• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Sustainable Carbon Sequestration: Increasing CO2-Storage Efficiency through a CO2-Brine Displacement Approach

Akinnikawe, Oyewande 2012 August 1900 (has links)
CO2 sequestration is one of the proposed methods for reducing anthropogenic CO2 emissions to the atmosphere and therefore mitigating global climate change. Few studies on storing CO2 in an aquifer have been conducted on a regional scale. This study offers a conceptual approach to increasing the storage efficiency of CO2 injection in saline formations and investigates what an actual CO2 storage project might entail using field data for the Woodbine aquifer in East Texas. The study considers three aquifer management strategies for injecting CO2 emissions from nearby coal-fired power plants into the Woodbine aquifer. The aquifer management strategies studied are bulk CO2 injection, and two CO2-brine displacement strategies. A conceptual model performed with homogeneous and average reservoir properties reveals that bulk injection of CO2 pressurizes the aquifer, has a storage efficiency of 0.46% and can only last for 20 years without risk of fracturing the CO2 injection wells. The CO2-brine displacement strategy can continue injecting CO2 for as many as 240 years until CO2 begins to break through in the production wells. This offers 12 times greater CO2 storage efficiency than the bulk injection strategy. A full field simulation with a geological model based on existing aquifer data validates the storage capacity claims made by the conceptual model. A key feature in the geological model is the Mexia-Talco fault system that serves as a likely boundary between the saline aquifer region suitable for CO2 storage and an updip fresh water region. Simulation results show that CO2 does not leak into the fresh water region of the iv aquifer after 1000 years of monitoring if the faults have zero transmissibility, but a negligible volume of brine eventually gets through the mostly sealing fault system as pressure across the faults slowly equilibrates during the monitoring period. However, for fault transmissibilities of 0.1 and 1, both brine and CO2 leak into the fresh water aquifer in increasing amounts for both bulk injection and CO2-brine displacement strategies. In addition, brine production wells draw some fresh water into the saline aquifer if the Mexia-Talco fault system is not sealing. A CO2 storage project in the Woodbine aquifer would impact as many as 15 counties with high-pressure CO2 pipelines stretching as long as 875 km from the CO2 source to the injection site. The required percentage of power plant energy capacity was 7.43% for bulk injection, 7.9% for the external brine disposal case, and 10.2% for the internal saturated brine injection case. The estimated total cost was $0.00132–$0.00146/kWh for the bulk injection, $0.00191–$0.00211/kWh for the external brine disposal case, and $0.0019–$0.00209/kWh for the internal saturated brine injection case.
2

Wettability study through x-ray micro-ct pore space imaging in eor applied to lsb recovery process / Etude de la mouillabilité par imagerie micro-ct de l’espace inter poral appliquée au procédé de récupération d’injection d’eau douce

Nazarova Cherriere, Marfa 30 October 2014 (has links)
La thèse a pour but d’étudier les effets de changements de mouillabilité de roches dans des conditions d’injections d’eau douce en tant que méthode de récupération d’hydrocarbures. Afin d’identifier le ou les mécanismes à l’origine du gain additionnel de récupération nous avons utilisé un microtomographe RX. Nous avons ainsi imagé les états de saturations finales d’un milieu poreux rempli de saumures et d’huiles. Une fois le drainage primaire réalisé nous avons effectué deux phases d’imbibitions : avec une saumure (récupération secondaire) puis une imbibition d’eau douce (récupération tertiaire). L’analyse de la mouillabilité à l’échelle du pore a permis de mettre en évidence l’effet de la température et de la salinité sur la mouillabilité. Nous avons montré que les changements de mouillages des roches n’étaient pas occasionnées par la seule expansion de la couche électrique en revanche des changements de mouillabilité ont été montrés. Ces changements s’expliquant par des transitions de mouillages de second ordre observées non seulement pour des gouttes d’huiles sur de l’eau mais également sur un substrat en verre. Au final, la mouillabilité en milieux poreux doit être mise en évidence à une échelle sous-Micrométrique ce qui est relativement nouveau dans le domaine pétrolier. / The aim of the thesis is to study rock wettability change effects caused by Low Salinity brine injection as tertiary recovery method. To identify the underlying mechanism or mechanisms of additional oil recovery X-Ray imaging technology was applied. We have also imaged the end-Point saturations of filled by brine and water core samples. Once the primary drainage is realized we carried out two phases imbibitions: with high salinity brine (waterflooding) and with low salinity brine (tertiary recovery mode). The wettability analysis at pore scale permitted to put in evidence the thermal and saline effects playing a decisive role in rock wettability. We have showed wettability changes are not caused by only electrical double layer expansion, however wettability changes was shown. These changes are explained by wettability transition of second order and observed not only for oil droplet on brine, but also for oil deposited on glass substrate. Finally, the pore space wettability needs to be evidenced at sub-Micrometric scale that is new for the petroleum domain.

Page generated in 0.2396 seconds