• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • Tagged with
  • 9
  • 9
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da utilização de diferentes materiais suporte na biofiltração de sulfeto de hidrogênio / Utilization of different packing materials in the hydrogen sulfide biofiltration

Pantoja Filho, Jorge Luis Rodrigues 25 April 2008 (has links)
O sulfeto de hidrogênio é um gás que pode causar os mais diversos danos se lançado ao meio ambiente devido, principalmente, à sua elevada toxicidade, corrosividade, odores indesejáveis e alta demanda de oxigênio. Atualmente existem diferentes processos físico-químicos estabelecidos para o tratamento desse composto, entretanto são consideradas técnicas onerosas do ponto de vista econômico e ambiental. Os processos biológicos constituem-se como uma alternativa bastante interessante quando comparados aos processos físico-químicos, sendo que a biofiltração é o processo mais amplamente utilizado. Neste trabalho, foram avaliados três tipos diferentes de materiais suporte, sendo um sintético - espuma de poliuretano - e dois orgânicos - fibra de côco e bagaço de cana -, para a biofiltração de uma mistura gasosa contendo \'H IND.2\'S\'. Como inóculo, optou-se pela utilização de cultura mista originária de duas fontes: a) unidade de biofiltro aerado submerso pertencente ao Serviço Autônomo de Água e Esgoto da Cidade de São Carlos, b) unidade de lodos ativados pertencente a São Carlos S/A - Indústria de Papel e Celulose. A adaptação do inóculo foi realizada em meio nutriente específico. Foi observado um período de partida de somente 2 dias nos três sistemas. Com o intuito de avaliar o impacto do aumento progressivo das taxas de carregamento mássico no desempenho dos três biofiltros, os mesmos foram submetidos a taxas de 19, 32, 54 e 70 g/m³.h (concentrações afluentes médias de 184, 328, 526 e 644 ppm para tempo de retenção do gás de, aproximadamente, 50 segundos). As eficiências remoção média em todos os sistemas mantiveram-se sempre acima dos 99,3%. A capacidade eliminação máxima alcançada pelos biofiltros oscilou entre 74 e 80 g/m³.h. As perdas de carga verificadas no ensaio hidrodinâmico foram baixas, variando entre 0,59.\'10 POT.-2\' a 0,68 \'10 POT.-2\' mca, para a velocidade superficial utilizada durante o estudo. O modelo matemático empregado na previsão do desempenho dos sistemas ajustou-se bem aos dados experimentais. Portanto, pode-se concluir que os materiais suportes testados são adequados para a biofiltração de sulfeto de hidrogênio. / Hydrogen sulfide is a gas which has high restrictions regarding to its disposal in the environment, mainly, because of its high toxicity, malodors, high oxygen demand, etc. Currently, there are many different physical-chemical processes established in order to treat this compound, nevertheless they are considered expensive techniques by the point of economical and environmental views. Biological processes are very interesting alternatives when they are compared to the physical-chemical ones, and biofiltration is the most used process. In this work, three different materials as support media were evaluated, - a synthetic one - represented by the polyurethane foam, - two organic ones - represented by coconut fiber and sugar bagasse -, for a biofiltration of a gaseous mixture containing \'H IND.2\'S\'. Microorganisms were obtained from two sources: a) submerged aerated biofilter unit, b) activated sludge unit. Inoculum\'s adaptation was realized in specific nutrient media. It was observed a 2 days start-up period in the three systems. In order to evaluate some impact caused by the progressive increasing of mass loading rate on the biofilters performance, were applied rates of 19, 32, 54 e 70 g/m³.h (average influent concentrations of 184, 328, 526 e 644 ppm to the empty bed retention time of, approximately, 50 seconds). Average removal efficiencies in the systems were always above 99,3%. Maximum elimination capacities reached by the biofilters were in the range of 74 e 80 g/m³.h. Loss pressure verified by the hands of hydrodynamic essays varied between 0,59.\'10 POT.-2\' a 0,68.\'10 POT.-2\' mca, to a superficial velocity utilized during the work. Mathematical model used to predict the performance of the systems fitted reasonably the experimental data. Then, it can be concluded that the three packing materials are appropriated for the hydrogen sulfide biofiltration.
2

REMOÇÃO BIOLÓGICA DE GÁS SULFÍDRICO CONCENTRADO PARA TRATAMENTO DO BIOGÁS / BIOLOGICAL REMOVEL OF CONCENTRATE HYDROGEN SULFIDE FOR TREATMENT OF BIOGAS

