Spelling suggestions: "subject:"valor solar""
1 |
Analise da refletancia de cores de tintas atraves da tecnica espectrofotometricaCastro, Adriana Petito de Almeida Silva 15 April 2002 (has links)
Orientadores : Lucila Chebel Labaki, Rosana Maria Caram de Assis / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-01T23:58:04Z (GMT). No. of bitstreams: 1
Castro_AdrianaPetitodeAlmeidaSilva_M.pdf: 3579869 bytes, checksum: 2e610dbb8a4a747d7ab302f737531226 (MD5)
Previous issue date: 2002 / Resumo: Neste trabalho estuda-se a atenuação do ganho de calor solar através da escolha adequada da cor externa, como princípio da concepção bioclimática. É proposta uma metodologia para medições de refletância de cores, utilizando a análise por espectrofotometria. O método fornece não apenas a refletância total como também porcentagens de reflexão ao longo do espectro. Utiliza-se o acessório chamado esfera integradora, que permite a distribuição difusa da luz. Amostras de tintas de diferentes cores são analisadas em função da refletância à radiação solar. São feitas análises em 15 pastilhas pintadas com várias cores de tintas, bem como em 22 amostras retiradas de catálogo de fabricante. Através dos resultados obtidos, elabora-se uma comparação entre as refletâncias obtidas para as pastilhas e para o catálogo, bem como uma relação das cores de menor contribuição no ganho de calor. É possível atualizar dados sobre refletância de cores, e complementar informações técnicas pouco disponíveis no mercado / Abstract: In this work, the reduction of heat gain through the choice of appropriate external color is studied as a principle of bioclimatic conception. A methodology is proposed to obtain data of color reflectance, using spectrophotometric technique. The method provides not only the total reflectance, but also the percentage of reflection along the spectrum. An accessory named integrating sphere is used to allow diffuse distribution of the light. Samples of paints of different colors are ana1yzed in function of reflectance to solar radiation. Analysis of 15 tablets painted with several colors of paints, as well as in 22 samples obtained from manufacturer catalogue are performed. Through the results, a comparison between the achieved reflectance to pastilles and to the catalogue is elaborated, as well as a relation of colors that give less contribution to heat gain. With these results, it is possible to update data about color reflectance, and add technical information not available in the market / Mestrado / Edificações / Mestre em Engenharia Civil
|
2 |
A geografia do risco e da vulnerabilidade ao calor em espaços urbanos da zona tropical : o caso Cuiabá/MT /Teobaldo Neto, Aristóteles. January 2019 (has links)
Orientador: Margarete Cristiane de Costa Trindade Amorim / Banca: João Lima Sant'Anna Neto / Banca: João Osvaldo Rodrigues Nunes / Banca: José Carlos Ugeda Júnior / Banca: Lúcio José Sobral da Cunha / Resumo: A sociedade que vive nos espaços urbanos da zona intertropical do Planeta Terra sofre com a maior propensão à exposição a elevadas temperaturas. Isso constitui um risco, o qual pode variar da perda de qualidade de vida a agravos na saúde mais sérios. A análise geográfica de qualquer fenômeno com origem natural adquire uma complexidade específica na zona tropical, tendo em vista ser ocupada por países marcados por profundas desigualdades sociais, fator que implica amenização ou agravamento do risco em função do grupo social. Isso posto, foi definido como principal objetivo desta tese, investigar a dimensão do risco em função da exposição ao calor em áreas urbanas tropicais, na estação mais quente do ano, tendo como estudo de caso a área urbana de Cuiabá MT, uma das mais quentes do Brasil. Para tanto foi necessário: identificar e explicar os processos produtores dos diferentes níveis de riscos e vulnerabilidades no espaço urbano; analisar o perigo que representa a exposição ao calor, através do estudo da Ilha de Calor Urbana (ICU) e do microclima domiciliar; elaborar um índice de vulnerabilidade social para áreas urbanas; analisar e explicar de que forma a vulnerabilidade social condiciona (aumenta/reduz) o perigo em função da exposição ao calor. A metodologia baseou-se na aplicação de técnicas estatísticas, geoprocessamento, trabalhos de campo e uso de banco de dados de fontes primária e secundária, com destaque para o uso de dados do Censo Demográfico 2010 (IBGE) para a elabo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The society that lives in urban spaces in the Earth's tropical zone