• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 48
  • 40
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 96
  • 96
  • 85
  • 40
  • 33
  • 32
  • 17
  • 13
  • 12
  • 11
  • 10
  • 10
  • 10
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

The resistance of cavity bases and a cavity liner upon thermal conduction by amalgam restorations a thesis submitted in partial fulfillment ... pedodontics /

Hayakawa, James K. January 1968 (has links)
Thesis (M.S.)--University of Michigan, 1968.
52

In vitro evaluation of bacterial penetration around varnish-lined amalgam restorations a thesis submitted in partial fulfillment ... pedodontics /

Vonk, James D. January 1969 (has links)
Thesis (M.S.)--University of Michigan, 1969.
53

Laboratory study on cavity liners as protectors of the pulp against the effect of silicate cement a thesis submitted in partial fulfillment ... [operative dentistry] /

Segat, Leon. January 1948 (has links)
Thesis (M.S.)--University of Michigan, 1948.
54

An in-vitro study evaluating the efficacy of the Ultrasonic Bypass System using different intracanal irrigating solutions

Barney, Jason Phillip, January 2010 (has links)
Thesis (M.S.D.)--Indiana University School of Dentistry, 2010. / Title from PDF t. p. (viewed July 28, 2010) Advisor(s): Mychel Vail, Chair of the Research Committee, Joseph Legan, B. Keith Moore, Kenneth Spolnik, Susan Zunt. Curriculum vitae. Includes abstract. Includes bibliographical references (leaves 93-109).
55

Influência do método de preparo cavitário, alta rotação e laser de Er:YAG, sobre a espessura da camada híbrida de diferentes sistemas adesivos, com diferentes filosofias adesivas / Influence of cavity preparation method, high speed turbine and Er:YAG laser, on hybrid layer thickness of different adhesive systems