Araujo, Gabriele Monego 12 April 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The biogas is a product of the microbiological degradation process of organic matter. Biogas consists mainly in methane, carbon dioxide and small amounts of hydrogen, nitrogen and hydrogen sulfide. The high methane concentration in biogas made it an attractive fuel and its use solves a problem of emission, since methane has a polluting effect superior than of carbon dioxide. The hydrogen sulfide, although present in small amounts, is a toxic and highly corrosive gas, and besides being a major pollutants of the atmosphere. In this sense, this work is dedicated to investigate the removal efficiency for H2S biofiltration process in a synthetic biogas flow. The biological processes it is an interesting alternative as compared to physical-chemical processes, and the biofiltration represents the most widely used. Performed an experimental bioreactor biofilter model and evaluated vegetable sponge as a packing for immobilization of microorganisms of the genus T. thioparus and activated sludge as medium for acclimatization of bacteria. The experiment took place within 31 days, with a flow gas of 0.02 m³.h-1, a residence time of empty bed of 190s and an affluent concentration of 10000 ppmv. During the study the system temperature kept in mesophilic range registering 28.3°C as average, however the pH range preserved below of recommended at T. thioparus bacteria, reaching pH = 2.48. The moisture of the environment remained around 55%. The removal efficiency achieved was 67% corresponding to an effluent concentration of 3314 ppm to an elimination capacity of 177 g.m-3h-1. However, the final concentration of methane decreases from 59.9% to 49.5% this is explained by the dilution of the gas by supplied air system, which is essential to feed the microbiological requirements for the H2S oxidation. The results show that it is possible to apply the vegetable sponge to biofiltration of H2S. / O biogás é um produto do processo da degradação microbiológica da matéria orgânica. Este gás consiste principalmente em metano, dióxido de carbono e pequenas quantidades de hidrogênio, nitrogênio e sulfeto de hidrogênio. A alta concentração de metano faz com que o biogás seja um combustível atraente e o seu uso resolve um problema de emissão, já que o metano tem um efeito poluente superior ao dióxido de carbono. O sulfeto de hidrogênio, embora esteja presente em pequenas quantidades, é um gás altamente tóxico e corrosivo, além de ser um dos maiores poluentes da atmosfera. Nesse sentido, dedicou-se este trabalho a investigar a eficiência de remoção de H2S por processo de biofiltração em um fluxo de biogás sintético. Os processos biológicos constituem-se como uma alternativa bastante interessante quando comparados aos processos físico-químicos, sendo que a biofiltração é o processo mais amplamente utilizado. Realizou-se estudo experimental em biorreator modelo biofiltro e avaliou-se como meio suporte esponja natural para imobilização dos microrganismos do gênero T. thioparus e lodo ativado como meio para aclimatação das bactérias. O experimento decorreu no período de 31 dias, com uma vazão de 0,02 m³.h-1, um tempo de residência do leito vazio de 190s, e uma concentração de afluente de 10000 ppmv. Durante o estudo a temperatura do sistema manteve-se na faixa mesofílica registrando-se uma média de 28,3°C, porém o pH conservou-se em um faixa abaixo da recomendada para bactérias T.thioparus, atingindo pH = 2,48. A umidade do meio permaneceu em torno de 55%. A eficiência de remoção atingida foi de 67% correspondendo a uma concentração efluente de 3314 ppmv para uma capacidade de eliminação de 177 g.m-3h-1. Entretanto, a concentração final de metano diminui de 59,9% para 49,5% isso se explica pela diluição do gás pelo ar fornecido ao sistema, o qual é essencial para suprir as necessidades microbiológicas requeridas para a oxidação do H2S. Os resultados mostram que é possível utilizar a esponja natural para biorremoção do H2S.
3

USO DE BIOFILTRAÇÃO NA REMOÇÃO DO SULFETO DE HIDROGÊNIO PRESENTE NO BIOGÁS / USE OF BIOFILTRATION IN THE REMOVAL OF HYDROGEN SULPHIDE IN BIOGAS