is subject to a greater propensity of exposure to high temperatures. It constitutes a risk which may range from a reduction in the quality of life to more serious health issues. The geographic analysis of any phenomenon with natural origin embodies a specific complexity in the tropical zone as most countries in this zone are marked by deep social inequalities which imply easing or worsening of the risk according to the social group someone belongs to. Therefore, it has been established as the main goal of this thesis, to investigate the dimension of the risk according to the heat exposure in tropical urban areas during the warmest season of the year, with the urban area of Cuiabá (Mato Grosso), which is one of the warmest in Brazil, being the case study. To achieve such goal, it was necessary to: identify and explain the processes that produce the different levels of risk and vulnerability in the urban space; analyse the danger represented by heat exposure through the study of the Urban Heat Island (UHI) and the household microclimate; elaborate a social vulnerability index for the urban areas; analyse and explain how the social vulnerability constrains (increases/reduces) the danger according to heat exposure. The methodology was based on the application of statistical techniques, geoprocessing, field work and the use of first-source and second-source databases where the use of data from the 2010 Census (fro... (Complete abstract click electronic access below) / Resumen: La sociedad que vive en los espacios urbanos de la zona intertropical del Planeta Tierra sufre con mayor índice a la exposición a elevadas temperaturas. Esto constituye un riesgo, el cual puede variar desde la pérdida de calidad de vida a daños en la salud más serios. El análisis geográfico de cualquier fenómeno con origen natural adquiere una complejidad específica en la zona tropical, teniendo como tendencia ser ocupada por países con profundas desigualdades sociales, factor que implica reducción o agravamiento de riesgo de acuerdo con la posición social. Esto fue definido como el principal objetivo de esta tesis, investigar la dimensión del riesgo en función de la exposición al calor en áreas urbanas tropicales, en la estación más caliente del año, teniendo como estudio del caso un área urbana de Cuiabá MT, una de las más calientes de Brasil. Por lo que fue necesario: identificar y explicar los procesos productores de los diferentes niveles de riesgos y vulnerabilidad en el especio urbano, analizar el peligro que representa la exposición al calor, a través de estudio de la isla de calor urbano (ICU) y del microclima domiciliar; elaborar un índice de vulnerabilidad social condiciona (aumenta/reduce) el peligro en función de la exposición al calor. La metodología se basó en la aplicación de técnicas estadísticas, geoprocesamiento, trabajos de campo y uso de bancos de datos de fuentes primarias y secundarias, con énfasis para el uso de datos del censo demográfico 2010 (IBGE) ... (Resumen completo clicar acceso eletrônico abajo) / Doutor
|
3 |
Estudo da viabilidade de implantação de plantas para conversão de energia térmica do oceano (OTEC) no BrasilNeves, Marcus Godolphim de Castro [UNESP] 27 February 2015 (has links) (PDF)
Made available in DSpace on 2015-07-13T12:10:16Z (GMT). No. of bitstreams: 0
Previous issue date: 2015-02-27. Added 1 bitstream(s) on 2015-07-13T12:25:31Z : No. of bitstreams: 1
000836695.pdf: 1571978 bytes, checksum: 4e307c80099ecf2308070178e4aa39ab (MD5) / Atualmente, a busca por novas fontes de energias renováveis tem sido o motivo de pesquisas e investimentos, sendo que a possibilidade de exploração da energia dos oceanos pode ser uma interessante alternativa. Um desses processos é baseado na extração da energia térmica solar acumulada na superfície dos oceanos. Parte dessa energia pode ser transformada em eletricidade e em vários outros subprodutos por meio de um processo conhecido como Conversão da Energia Térmica dos Oceanos (OTEC), que utiliza a água fria obtida a partir de uma profundidade de 1.000 m. As usinas OTEC podem operar em sistemas térmicos aberto, fechado ou híbrido, sendo que, para operar de forma adequada, o local de instalação da usina OTEC deve ter águas com temperatura média da superfície maior que 24 °C. O Brasil possui várias regiões que atendem esta condição sendo, portanto, um dos países com boa capacidade de instalação de usina OTEC para ajudar a suprir sua demanda energética. Este trabalho apresenta o estudo de viabilidade termodinâmica, termoeconômica e econômica de