1

Avaliação da bioimpedância em recém nascidos pré-termos com síndrome do desconforto respiratório

Calixto, Soraia Zacharias 10 2010 (has links)
The objective of this work is to offer a new method of evaluation using the corporal and thoracic bioimpedance of pre-term neonate with Respiratory Discomfort Syndrome, submitted or not to the invasive mechanical ventilation. Thirty pre-term neonates with Respiratory Discomfort Syndrome were evaluated. They were admitted interned in the newborn intensive therapy unit of Hospital Universitário Evangélico de Curitiba (HUEC) from August to November of 2004. The percentage average of the gestational age in both groups was 32 weeks and the weight was 1250g. The newborn were divided into two groups, group A (15 newborns), with Respiratory Discomfort Syndrome of medium to moderate clinical repercussion, needing the invasive ventilator support. Group B (15 newborn) with light level of Respiratory Discomfort, without the need of ventilator support. The newborn of both groups were evaluated according to the Silverman-Andersen report. Which average in group A was 7 and in group B was 3. Five time speed measurement of subjects of group A were analyzed in the statistical analyses, and they were compared to an unique observation of group B. On the first measurement made in group A, it was noticed a low resistance both corporal (410) and thoracic (32,53) relative to group B. where the percentage average was 595 in the corporal resistance and 46,13 in the thoracic one. In the capacitive reactance it was noticed in the first analyses an inversely proportional behavior, and an increasing in the capacitive reactance for both corporal and thoracic in group A related to group B. As long as the newborns in group A improved clinically, a tendency in increasing the resistance values both corporal and thoracic was observed, correlating with the ventilator support removal. The opposite occurred in the capacitive reactance, both corporal and thoracic. So, the evaluation through the corporal bioimpedance in this work got statistically significant results, and it can be used as a method of evaluation improving the clinical diagnosis of the patient. / O objetivo deste trabalho é propor um novo método de avaliação através da bioimpedância corporal e torácica em recém-nascidos pré-termo com Síndrome do Desconforto Respiratório, submetidos ou não á ventilação mecânica invasiva. Foram avaliados trinta neonatos pré-termos com Síndrome do Desconforto Respiratório, internados na unidade de Terapia Intensiva Neonatal (UTIN) do Hospital Universitário Evangélico de Curitiba (HUEC), no período de agosto à novembro de 2004. A média da idade gestacional de ambos os grupos foi de 32 semanas e o peso de 1250g. Os recém-nascidos (RN) foram divididos em dois grupos, grupo A (15 neonatos), Síndrome do Desconforto Respiratório de média a moderada repercussão clínica, necessitando de suporte ventilatório invasivo. Grupo B (15 neonatos) Grau leve de Desconforto Respiratório, sem necessidade de suporte ventilatório. Os neonatos dos dois grupos foram avaliados conforme o boletim de Silverman-Andersen, a média percentual no grupo A foi de 77 e no grupo B de 3. Na análise estatística foram analisados cinco momentos do grupo A e comparado esses momentos com uma única observação do grupo B. Nos primeira mensuração realizada no grupo A, observa-se uma resistência tanto corporal (410 Ω) e torácica (32,53 Ω), baixa em relação a obtida no grupo B, onde a média percentual foi de 596 Ω, na resistência corporal e na torácica de 46,13 Ω. Na reatância capacitiva observa-se na primeira análise um comportamento inversamente proporcional, ocorrendo um aumento na reatância capacitiva tanto corporal como torácica no grupo A em relação ao grupo B. A medida que o neonato do grupo A, melhora clinicamente observa-se uma tendência ao aumento de valores de resistência tanto corporal com a torácica, correlacionada com a retirada da prótese ventilatório. Ocorrendo o inverso com a reatância capacitiva tanto corporal como torácica. Portanto, a avaliação através da bioimpedância corporal neste trabalho obteve resultados estatisticamente significativos podendo ser utilizada como um método de avaliação, enriquecendo o diagnóstico clínico do paciente.
2

Avaliação do estado nutricional de crianças antes, durante e após o tratamento quimioterápico

Behling, Estela Beatriz [UNESP] 13 August 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:05Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-08-13Bitstream added on 2014-06-13T21:02:08Z : No. of bitstreams: 1 behling_eb_dr_arafcf.pdf: 524574 bytes, checksum: 4282566c71831604413ca31e88390247 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Universidade Estadual Paulista (UNESP) / As crianças com câncer necessitam manter o crescimento linear e o ganho de peso para uma melhor evolução clínica. Assim, o tratamento da criança com câncer deve garantir não só sua sobrevivência, mas proporcionar crescimento e desenvolvimento adequados. A avaliação nutricional é utilizada para reconhecer o paciente com maior facilidade de desenvolver a má nutrição garantindo assim um planejamento nutricional adequado. O objetivo do presente estudo foi avaliar o estado nutricional de crianças antes, durante e após o tratamento quimioterápico. Foram avaliadas 14 crianças com câncer, com idade entre 5 a 15 anos, divididas em dois grupos: Grupo Tumores Sólidos e Grupo Tumores Hematológicos. Estas foram avaliadas através dos dados de ingestão alimentar, antropometria, análise por Impedância Bioelétrica (BIA) e por Diluição Isotópica. Os resultados encontrados demonstram que os pacientes apresentaram um aumento de peso, estatura, índice de massa corporal, circunferência do quadril, da cintura e do braço, da prega cutânea subescapular, assim como o aumento da massa gorda pela técnica de diluição isotópica durante o tratamento quimioterápico, no Grupo Tumores Hematológicos. No Grupo Tumores Sólidos as crianças apresentaram uma diminuição da massa magra, quando analisado pela impedância bioelétrica. Houve uma correlação positiva entre a prega cutânea tricipital e a massa gorda obtida através da BIA e pela Diluição Isotópica. A circunferência muscular do braço também se correlacionou com a massa magra estimada pela BIA e pela Diluição Isotópica. Não houve mudança na ingestão energética e de macronutrientes nos três momentos da pesquisa. Esses resultados demonstram que os pacientes com tumores hematológicos apresentaram aumento de peso, estatura e de massa gorda, fato este não ocorrido no Grupo Tumores Sólidos. / Children with cancer need to maintain growth and weight gain to a better clinic evolution. So, the treatment of children with cancer must not only guarantee the survival but also adequate growth and development. The nutritional assessment is useful to recognize the patient who is more accessible to develop malnutrition leading to an adequate nutritional plan. The aim of this study was to assess the nutritional status in children before, during and after chemotherapy treatment. In this study, 14 children with cancer were evaluated ranging from 5-15 years old devided into two groups: Hematologic Tumor Group and Solid Tumor Group. They were evaluated through dietary intake, anthropometry, bioimpedance analysis (BIA) and isotopic dilution. The results show that the patients increase weight, stature, body mass index, hip, waist and arm circumferences, subscapular skinfold thickness, as well as an increase in fat-mass with isotopic dilution technique during the chemotherapy treatment, in the Hematologic Tumors Group. In the Solid Tumor Group the children showed a reduction in fat free mass when assessed by bioelectric impedance. There was a positive correlation between triceps skinfold thickness and fat-mass with BIA and Isotopic Dilution technique. The arm muscle circumference correlated with the fatfree- mass estimated by the BIA and Isotopic Dilution. There was no change in energetic intake and macronutrients at the three moments of the research. These results demonstrate that patients with hematologic tumors had an increase in body weight, stature and fat-mass, which was not observed in Solid Tumors Group. The good correlation between anthropometry and isotopic dilution technique and BIA show its applicability in clinical practice.
3