Aita, Bruno Carlesso 23 April 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Biogas is an end product of anaerobic degradation of organic substances and has limited use in power generation mainly due to the presence of hydrogen sulfide (H2S). Currently, most of the techniques employed in the removal of H2S from biogas have a chemical base, with high material costs and generating secondary pollutants. The biological processes for the removal of H2S have become an effective and economical alternative to traditional gas treatment systems based on physicochemical techniques. Therefore, the aim of this work was to investigate the performance of a bench scale biofilter for the removal of H2S present in synthetic biogas. In addition, the concentrations of CO2 and CH4 in the effluent biogas were evaluated. The inoculum used in the experiment was composed of Acidithiobacillus thiooxidans fixed on a packing of wood chips. The synthetic biogas was supplied to the system with a composition of 60% CH4, 39 % CO2 and 1 % H2S. The determination of the concentration of hydrogen sulfide was performed by voltammetry and the concentrations of CH4 and CO2 by gas chromatography. The biofilter operated continuously for 37 days with an average removal efficiency of H2S of 75 ± 13 % and maximum of 97%. The elimination capacity of the system reached an average of 130 ± 23 g.m-3.h-1 and a maximum of 169 g.m3.h-1. The biofiltration system showed an average reduction of only 6 % in the CH4 content of the biogas. Thus, besides efficiently being used for the removal of H2S, the system was able to maintain the biogas energy value. / O biogás é um produto final da degradação anaeróbica de substâncias orgânicas e tem seu uso limitado na geração de energia devido, principalmente, à presença do sulfeto de hidrogênio (H2S). Atualmente, a maior parte das técnicas empregadas na remoção de H2S do biogás tem base química, possuindo altos custos materiais e gerando poluentes secundários. Os processos de remoção biológica de H2S têm se tornado uma alternativa eficaz e econômica para os sistemas tradicionais de tratamento de gás baseados em técnicas físico-químicas. Dessa forma, objetivou-se com este trabalho investigar o desempenho de um biofiltro em escala laboratorial na remoção do H2S presente em biogás sintético. Além disso, avaliaram-se as concentrações de CH4 e CO2 no biogás efluente. O inóculo utilizado no experimento foi composto de Acidithiobacillus thiooxidans fixado em um meio suporte de cavacos de madeira. O biogás sintético fornecido ao sistema possuiu composição de 60% de CH4, 39% de CO2 e 1% de H2S. A determinação da concentração de sulfeto de hidrogênio foi realizada através de voltametria e as concentrações de CH4 e CO2 por cromatografia gasosa. O biofiltro operou continuamente durante 37 dias, apresentando uma eficiência média na remoção de H2S de 75 ± 13% e máxima de 97%. A capacidade de eliminação do sistema atingiu um valor médio de 130±23 g.m-3.h-1 e máximo de 169 g.m-3.h-1. O sistema de biofiltração apresentou uma redução média de apenas 6% no teor de CH4 do biogás. Sendo assim, além de poder ser eficientemente utilizado para a eliminação do H2S, o sistema foi capaz de manter o valor energético do biogás.
4

Remoção de 'H IND. 2' 'S' de ar por Thiobacillus denitrificans utilizando biofiltro percolador

Solcia, Renata de Bello [UNESP] 01 February 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:05Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-02-01Bitstream added on 2014-06-13T20:59:06Z : No. of bitstreams: 1 solcia_rb_me_araiq.pdf: 1432643 bytes, checksum: 92164fbf9e408534eafc69bd3af54fbe (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste trabalho foram realizados ensaios para o estudo da viabilidade da conversão de lavadores químicos (tecnologia química muito utilizada para a remoção de H2S) em biofiltros percoladores para a remoção de H2S. Foi investigado o efeito inibitório da concentração de sulfato no meio de recirculação de nutrientes, o efeito do pH, da vazão de recirculação de nutrientes, da concentração de alimentação de H2S na corrente gasosa e do tempo de residência na eficiência de remoção de H2S em dois biofiltros percoladores, um recheado com espuma de poro aberto de poliuretano e o outro com anéis de Pall de polipropileno. Durante a etapa de imobilização dos micro-organismos foi observado, experimentalmente, que o anel de Pall de polipropileno não é um bom suporte para a imobilização de Thiobacillus denitrificans e, portanto, no caso da conversão de um lavador químico constituído por um leito de recheio de anéis de Pall em um biofiltro percolador, seria apropriada a substituição deste suporte por espuma de poro aberto de poliuretano, por exemplo, que demonstrou ser um bom suporte para a formação do biofilme. Durante o estudo do efeito do pH observou-se que o aumento de pH aumenta a porcentagem de remoção de H2S, sendo que nas condições utilizadas, o intervalo de pH ótimo ficou entre 7,6 – 8,5. O efeito inibitório da concentração de sulfato foi observado a partir de 16,5 g L-1 no biofiltro de espuma de poro aberto de poliuretano e de 13,0 g L-1 no biofiltro de anéis de Pall de polipropileno. Os efeitos da vazão de recirculação de nutrientes e do tempo de residência do gás foram mais evidentes no biofitro de anéis de Pall comparado a espuma de poro aberto, devido, provavelmente, às características do suporte. No biofiltro de espuma de poro aberto, a diminuição do tempo de residência afetou a... / In this work experiments were carried out in order to study the viability of conversion of chemical scrubbers (current technology) to biotrickling filter for removing H2S. Many parameters were investigated, such as, the inhibitory effect of sulfate concentration in the nutrient recirculation, the effect of the pH, the flow rate of recirculating nutrient, the inlet H2S concentration and the gas stream residence time in the H2S removal capacity in two biotrickling filter. One of them was packaged with open pore polyurethane foam and other with polypropylene Pall rings. During and after the immobilization stage it was observed, experimentally, that polypropylene Pall rings is not a good support for immobilizing Thiobacillus denitrificans. Thus, in the case of a chemical packaged scrubber conversion using such support in a biotrickling filter, it would be appropriate to replace it by open pore polyurethane foam, for instance, which demonstrated to be a better support to the biofilm to establish. It was shown that increasing the pH an increase in the H2S removal was detected. In this experimental work conditions, the optimum pH range was from 7.6 to 8.5. The inhibitory effect of the sulfate concentration was observed from 16.5 g L-1 in the open pore polyurethane foam biofilter and 13.0 g L-1 in the polypropylene Pall rings biofilter. The effects of the flow rate of the recirculating nutrient and the gas residence time were more evident in the Pall ring biofilter when compared with the open pore foam, probably due to the support characteristics. In the open pore foam biofilter, decreasing the residence time the H2S removal percentage was affected only for less than 9 s, whereas in the Pall rings biofilter, before 33 s. In both biofilters as lower the residence time, lower the H2S removal percentage. In the open pore polyurethane foam... (Complete abstract click electronic access below)
5

