injector (MfMf-CCI), multifrequency multifunction data acquisition system (MfMf DAS), a programmable electrode switching module (P-ESM) and a modified signal conditioner blocks (M-SCB) or data processing unit (DPU). MfMf-CCI, MfMf-DAS, P-ESM and M-SCBs are interfaced with a LabVIEW based data acquisition program (LV-DAP) controlled by a LabVIEW based graphical user interface (LV-GUI). LV-GUI controls the current injection and data acquisition with a user friendly, fast, reliable, efficient measurement process. The data acquisition system performance is improved by the high resolution NIDAQ card providing high precision measurement and high signal to noise ratio (SNR). MfMf-EIT system is developed as a versatile data acquisition system with a lot of flexibilities in EIT parameter selection that allows studying the image reconstruction more effectively. MfMf-EIT instrumentation controls the multifrequency and multifunctioned EIT experimentation with a number of system variables such as signal frequency, current amplitude, current signal wave forms and current injection patterns. It also works with either grounded load CCI or floating load CCI and collects the boundary data either in grounded potential form or differential form. The MfMf-EITI is futher modified to a battery based MfMf-EIT (BbMfMf-EIT) system to obtain a better patient safety and also to improve the SNR of the boundary data. MfMf-EIT system is having a facility of injecting voltage signal to the objects under test for conducting the applied potential tomography (APT). All the electronic circuit blocks in MfMf-EIT instrumentation are tested, evaluated and calibrated. The frequency response, load response, Fast Fourier Transform (FFT) studies and DSO analysis are conducted for studying the electronic performance and the signal quality of all the circuit blocks. They are all evaluated with both the transformer based power supply (TBPS) and battery based power supply (BBPS). MfMf-DAS, P-ESM and LV-DAP are tested and evaluated with digital data testing module (DDTM) and practical phantoms. A MatLAB-based Virtual Phantom for 2D EIT (MatVP2DEIT) is developed to generate accurate 2D boundary data for assessing the 2D EIT inverse solvers and its image reconstruction accuracy. It is a MATLAB-based computer program which defines a phantom domain and its inhomogeneities to generate the boundary potential data by changing its geometric parameters. In MatVP2DEIT, the phantom diameter, domain discretization, inhomogeneity number, inhomogeneity geometry (shape, size and position), electrode geometry, applied current magnitude, current injection pattern, background medium conductivity, inhomogeneity conductivity all are set as the phantom variables and are chosen indipendently for simulating different phantom configurations. A constant current injection is simulated at the phantom boundary with different current injection protocols and boundary potential data are calculated. A number of boundary data sets are generated with different phantom configurations and the resistivity images are reconstructed using EIDORS (Electrical Impedance Tomography and Diffuse Optical Tomography Reconstruction Software). Resistivity images are evaluated with the resistivity parameters and contrast parameters estimated from the elemental resistivity profiles of the reconstructed impedance images. MfMf-EIT system is studied, tested, evaluated with a number of practical phantoms eveloped with non-biological and biological materials and the multifrequency impedance imaging is improved. A number of saline phantoms with single and multiple inhomogeneities are developed and the boundary data profiles are studied and the phantom geometry is modified. NaCl-insulator phantoms and the NaCl-vegetable phantoms with different inhomogeneity configurations are developed and the multifrequency EIT reconstruction is studied with different current patterns, different current amplitudes and different frequencies using EIDORS as well as the developed IIRAs developed in MATLAB to evaluate the phantoms and MfMf-EIT system. Real tissue phantoms are developed with different chicken tissue backgrounds and high resistive inhomogeneities and the resistivity image reconstruction is studied using MfMf-EIT system. Chicken tissue phantoms are developed with chicken muscle tissue (CMTP) paste or chicken tissue blocks (CMTB) as the background mediums and chicken fat tissue, chicken bone, air hole and nylon cylinders are used as the inhomogeneity to obtained different phantom configurations. Resistivity imaging of all the real tissue phantoms is reconstructed in EIDORS and developed IIRAs with different current patterns, different frequencies and the images are evaluated by the image parameters to assess the phantoms as well as the MfMf-EIT system. Gold electrode phantoms are developed with thin film based flexible gold electrode arrays for improved bioimpedance and biomedical imaging. The thin film based gold electrode arrays of high geometric precision are developed on flexible FR4 sheet using electro-deposition process and used as the EIT sensors. The NaCl phantoms and real tissue phantoms are developed with gold electrode arrays and studied with MfMf-EIT system and and the resiulsts are compared with identical stainless steel electrode phantoms. NaCl phantoms