instalação de uma usina OTEC no Brasil por meio de simulações numéricas de seis casos de ciclos fechados, sendo cinco deles com um estágio (três com coletores solares e dois sem); e um caso com dois estágios, sem coletor solar. Os resultados mostraram que a planta com dois estágios não se mostrou viável. No entanto, observou-se que uma usina com ciclo fechado, com um estágio, é capaz de produzir de 13 a 19 MW, dependendo do caso, com custo entre R$ 0,55 (com coletor) e R$ 0,65 (sem coletor) por kW. Esse valor é inferior ao custo da energia produzida por motores estacionários a Diesel, de modo que essa tecnologia pode ser uma alternativa viável e sustentável para substituição dessa forma de geração de eletricidade no nordeste do Brasil, sendo também capaz de produzir água dessalinizada e sal / The search for new sources of clean renewable energy has been the subject of current research and investment, and the possible exploration of oceanic processes may be an interesting alternative. One of these processes is based on extraction of the solar thermal energy accumulated in the ocean upper layer. A fraction of this energy can be converted into electricity and various byproducts by means of a conversion process known simply as Ocean Thermal Energy Conversion (OTEC), which uses the cold water gotten from a depth of 1,000 m. OTEC plants operate in three distinct thermal cycles: open, closed and hybrid. To operate in an adequate form, the local of installation of an OTEC plant must have the sea's average surface temperature greater than 24 oC. Brazil has several offshore regions with these conditions, being one of the countries with good capacity to install OTEC plants to help to supply the electrical and energy demands. This work presents the study of thermodymanic, thermoeconomic and economic feasibility to install an OTEC plant in Brazil through numerical simulation of six cases of closed thermal cycles of an OTEC plant, being five of them with one stage (three with and two without solar boosters); one case with two stages and none solar booster. The results have shown that the two-stage plant has not been feseable. However, the one-stage closed cycle plants are able to produce between 13 to 19 MW, depending on the case considered, with cost between R$ 0,55 (with solar booster) and R$ 0,65 (without solar booster) per kW. These values is lower than the energy cost produced by Diesel stationary engines, so that this technology may be a feseable and sustainable alternative to replace this kind of power generation in Brazilian Northeast region, being able to produce fresh water and salt too
|
4 |
Estudo da viabilidade de implantação de plantas para conversão de energia térmica do oceano (OTEC) no Brasil /Neves, Marcus Godolphim de Castro. January 2015 (has links)
Orientador: Ricardo Alan Verdú Ramos / Co-orientador: Cassio Roberto de Macedo Maia / Banca: Emanuel Rocha Woiski / Banca: Mauro Conti Pereira / Resumo: Atualmente, a busca por novas fontes de energias renováveis tem sido o motivo de pesquisas e investimentos, sendo que a possibilidade de exploração da energia dos oceanos pode ser uma interessante alternativa. Um desses processos é baseado na extração da energia térmica solar acumulada na superfície dos oceanos. Parte dessa energia pode ser transformada em eletricidade e em vários outros subprodutos por meio de um processo conhecido como Conversão da Energia Térmica dos Oceanos (OTEC), que utiliza a água fria obtida a partir de uma profundidade de 1.000 m. As usinas OTEC podem operar em sistemas térmicos aberto, fechado ou híbrido, sendo que, para operar de forma adequada, o local de instalação da usina OTEC deve ter águas com temperatura média da superfície maior que 24 °C. O Brasil possui várias regiões que atendem esta condição sendo, portanto, um dos países com boa capacidade de instalação de usina OTEC para ajudar a suprir sua demanda energética. Este trabalho apresenta o estudo de viabilidade termodinâmica, termoeconômica e econômica de instalação de uma usina OTEC no Brasil por meio de simulações numéricas de seis casos de ciclos fechados, sendo cinco deles com um estágio (três com coletores solares e dois sem); e um caso com dois estágios, sem coletor solar. Os resultados mostraram que a planta com dois estágios não se mostrou viável. No entanto, observou-se que uma usina com ciclo fechado, com um estágio, é capaz de produzir de 13 a 19 MW, dependendo do caso, com custo entre R$ 0,55 (com coletor) e R$ 0,65 (sem coletor) por kW. Esse valor é inferior ao custo da energia