Validação da impedância bioelétrica para determinação da composição corporal em mulheres no período pós parto / Validation of bioelectrical impedance for assessing body composition in postpartum women

Carla Valença Barros 05 July 2011 (has links)
O período pós-parto pode ser considerado a fase em que a mulher está exposta a retenção de massa corporal (MC) e desenvolvimento da obesidade. Na maioria das situações valorizam-se mais a perda de MC e pouco se conhece a respeito dos componentes que estão sendo mobilizados. Desta forma, há interesse de se validar técnicas acessíveis, como a impedância bioelétrica (BIA), que possam ser aplicadas no acompanhamento nutricional destas mulheres. O presente estudo teve como objetivo validar diferentes modelos de impedância bioelétrica (BIA) para a determinação da composição corporal em mulheres pós-parto tendo como ?padrão ouro? a técnica de absorciometria de dupla energia de raio X(DXA). A amostra foi composta por 46 mulheres no período pós-parto com idade acima de 18anos, inicialmente recrutadas e convidadas a participar da pesquisa, logo após o parto, para posteriormente serem avaliadas. A composição corporal (CC) foi mensurada através de três aparelhos distintos de BIA: RJL , BIO e Tanita e pela DXA. Os componentes101450BC 533corporais medidos foram: massa livre de gordura (MLG), massa gorda (MG) e percentual degordura corporal (%GC). Na análise estatística foram calculadas as médias e desvio-padrãodas variáveis contínuas. A concordância entre os componentes corporais determinados pelaDXA e cada BIA foi avaliada pelo método de Bland & Altman e pelo coeficiente decorrelação de concordância (CCC). Para comparação de médias das variáveis obtidas por BIAe DXA para cada faixa de índice de massa corporal (IMC), foi aplicada a ANOVA e oadotado o teste post-hoc de Tukey. O nível de significância adotado foi de 95% (p=0,05). Amédia ( desvio padrão) de idade foi de 25,5 4,6 anos, a MC de 73,6 12,2kg, o IMC de28,7 4,3kg/m, a MG de 29,87,4kg, a MLG de 43,25,7kg e o %GC de 41,84,3%,obtidos pelo DXA. Ao comparar-se os resultados dos diferentes equipamentos com o método padrão-ouro, verificou-se que houve diferença significativa entre a DXA e as BIA para todos componentes corporais, com exceção da MG fornecida pelo RJL (27,1Kg) e TAN (27,1Kg)em relação à DXA (29,8Kg). Os resultados mostraram haver uma boa reprodutibilidade emrelação aos aparelhos de BIA TAN (r=0,74; r=0,90) e RJL (r=0,78; r=0,89) para MLG e MG.Verificou-se que os equipamentos de BIA TAN e RJL forneceram estimativas semelhantes em relação à MLG, MG e %GC. Em relação aos valores da DXA o equipamento que mais se aproximou foi a TAN e o RJL quando avaliada a MG considerando todas as mulheres, mas quando estratificadas segundo o IMC, a análise foi mais acurada em mulheres obesas.Entretanto, a concordância não foi satisfatória entre os componentes corporais fornecidos pelas BIA em relação à DXA. As BIAs avaliadas no presente estudo subestimaram o %GC e superestimaram a MLG para esse grupo de mulheres no período pós-parto. Conclui-se que as BIA avaliadas não são recomendadas para avaliação da CC neste grupo de mulheres no período pós-parto. / Postpartum women are at risk of body weight retention and consequently becoming obese. Usually, during postpartum period there is a greater concern in weight loss instead of measuring which body compartment is being mobilized. Thus, there is a growing interesting to validate field and affordable techniques, such as the bioelectrical impedance (BIA) to determine body composition in this segment of the population. The purpose of this study was to validate different BIA devices using dual-energy x-ray absorptiomety (DXA) as a goldstandard in postpartum women. Forty-six postpartum women aged 18 years and over were enrolled in the study. They were recruited soon after delivery from two health units (Hospital São José of Mesquita District and Policlínica Piquet Carneiro, located in Rio de Janeiro city).All measurements were performed at the Laboratório Interdisciplinar de Avaliação Nutricional da Universidade do Estado do Rio de Janeiro. Participants were instructed to follow a standardized protocol for body composition measurements. Anthropometric variables(body mass - BM, stature, waist and hip circumferences) were collected. Body composition was determined by DXA and also obtained using the following BIA devices :model RJL 101(RJL Systems, Inc. Clinton, USA), model BIOD 450 (Biodynamics Corporation, USA)and I model BC 533 (Tanita, USA). Descriptive statistical analysis was done for continuous variables. ANOVA was used to verify differences between mean values of fat free mass(FFM), fat mass (FM) and percentage body fat (%BF) within BIA devices and DXA. Concordance analysis between each body component obtained by DXA and all BIA devices were performed using Bland & Altman plots and the Concordance Correlation Coefficient(CCC). ANOVA was used to compare mean values within BIA and DXA, and Tukey post-hoc was adopted. SPSS and MedCalc software were used in the analysis. Mean values (standard deviation) of age, BM, body mass index, FM by DXA, FFM by DXA, %BF by DXA were 25.5 4.6 years, 73.6 12.2kg, 28.7 4.3kg/m, 29.87.4kg, 43.2 5.7kg, 41.8 4.3%,respectively. When comparing the results within different equipments (DXA, RJL, BIOD and TAN), it was verified that there was significant difference between DXA and BIA equipments for all body components, except for MG from RJL (27.1Kg) and TAN (27.1Kg) in relation toD XA (29.8Kg). The results showed good reproducibility in relation to BIA TAN (FFM, r=0.74; FM, r=0.90) and RJL (FFM, r=0.78; FM, r=0.89). It was verified that BIA TAN and RJL yielded similar estimates for FFM, FM and % BF. When all women were considered together no significant difference was observed for FM obtained by TAN, RJL and DXA. When considering BMI categories the estimates were better for obese women. However, the agreement was not satisfactory for body components supplied by BIA in relation to DXA. All BIA devices tended to underestimated % BF and overestimated FFM for this sample.
4