Avaliação da utilização de diferentes materiais suporte na biofiltração de sulfeto de hidrogênio / Utilization of different packing materials in the hydrogen sulfide biofiltration

Jorge Luis Rodrigues Pantoja Filho 25 April 2008 (has links)
O sulfeto de hidrogênio é um gás que pode causar os mais diversos danos se lançado ao meio ambiente devido, principalmente, à sua elevada toxicidade, corrosividade, odores indesejáveis e alta demanda de oxigênio. Atualmente existem diferentes processos físico-químicos estabelecidos para o tratamento desse composto, entretanto são consideradas técnicas onerosas do ponto de vista econômico e ambiental. Os processos biológicos constituem-se como uma alternativa bastante interessante quando comparados aos processos físico-químicos, sendo que a biofiltração é o processo mais amplamente utilizado. Neste trabalho, foram avaliados três tipos diferentes de materiais suporte, sendo um sintético - espuma de poliuretano - e dois orgânicos - fibra de côco e bagaço de cana -, para a biofiltração de uma mistura gasosa contendo \'H IND.2\'S\'. Como inóculo, optou-se pela utilização de cultura mista originária de duas fontes: a) unidade de biofiltro aerado submerso pertencente ao Serviço Autônomo de Água e Esgoto da Cidade de São Carlos, b) unidade de lodos ativados pertencente a São Carlos S/A - Indústria de Papel e Celulose. A adaptação do inóculo foi realizada em meio nutriente específico. Foi observado um período de partida de somente 2 dias nos três sistemas. Com o intuito de avaliar o impacto do aumento progressivo das taxas de carregamento mássico no desempenho dos três biofiltros, os mesmos foram submetidos a taxas de 19, 32, 54 e 70 g/m³.h (concentrações afluentes médias de 184, 328, 526 e 644 ppm para tempo de retenção do gás de, aproximadamente, 50 segundos). As eficiências remoção média em todos os sistemas mantiveram-se sempre acima dos 99,3%. A capacidade eliminação máxima alcançada pelos biofiltros oscilou entre 74 e 80 g/m³.h. As perdas de carga verificadas no ensaio hidrodinâmico foram baixas, variando entre 0,59.\'10 POT.-2\' a 0,68 \'10 POT.-2\' mca, para a velocidade superficial utilizada durante o estudo. O modelo matemático empregado na previsão do desempenho dos sistemas ajustou-se bem aos dados experimentais. Portanto, pode-se concluir que os materiais suportes testados são adequados para a biofiltração de sulfeto de hidrogênio. / Hydrogen sulfide is a gas which has high restrictions regarding to its disposal in the environment, mainly, because of its high toxicity, malodors, high oxygen demand, etc. Currently, there are many different physical-chemical processes established in order to treat this compound, nevertheless they are considered expensive techniques by the point of economical and environmental views. Biological processes are very interesting alternatives when they are compared to the physical-chemical ones, and biofiltration is the most used process. In this work, three different materials as support media were evaluated, - a synthetic one - represented by the polyurethane foam, - two organic ones - represented by coconut fiber and sugar bagasse -, for a biofiltration of a gaseous mixture containing \'H IND.2\'S\'. Microorganisms were obtained from two sources: a) submerged aerated biofilter unit, b) activated sludge unit. Inoculum\'s adaptation was realized in specific nutrient media. It was observed a 2 days start-up period in the three systems. In order to evaluate some impact caused by the progressive increasing of mass loading rate on the biofilters performance, were applied rates of 19, 32, 54 e 70 g/m³.h (average influent concentrations of 184, 328, 526 e 644 ppm to the empty bed retention time of, approximately, 50 seconds). Average removal efficiencies in the systems were always above 99,3%. Maximum elimination capacities reached by the biofilters were in the range of 74 e 80 g/m³.h. Loss pressure verified by the hands of hydrodynamic essays varied between 0,59.\'10 POT.-2\' a 0,68.\'10 POT.-2\' mca, to a superficial velocity utilized during the work. Mathematical model used to predict the performance of the systems fitted reasonably the experimental data. Then, it can be concluded that the three packing materials are appropriated for the hydrogen sulfide biofiltration.
6