produzida por motores estacionários a Diesel, de modo que essa tecnologia pode ser uma alternativa viável e sustentável para substituição dessa forma de geração de eletricidade no nordeste do Brasil, sendo também capaz de produzir água dessalinizada e sal / Abstract: The search for new sources of clean renewable energy has been the subject of current research and investment, and the possible exploration of oceanic processes may be an interesting alternative. One of these processes is based on extraction of the solar thermal energy accumulated in the ocean upper layer. A fraction of this energy can be converted into electricity and various byproducts by means of a conversion process known simply as Ocean Thermal Energy Conversion (OTEC), which uses the cold water gotten from a depth of 1,000 m. OTEC plants operate in three distinct thermal cycles: open, closed and hybrid. To operate in an adequate form, the local of installation of an OTEC plant must have the sea's average surface temperature greater than 24 oC. Brazil has several offshore regions with these conditions, being one of the countries with good capacity to install OTEC plants to help to supply the electrical and energy demands. This work presents the study of thermodymanic, thermoeconomic and economic feasibility to install an OTEC plant in Brazil through numerical simulation of six cases of closed thermal cycles of an OTEC plant, being five of them with one stage (three with and two without solar boosters); one case with two stages and none solar booster. The results have shown that the two-stage plant has not been feseable. However, the one-stage closed cycle plants are able to produce between 13 to 19 MW, depending on the case considered, with cost between R$ 0,55 (with solar booster) and R$ 0,65 (without solar booster) per kW. These values is lower than the energy cost produced by Diesel stationary engines, so that this technology may be a feseable and sustainable alternative to replace this kind of power generation in Brazilian Northeast region, being able to produce fresh water and salt too / Mestre
|
5 |
Desempenho termico de vidros utilizados na construção civil : estudo em celulas-teste / Thermal performace of glasses in building construction: study in test-cellsCastro, Adriana Petito de Almeida Silva 26 June 2006 (has links)
Orientador: Lucila Chebel Labaki / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-08T09:29:44Z (GMT). No. of bitstreams: 1
Castro_AdrianaPetitodeAlmeidaSilva_D.pdf: 2534532 bytes, checksum: 4ea70ab9e519a13a5ddf61c29646f7b7 (MD5)
Previous issue date: 2006 / Resumo: O desempenho térmico de uma edificação depende de fatores como implantação, orientação, materiais e componentes construtivos, que devem ser adequadamente definidos para diferentes condições climáticas. O edifício atua como mecanismo de controle das variáveis do clima, através de sua envoltória (paredes, piso, cobertura e aberturas) e dos elementos do entorno, e deve ser projetado de modo a proporcionar conforto e eficiência energética. Entre os componentes da construção, os vidros funcionam como um dos elementos de maior potencialidade de aquecimento interno. Devido à sua transparência à radiação solar, possibilitam facilmente o ingresso de grande parte dessa energia no ambiente. No presente rabalho estudou-se o comportamento de superfícies transparentes em fachadas, em situação real, através de medições em seis células-teste, de dimensões 2,00 x 2,50m. Analisou-se in loco o comportamento térmico de vidros, comercialmente disponíveis no mercado, cuja caracterização, do ponto de vista da transmissão espectral, já era conhecida através de técnica espectrofotométrica. Foram selecionados 14 tipos de vidros: cinco planos, quatro refletivos pirolíticos, três refletivos metalizados a vácuo e dois laminados, os quais foram instalados em aberturas de 1,00 X
1,20m nas células-teste, localizadas em fachadas com orientação norte e oeste. A análise foi realizada separadamente para as duas orientações. Avaliou-se o desempenho térmico de cada vidro, tendo o incolor, de espessura 4mm, como referência. A metodologia utilizada consistiu na aquisição de dados mensuráveis de parâmetros ambientais: temperaturas superficiais internas dos vidros, temperaturas de bulbo seco no ambiente interno e temperaturas do ar externo. O fator de ganho solar foi calculado a partir dos resultados de absortância dos diferentes materiais, obtidos por análise espectrofotométrica, e diferenças entre as temperaturas interna e externa. Os resultados mostram o alto ganho de