• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Validação da impedância bioelétrica para determinação da composição corporal em mulheres no período pós parto / Validation of bioelectrical impedance for assessing body composition in postpartum women

Carla Valença Barros 05 July 2011 (has links)
O período pós-parto pode ser considerado a fase em que a mulher está exposta a retenção de massa corporal (MC) e desenvolvimento da obesidade. Na maioria das situações valorizam-se mais a perda de MC e pouco se conhece a respeito dos componentes que estão sendo mobilizados. Desta forma, há interesse de se validar técnicas acessíveis, como a impedância bioelétrica (BIA), que possam ser aplicadas no acompanhamento nutricional destas mulheres. O presente estudo teve como objetivo validar diferentes modelos de impedância bioelétrica (BIA) para a determinação da composição corporal em mulheres pós-parto tendo como ?padrão ouro? a técnica de absorciometria de dupla energia de raio X(DXA). A amostra foi composta por 46 mulheres no período pós-parto com idade acima de 18anos, inicialmente recrutadas e convidadas a participar da pesquisa, logo após o parto, para posteriormente serem avaliadas. A composição corporal (CC) foi mensurada através de três aparelhos distintos de BIA: RJL , BIO e Tanita e pela DXA. Os componentes101450BC 533corporais medidos foram: massa livre de gordura (MLG), massa gorda (MG) e percentual degordura corporal (%GC). Na análise estatística foram calculadas as médias e desvio-padrãodas variáveis contínuas. A concordância entre os componentes corporais determinados pelaDXA e cada BIA foi avaliada pelo método de Bland & Altman e pelo coeficiente decorrelação de concordância (CCC). Para comparação de médias das variáveis obtidas por BIAe DXA para cada faixa de índice de massa corporal (IMC), foi aplicada a ANOVA e oadotado o teste post-hoc de Tukey. O nível de significância adotado foi de 95% (p=0,05). Amédia ( desvio padrão) de idade foi de 25,5 4,6 anos, a MC de 73,6 12,2kg, o IMC de28,7 4,3kg/m, a MG de 29,87,4kg, a MLG de 43,25,7kg e o %GC de 41,84,3%,obtidos pelo DXA. Ao comparar-se os resultados dos diferentes equipamentos com o método padrão-ouro, verificou-se que houve diferença significativa entre a DXA e as BIA para todos componentes corporais, com exceção da MG fornecida pelo RJL (27,1Kg) e TAN (27,1Kg)em relação à DXA (29,8Kg). Os resultados mostraram haver uma boa reprodutibilidade emrelação aos aparelhos de BIA TAN (r=0,74; r=0,90) e RJL (r=0,78; r=0,89) para MLG e MG.Verificou-se que os equipamentos de BIA TAN e RJL forneceram estimativas semelhantes em relação à MLG, MG e %GC. Em relação aos valores da DXA o equipamento que mais se aproximou foi a TAN e o RJL quando avaliada a MG considerando todas as mulheres, mas quando estratificadas segundo o IMC, a análise foi mais acurada em mulheres obesas.Entretanto, a concordância não foi satisfatória entre os componentes corporais fornecidos pelas BIA em relação à DXA. As BIAs avaliadas no presente estudo subestimaram o %GC e superestimaram a MLG para esse grupo de mulheres no período pós-parto. Conclui-se que as BIA avaliadas não são recomendadas para avaliação da CC neste grupo de mulheres no período pós-parto. / Postpartum women are at risk of body weight retention and consequently becoming obese. Usually, during postpartum period there is a greater concern in weight loss instead of measuring which body compartment is being mobilized. Thus, there is a growing interesting to validate field and affordable techniques, such as the bioelectrical impedance (BIA) to determine body composition in this segment of the population. The purpose of this study was to validate different BIA devices using dual-energy x-ray absorptiomety (DXA) as a goldstandard in postpartum women. Forty-six postpartum women aged 18 years and over were enrolled in the study. They were recruited soon after delivery from two health units (Hospital São José of Mesquita District and Policlínica Piquet Carneiro, located in Rio de Janeiro city).All measurements were performed at the Laboratório