are developed with 0.9% NaCl solution with single and multiple insulator or vegetable tissues as inhomogeneity. Gold electrode real tissue phantoms are also developed with chicken muscle tissues and fat tissues or other high resistive objects. The EIT images are reconstructed for the gold electrode NaCl phantoms and the gold electrode real tissue phantoms with different phantom geometries, different inhomogeneity configurations and different current patterns and the results are compared with identical SS electrode phantoms. High speed IIRAs called High Speed Model Based Iterative Image Reconstruction (HSMoBIIR) algorithms are developed in MATLAB for impedance image reconstruction in Electrical Impedance Tomography (EIT) by implementing high speed Jacobian calculation techniques using “Broyden’s Method (BM)” and “Adjoint Broyden’s Method (ABM)”. Gauss Newton method based EIT inverse solvers repeatitively evaluate the Jacobian (J) which consumes a lot of computation time for reconstruction, whereas, the HSMoBIIR with Broyden’s Methods (BM)-based accelerated Jacobian Matrix Calculators (JMCs) provides the high speed schemes for Jacobian (J) computation which is integrated with conjugate gradient scheme (CGS) for fast impedance reconstruction. The Broyden’s method based HSMoBIIR (BM-HSMoBIIR) and Adjoint Broyden’s method based HSMoBIIR (ABM-HSMoBIIR) algorithm are developed for high speed improved impedance imaging using BM based JMC (BM-JMC) and ABM-based JMC (ABM-JMC) respectively. Broyden’s Method based HSMoBIIR algorithms make explicit use of secant and adjoint information that can be obtained from the forward solution of the EIT governing equation and hence both the BM-HSMoBIIR and ABM-HSMoBIIR algorithms reduce the computational time remarkably by approximating the system Jacobian (J) successively through low-rank updates. The impedance image reconstruction is studied with BM-HSMoBIIR and ABM-HSMoBIIR algorithms using the simulated and practical phantom data and results are compared with a Gauss-Newton method based MoBIIR (GNMoBIIR) algorithm. The GNMoBIIR algorithm is developed with a Finite Element Method (FEM) based flexible forward solver (FFS) and Gauss-Newton method based inverse solver (GNIS) working with a modified Newton-Raphson iterative technique (NRIT). FFS solves the forward problem (FP) to obtain the computer estimated boundary potential data (Vc) data and NRIT based GNIS solve the inverse problem (IP) and the conductivity update vector [Δσ] is calculated by conjugate gradient search by comparing Vc measured boundary potential data (Vm) and using the Jacobian (J) matrix computed by the adjoint method. The conductivity reconstruction is studied with GNMoBIIR, BM-HSMoBIIR and ABM-HSMoBIIR algorithms using simulated data a practical phantom data and the results are compared. The reconstruction time, projection error norm (EV) and the solution error norm (Eσ) produced in HSMoBIIR algorithms are calculated and compared with GNMoBIIR algorithm. Results show that both the BM-HSMoBIIR and ABM-HSMoBIIR algorithms successfully reconstructs the conductivity distribution of the domain under test with its proper inhomogeneity and background conductivities for simulation as well as experimental studies. Simulated and practical phantom studies demonstrate that both the BM-HSMoBIIR and ABM-HSMoBIIR algorithms accelerate the impedance reconstruction by more than five times. It is also observed that EV and Eσ are reduced in both the HSMoBIIR algorithms and hence the image quality is improved. Noise analysis and convergence studies show that both the BM-HSMoBIIR and ABM-HSMoBIIR algorithms works faster and better in noisy conditions compared to GNMoBIIR. In low noise conditions, BM-HSMoBIIR is faster than to ABM-HSMoBIIR algorithm. But, in higher noisy environment, the ABM-HSMoBIIR is found faster and better than BM-HSMoBIIR. Two novel regularization methods called Projection Error Propagation-based Regularization (PEPR) and Block Matrix based Multiple Regularization (BMMR) are proposed to improve the image quality in Electrical Impedance Tomography (EIT). PEPR method defines the regularization parameter as a function of the projection error contributed by the mismatch (difference) between the data obtained from the experimental measurements (Vm) and calculated data (Vc). The regularization parameter in the reconstruction algorithm gets modified automatically according to the noise level in measured data and ill-posedness of the Hessian matrix. The L-2 norm of the projection error is calculated using the voltage difference and it is used to find the regularization parameter in each iteration in the reconstruction algorithm. In BMMR method, the response matrix (JTJ) obtained from the Jacobian matrix (J) has been partitioned into several sub-block matrices and the highest eigenvalue of each sub-block matrices has been chosen as regularization parameter for the nodes contained by that sub-block. The BMMR method preserved the local physiological information through the multiple regularization process which is then integrated to the ill-posed inverse problem to make the regularization more effective and optimum for all over the domain. Impedance imaging with simulated data and the practical phantom data is studied with PEPR and BMMR techniques in GNMoBIIR and