calor através dos vidros planos, sendo o incolor o de pior desempenho térmico, com maior ganho, seguido pelo bronze, cinza e verde. Os vidros refletivos metalizados a vácuo apresentam o melhor desempenho térmico, dentre os materiais analisados, quando se tem como objetivo atenuar o ganho de calor e projetar edificações com menor consumo energético para refrigeração / Abstract: Thermal performance of buildings depends on several factors, such as implantation, orientation, materials and building components, which should be appropriately defined for different climate conditions. The building acts as a controller of the climatic variables, through the building envelope (walls, floor, roof and openings) and the nearby elements. Building design must provide indoor comfort and energy efficiency. Glazing easily allows the penetration of solar radiation into buildings, due to its transparency to solar radiation. So glasses must be carefully considered in building design, having in mind their potential for internal heating. In this work studies about the behavior of transparent façades, in real conditions, were carried out through measurements in six test-cells with dimensions 2,00 x 2,50m. Fourteen types of glasses were selected: five float glasses, four reflective glasses produced by pyrolitic process, three reflective ones obtained by vacuum metal deposition and two laminated glasses. Their spectral behavior was known from previous spectrophotometric studies. The glasses were installed in 1,00 X 1,20m openings in two façades facing north and west, separately. The colorless 4mm float glass was taken as reference. Internal surface temperatures of glasses, internal dry bulb temperatures and outdoor temperatures were collected. Solar gain factor was calculated on the basis of absortance values, obtained from spectrophotometrical nalysis, and temperature differences inside and outside the cells. Results show a high heat gain through float glasses, with the worst thermal behavior for the colorless one, followed by bronze, gray and green. Furthermore, reflective glasses obtained by vacuum metal deposition present the best thermal performance for the purpose of heat gain attenuation and to
design buildings with the least energy consumption for cooling / Doutorado / Edificações / Doutor em Engenharia Civil
|
6 |
Aperfeiçoamento de um sistema de medição de ganho de calor solar através de aberturasMarinoski, Deivis Luis January 2005 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Civil. / Made available in DSpace on 2013-07-15T22:48:21Z (GMT). No. of bitstreams: 1
224009.pdf: 2197274 bytes, checksum: c13afb176f9a4762aa756409bbe3a36a (MD5) / Este trabalho apresenta um estudo de aperfeiçoamento de um sistema de medição de ganho de calor solar para materiais translúcidos e modelos de janelas em escala reduzida. O sistema possibilita quantificar a fração de ganho térmico por radiação que penetra no ambiente através de uma abertura. Para medir o fluxo de calor, foi utilizada uma nova classe de transdutor (fluxímetro), chamado "a gradiente tangencial". Inicialmente, foi realizada uma etapa de calibração dos sensores utilizados nos testes (fluxímetros, termopares e piranômetro), e algumas modificações na estrutura do equipamento. Após isso foram realizadas medições em campo. O protótipo originalmente utiliza um sistema de dissipação de calor através de ventiladores que insuflam o ar diretamente na face posterior da chapa de suporte dos fluxímetros. A elevação da diferença de temperatura entre a chapa e o ar ambiente reduz a passagem do fluxo de calor através dos sensores, gerando erros na medição. Os resultados da etapa de medições, após a calibração dos sensores, demonstraram a ocorrência de um erro médio no valor do Fator Solar medido de aproximadamente 5,8%, com uma diferença média de temperatura de 11,1°C entre a chapa de suporte dos fluxímetros e o ar. Novos testes foram realizados sendo aplicado um sistema de resfriamento por circulação de água em um banho termostático. Utilizando este sistema de resfriamento, a diferença média de temperatura entre a chapa de suporte dos fluxímetros e o ar caiu para aproximadamente 0,2°C, e o erro médio no resultado do Fator Solar medido foi de apenas 0,4%. Também, um modelo matemático simplificado de transferência de calor foi desenvolvido para verificar os erros nos valores medidos através de análises paramétricas. Os resultados das medições e das análises paramétricas demonstrando a necessidade de modificação do sistema de resfriamento originalmente utilizado.