Desempenho de filtro biológico na depuração e desodorização de emissões de sulfeto de hidrogênio / Biofilter efficiencies in the purification and deodorization of hydrogen sulfide emissions

Rocha, Alexandre Prado 17 April 2007 (has links)
Os efluentes gasosos industriais têm sido tradicionalmente tratados por processos físico-químicos, como lavadores, adsorção, condensação e oxidação. Embora essas técnicas tenham altas eficiências, a necessidade de adição de produtos químicos e a substituição do adsorvente resulta em custo de operação relativamente alto quando comparados com técnicas de tratamento biológico. O objetivo deste trabalho foi: aprimorar uma unidade experimental de biofiltração para depuração de uma corrente gasosa contendo \'H IND.2\'S\' utilizando como material suporte a espuma de poliuretano, analisar a fluidodinâmica do leito através de ensaios de perda de carga em função da vazão de ar e da umidade do leito e analisar o desempenho do biofiltro na depuração do \'H IND.2\'S\' com o aumento progressivo da concentração de entrada. O biofiltro foi construído com uma coluna de acrílico, dividida em 3 módulos, 2 com 13 cm de altura e um central com 50 cm, totalizando uma altura do leito de 76 cm e o diâmetro interno era de 5,2 cm. Nas extremidades superiores e inferiores do biofiltro foram acoplados módulos para a distribuição e captação da corrente gasosa e também para a recirculação da fase líquida. O inóculo utilizado foi lodo de uma unidade de lodos ativados, que trabalha como pós-tratamento de um reator UASB tratando esgotos domésticos. A adaptação do inóculo foi realizada por 7 dias com tiossulfato e 7 dias com o \'H IND.2\'S\'. As concentrações médias de sulfeto estudadas foram subdivididas em sete fases com concentrações médias de 141, 271, 514, 532, 581, 878 e 1303 ppm. A vazão utilizada foi de 100 L/h resultando em um tempo de detenção de aproximadamente 58 segundos. As perdas de carga obtidas no sistema foram inferiores a 0,8.\'10 POT.-2\' mca. A espuma de poliuretano se apresentou um bom meio suporte para a fixação dos microrganismos. O lodo ativado se apresentou um bom inóculo para o tratamento de \'H IND.2\'S\' por necessitar de um curto período de tempo para sua adaptação. A eficiência média do biofiltro se manteve acima dos 96%. A umidade do leito se manteve acima de 92%, atingindo uma capacidade de eliminação máxima (ECmáx) de aproximadamente 155 g/\'M POT.3\'.h e uma capacidade de eliminação ótima (ECótimo) de aproximadamente 139 g/\'M POT.3\'.h. O principal produto da degradação do \'H IND.2\'S\' encontrado foi o enxofre elementar. / Traditionally the industrial waste gases have been treated by physical-chemical processes, such as scrubbers, absorption, condensation and oxidation. Although these techniques presented great efficiency, the need to add chemical products and the replacement of adsorbent results in relatively high operational costs compared to biological treatment techniques. The objective of this study is to improve an experimental biofiltration unit to remove air steam containing \'H IND.2\'S\', using polyurethane foam as filter bed, to analyze the bed dynamic flow through pressure drop and the bed moisture, and to analyze the biofilter behavior during the \'H IND.2\'S\' depuration with the progressive increase of input concentration. The bio-filter has an acrylic column, divided into 3 parts, from which two are 13 cm high and the central one is 50 cm high, adding up to a 76 cm high column with an inner diameter of 5.2 cm. Modules were attached on the top and bottom biofilter extremities to distribute and collect the air stream and also to recirculate the liquid phase. The inoculum used was a sludge from a activated sludge unit, which works as post-treatment for domestic sewer treated by a UASB reactor. The inoculum acclimatizing was done for 7 days with thiosulphate and 7 days with \'H IND.2\'S\'. The studied measured hydrogen sulphide concentrations were divided into seven average concentration levels, which are 141, 271, 514, 532, 581, 878 e 1303 ppm. The used ratio was 100 L/h resulting in hydraulic retention time of approximately 58 seconds. The head losses obtained in the system were below 0.8 \'10 POT.-2\' mca. The polyurethane foam presented to be a good support manner to the microorganisms attach. The activated sludge presented to be a good inoculum for the treatment of \'H IND.2\'S\' because it required a short time to adapt. The average efficiency of the biofilter kept above 96% and the bed humidity above 92%, reaching the maximum elimination capacity (ECmáx) of approximately 155 g/\'M POT.3\'.h and a optimum elimination capacity of approximately 139 g/\'M POT.3\'.h. The main \'H IND.2\'S\' degradation product found was the elemental sulfur.
7