Validação da impedância bioelétrica para determinação da composição corporal em mulheres no período pós parto / Validation of bioelectrical impedance for assessing body composition in postpartum women

Carla Valença Barros 05 July 2011 (has links)
O período pós-parto pode ser considerado a fase em que a mulher está exposta a retenção de massa corporal (MC) e desenvolvimento da obesidade. Na maioria das situações valorizam-se mais a perda de MC e pouco se conhece a respeito dos componentes que estão sendo mobilizados. Desta forma, há interesse de se validar técnicas acessíveis, como a impedância bioelétrica (BIA), que possam ser aplicadas no acompanhamento nutricional destas mulheres. O presente estudo teve como objetivo validar diferentes modelos de impedância bioelétrica (BIA) para a determinação da composição corporal em mulheres pós-parto tendo como ?padrão ouro? a técnica de absorciometria de dupla energia de raio X(DXA). A amostra foi composta por 46 mulheres no período pós-parto com idade acima de 18anos, inicialmente recrutadas e convidadas a participar da pesquisa, logo após o parto, para posteriormente serem avaliadas. A composição corporal (CC) foi mensurada através de três aparelhos distintos de BIA: RJL , BIO e Tanita e pela DXA. Os componentes101450BC 533corporais medidos foram: massa livre de gordura (MLG), massa gorda (MG) e percentual degordura corporal (%GC). Na análise estatística foram calculadas as médias e desvio-padrãodas variáveis contínuas. A concordância entre os componentes corporais determinados pelaDXA e cada BIA foi avaliada pelo método de Bland & Altman e pelo coeficiente decorrelação de concordância (CCC). Para comparação de médias das variáveis obtidas por BIAe DXA para cada faixa de índice de massa corporal (IMC), foi aplicada a ANOVA e oadotado o teste post-hoc de Tukey. O nível de significância adotado foi de 95% (p=0,05). Amédia ( desvio padrão) de idade foi de 25,5 4,6 anos, a MC de 73,6 12,2kg, o IMC de28,7 4,3kg/m, a MG de 29,87,4kg, a MLG de 43,25,7kg e o %GC de 41,84,3%,obtidos pelo DXA. Ao comparar-se os resultados dos diferentes equipamentos com o método padrão-ouro, verificou-se que houve diferença significativa entre a DXA e as BIA para todos componentes corporais, com exceção da MG fornecida pelo RJL (27,1Kg) e TAN (27,1Kg)em relação à DXA (29,8Kg). Os resultados mostraram haver uma boa reprodutibilidade emrelação aos aparelhos de BIA TAN (r=0,74; r=0,90) e RJL (r=0,78; r=0,89) para MLG e MG.Verificou-se que os equipamentos de BIA TAN e RJL forneceram estimativas semelhantes em relação à MLG, MG e %GC. Em relação aos valores da DXA o equipamento que mais se aproximou foi a TAN e o RJL quando avaliada a MG considerando todas as mulheres, mas quando estratificadas segundo o IMC, a análise foi mais acurada em mulheres obesas.Entretanto, a concordância não foi satisfatória entre os componentes corporais fornecidos pelas BIA em relação à DXA. As BIAs avaliadas no presente estudo subestimaram o %GC e superestimaram a MLG para esse grupo de mulheres no período pós-parto. Conclui-se que as BIA avaliadas não são recomendadas para avaliação da CC neste grupo de mulheres no período pós-parto. / Postpartum women are at risk of body weight retention and consequently becoming obese. Usually, during postpartum period there is a greater concern in weight loss instead of measuring which body compartment is being mobilized. Thus, there is a growing interesting to validate field and affordable techniques, such as the bioelectrical impedance (BIA) to determine body composition in this segment of the population. The purpose of this study was to validate different BIA devices using dual-energy x-ray absorptiomety (DXA) as a goldstandard in postpartum women. Forty-six postpartum women aged 18 years and over were enrolled in the study. They were recruited soon after delivery from two health units (Hospital São José of Mesquita District and Policlínica Piquet Carneiro, located in Rio de Janeiro city).All measurements were performed at the Laboratório Interdisciplinar de Avaliação Nutricional da Universidade do Estado do Rio de Janeiro. Participants were instructed to follow a standardized protocol for body composition measurements. Anthropometric variables(body mass - BM, stature, waist and hip circumferences) were collected. Body composition was determined by DXA and also obtained using the following BIA devices :model RJL 101(RJL Systems, Inc. Clinton, USA), model BIOD 450 (Biodynamics Corporation, USA)and I model BC 533 (Tanita, USA). Descriptive statistical analysis was done for continuous variables. ANOVA was used to verify differences between mean values of fat free mass(FFM), fat mass (FM) and percentage body fat (%BF) within BIA devices and DXA. Concordance analysis between each body component obtained by DXA and all BIA devices were performed using Bland & Altman plots and the Concordance Correlation Coefficient(CCC). ANOVA was used to compare mean values within BIA and DXA, and Tukey post-hoc was adopted. SPSS and MedCalc software were used in the analysis. Mean values (standard deviation) of age, BM, body mass index, FM by DXA, FFM by DXA, %BF by DXA were 25.5 4.6 years, 73.6 12.2kg, 28.7 4.3kg/m, 29.87.4kg, 43.2 5.7kg, 41.8 4.3%,respectively. When comparing the results within different equipments (DXA, RJL, BIOD and TAN), it was verified that there was significant difference between DXA and BIA equipments for all body components, except for MG from RJL (27.1Kg) and TAN (27.1Kg) in relation toD XA (29.8Kg). The results showed good reproducibility in relation to BIA TAN (FFM, r=0.74; FM, r=0.90) and RJL (FFM, r=0.78; FM, r=0.89). It was verified that BIA TAN and RJL yielded similar estimates for FFM, FM and % BF. When all women were considered together no significant difference was observed for FM obtained by TAN, RJL and DXA. When considering BMI categories the estimates were better for obese women. However, the agreement was not satisfactory for body components supplied by BIA in relation to DXA. All BIA devices tended to underestimated % BF and overestimated FFM for this sample.
5