Marcos de Oliveira Barceleiro 11 October 2006 (has links)
O objetivo deste estudo foi promover uma comparação entre as espessuras de camadas híbridas formadas entre os sistemas adesivos Scotchbond Multi-Uso Plus, Single Bond 2, Prime & Bond 2.1 e Xeno III, e a superfície dentinária, preparada com dois métodos de preparo cavitário, a ponta diamantada montada em turbina de alta rotação, e o laser de Er:YAG, utilizado com dois parâmetros de energia (200 e 400 mJ) e dois parâmetros de freqüência (4 e 6 Hz). Para a realização deste experimento, foram realizados tratamentos superficiais com os dois métodos descritos em fragmentos de dentina superficial aplainada, retirados de vinte terceiros molares humanos recém-extraídos, seguido de preparo da dentina com os sistemas adesivos. Após a aplicação e fotoativação de uma camada de compósito sobre a dentina preparada, os corpos de prova foram cortados, polidos e preparados para visualização em MEV, meio pelo qual foram realizadas cinco medidas da espessura da camada híbrida formada em cada corpo de prova. Os resultados obtidos foram tratados estatisticamente por ANOVA e teste de Student-Newnan-Keuls, em um nível de significância de 95%, e por Kruskal Wallis e Mann Whitney, também em um nível de significância de 95%, através do programa SPSS for Windows release 5.0. A análise foi realizada levando-se em consideração dois fatores de estudo, a presença ou não de camada híbrida e a espessura da camada híbrida. Em relação ao fator espessura da camada híbrida, quando se avaliou o tipo de preparo realizado, a análise estatística por ANOVA e Student-Newman-Keuls levou a formação de quatro grupos homogêneos, sendo Grupo I (ponta diamantada) > Grupo II (Laser 200 mJ / 4 Hz) = Grupo III (Laser 200 mJ / 6 Hz) > Grupo IV (Laser 400 mJ / 4 Hz) > Grupo V (Laser 400 mJ / 6 Hz). Quando se avaliou o tipo de sistema adesivo utilizado, não se encontrou diferença estatisticamente significante. Em relação ao fator presença de camada híbrida, quando se avaliou o tipo de preparo realizado, a análise estatística por Kruskal Wallis e Mann Whitney levou a formação de três grupos homogêneos (Grupo I _ Grupo II = Grupo III = Grupo IV _ Grupo V). Quando se avaliou o tipo de sistema adesivo utilizado, não se encontrou diferença estatisticamente significante. Quando se realizou o cruzamento tipo de preparo x sistema adesivo, a análise estatística mostrou a formação de sete grupos distintos. Pela análise dos resultados obtidos neste estudo in vitro, foi possível concluir que em dentina preparada com ponta diamantada em alta rotação, os quatro sistemas adesivos testados formaram camadas híbridas de formato regular e presentes de forma constante, com espessura média de 2,90 1,71 m, e em dentina preparada com laser de Er:YAG, os quatro sistemas adesivos testados formaram camadas híbridas de formato irregular e presentes de forma intermitente, com espessura média variando entre 0,41 1,00 m e 2,06 2,49 m. Além disso, concluiu-se que o laser de Er:YAG com os parâmetros testados influencia negativamente a formação da camada híbrida, e que os métodos de preparo cavitário influenciam na espessura da camada híbrida. / The objective of this study was to compare the thickness of the hybrid layer formed using Scotchbond Multipurpose Plus, Single Bond 2, Prime & Bond 2.1 and Xeno III on dentine surface, prepared with a diamond bur in a high speed handpiece, or prepared with an Er:YAG laser, used with two parameters of pulse energy (200 and 400 mJ) and two parameters of frequency (4 and 6 Hz). Flat dentine surfaces obtained from twenty third molars human teeth were treated with the two methods, and then were prepared with the dentine adhesive systems, according to manufacturers instructions. After a layer of composite was applied, specimens were sectioned, flattened, polished and prepared for Scanning Electronic Microscopy observation. Five different measurements of hybrid layer thickness were obtained along the bonded surface in each specimen. Results were statistically analyzed using analysis of variance and Student-Newman-Keuls tests (p ≤ 0.05), and using Kruskal Wallis and Mann Whitney tests (p ≤ 0.05). The statistical analysis was made considering two observations parameters, the presence of the hybrid layer, and its thickness. When analyzing the hybrid layer thickness, and comparing the