Desempenho de filtro biológico na depuração e desodorização de emissões de sulfeto de hidrogênio / Biofilter efficiencies in the purification and deodorization of hydrogen sulfide emissions

Alexandre Prado Rocha 17 April 2007 (has links)
Os efluentes gasosos industriais têm sido tradicionalmente tratados por processos físico-químicos, como lavadores, adsorção, condensação e oxidação. Embora essas técnicas tenham altas eficiências, a necessidade de adição de produtos químicos e a substituição do adsorvente resulta em custo de operação relativamente alto quando comparados com técnicas de tratamento biológico. O objetivo deste trabalho foi: aprimorar uma unidade experimental de biofiltração para depuração de uma corrente gasosa contendo \'H IND.2\'S\' utilizando como material suporte a espuma de poliuretano, analisar a fluidodinâmica do leito através de ensaios de perda de carga em função da vazão de ar e da umidade do leito e analisar o desempenho do biofiltro na depuração do \'H IND.2\'S\' com o aumento progressivo da concentração de entrada. O biofiltro foi construído com uma coluna de acrílico, dividida em 3 módulos, 2 com 13 cm de altura e um central com 50 cm, totalizando uma altura do leito de 76 cm e o diâmetro interno era de 5,2 cm. Nas extremidades superiores e inferiores do biofiltro foram acoplados módulos para a distribuição e captação da corrente gasosa e também para a recirculação da fase líquida. O inóculo utilizado foi lodo de uma unidade de lodos ativados, que trabalha como pós-tratamento de um reator UASB tratando esgotos domésticos. A adaptação do inóculo foi realizada por 7 dias com tiossulfato e 7 dias com o \'H IND.2\'S\'. As concentrações médias de sulfeto estudadas foram subdivididas em sete fases com concentrações médias de 141, 271, 514, 532, 581, 878 e 1303 ppm. A vazão utilizada foi de 100 L/h resultando em um tempo de detenção de aproximadamente 58 segundos. As perdas de carga obtidas no sistema foram inferiores a 0,8.\'10 POT.-2\' mca. A espuma de poliuretano se apresentou um bom meio suporte para a fixação dos microrganismos. O lodo ativado se apresentou um bom inóculo para o tratamento de \'H IND.2\'S\' por necessitar de um curto período de tempo para sua adaptação. A eficiência média do biofiltro se manteve acima dos 96%. A umidade do leito se manteve acima de 92%, atingindo uma capacidade de eliminação máxima (ECmáx) de aproximadamente 155 g/\'M POT.3\'.h e uma capacidade de eliminação ótima (ECótimo) de aproximadamente 139 g/\'M POT.3\'.h. O principal produto da degradação do \'H IND.2\'S\' encontrado foi o enxofre elementar. / Traditionally the industrial waste gases have been treated by physical-chemical processes, such as scrubbers, absorption, condensation and oxidation. Although these techniques presented great efficiency, the need to add chemical products and the replacement of adsorbent results in relatively high operational costs compared to biological treatment techniques. The objective of this study is to improve an experimental biofiltration unit to remove air steam containing \'H IND.2\'S\', using polyurethane foam as filter bed, to analyze the bed dynamic flow through pressure drop and the bed moisture, and to analyze the biofilter behavior during the \'H IND.2\'S\' depuration with the progressive increase of input concentration. The bio-filter has an acrylic column, divided into 3 parts, from which two are 13 cm high and the central one is 50 cm high, adding up to a 76 cm high column with an inner diameter of 5.2 cm. Modules were attached on the top and bottom biofilter extremities to distribute and collect the air stream and also to recirculate the liquid phase. The inoculum used was a sludge from a activated sludge unit, which works as post-treatment for domestic sewer treated by a UASB reactor. The inoculum acclimatizing was done for 7 days with thiosulphate and 7 days with \'H IND.2\'S\'. The studied measured hydrogen sulphide concentrations were divided into seven average concentration levels, which are 141, 271, 514, 532, 581, 878 e 1303 ppm. The used ratio was 100 L/h resulting in hydraulic retention time of approximately 58 seconds. The head losses obtained in the system were below 0.8 \'10 POT.-2\' mca. The polyurethane foam presented to be a good support manner to the microorganisms attach. The activated sludge presented to be a good inoculum for the treatment of \'H IND.2\'S\' because it required a short time to adapt. The average efficiency of the biofilter kept above 96% and the bed humidity above 92%, reaching the maximum elimination capacity (ECmáx) of approximately 155 g/\'M POT.3\'.h and a optimum elimination capacity of approximately 139 g/\'M POT.3\'.h. The main \'H IND.2\'S\' degradation product found was the elemental sulfur.
8