Desenvolvimento de equações preditivas de composição corporal para obesos graves: uso da bioimpedância elétrica / Development of body composition prediction equations for severely obese patients: the use of bioelectrical impedance

Horie, Lilian Mika 26 September 2008 (has links)
INTRODUÇÃO: A obesidade grave dificulta fisicamente a avaliação da composição corporal. OBJETIVO: Desenvolver equações para estimativa de gordura corporal (GC) em obesos grau III. MÉTODOS: Adultos obesos graves tiveram a GC estimada por bioimpedância elétrica (BIA impedância de 5, 50, 100 e 200kHz) e por método de referência (pletismografia de deslocamento aéreo - PDA). Avaliaram-se os limites de concordância e seu coeficiente de correlação (CCC). Novas equações preditivas foram desenvolvidas por análise de regressão multivariada. RESULTADOS: A GC estimada por BIA e PDA foi similar para a população estudada (64,8 ± 15kg vs 65,6 ± 16kg, p>0,05). Ambas tiveram boa acurácia, precisão e CCC, porém a sua comparação teve amplos limites de concordância que variaram de -10,4 a 8,8kg. A equação residente de BIA aplicada em mulheres superestimou a GC (-1,3 kg; p<0,05) e em homens subestimou a GC (5,6 kg; p<0,05). Novas equações preditivas de GC foram criadas, para BIA de freqüência de 50kHz, Horie-Waitzberg & Barbosa-Silva1: GC1 (kg) = 23,25 + (0,13 × idade) + (1,00 × peso atual) + (0,09 × Resistência 50kHz) (0,80 × altura) e para BIA de frequência de 100kHz, Horie-Waitzberg & Barbosa-Silva2: GC2 (kg) = 23,97 + (0,10 × Impedância 100kHz) + (0,11 × idade) + (0,99 × peso atual) - (0,80 × altura). CONCLUSÕES: A equação residente no aparelho de BIA foi inadequada para estimar a GC em pacientes obesos grau III. As equações desenvolvidas especialmente para esta população forneceram estimativas de GC mais precisas (melhores limites de concordância, precisão, acurácia e CCC). / RATIONALE: Severe obesity limits physically the body composition assessment. AIM: To develop equations of body fat (BF) estimative in severe obesity. METHODS: Severely obese adults had BF estimated by bioelectrical impedance (BIA impedance of 5, 50, 100 and 200kHz) and reference method (air displacement plethysmography - ADP). The limits of agreement and of concordance correlation coefficient (CCC) of the data were evaluated. New predictive equations were developed by multivariate regression analysis. RESULTS: The BF estimations from BIA and ADP were similar for the studied population (64.8 ± 15kg vs 65.6 ± 16.4kg, p>0.05). Both had good accuracy, precision, and CCC, but their comparison had wide limit of agreement with range from -10.4 to 8.8kg. The home BIA equation overestimated BF in women (-1.3 kg, p<0,05) and underestimated BF in men (5.6 kg; p <0.05). BF new predictive equations were generated, for BIA with 50kHz frequency, Horie- Waitzberg & Barbosa-Silva1: BF1 (kg) = 23.25 + (0.13 × age) + (1.00 × current weight) + (0.09 × Resistance 50kHz) (0.80 × height) and for BIA with 100kHz frequency, Horie-Waitzberg & Barbosa-Silva2: BF2 (kg) = 23.97 + (0.10 × Impedance 100kHz) + (0.11 × age) + (0.99 × current weight) - (0.80 × height). CONCLUSIONS: The home equation on BIA was inadequate for estimating BF in severely obese patients. Equations developed especially for this population provides more accurate BF estimative (better limits of agreement accuracy, precision and CCC).
6