EIDORS and the reconstructed images are compared with the single step regularization (STR) and Modified Levenberg Regularization (LMR). The projection error and the solution error norms are estimated in the reconstructions processes with PEPR and the BMMR methods and the results are compared with the errors estimated in STR and modified LMR techniques. Reconstructed images obtained with PEPR and BMMR are also studied with image parameters and contrast parameters and the reconstruction performance with PEPR and BMMR are evaluated by comparing the results with STR and modified LMR. PEPR and BMMR techniques are successfully implemented in the GNMoBIIR and EIDORS algorithms to improve the impedance image reconstruction by regularizing the solution domain in EIT reconstruction process. As the multifrequency EIT is always preferred in biological object imaging for better assessments of the frequency dependent bioimpedance response, multifrequency impedance imaging is studied with MfMf-EIT system developed for biomedical applications. MfMf-EIT system is studied, tested and evaluated with practical phantoms suitably developed for multifrequency impedance imaging within a wide range of frequency. Different biological materials are studied with electrical impedance spectroscopy (EIS) and a number of practical biological phantoms suitable for multifrequency EIT imaging are developed. The MfMf-EIT system is studied, tested and evaluated at different frequency levels with different current patterns using a number of NaCl phantoms with single, multiple and hybrid vegetable tissue phantoms as well as with chicken tissue phantoms. BbMfMf-EIT system is also studied and evaluated with the multifrequency EIT imaging using the developed biological phantoms. The developed MfMf-EIT system is applied on human body for impedance imaging of human anatomy. Impedance imaging of human leg and thigh is studied to visualize the muscle and bone tissues using different current patterns and different relative electrode positions. Ag/AgCl electrodes are attached to the leg and thigh using ECG gel and the boundary data are collected with MfMf-EIT EIT system by injecting a 1 mA and 50 kHz sinusoidal constant current with neighbouring and opposite current injection patterns. Impedance images of the femur bone of the human thigh and the tibia and fibula bones of the human leg along with the muscle tissue backgrounds are reconstructed in EIDORS and GNMoBIIR algorithms. Reconstructed resistivity profiles of bone and muscles are compared with the resistivity data profiles reported in the published literature. Impedance imaging of leg and thigh is studied with MfMf-EIT system for different current patterns, relative electrode positions and the images are evaluated to assess the system reliability. Battery based MfMf-EIT system (BbMfMf-EIT) is also studied for human leg and thigh imaging and it is observed that MfMf-EIT system and BbMfMf-EIT system are suitable for impedance imaging of human body imaging though the BbMfMf-EIT system increases the patiet safety. Therefore, the developed MfMf-EIT and BbMfMf-EIT systems are found quite suitable to improve the bio-impedance imaging in medical, biomedical and clinical applications as well as to study the anatomical and physiological status of the human body to diagnose, detect and monitor the tumors, lesions and a number of diseases or anatomical abnormalities in human subjects.
17

In-Vitro Biological Tissue State Monitoring based on Impedance Spectroscopy / Untersuchung der Stromanregung zur Überwachung der menschlichen Gesundheit und des biologischen Gewebes

Guermazi, Mahdi 04 May 2017 (has links) (PDF)
The relationship between post-mortem state and changes of biological tissue impedance has been investigated to serve as a basis for developing an in-vitro measurement method for monitoring the freshness of meat. The main challenges thereby are the reproducible measurement of the impedance of biological tissues and the classification method of their type and state. In order to realize reproducible tissue bio-impedance measurements, a suitable sensor taking into account the anisotropy of the biological tissue has been developed. It consists of cylindrical penetrating multi electrodes realizing good contacts between electrodes and the tissue. Experimental measurements have been carried out with different tissues and for a long period of time in order to monitor the state degradation with time. Measured results have been evaluated by means of the modified Fricke-Cole-Cole model. Results are reproducible and correspond to the expected behavior due to aging. An appropriate method for feature extraction and classification has been proposed using model parameters as features as input for classification using neural networks and fuzzy logic. A Multilayer Perceptron neural network (MLP) has been proposed for muscle type computing and the age computing and respectively freshness state of the meat. The designed neural network is able to generalize and to correctly classify new testing data with a high performance index of recognition. It reaches successful results of test equal to 100% for 972 created inputs for each muscle. An investigation of the influence of noise on the classification algorithm shows, that the MLP neural network has the ability to correctly