Biofiltração de compostos orgânicos voláteis e gás sulfídrico em estações de despejos industriais de processamento de hidrocarbonetos. / Biofiltration of volatile organic compounds and hydrogen sulphide in an wastewater treatment plant of processing oil.

Beatrix Nery Villa Martignoni 09 March 2007 (has links)
Neste trabalho foi estudado o tratamento simultâneo por biofiltração de emissões de compostos orgânicos voláteis, COV e gás sulfídrico, H2S, em estações de tratamento de despejos industriais, de refinaria de petróleo, ETDI. A biofiltração dos gases emanados da EDTI mostrou ser uma técnica de alta eficiência, atingindo valores de 95 a 99 % para tratamento simultâneo de COV e H2S em concentrações de 1000 e 100 ppmv, respectivamente. Foram realizados testes em 95 dias consecutivos de operação, em uma planta piloto instalada na Superintendência da Industrialização do Xisto, SIX, em São Mateus do Sul, Paraná, de março a agosto de 2006. O biofiltro foi do tipo fluxo ascendente, com 3,77 m3 de leito orgânico, composto de turfa, carvão ativado, lascas de madeira, serragem brita fina além de outros componentes menores. Foi realizada inoculação biológica com lodo filtrado de estação de tratamento de esgoto sanitário. As vazões de gás aplicadas variaram de 85 a 407 m3/h, resultando em taxas de carga de massa de 11,86 a 193,03 g de COV/h.m3 de leito e tempos de residência de 24 segundos a 6,5 minutos, com tempo ótimo de 1,6 minutos. A capacidade máxima de remoção do sistema encontrada, nas condições testadas, foi de 15 g de COV/h. m3, compatível com os valores encontrados na literatura para depuração biológica de COV na escala praticada. Também foi verificada a redução de componentes específicos de BTX, demonstrando boa degradabilidade dos compostos orgânicos. Finalmente o biofiltro demonstrou boa robustez biológica diante dos desvios operacionais intencionalmente provocados, tais como falta de umidade do leito, baixa temperatura, alta vazão, falta de carga de COV e baixo pH do leito. Depois de retomada a condição de operação estável, a biofiltração rapidamente atingiu o estado de equilíbrio, assegurando o uso eficiente e confiável da técnica no tratamento de gases de EDTI na indústria do hidrocarbonetos ou em refinarias de petróleo. / In this project the biofiltration technique was applied as air pollution control technology to treat simultaneously emissions containing volatile organic compounds, VOC and hydrogen sulfide, H2S, in hydrocarbon processing industries and oil refinery Waste Water Treatment Plant, WWTP. The technique demonstrated high biological efficiency up to 95 and 100 % of simultaneous biofiltration of VOC and H2S, with inicial concentration of 1000 and 100 ppmv, respectively. Tests were conducted at UN-SIX/ Petrobras Oil Shale Processing Unit facilities through 95 consecutives days, from March to August 2006. The chosen reactor model was an up stream system, pilot plant scale with volume of 3.77 m3 of an organic compost media made out a blend of peat, rotten wood chips, activated carbon, lime, among other minor components. The biological inoculation was done with sanitary sludge from WWTP. The pilot plant capacity was able to treat from 85 to 480 m3/h of WWTP off-gas, resulting COV application rate from 11.86 to 193.03 g VOC/ h. m3 of media, and residence time from 24 sec to 6.5 minutes, with optimum value at 1.6 minutes. The system maximum elimination rate was about 15 g VOC/h. m3, value comparable to ones presented in open literature. The specific BTX compounds depuration was observed, demonstrating relevant media specificity to treat organic compounds. Finally the biofiltration systems demonstrated good biological toughness considering the operational provoked upsets, as lack of media bed humidity, low biofiltration temperature, high flow rate, lack of VOC flow and acid pH. After normal operational conditions were retaken all process characteristics and efficiency [was] reached the correspondent values, showing reliable and efficient use of the technique to treat off gases in WWTP of hydrocarbon processing industries and Oil Refineries.
9