Análise de parâmetros de impedância bioelétrica, bioquímicos, morfológicos e funcionais em idosos sarcopênicos e não sarcopênicos submetidos a treinamento resistido convencional e com resistência elástica : ensaio clínico aleatório /

Osco, Karla Minacca January 2019 (has links)
Orientador: Luís Alberto Gobbo / Resumo: A população idosa com idade igual ou superior a 60 anos dobrou na última metade do século XX. O envelhecimento é um processo inevitável com consequências deletérias e progressivas para o corpo humano, comprometendo os seus diferentes sistemas, tais como o fisiológico, o morfológico, o funcional e o endócrino. A perda progressiva de massa e força muscular, associada à função é denominada sarcopenia, e como consequência, promove maior risco para incapacidade funcional, fragilidade, quedas, fraturas, hospitalizações, institucionalizações, óbito precoce e alterações imunológicas. Em idosos as alterações no sistema imunológico podem ocorrer devido ao aumento da concentração sanguínea de citocinas pró-inflamatórias que agrava o estado sarcopênico, acarretando um processo de inflamação crônica de baixo grau (LGI, low grade inflammation). Dentre os parâmetros observados na avaliação da sarcopenia, a análise de impedância bioelétrica (BIA) vem sendo utilizada há tempo para mensuração dos diferentes componentes corporais dentro do sistema morfológico, especialmente os tecidos adiposo e muscular. Mais recentemente, parâmetros brutos da BIA (R, resistência e Xc, reatância) têm sido utilizados para a avaliação da saúde celular (PhA, ângulo de fase e a análise de vetores de impedância bioelétrica (BIVA, bioimpedance vector analysis). Com a finalidade de reverter ou atenuar os efeitos deletérios do envelhecimento, programas de treinamento físico, mais especificamente o treinamento resistido... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
7

Validação de Índice de Massa Corporal (IMC) ajustado pela massa gorda obtido por impedância bioelétrica / Validation of body mass index (BMI) adjusted for fat mass using the bioelectrical impedance analysis.

Grecco, Mirele Savegnago Mialich 22 June 2012 (has links)
A obesidade é definida como o excesso de tecido adiposo e o IMC tem sido um dos métodos mais utilizados para o diagnóstico de obesidade devido sua facilidade de aplicação e baixo custo. Entretanto, este índice possui a grande limitação de não diferenciar tecido adiposo e massa livre de gordura. Este trabalho buscou validar o Índice de Massa Corporal ajustado pela massa gorda obtido por impedância bioelétrica previamente desenvolvido por Mialich et al., 2011. Foi realizado um estudo transversal com 501 indivíduos, de ambos os gêneros, com faixa etária entre 17 e 38 anos, matriculados em cursos de graduação da USP do campus de Ribeirão Preto. Os indivíduos foram submetidos à aferição de peso, estatura e a avaliação de composição corporal através do equipamento de impedância bioelétrica. Além disso, foram coletadas informações referentes ao padrão alimentar por meio da aplicação de um questionário desenvolvido pelos pesquisadores, e também referente à prática de atividade física através da utilização do questionário IPAQ. A participação dos alunos foi voluntária e todos os indivíduos foram avaliados somente 1 vez no estudo e por um grupo de examinadores treinados. Para validação foi utilizado o modelo de regressão linear, sendo o IMC ajustado a variável independente e o IMC tradicional a variável dependente. A amostra era composta por 366 mulheres e 135 homens e apresentou médias de idade de 20,8 ± 3,2 anos e 20,3 ± 2,7 anos; peso 76,9 Kg ± 13,6 e 57,8 Kg ± 9,2; estatura 177,3 cm ± 6,7 e 163,1 cm ± 6,3; IMC 24,4 ± 3,8 Kg/m2 e 21,7 ± 3,0 Kg/m2; massa livre de gordura, 60,0 Kg ± 7,7 e 39,8 Kg ± 3,8; massa gorda 17,0 % ± 6,2 e 26,6 % ± 6,2, para homens e mulheres, respectivamente. Com relação à validação foram verificados valores elevados e satisfatórios de R2 sendo, 91,1%, 91,9% e 88,8%, considerando todos os indivíduos, homens e mulheres, respectivamente. Foram definidas também novas faixas de classificação do estado nutricional para ambos os gêneros, considerando este novo IMC ajustado, sendo: 1,35 a 1,65 (risco nutricional para subnutrição), > 1,65 e 2,0 (eutrofia) e > 2,0 (obesidade). Verificou-se também que este novo índice possui uma capacidade mais acurada de captar indivíduos obesos (0,980; 0,993; 0,974), considerando todos os indivíduos, mulheres e homens, respectivamente, e os pontos de corte para gordura corporal de 25% (homens) e 35% (mulheres), em detrimento ao IMC tradicional (0,932; 0,956; 0,95). Além disso, este trabalho possibilitou a definição de novos de pontos de corte do IMC tradicional para a classificação de obesidade, sendo: 25,24 Kg/m2 e 28,38 Kg/m2, para mulheres e homens, respectivamente. O novo IMC ajustado foi validado para a população estudada e pode ser adotado na prática clínica. Novos estudos devem buscar a sua aplicação em diferentes etnias assim como a comparação deste índice com outros já descritos previamente na literatura científica. / Obesity is defined as the excess fat and BMI has been one of the most widely used methods for the diagnosis of obesity because of its ease of application and low cost. However, this index has a major limitation of not differentiating adipose tissue and fat- free mass. This study aimed to validate the Body Mass Index adjusted for fat mass obtained by bioelectrical impedance analysis previously developed by Mialich et al., 2011. We conducted a cross-sectional study with 501 subjects of both genders, aged between 17 and 38 years, enrolled in graduate courses at the USP campus at Ribeirao Preto. The subjects underwent measurement of weight, height and body composition assessment by bioelectrical impedance analysis. In addition, information was collected regarding the eating pattern by applying a questionnaire develops by the researchers, and also on the physical activity questionnaire using the IPAQ. The student participation was voluntary and all subjects were evaluated only one time in the study and by a group of trained examiners. For validation we used the linear regression model, being the BMI-adjusted the independent variable and BMI-traditional the dependent variable. The sample consisted of 366 women and 135 men and it had a mean age of 20.8 ± 3.2 years and 20.3 ± 2.7 years, weight 76.9 ± 13.6 kg and 57.8 ± 9.2 kg, height 177.3 ± 6.7 cm and 163.1 ± 6.3 cm, BMI 24.4 ± 3.8 kg/m2 and 21.7 ± 3.0 kg/m2, fat-free mass, 60.0 ± 7.7 kg and 39.8 ± 3.8 kg, fat mass 17.0 ± 6.2% and 26.6 ± 6.2% for men and women, respectively. With respect to validation were found high and satisfactory R2 values, 91.1%, 91.9% and 88.8%, considering all individuals, men and women, respectively. We also defined new range classification of nutritional status for both genders, considering this new BMI, as follows: 1.35 to 1.65 (nutritional risk for malnutrition), > 1.65 and 2.0 (normal) and > 2.0 (obesity). It was also found that this new index has the capacity to capture more accurate obese subjects (0.980, 0.993, 0.974) whereas all individuals, men and women, respectively, and the cutoff points for body fat of 25% (men) and 35% (women), rather than the traditional BMI (0.932, 0.956, 0.95). Moreover, this study allowed the definition of new points to traditional BMI cutoff for the classification of obesity, and: 25.24 kg/m2 and 28.38 kg/m2 for women and men, respectively. The new BMI set was validated for the population studied and may be adopted in clinical practice. Further studies should seek their implementation in different ethnic groups as well as the comparison of this index with other previously described in the literature.
8