This work presents a study about the improvement of a measurement system for solar heat gain determination of translucent materials and windows models in reduced scale. The system allows the quantification of the thermal fraction of radiation gain that penetrates the room through a fenestration. In order to measure the heat flow a new class of transducer ("tangential gradient" heat fluxmeter) was used. Initially, a stage of calibration of the sensors (heat fluxmeters, thermocouples and pyranometer) used in the tests was accomplished, following some structural modifications in the equipment. After this, outdoor measurements were carried out. Originally the equipment used a heat dissipation system with fans that insufflate air directly on the backside of the heat fluxmeters' support plate. The raise of temperature difference between the plate and the external air reduces the heat flow passing through the sensors, causing errors in the measurement. The first measurements, after calibrations of sensors, demonstrated the occurrence of an average error in the value of measured SHGC (Solar Heat Gain Coefficient) of around 5,8%, with an average temperature difference of 11,1°C between the plate and the external air. New tests were accomplished with a system of cooling the plate through water circulation in a thermostatic bath. The decrease in the temperature difference between the heat fluxmeters' support plate and the air provided good results. Using this cooling system, the average temperature difference between the plate and the external air decreased to 0,2°C approximately, and the average error in the result of measured SHGC was only 0,4%. Also, a simplified mathematical model was developed to verify the error in measured values through parametrical analyses. The results of measurements and parametrical analyses demonstrated the necessity of the modification in the originally used cooling system.
|
7 |
Absortancia solar de superficies opacas : metodos de determminação e base de dados para tintas latex acrilica e PVA / Solar absorptance of opaque surfaces : a determination methods and data base for latex acrylic and PVA coatingsDornelles, Kelen Almeida 16 April 2008 (has links)
Orientador: Mauricio Roriz / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-11T13:02:36Z (GMT). No. of bitstreams: 1
Dornelles_KelenAlmeida_D.pdf: 6559934 bytes, checksum: 3966f1604b84180c07c07723d60bf746 (MD5)
Previous issue date: 2008 / Resumo: A radiação solar é responsável por importante parcela da carga térmica dos edifícios e seu impacto sobre esta carga depende, principalmente, da absortância solar do envelope construtivo. A falta de dados precisos e atualizados de absortância solar para superfícies opacas faz com que pesquisadores e especialistas utilizem a percepção visual ou adotem tabelas baseadas em cores, consagrando-se o conceito de que a absortância seria crescente na medida em que as cores fossem mais escuras. Para comprovar que a visão humana não é instrumento adequado para indicar o quanto uma superfície absorve de energia solar, este trabalho apresenta dados de absortância solar para diferentes cores e tipos de tintas utilizadas em superfícies opacas de edificações no Brasil, a partir de medições de refletância em espectrofotômetro. Com base nesses dados, são propostos métodos de determinação da absortância solar de superfícies opacas, que podem ser utilizados por projetistas, pesquisadores e especialistas. Além do espectrofotômetro, apresenta-se um método que se baseia na digitalização de amostras em scanner comum e posterior classificação de suas cores a partir dos sistemas cromáticos digitais RGB e HSL. O segundo método utiliza dados de refletância obtidos através do espectrômetro ALTA II e o terceiro método baseia-se em medidas de temperaturas superficiais das amostras, a partir de absortâncias medidas para amostras de cores branca e preta, adotadas como referência. Os dados de absortância solar obtidos com o
espectrofotômetro foram ajustados ao espectro solar padrão, considerando-se que a energia solar não é constante ao longo do espectro. Este ajuste indicou que a absortância diminui quando submetida às diferentes intensidades da radiação solar. Finalmente, analisou-se o efeito da rugosidade superficial sobre a absortância solar de amostras pintadas com diferentes cores de tintas, cujos resultados indicaram que a rugosidade aumenta linearmente a absortância das superfícies. As diversas análises e discussões apresentadas neste trabalho comprovam que apenas a cor não é fator determinante da absortância de uma superfície opaca. Além disso, os métodos propostos para sua quantificação são bastante precisos e confiáveis, cujos valores estimados através dos métodos do scanner, ALTA II e medida de temperaturas superficiais apresentaram diferenças inferiores a 10%, 6,8% e 3,7%, respectivamente, quando comparados com as absortâncias medidas em espectrofotômetro / Abstract: Solar radiation is the main responsible factor for the thermal load of buildings, and its impact over this load depends, mainly, on the solar absorptance of the building envelope. The lack of reliable and current data implies that