classify the noisy testing inputs especially when the parameter noise is less than 0.6%. The success of classification is 100% for the muscles Longissimus Dorsi (LD) of beef, Semi-Membraneous (SM) of beef and Longissimus Dorsi (LD) of veal and 92.3% for the muscle Rectus Abdominis (RA) of veal. Fuzzy logic provides a successful alternative for easy classification. Using the Gaussian membership functions for the muscle type detection and trapezoidal member function for the classifiers related to the freshness detection, fuzzy logic realized an easy method of classification and generalizes correctly the inputs to the corresponding classes with a high level of recognition equal to 100% for meat type detection and with high accuracy for freshness computing equal to 84.62% for the muscle LD beef, 92.31 % for the muscle RA beef, 100 % for the muscle SM veal and 61.54% for the muscle LD veal. / Auf der Basis von Impedanzspektroskopie wurde ein neuartiges in-vitro-Messverfahren zur Überwachung der Frische von biologischem Gewebe entwickelt. Die wichtigsten Herausforderungen stellen dabei die Reproduzierbarkeit der Impedanzmessung und die Klassifizierung der Gewebeart sowie dessen Zustands dar. Für die Reproduzierbarkeit von Impedanzmessungen an biologischen Geweben, wurde ein zylindrischer Multielektrodensensor realisiert, der die 2D-Anisotropie des Gewebes berücksichtigt und einen guten Kontakt zum Gewebe realisiert. Experimentelle Untersuchungen wurden an verschiedenen Geweben über einen längeren Zeitraum durchgeführt und mittels eines modifizierten Fricke-Cole-Cole-Modells analysiert. Die Ergebnisse sind reproduzierbar und entsprechen dem physikalisch-basierten erwarteten Verhalten. Als Merkmale für die Klassifikation wurden die Modellparameter genutzt.
18

In-Vitro Biological Tissue State Monitoring based on Impedance Spectroscopy

Guermazi, Mahdi 04 May 2017 (has links)
The relationship between post-mortem state and changes of biological tissue impedance has been investigated to serve as a basis for developing an in-vitro measurement method for monitoring the freshness of meat. The main challenges thereby are the reproducible measurement of the impedance of biological tissues and the classification method of their type and state. In order to realize reproducible tissue bio-impedance measurements, a suitable sensor taking into account the anisotropy of the biological tissue has been developed. It consists of cylindrical penetrating multi electrodes realizing good contacts between electrodes and the tissue. Experimental measurements have been carried out with different tissues and for a long period of time in order to monitor the state degradation with time. Measured results have been evaluated by means of the modified Fricke-Cole-Cole model. Results are reproducible and correspond to the expected behavior due to aging. An appropriate method for feature extraction and classification has been proposed using model parameters as features as input for classification using neural networks and fuzzy logic. A Multilayer Perceptron neural network (MLP) has been proposed for muscle type computing and the age computing and respectively freshness state of the meat. The designed neural network is able to generalize and to correctly classify new testing data with a high performance index of recognition. It reaches successful results of test equal to 100% for 972 created inputs for each muscle. An investigation of the influence of noise on the classification algorithm shows, that the MLP neural network has the ability to correctly classify the noisy testing inputs especially when the parameter noise is less than 0.6%. The success of classification is 100% for the muscles Longissimus Dorsi (LD) of beef, Semi-Membraneous (SM) of beef and Longissimus Dorsi (LD) of veal and 92.3% for the muscle Rectus Abdominis (RA) of veal. Fuzzy logic provides a successful alternative for easy classification. Using the Gaussian membership functions for the muscle type detection and trapezoidal member function for the classifiers related to the freshness detection, fuzzy logic realized an easy method of classification and generalizes correctly the inputs to the corresponding classes with a high level of recognition equal to 100% for meat type detection and with high accuracy for freshness computing equal to 84.62% for the muscle LD beef, 92.31 % for the muscle RA beef, 100 % for the muscle SM veal and 61.54% for the muscle LD veal. / Auf der Basis von Impedanzspektroskopie wurde ein neuartiges in-vitro-Messverfahren zur Überwachung der Frische von biologischem Gewebe entwickelt. Die wichtigsten Herausforderungen stellen dabei die Reproduzierbarkeit der Impedanzmessung und die Klassifizierung der Gewebeart sowie dessen Zustands dar. Für die Reproduzierbarkeit von Impedanzmessungen an biologischen Geweben, wurde ein zylindrischer Multielektrodensensor realisiert, der die 2D-Anisotropie des Gewebes berücksichtigt und einen guten Kontakt zum Gewebe realisiert. Experimentelle Untersuchungen wurden an verschiedenen Geweben über einen längeren Zeitraum durchgeführt und mittels eines modifizierten Fricke-Cole-Cole-Modells analysiert. Die Ergebnisse sind reproduzierbar und entsprechen dem physikalisch-basierten erwarteten Verhalten. Als Merkmale für die Klassifikation wurden die Modellparameter genutzt.