Validação de Índice de Massa Corporal (IMC) ajustado pela massa gorda obtido por impedância bioelétrica / Validation of body mass index (BMI) adjusted for fat mass using the bioelectrical impedance analysis.

Mirele Savegnago Mialich Grecco 22 June 2012 (has links)
A obesidade é definida como o excesso de tecido adiposo e o IMC tem sido um dos métodos mais utilizados para o diagnóstico de obesidade devido sua facilidade de aplicação e baixo custo. Entretanto, este índice possui a grande limitação de não diferenciar tecido adiposo e massa livre de gordura. Este trabalho buscou validar o Índice de Massa Corporal ajustado pela massa gorda obtido por impedância bioelétrica previamente desenvolvido por Mialich et al., 2011. Foi realizado um estudo transversal com 501 indivíduos, de ambos os gêneros, com faixa etária entre 17 e 38 anos, matriculados em cursos de graduação da USP do campus de Ribeirão Preto. Os indivíduos foram submetidos à aferição de peso, estatura e a avaliação de composição corporal através do equipamento de impedância bioelétrica. Além disso, foram coletadas informações referentes ao padrão alimentar por meio da aplicação de um questionário desenvolvido pelos pesquisadores, e também referente à prática de atividade física através da utilização do questionário IPAQ. A participação dos alunos foi voluntária e todos os indivíduos foram avaliados somente 1 vez no estudo e por um grupo de examinadores treinados. Para validação foi utilizado o modelo de regressão linear, sendo o IMC ajustado a variável independente e o IMC tradicional a variável dependente. A amostra era composta por 366 mulheres e 135 homens e apresentou médias de idade de 20,8 ± 3,2 anos e 20,3 ± 2,7 anos; peso 76,9 Kg ± 13,6 e 57,8 Kg ± 9,2; estatura 177,3 cm ± 6,7 e 163,1 cm ± 6,3; IMC 24,4 ± 3,8 Kg/m2 e 21,7 ± 3,0 Kg/m2; massa livre de gordura, 60,0 Kg ± 7,7 e 39,8 Kg ± 3,8; massa gorda 17,0 % ± 6,2 e 26,6 % ± 6,2, para homens e mulheres, respectivamente. Com relação à validação foram verificados valores elevados e satisfatórios de R2 sendo, 91,1%, 91,9% e 88,8%, considerando todos os indivíduos, homens e mulheres, respectivamente. Foram definidas também novas faixas de classificação do estado nutricional para ambos os gêneros, considerando este novo IMC ajustado, sendo: 1,35 a 1,65 (risco nutricional para subnutrição), > 1,65 e 2,0 (eutrofia) e > 2,0 (obesidade). Verificou-se também que este novo índice possui uma capacidade mais acurada de captar indivíduos obesos (0,980; 0,993; 0,974), considerando todos os indivíduos, mulheres e homens, respectivamente, e os pontos de corte para gordura corporal de 25% (homens) e 35% (mulheres), em detrimento ao IMC tradicional (0,932; 0,956; 0,95). Além disso, este trabalho possibilitou a definição de novos de pontos de corte do IMC tradicional para a classificação de obesidade, sendo: 25,24 Kg/m2 e 28,38 Kg/m2, para mulheres e homens, respectivamente. O novo IMC ajustado foi validado para a população estudada e pode ser adotado na prática clínica. Novos estudos devem buscar a sua aplicação em diferentes etnias assim como a comparação deste índice com outros já descritos previamente na literatura científica. / Obesity is defined as the excess fat and BMI has been one of the most widely used methods for the diagnosis of obesity because of its ease of application and low cost. However, this index has a major limitation of not differentiating adipose tissue and fat- free mass. This study aimed to validate the Body Mass Index adjusted for fat mass obtained by bioelectrical impedance analysis previously developed by Mialich et al., 2011. We conducted a cross-sectional study with 501 subjects of both genders, aged between 17 and 38 years, enrolled in graduate courses at the USP campus at Ribeirao Preto. The subjects underwent measurement of weight, height and body composition assessment by bioelectrical impedance analysis. In addition, information was collected regarding the eating pattern by applying a questionnaire develops by the researchers, and also on the physical activity questionnaire using the IPAQ. The student participation was voluntary and all subjects were evaluated only one time in the study and by a group of trained examiners. For validation we used the linear regression model, being the BMI-adjusted the independent variable and BMI-traditional the dependent variable. The sample consisted of 366 women and 135 men and it had a mean age of 20.8 ± 3.2 years and 20.3 ± 2.7 years, weight 76.9 ± 13.6 kg and 57.8 ± 9.2 kg, height 177.3 ± 6.7 cm and 163.1 ± 6.3 cm, BMI 24.4 ± 3.8 kg/m2 and 21.7 ± 3.0 kg/m2, fat-free mass, 60.0 ± 7.7 kg and 39.8 ± 3.8 kg, fat mass 17.0 ± 6.2% and 26.6 ± 6.2% for men and women, respectively. With respect to validation were found high and satisfactory R2 values, 91.1%, 91.9% and 88.8%, considering all individuals, men and women, respectively. We also defined new range classification of nutritional status for both genders, considering this new BMI, as follows: 1.35 to 1.65 (nutritional risk for malnutrition), > 1.65 and 2.0 (normal) and > 2.0 (obesity). It was also found that this new index has the capacity to capture more accurate obese subjects (0.980, 0.993, 0.974) whereas all individuals, men and women, respectively, and the cutoff points for body fat of 25% (men) and 35% (women), rather than the traditional BMI (0.932, 0.956, 0.95). Moreover, this study allowed the definition of new points to traditional BMI cutoff for the classification of obesity, and: 25.24 kg/m2 and 28.38 kg/m2 for women and men, respectively. The new BMI set was validated for the population studied and may be adopted in clinical practice. Further studies should seek their implementation in different ethnic groups as well as the comparison of this index with other previously described in the literature.
9