researchers and specialists use visual perception or adopt tables based on surface colors to quantify the solar absorptance, which enhances the concept that absorptance increases as much as colors are darker. In order to show that the human eye is not reliable indicator of how much solar energy a surface absorbs, this work presents solar absorptance data for different paint colors, which are commonly used in Brazilian façades, measured with a spectrophotometer. Based on these data, determination methods of solar absorptance are proposed and can be used by designers, researchers, and specialists. Besides the spectrophotometer, it is presented a method based on samples digital images through a scanner, in which samples were classified according to the RGB and HSL digital chromatic systems. The second method uses the reflectances of samples measured with the ALTA II spectrometer, and the third method is based on the samples surface temperatures and the absorptances of black and white reference samples. Solar absorptance data measured with the spectrophotometer were adjusted to the standard solar spectrum, because the solar energy is not constant along the solar spectrum. This correction indicated solar absorptance diminishes when submitted to different solar radiation intensities. Finally, the influence of roughness on the solar absorptance was analyzed, whose results indicated roughness linearly increases surfaces solar absorptance. The several analysis and discussions presented in this work prove that only color is not a determinant factor of the solar absorptance. Furthermore, proposed methods are very reliable to identify the solar absorptance of opaque surfaces, whose estimated values with scanner, ALTA II, and surface temperature methods presented differences under 10%, 6,8%, and 3,7%, respectively, when compared to the absorptances measured with the spectrophotometer / Doutorado / Arquitetura e Construção / Doutor em Engenharia Civil
|
8 |
Avaliação do desempenho termico de tres tipologias de brise-soleil fixo / Thermal performance of three different fixed shading devicesGutierrez, Grace Cristina Roel 12 March 2004 (has links)
Orientador: Lucila Chebel Labaki / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-07T10:20:33Z (GMT). No. of bitstreams: 1
Gutierrez_GraceCristinaRoel_M.pdf: 13332804 bytes, checksum: 2e59e6bab72a64cce872302835c70d3c (MD5)
Previous issue date: 2004 / Resumo: Esta pesquisa avalia o desempenho térmico do brise-soleil, em relação à radiação solar incidente em ambientes com aberturas protegidas. Os dispositivos testados foram selecionados considerando as tipologias e materiais utilizados em edificações da arquitetura moderna brasileira entre os anos 1930 e 1960. O desempenho térmico do brise-soleil é reconhecido em estudos de geometria de
insolação e simulação com software, porém são raras as avaliações experimentais sob condições climáticas reais. A metodologia utilizada é baseada em pesquisas de desempenho térmico de elementos e componentes construtivos realizadas em protótipos. Através de um sistema de aquisição de dados são verificadas: variáveis ambientais (temperatura do ar, umidade relativa, radiação solar, pluviosidade, direção e velocidade dos ventos), e variáveis medidas nos protótipos (temperaturas do ar e superficiais). Os ensaios de campo foram realizados em protótipos localizados em Campinas, SP. Foram testados brise-soleil horizontal e vertical em madeira e concreto, e elemento vazado (concreto), fixos, expostos nas fachadas norte ou oeste, durante uma semana em cada orientação, nos períodos próximos aos equinócios e solstícios de verão e inverno. Nos ensaios realizados, os resultados mostraram a redução pontual de até 4,14ºC na temperatura interna, sendo o melhor desempenho térmico o da tipologia combinada. O brise-soleil vertical fixo perpendicular à fachada apresentou os piores resultados na fachada oeste, contrariando indicações usuais da literatura arquitetônica / Abstract: In this work the thermal performance of shading devices regarding solar radiation in indoor spaces with protected openings is analyzed. The typology and materials of shading devices were selected considering the elements used in Brazilian modern architecture buildings between the 1930 and 1960 decades. Most studies about shading devices are based on geometric drawings and software simulation analyzing the efficiency of provided protection during specific periods, however there are few experimental works performed under real climate conditions. In this investigation, three different devices were evaluated in the most problematic conditions of exposure, by acquiring measurable data of external parameters (air temperature, relative humidity, solar radiation, rain, wind speed and direction) and internal parameters (air temperature and surface temperatures) to verify their efficiency. These experiments were conducted at School of Civil Engineering, Architecture and Urban Design of State University of Campinas (UNICAMP) in the State of São Paulo, Brazil. The investigated devices were horizontal and vertical sun-breakers of concrete and wood, and concrete eggcrate sunbreaker, fixed, on north and west exposures, for a week in each façade, in equinox and summer and winter solstices periods. In these tests, the eggcrate typology showed the best thermal performance, with a punctual reduction of up to 4,14ºC on internal air temperature. The vertical fixed devices registered the worst results on west façade, in contrast with current Brazilian architectural literature recommendation / Mestrado / Edificações / Mestre em Engenharia Civil