cavity preparation method, four groups were formed, Group I (diamond bur) > Group II (Laser 200 mJ / 4 Hz) = Group III (Laser 200 mJ / 6 Hz) > Group IV (Laser 400 mJ / 4 Hz) > Group V (Laser 400 mJ / 6 Hz). When comparing the dentine adhesive systems, it was not found any statistically significant difference. When analyzing the presence of hybrid layer, and comparing the cavity preparation method, three groups were formed (Group I ≠ Group II = Group III = Group IV ≠ Group V). When comparing the dentine adhesive systems, it was not found any statistically significant difference. When analyzing the hybrid layer thickness, and comparing the cavity preparation method x the dentine adhesive systems, it was found seven different groups. These results showed that the four tested dentine adhesive systems produce a 2.90 1.71 μm hybrid layer in dentine prepared with diamond bur. This hybrid layer was regular and constantly found. In the laser groups, the dentine adhesive systems produced hybrid layers ranging from 0.41 1.00 μm to 2.06 2.49 μm, which were very irregular and were not found constantly. It was also concluded that Er:YAG laser with the parameters used in this experiment, is a negative influence to the hybrid layer formation, and that cavity preparation methods do influence the hybrid layer formation.
56

Estudo de preparos e da forma da infraestrutura na distribuição de tensões em prótese parcial fixa

Yamamoto, Eron Toshio Colauto [UNESP] 06 July 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-07-06Bitstream added on 2014-06-13T19:20:23Z : No. of bitstreams: 1 yamamoto_etc_dr_sjc.pdf: 2267197 bytes, checksum: 537fb4ee2e9f4f60f9c4e4cdae9ad336 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo do estudo foi verificar o comportamento de prótese fixa de três elementos confeccionada em Zircônia e dos dentes suportes quando são utilizados diferentes preparos dos dentes suportes e diferentes formas da infra-estrutura. Simulou-se a ausência do segundo pré-molar superior e realizou-se preparos do tipo ocluso-proximal, proximal-ocluso-proximal, preparo para overlay e para coroa total nos dentes suportes. Utilizou-se dois tipos de formato de conector, o convencional e em forma de arco. Os modelos tridimensionais foram realizados em softwares CAD Rhinoceros® e 3D Studio Max®. Os modelos tridimensionais simularam uma secção da maxila na região entre primeiro pré-molar e primeiro molar e foram compostos por osso medular e cortical, ligamento periodontal, dentina e esmalte. Foi realizada análise de elementos finitos, as análises de tensões foram processadas no programa Ansys®. Os resultados foram apresentados por meio de mapas de cores de tensão/deformação, com a distribuição de tensões e valores numéricos. Os diferentes preparos dos dentes suportes não influenciaram na distribuição de tensões nos dentes suportes. O preparo de coroa total foi o único preparo que diminui a tensão sobre a infra-estrutura. O formato do conector foi significativamente diferente. O conector em forma de arco distribui melhor as tensões na infra-estrutura do que o conector convencional / The aim of this study was to investigate the behavior of three elements fixed partial denture made of three elements made of Zirconia and support teeth when use different preparations of the support teeth and different forms of framework. Simulated the absence of the superior second premolar and the support teeth preparation was occlusal-proximal, proximal-occlusal-proximal, overlay preparation and full crown. We used two types of connector format, the conventional and arc-shaped. The three-dimensional models were made in Rhinoceros CAD software and 3D Studio Max. The model was composed with maxillary first premolar and first molar, cortical and medullary bone, periodontal ligament, dentin and enamel. Analyses of stresses were processed in the program ANSYS ®. The results were presented in color maps of stress / strain, with the stress distribution and numerical values. The different preparations of the support teeth didn´t influence the stress distribution in supppot teeth. The preparation of full crown was the only preparation that reduces the strain on the infrastructure. The shape of the connector was significantly different. The arch-shaped connector was better than conventional connector in the framework stress distribution
57