Desenvolvimento de equações preditivas de composição corporal para obesos graves: uso da bioimpedância elétrica / Development of body composition prediction equations for severely obese patients: the use of bioelectrical impedance

Lilian Mika Horie 26 September 2008 (has links)
INTRODUÇÃO: A obesidade grave dificulta fisicamente a avaliação da composição corporal. OBJETIVO: Desenvolver equações para estimativa de gordura corporal (GC) em obesos grau III. MÉTODOS: Adultos obesos graves tiveram a GC estimada por bioimpedância elétrica (BIA impedância de 5, 50, 100 e 200kHz) e por método de referência (pletismografia de deslocamento aéreo - PDA). Avaliaram-se os limites de concordância e seu coeficiente de correlação (CCC). Novas equações preditivas foram desenvolvidas por análise de regressão multivariada. RESULTADOS: A GC estimada por BIA e PDA foi similar para a população estudada (64,8 ± 15kg vs 65,6 ± 16kg, p>0,05). Ambas tiveram boa acurácia, precisão e CCC, porém a sua comparação teve amplos limites de concordância que variaram de -10,4 a 8,8kg. A equação residente de BIA aplicada em mulheres superestimou a GC (-1,3 kg; p<0,05) e em homens subestimou a GC (5,6 kg; p<0,05). Novas equações preditivas de GC foram criadas, para BIA de freqüência de 50kHz, Horie-Waitzberg & Barbosa-Silva1: GC1 (kg) = 23,25 + (0,13 × idade) + (1,00 × peso atual) + (0,09 × Resistência 50kHz) (0,80 × altura) e para BIA de frequência de 100kHz, Horie-Waitzberg & Barbosa-Silva2: GC2 (kg) = 23,97 + (0,10 × Impedância 100kHz) + (0,11 × idade) + (0,99 × peso atual) - (0,80 × altura). CONCLUSÕES: A equação residente no aparelho de BIA foi inadequada para estimar a GC em pacientes obesos grau III. As equações desenvolvidas especialmente para esta população forneceram estimativas de GC mais precisas (melhores limites de concordância, precisão, acurácia e CCC). / RATIONALE: Severe obesity limits physically the body composition assessment. AIM: To develop equations of body fat (BF) estimative in severe obesity. METHODS: Severely obese adults had BF estimated by bioelectrical impedance (BIA impedance of 5, 50, 100 and 200kHz) and reference method (air displacement plethysmography - ADP). The limits of agreement and of concordance correlation coefficient (CCC) of the data were evaluated. New predictive equations were developed by multivariate regression analysis. RESULTS: The BF estimations from BIA and ADP were similar for the studied population (64.8 ± 15kg vs 65.6 ± 16.4kg, p>0.05). Both had good accuracy, precision, and CCC, but their comparison had wide limit of agreement with range from -10.4 to 8.8kg. The home BIA equation overestimated BF in women (-1.3 kg, p<0,05) and underestimated BF in men (5.6 kg; p <0.05). BF new predictive equations were generated, for BIA with 50kHz frequency, Horie- Waitzberg & Barbosa-Silva1: BF1 (kg) = 23.25 + (0.13 × age) + (1.00 × current weight) + (0.09 × Resistance 50kHz) (0.80 × height) and for BIA with 100kHz frequency, Horie-Waitzberg & Barbosa-Silva2: BF2 (kg) = 23.97 + (0.10 × Impedance 100kHz) + (0.11 × age) + (0.99 × current weight) - (0.80 × height). CONCLUSIONS: The home equation on BIA was inadequate for estimating BF in severely obese patients. Equations developed especially for this population provides more accurate BF estimative (better limits of agreement accuracy, precision and CCC).
10

DETERMINAÇÃO E CONCORDÂNCIA DOS COMPONENTES DA COMPOSIÇÃO CORPORAL OBTIDOS A PARTIR DE DIFERENTES MÉTODOS AVALIATIVOS / DETERMINATION AND AGREEMENT OF BODY COMPOSITION COMPONENTS OBTAINED FROM DIFFERENT EVALUATION METHODS