Interdisciplinar de Avaliação Nutricional da Universidade do Estado do Rio de Janeiro. Participants were instructed to follow a standardized protocol for body composition measurements. Anthropometric variables(body mass - BM, stature, waist and hip circumferences) were collected. Body composition was determined by DXA and also obtained using the following BIA devices :model RJL 101(RJL Systems, Inc. Clinton, USA), model BIOD 450 (Biodynamics Corporation, USA)and I model BC 533 (Tanita, USA). Descriptive statistical analysis was done for continuous variables. ANOVA was used to verify differences between mean values of fat free mass(FFM), fat mass (FM) and percentage body fat (%BF) within BIA devices and DXA. Concordance analysis between each body component obtained by DXA and all BIA devices were performed using Bland & Altman plots and the Concordance Correlation Coefficient(CCC). ANOVA was used to compare mean values within BIA and DXA, and Tukey post-hoc was adopted. SPSS and MedCalc software were used in the analysis. Mean values (standard deviation) of age, BM, body mass index, FM by DXA, FFM by DXA, %BF by DXA were 25.5 4.6 years, 73.6 12.2kg, 28.7 4.3kg/m, 29.87.4kg, 43.2 5.7kg, 41.8 4.3%,respectively. When comparing the results within different equipments (DXA, RJL, BIOD and TAN), it was verified that there was significant difference between DXA and BIA equipments for all body components, except for MG from RJL (27.1Kg) and TAN (27.1Kg) in relation toD XA (29.8Kg). The results showed good reproducibility in relation to BIA TAN (FFM, r=0.74; FM, r=0.90) and RJL (FFM, r=0.78; FM, r=0.89). It was verified that BIA TAN and RJL yielded similar estimates for FFM, FM and % BF. When all women were considered together no significant difference was observed for FM obtained by TAN, RJL and DXA. When considering BMI categories the estimates were better for obese women. However, the agreement was not satisfactory for body components supplied by BIA in relation to DXA. All BIA devices tended to underestimated % BF and overestimated FFM for this sample.
2

Validação da impedância bioelétrica para determinação da composição corporal em mulheres no período pós parto / Validation of bioelectrical impedance for assessing body composition in postpartum women

Carla Valença Barros 05 July 2011 (has links)
O período pós-parto pode ser considerado a fase em que a mulher está exposta a retenção de massa corporal (MC) e desenvolvimento da obesidade. Na maioria das situações valorizam-se mais a perda de MC e pouco se conhece a respeito dos componentes que estão sendo mobilizados. Desta forma, há interesse de se validar técnicas acessíveis, como a impedância bioelétrica (BIA), que possam ser aplicadas no acompanhamento nutricional destas mulheres. O presente estudo teve como objetivo validar diferentes modelos de impedância bioelétrica (BIA) para a determinação da composição corporal em mulheres pós-parto tendo como ?padrão ouro? a técnica de absorciometria de dupla energia de raio X(DXA). A amostra foi composta por 46 mulheres no período pós-parto com idade acima de 18anos, inicialmente recrutadas e convidadas a participar da pesquisa, logo após o parto, para posteriormente serem avaliadas. A composição corporal (CC) foi mensurada através de três aparelhos distintos de BIA: RJL , BIO e Tanita e pela DXA. Os componentes101450BC 533corporais medidos foram: massa livre de gordura (MLG), massa gorda (MG) e percentual degordura corporal (%GC). Na análise estatística foram calculadas as médias e desvio-padrãodas variáveis contínuas. A concordância entre os componentes corporais determinados pelaDXA e cada BIA foi avaliada pelo método de Bland & Altman e pelo coeficiente decorrelação de concordância (CCC). Para comparação de médias das variáveis obtidas por BIAe DXA para cada faixa de índice de massa corporal (IMC), foi aplicada a ANOVA e oadotado o teste post-hoc de Tukey. O nível de significância adotado foi de 95% (p=0,05). Amédia ( desvio padrão) de idade foi de 25,5 4,6 anos, a MC de 73,6 12,2kg, o IMC de28,7 4,3kg/m, a MG de 29,87,4kg, a MLG de 43,25,7kg