Biofiltração de compostos orgânicos voláteis e gás sulfídrico em estações de despejos industriais de processamento de hidrocarbonetos. / Biofiltration of volatile organic compounds and hydrogen sulphide in an wastewater treatment plant of processing oil.

Beatrix Nery Villa Martignoni 09 March 2007 (has links)
Neste trabalho foi estudado o tratamento simultâneo por biofiltração de emissões de compostos orgânicos voláteis, COV e gás sulfídrico, H2S, em estações de tratamento de despejos industriais, de refinaria de petróleo, ETDI. A biofiltração dos gases emanados da EDTI mostrou ser uma técnica de alta eficiência, atingindo valores de 95 a 99 % para tratamento simultâneo de COV e H2S em concentrações de 1000 e 100 ppmv, respectivamente. Foram realizados testes em 95 dias consecutivos de operação, em uma planta piloto instalada na Superintendência da Industrialização do Xisto, SIX, em São Mateus do Sul, Paraná, de março a agosto de 2006. O biofiltro foi do tipo fluxo ascendente, com 3,77 m3 de leito orgânico, composto de turfa, carvão ativado, lascas de madeira, serragem brita fina além de outros componentes menores. Foi realizada inoculação biológica com lodo filtrado de estação de tratamento de esgoto sanitário. As vazões de gás aplicadas variaram de 85 a 407 m3/h, resultando em taxas de carga de massa de 11,86 a 193,03 g de COV/h.m3 de leito e tempos de residência de 24 segundos a 6,5 minutos, com tempo ótimo de 1,6 minutos. A capacidade máxima de remoção do sistema encontrada, nas condições testadas, foi de 15 g de COV/h. m3, compatível com os valores encontrados na literatura para depuração biológica de COV na escala praticada. Também foi verificada a redução de componentes específicos de BTX, demonstrando boa degradabilidade dos compostos orgânicos. Finalmente o biofiltro demonstrou boa robustez biológica diante dos desvios operacionais intencionalmente provocados, tais como falta de umidade do leito, baixa temperatura, alta vazão, falta de carga de COV e baixo pH do leito. Depois de retomada a condição de operação estável, a biofiltração rapidamente atingiu o estado de equilíbrio, assegurando o uso eficiente e confiável da técnica no tratamento de gases de EDTI na indústria do hidrocarbonetos ou em refinarias de petróleo. / In this project the biofiltration technique was applied as air pollution control technology to treat simultaneously emissions containing volatile organic compounds, VOC and hydrogen sulfide, H2S, in hydrocarbon processing industries and oil refinery Waste Water Treatment Plant, WWTP. The technique demonstrated high biological efficiency up to 95 and 100 % of simultaneous biofiltration of VOC and H2S, with inicial concentration of 1000 and 100 ppmv, respectively. Tests were conducted at UN-SIX/ Petrobras Oil Shale Processing Unit facilities through 95 consecutives days, from March to August 2006. The chosen reactor model was an up stream system, pilot plant scale with volume of 3.77 m3 of an organic compost media made out a blend of peat, rotten wood chips, activated carbon, lime, among other minor components. The biological inoculation was done with sanitary sludge from WWTP. The pilot plant capacity was able to treat from 85 to 480 m3/h of WWTP off-gas, resulting COV application rate from 11.86 to 193.03 g VOC/ h. m3 of media, and residence time from 24 sec to 6.5 minutes, with optimum value at 1.6 minutes. The system maximum elimination rate was about 15 g VOC/h. m3, value comparable to ones presented in open literature. The specific BTX compounds depuration was observed, demonstrating relevant media specificity to treat organic compounds. Finally the biofiltration systems demonstrated good biological toughness considering the operational provoked upsets, as lack of media bed humidity, low biofiltration temperature, high flow rate, lack of VOC flow and acid pH. After normal operational conditions were retaken all process characteristics and efficiency [was] reached the correspondent values, showing reliable and efficient use of the technique to treat off gases in WWTP of hydrocarbon processing industries and Oil Refineries.

Page generated in 0.0384 seconds