Both, Diego Rodrigo 27 February 2014 (has links)
Body composition has been shown to be an important indicator of health, since many chronic diseases are related to excess adiposity. In this context the appropriate assessment is required in order to obtain the correct diagnosis in terms of nutritional status. Thus, the aim of this study was to analyze the relationship between the components of body composition of college students in the city of Santa Maria, RS obtained from hydrostatic weighing (HW), bioelectrical impedance (BI) and anthropometry and agreement between shown diagnostics. The study included 164 college students (104 men and 60 women) aged between 18 and 30 years. For the determination of body composition, subjects were evaluated by means of HW, BI and anthropometry (weight, height, skinfolds thickness, body circumferences, and bone breadths), and analyzed 48 equations (32 generalized and 16 specific) for review the percentage of body fat (%BF), 7 equations of lean body mass (LBM), two of muscle mass (MM) and two bone mass (BM). Descriptive statistics, the Kolmogorov - Smirnov test, the t test for dependent samples, the Pearson correlation coefficient , the standard error of estimate, the total error and constant error of the scatter diagram was used as well, Bland - Altman (1986) and the kappa coefficient to verify the concordance of the results. The level of significance was set at 5%. Data analysis was performed with SPSS, version 14.0. The average %BF was found to be 16.3% in men and 26.3% women. As for the agreement, the generalized equations demonstrated greater power of the relative body fat, 16 equations (9 men and 7 for women) Petroski (1995) showed no significant difference data obtained using the method, as well as an equation Guedes and Guedes (1991) for women and BI for men. The kappa coefficient of concordance observed was low (≤0.44) having few overlapping diagnoses. MCM obtained by different equations differed from results obtained with the criterion method, as compared to BI (body composition analyzer), only the results obtained for men did not differ from the criterion method. The equations of MM Janssen et al. (2000) and Lee et al. (2000) showed a correlation coefficient of r = 0.72 for men and r = 0.76 for women, and no statistical difference was observed. BM already obtained by means of equations Von Döbeln modified by Rocha (1975) and Martin (1991) showed statistically different results. Based on the results we conclude that: a) for the determination of %BF equation Petroski (1995) that uses variables as the sum of nine skinfolds thickness and age, for men, and employing the sum of three skinfold thickness and age, for women were those that showed the best results in agreement with the reference method, however, the diagnostic showed up just the same; b) LBM provided by body composition analyzer proved acceptable for men, whereas for females the results were not satisfactory; c) the MM results presented good agreement between the equations for both genders; and d) the equations of BM demonstrate different results, both when analyzing the female group, as the male group. / A composição corporal tem se mostrado um importante indicador de saúde, visto que muitas doenças crônicas estão relacionadas ao excesso de adiposidade. Neste contexto a avaliação adequada é necessária, com o intuito de se obter o diagnóstico correto em termos de estado nutricional. Desse modo, o objetivo deste estudo foi analisar a relação entre os componentes da composição corporal de estudantes universitários da cidade de Santa Maria, RS obtidos a partir da pesagem hidrostática (PH), da impedância bioelétrica (IB) e da antropometria e a concordância entre os diagnósticos evidenciados. Participaram deste estudo 164 universitários (104 homens e 60 mulheres) com idade entre 18 e 30 anos. Para a determinação da composição corporal, os indivíduos foram avaliados por meio da PH, da IB e da antropometria (massa corporal, estatura, dobras cutâneas, perímetros corporais e diâmetros ósseos), sendo analisadas 48 equações (32 generalizadas e 16 específicas) para avaliação do percentual de gordura corporal (%GC), 7 equações de massa corporal magra (MCM), duas de massa muscular (MM) e duas de massa óssea (MO). Foi utilizada a estatística descritiva, o teste de normalidade de Kolmogorov-Smirnov, o teste t para amostras dependentes, o coeficiente de correlação de Pearson, o erro padrão de estimativa, o erro total e o erro constante, bem como, o diagrama de dispersão de Bland-Altman (1986) e o coeficiente kappa para verificar a concordância dos resultados. O nível de significância adotado foi de 5%. A análise dos dados foi feita com o programa SPSS, versão 14.0. O %GC médio encontrado foi de 16,3% nos homens e 26,3% nas mulheres. Com relação à concordância, as equações generalizadas demonstraram maior poder de precisão da gordura corporal relativa, 16 equações (9 para homens e 7 para mulheres) de Petroski (1995) não apresentaram diferença significativa dos dados obtidos com o método critério, bem como uma equação de Guedes e Guedes (1991) para as mulheres e a IB para os homens. O coeficiente de concordância kappa observado foi baixo (≤0,44), apresentando poucos diagnósticos coincidentes. A MCM obtida pelas diferentes equações diferiu estatisticamente do resultado obtido com o método critério, já em relação a IB (analisador de composição corporal), apenas os resultados obtidos para os homens não diferiu do método critério. As equações de MM de Janssen et al. (2000) e Lee et al. (2000) apresentaram coeficiente de correlação de r=0,72 para os homens e r=0,76 para as mulheres, bem como não foi observada diferença estatística. Já a MO obtida por meio das equações de Von Döbeln modificada por Rocha (1975) e de Martin (1991) demonstraram resultados estatisticamente diferentes. Com base nos resultados obtidos foi possível concluir que: a) para a determinação do %GC a equação de Petroski (1995) que utiliza como variáveis o somatório da espessura de nove dobras cutâneas e a idade, para os homens, e a que emprega o somatório da espessura de três dobras cutâneas e a idade, para as mulheres, foram as que demonstraram os melhores resultados de concordância com o método de referência, no entanto, os diagnósticos apresentaram-se pouco coincidentes; b) a MCM fornecida pelo analisador de composição corporal mostrou-se aceitável para os homens, já para o grupo feminino os resultados obtidos não foram satisfatórios; c) os resultados de MM apresentaramse concordantes entre as equações em ambos os sexos; e d) as equações de MO demonstram resultados distintos, tanto ao analisar o grupo feminino, quanto o grupo masculino.