e o %GC de 41,84,3%,obtidos pelo DXA. Ao comparar-se os resultados dos diferentes equipamentos com o método padrão-ouro, verificou-se que houve diferença significativa entre a DXA e as BIA para todos componentes corporais, com exceção da MG fornecida pelo RJL (27,1Kg) e TAN (27,1Kg)em relação à DXA (29,8Kg). Os resultados mostraram haver uma boa reprodutibilidade emrelação aos aparelhos de BIA TAN (r=0,74; r=0,90) e RJL (r=0,78; r=0,89) para MLG e MG.Verificou-se que os equipamentos de BIA TAN e RJL forneceram estimativas semelhantes em relação à MLG, MG e %GC. Em relação aos valores da DXA o equipamento que mais se aproximou foi a TAN e o RJL quando avaliada a MG considerando todas as mulheres, mas quando estratificadas segundo o IMC, a análise foi mais acurada em mulheres obesas.Entretanto, a concordância não foi satisfatória entre os componentes corporais fornecidos pelas BIA em relação à DXA. As BIAs avaliadas no presente estudo subestimaram o %GC e superestimaram a MLG para esse grupo de mulheres no período pós-parto. Conclui-se que as BIA avaliadas não são recomendadas para avaliação da CC neste grupo de mulheres no período pós-parto. / Postpartum women are at risk of body weight retention and consequently becoming obese. Usually, during postpartum period there is a greater concern in weight loss instead of measuring which body compartment is being mobilized. Thus, there is a growing interesting to validate field and affordable techniques, such as the bioelectrical impedance (BIA) to determine body composition in this segment of the population. The purpose of this study was to validate different BIA devices using dual-energy x-ray absorptiomety (DXA) as a goldstandard in postpartum women. Forty-six postpartum women aged 18 years and over were enrolled in the study. They were recruited soon after delivery from two health units (Hospital São José of Mesquita District and Policlínica Piquet Carneiro, located in Rio de Janeiro city).All measurements were performed at the Laboratório Interdisciplinar de Avaliação Nutricional da Universidade do Estado do Rio de Janeiro. Participants were instructed to follow a standardized protocol for body composition measurements. Anthropometric variables(body mass - BM, stature, waist and hip circumferences) were collected. Body composition was determined by DXA and also obtained using the following BIA devices :model RJL 101(RJL Systems, Inc. Clinton, USA), model BIOD 450 (Biodynamics Corporation, USA)and I model BC 533 (Tanita, USA). Descriptive statistical analysis was done for continuous variables. ANOVA was used to verify differences between mean values of fat free mass(FFM), fat mass (FM) and percentage body fat (%BF) within BIA devices and DXA. Concordance analysis between each body component obtained by DXA and all BIA devices were performed using Bland & Altman plots and the Concordance Correlation Coefficient(CCC). ANOVA was used to compare mean values within BIA and DXA, and Tukey post-hoc was adopted. SPSS and MedCalc software were used in the analysis. Mean values (standard deviation) of age, BM, body mass index, FM by DXA, FFM by DXA, %BF by DXA were 25.5 4.6 years, 73.6 12.2kg, 28.7 4.3kg/m, 29.87.4kg, 43.2 5.7kg, 41.8 4.3%,respectively. When comparing the results within different equipments (DXA, RJL, BIOD and TAN), it was verified that there was significant difference between DXA and BIA equipments for all body components, except for MG from RJL (27.1Kg) and TAN (27.1Kg) in relation toD XA (29.8Kg). The results showed good reproducibility in relation to BIA TAN (FFM, r=0.74; FM, r=0.90) and RJL (FFM, r=0.78; FM, r=0.89). It was verified that BIA TAN and RJL yielded similar estimates for FFM, FM and % BF. When all women were considered together no significant difference was observed for FM obtained by TAN, RJL and DXA. When considering BMI categories the estimates were better for obese women. However, the agreement was not satisfactory for body components supplied by BIA in relation to DXA. All BIA devices tended to underestimated % BF and overestimated FFM for this sample.