|
9 |
Os impactos das alterações do clima no direito ambiental do trabalho: a saúde coletiva do trabalhador a céu aberto e na construção civil.Santos, Gustavo Abrahão dos 01 April 2016 (has links)
Submitted by Rosina Valeria Lanzellotti Mattiussi Teixeira (rosina.teixeira@unisantos.br) on 2016-08-09T18:20:11Z
No. of bitstreams: 1
Gustavo Abrah¿o dos Santos.pdf: 1810524 bytes, checksum: 2eaefbccae262fa0bc6061286f82adc0 (MD5) / Made available in DSpace on 2016-08-09T18:20:11Z (GMT). No. of bitstreams: 1
Gustavo Abrah¿o dos Santos.pdf: 1810524 bytes, checksum: 2eaefbccae262fa0bc6061286f82adc0 (MD5)
Previous issue date: 2016-04-01 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The theme of this work is the worker's collective health, exposed to risks arising from climate change, for work in the open. The study has the purpose of showing the environmental impacts of climate affect the public health worker, often subject to open in the external
environment, with solar power. Regarding the questioning, this occurs in relation to a worker who works in the open and in construction, performing their work subjected to solar charge without receiving the interest of the employer to minimize or neutralize the effects of heat and ultraviolet radiation in these lives. Moreover, the questioning is more reluctant when it prevails the pollution in the environment labor law by failing to apply the principles of environmental law, nor the necessary health protection instruments in the work space, when
the failure of employers to international standards and national Related to the theme on screen. As a result of the inscribed problem, clarify are the possible diseases that come from the solar charge exposure as well as recognition of the Nexus Technical Epidemiological Pension (NTEP) in the case of skin cancer and worker exposure to ultraviolet radiation, when active in construction civil. Already as a possible solution, the three-dimensionality of the
protection of occupational health in the open and in construction is shown; namely: management, technical and legal. The management solution is elucidated by means of the management systems of the International Organization for Standardization (ISO); the technical solution is illustrated from the Program of Environmental Risk Prevention Program (PPRA) and the Conditions and Environment Programme of Work in the Construction Industry; while the legal solution is by Collective Bargaining Convention, as well as
legislative changes that protect occupational health. Finally, the methodology used is the historical normative construction of national and international binding and non-binding documents. / O tema desta dissertação é a saúde coletiva do trabalhador, exposto a riscos decorrentes das alterações climáticas, por trabalho a céu aberto. O estudo possui como objetivo demonstrar que os impactos ambientais do clima atingem a saúde coletiva do trabalhador, não raro sujeito a céu aberto, em ambiente externo, com carga solar. No tocante à problematização, esta se dá em relação ao trabalhador que atua a céu aberto e na construção civil, desempenhando o seu labor submetido a carga solar, sem receber o interesse do empregador em minimizar ou neutralizar os efeitos do calor e da radiação ultravioleta nessas vidas. Mais ainda: a problematização é mais relutante quando se prepondera a poluição no direito ambiental do trabalho, ao não se aplicarem os princípios do direito ambiental, tampouco os instrumentos necessários de tutela à saúde no espaço laboral, quando do descumprimento dos empregadores
às normativas internacionais e nacionais relacionadas ao tema em tela. Como consequência do problema inscrito, elucidam-se as possíveis doenças advindas da exposição à carga solar, bem como o reconhecimento do Nexo Técnico Epidemiológico Previdenciário (NTEP), no caso de câncer de pele e exposição do trabalhador à radiação ultravioleta, quando atuante na construção civil. Já como possível solução, é apresentada a tridimensionalidade da tutela da saúde ocupacional a céu aberto e na construção civil; a saber: gestão, técnica e legal. A solução de gestão é elucidada por meio dos sistemas de gestão da Organização Internacional para Padronização (ISO); a solução técnica é ilustrada a partir do Programa de Prevenção de Riscos Ambientais (PPRA) e do Programa de Condições e Meio Ambiente do Trabalho na Indústria da Construção Civil; enquanto a solução legal ocorre por Convenções Coletivas de Trabalho, bem como alterações legislativas que tutelem a saúde ocupacional. Enfim, a
metodologia utilizada é a construção histórica normativa dos documentos e internacionais e nacionais vinculantes e não vinculantes.
|
Page generated in 0.0708 seconds