3

Avaliação da técnica de impedância bioelétrica na identificação das alterações da composição corporal em mulheres no período pós-parto / Assessment of body composition changes in women in the postpartum period by bioelectrical impedance

Ana Cristina Teixeira Santos 20 December 2013 (has links)
Este trabalho teve como objetivo verificar se a técnica de impedância bioelétrica (IB) identifica as modificações da composição corporal em mulheres no período pós-parto. Participaram do estudo 47 mulheres (≥ 18 anos), nas quais foram avaliadas massa livre de gordura (MLG), massa gorda (MG) e percentual de gordura corporal (%GC) pelos equipamentos IB_Tanita BC 533; IB_RJL 101 e por absorciometria de raio X de dupla energia (DXA). Todas as avaliações foram feitas no mesmo dia. Posteriormente, as mulheres foram categorizadas em dois grupos: com perda ponderal (n= 24) e com ganho ponderal (n= 22). Os valores médios das alterações da composição corporal (CC), foram comparados intra-métodos e em relação ao método padrão-ouro (DXA) através de teste T-pareado. A concordância entre as diferenças das alterações da CC obtidas pelas IB e DXA foi avaliada pelo método de Bland & Altman e pelo coeficiente de correlação intraclasse (CCI). A média  desvio padrão de idade foi de 26,7  5,2 anos e o tempo médio da captação no pós-parto para a primeira avaliação foi de 2,6  2,0 meses e 8,0  2,7 meses para a segunda avaliação. A média de massa corporal (MC) foi de 74,6  11,4 kg na primeira avaliação e 75,1  12,6 kg na segunda avaliação, correspondendo a um valor de índice de massa corporal (IMC) de 28,8  4,0 kg/m2 e 29,0  4,6 kg/m2, respectivamente. O %GC medido pela DXA foi de 40,1  4,9 % para a primeira avaliação e de 41,0  5,2 %, para a segunda avaliação, representando uma MG de 30,2  6,6 kg e de 30,9  8,0 kg, respectivamente. Ambas as IB subestimaram a alteração do % GC (-0,7 % para IB_Tanita e -1,1% para IB_RJL) e MG (-0,6 kg para IB_Tanita e -1,0 kg IB_RJL) em relação ao DXA. Por sua vez, as alterações de MLG foram superestimadas 0,8 kg pela IB_Tanita e 1,0 kg IB_RJL. Houve boa concordância (CCI ≥ 0,75) entre as alterações identificadas para MG pela IB_Tanita e por DXA e satisfatória pela IB_RJL. Dessa forma o presente estudo verificou um desempenho satisfatório da técnica de IB em identificar as alterações da MG gorda e que a IB_Tanita mostrou-se melhor que a IB_RJL na estimativa da alteração desse componente corporal nesse grupo de mulheres pós-parto. / The aim of the present study is to assure that the measurement of the bioelectrical impedance (IB) identifies the changes in the body composition of postpartum women. Forty-seven women (≥ 18 years of age) were enrolled in the study. Body composition (BC) - fat free mass (FFM), fat mass (FM) and percentage body fat (%BF) - was obtained by two IB devices (Tanita BC 533 and RJL 101) and DXA. All measurements were performed at the same day in two different postpartum moments. The women were categorized in two groups: with weight loss (WWL, n= 24) and with weight gain (WWG, n= 22). Pair T-test was used to compare mean difference values within methods and DXA. Bland & Altman plots and intraclass correlation coefficients (ICC) were used to evaluate the agreement between body composition changes obtained by both IB and DXA. The first and second visits for BC measurements occurred 2,6  2,0 months e 8,0  2,7 months after delivery, respectively. Mean ( SD) age was 26.7  5.2 years and body mass was 74.6  11.4 kg at the first visit and 75.1  12.6 kg at the second visit. Women were overweight in both visits (BMI= 28.8  4,0kg/m2 e 29.0  4.6 kg/m2). % BF measured by DXA at the first visit was 40.1  4.9% and at the second visit was 41.0  5.2% yielding on average a FM of 30.2  6,6 kg and 30,9  8,0 kg, respectively.. IB_Tantia yelded lower mean values for FFM and FM compare to DXA mean values, except for %BF. Both IB underestimated %BF (-0.7% for Tanita and -1.1% for RJL) and FM changes (-0.6 kg for Tanita and -1.0 for RJL) compared to DXA changes. On the other hand FFM changes were overestimated by Tanita (0,8 kg) and RJL (1,0 kg). There was a good agreement (CCI ≥ 0.75) between FM changes measured by IB_Tanita and DXA and a fair agreement for IB_RJL. Therefore the IB technique was able to identified FM changes, and IB_Tanita showed a better performance than IB_RJL on the estimation of FM changes in these postpartum women.
4

Avaliação da técnica de impedância bioelétrica na identificação das alterações da composição corporal em mulheres no período pós-parto / Assessment of body composition changes in women in the postpartum period by bioelectrical impedance

Ana Cristina Teixeira Santos 20 December 2013 (has links)
Este trabalho teve como objetivo verificar se a técnica de impedância bioelétrica (IB) identifica as modificações da composição corporal em mulheres no período pós-parto. Participaram do estudo 47 mulheres (≥ 18 anos), nas quais foram avaliadas massa livre de gordura (MLG), massa gorda (MG) e percentual de gordura corporal (%GC) pelos equipamentos IB_Tanita BC 533; IB_RJL 101 e por absorciometria de raio X de dupla energia (DXA). Todas as avaliações foram feitas no mesmo dia. Posteriormente, as mulheres foram categorizadas em dois grupos: com perda ponderal (n= 24) e com ganho ponderal (n= 22). Os valores médios das alterações da composição corporal (CC), foram comparados intra-métodos e em relação ao método padrão-ouro (DXA) através de teste T-pareado. A concordância entre as diferenças das alterações da CC obtidas pelas IB e DXA foi avaliada pelo método de Bland & Altman e pelo coeficiente de correlação intraclasse (CCI). A média  desvio padrão de idade foi de 26,7  5,2 anos e o tempo médio da captação no pós-parto para a primeira avaliação foi de 2,6  2,0 meses e 8,0  2,7 meses para a segunda avaliação. A média de massa corporal (MC) foi de 74,6  11,4 kg na primeira avaliação e 75,1  12,6 kg na segunda avaliação, correspondendo a um valor de índice de massa corporal (IMC) de 28,8  4,0 kg/m2 e 29,0  4,6 kg/m2, respectivamente. O %GC medido pela DXA foi de 40,1  4,9 % para a primeira avaliação e de 41,0  5,2 %, para a segunda avaliação, representando uma MG de 30,2  6,6 kg e de 30,9  8,0 kg, respectivamente. Ambas as IB subestimaram a alteração do % GC (-0,7 % para IB_Tanita e -1,1% para IB_RJL) e MG (-0,6 kg para IB_Tanita e -1,0 kg IB_RJL) em relação ao DXA. Por sua vez, as alterações de MLG foram superestimadas 0,8 kg pela IB_Tanita e 1,0 kg IB_RJL. Houve boa concordância (CCI ≥ 0,75) entre as alterações identificadas para MG pela IB_Tanita e por DXA e satisfatória pela IB_RJL. Dessa forma o presente estudo verificou um desempenho satisfatório da técnica de IB em identificar as alterações da MG gorda e que a IB_Tanita mostrou-se melhor que a IB_RJL na estimativa da alteração desse componente corporal nesse grupo de mulheres pós-parto. / The aim of the present study is to assure that the measurement of the bioelectrical impedance (IB) identifies the changes in the body composition of postpartum women. Forty-seven women (≥ 18 years of age) were enrolled in the study. Body composition (BC) - fat free mass (FFM), fat mass (FM) and percentage body fat (%BF) - was obtained by two IB devices (Tanita BC 533 and RJL 101) and DXA. All measurements were performed at the same day in two different postpartum moments. The women were categorized in two groups: with weight loss (WWL, n= 24) and with weight gain (WWG, n= 22). Pair T-test was used to compare mean difference values within methods and DXA. Bland & Altman plots and intraclass correlation coefficients (ICC) were used to evaluate the agreement between body composition changes obtained by both IB and DXA. The first and second visits for BC measurements occurred 2,6  2,0 months e 8,0  2,7 months after delivery, respectively. Mean ( SD) age was 26.7  5.2 years and body mass was 74.6  11.4 kg at the first visit and 75.1  12.6 kg at the second visit. Women were overweight in both visits (BMI= 28.8  4,0kg/m2 e 29.0  4.6 kg/m2). % BF measured by DXA at the first visit was 40.1  4.9% and at the second visit was 41.0  5.2% yielding on average a FM of 30.2  6,6 kg and 30,9  8,0 kg, respectively.. IB_Tantia yelded lower mean values for FFM and FM compare to DXA mean values, except for %BF. Both IB underestimated %BF (-0.7% for Tanita and -1.1% for RJL) and FM changes (-0.6 kg for Tanita and -1.0 for RJL) compared to DXA changes. On the other hand FFM changes were overestimated by Tanita (0,8 kg) and RJL (1,0 kg). There was a good agreement (CCI ≥ 0.75) between FM changes measured by IB_Tanita and DXA and a fair agreement for IB_RJL. Therefore the IB technique was able to identified FM changes, and IB_Tanita showed a better performance than IB_RJL on the estimation of FM changes in these postpartum women.

Page generated in 0.0617 seconds