Desmineralização do esmalte dental adjacente a restaurações. Efeito dos parâmetros do laser de Er:YAG empregado para o preparo cavitário / Enamel demineralization around dental restoration. Effect of Er:YAG laser parameters employed to cavity preparation

Vivian Colucci 01 February 2010 (has links)
O presente estudo, composto por dois experimentos, teve como objetivo avaliar in vitro o efeito de parâmetros do laser de Er:YAG na desmineralização do esmalte dental humano e bovino após desafio cariogênico e avaliar, através de um modelo in situ, o efeito de diferentes parâmetros do laser de Er:YAG no desenvolvimento de lesões de cárie adjacente a restaurações. No estudo in vitro, terceiros molares inclusos humanos hígidos e incisivos bovinos foram seccionados para a seleção de 50 fragmentos de cada um dos substratos, que foram aleatoriamente divididos em 10 grupos, sendo 9 experimentais preparados com laser de Er:YAG com 300mJ de energia (frequência de 2Hz, 4Hz ou 6Hz, fluxo de água de 2,0mL/min, 5,0mL/min ou 8,0mL/min) e 1 controle (turbina de alta rotação). Após o preparo das cavidades, os espécimes foram restaurados com resina composta e submetidos ao desafio cariogênico. Subseqüentemente, foram seccionados para a análise da microdureza e realização de microscopia de luz polarizada qualitativa. No estudo in situ, 150 fragmentos de esmalte bovino foram distribuídos aleatoriamente entre 15 voluntários. Tais fragmentos foram subdivididos em 10 grupos conforme descrito para o estudo in vitro. Os 9 grupos experimentais foram preparados com laser de Er:YAG empregando-se diferentes combinações de parâmetros, conforme descrito pra o estudo in vitro. O grupo controle foi preparado com turbina de alta-rotação e ponta diamantada. A cavidade obtida foi restaurada com resina composta e os fragmentos foram montados em dispositivo palatino para serem instalados nos voluntários participantes para a realização do desafio cariogênico. Após o desafio, os espécimes foram seccionados para a realização das leituras de microdureza longitudinal e microscopia de luz polarizada qualitativa. Os dados obtidos no ensaio de microdureza foram analisados estatisticamente. Para o estudo in vitro foi realizada a Análise de variância e o teste de Tukey e observou-se que, independentemente do substrato testado, os espécimes preparados com turbina de alta rotação apresentaram menores médias de microdureza que os preparados com laser de Er:YAG para todos os parâmetros testados, os quais foram semelhantes entre si (p>0,05). As imagens de microscopia de luz polarizada demonstraram uma tendência dos grupos irradiados com laser de Er:YAG com uma freqüência de 2Hz apresentarem menor desmineralização. Para o estudo in situ foi realizado teste de Friedman que demonstrou haver diferença estatística entre os métodos de preparo cavitário empregados com relação as medidas de microdureza. Para identificar as diferenças entre os grupos foi realizado o teste de Wilcoxon pareado e observou-se que o grupo preparado com laser de Er:YAG com 2Hz de freqüência e 2mL/min de fluxo de água apresentou a maiores médias de microdureza, seguido por aqueles preparados com laser de Er:YAG com 2Hz de freqüência e 5mL/min de fluxo de água e laser de Er:YAG com 2Hz de freqüência e 8mL/min de fluxo de água, respectivamente. Os grupos preparados com laser de Er:YAG com as freqüências de 4Hz e 6Hz, com fluxos de água de 2, 5 e 8mL/min apresentaram médias de microdureza menores que os grupos supracitados e com similaridade estatística entre si. Todos os grupos preparados com laser de Er:YAG demonstraram médias de microdureza superiores àquele preparado com turbina de alta-rotação, o qual apresentou as menores médias de microdureza. As imagens de microscopia de luz polarizada confirmaram os resultados obtidos com o ensaio de microdureza. Assim, pode-se concluir que o substrato bovino constitui uma alternativa ao substrato humano em estudos que avaliem o laser de Er:YAG e a progressão de lesões de cárie, que o laser de Er:YAG foi capaz de controlar o desenvolvimento de lesões de cárie adjacente a restaurações de resina composta e que o conjunto de parâmetros empregados para o preparo cavitário pode influenciar na resistência ácida do substrato irradiado. / The current study, composed by two experiments, sought to evaluate in vitro the effect of Er:YAG laser parameters on human and bovine enamel demineralization after cariogenic challenges and to check, through an in situ model, the effect of different Er:YAG laser parameters on development of caries-like lesions adjacent to dental restorations. In the in vitro study, sound human third molars and bovine incisors were cut to select 50 specimens of each substrate, which were randomly allocated into 10 groups: 9 experimental groups prepared with Er:YAG laser with 300mJ output (frequency of 2Hz, 4Hz or 6Hz, water flow rate of 2.0mL/min, 5.0mL/min or 8.0mL/min) and 1 control group (High speed handpiece). After cavity preparation, the specimens were restored with composite resin and submitted to the cariogenic challenge. Afterwards, they were sectioned to obtain the microhardness measurements and images of light polarized microscopy. In the in situ study, 150 bovine enamel slabs were randomly allocated among 15 volunteers. These specimens were subdivided into 10 groups, as described above to the in vitro study. 9 experimental groups were prepared with Er:YAG laser under different parameters combination. The control group was prepared with high speed handpiece associated to a diamond bur. The prepared cavity was restored with a composite resin and the slabs were mounted on palatal appliance to be installed in the volunteers to the realization of the cariogenic challenge. After this, the specimens were sectioned to the longitudinal microhardness measurements and to the qualitative light polarized microscopy. The data obtained by means of microhardness test were statistically analyzed. For the in vitro study was performed Analisys of Variance and Tukeys test, which demonstrated that, regardless the tested substrate, the specimens prepared with high speed handpiece showed lower microhardness means than those prepared with the Er:YAG laser for all tested parameters, which were statistically similar (p>0,05). The light polarized microscopy images demonstrated that the groups irradiated with Er:YAG laser with 2Hz frequency showed a tendency to be less susceptible to the demineralization. For the in situ study was performed the Friedman test, which demonstrated that there are statistical difference among the cavity preparation methods according to the microhardness measurements. To indentify the differences among groups it was performed the Wilcoxon paread test and it was observed that the group prepared with Er:YAG laser with 2Hz of frequency and 2.0mL/min of water flow rate showed the highest microhardness means, followed by that prepared with Er:YAG laser with 2Hz of frequency and 5.0mL/min of water flow rate and Er:YAG laser with 2Hz of frequency and 8.0mL/min of water flow rate, respectively. The groups prepared with Er:YAG laser with 4Hz and 6Hz of frequency, with water flow rates of 2.0, 5.0 and 8.0mL/min showed microhardness means lower than that the groups cited above and statistical similarity among them. All groups prepared with Er:YAG laser demonstrated microhardness means higher than that prepared with high speed handpiece, what showed the lowest microhardness means. The light polarized microscopy images confirmed the results obtained with the microhardness test. Thus, it may be concluded that the bovine substrate constitutes an alternative to the human substrate in studies that evaluates the Er:YAG laser and caries-like lesions progression, that the Er:YAG laser was capable to control the development of caries-like lesions around composite resin restorations and that the parameters employed to the cavity preparation could influence on acid resistance of the irradiated substrate.
58

Efetividade de corte das pontas do sistema CVDentUS: estudo in vitro

Lima, Luciana Monti [UNESP] 19 December 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:48Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-12-19Bitstream added on 2014-06-13T20:56:56Z : No. of bitstreams: 1 lima_lm_me_arafo.pdf: 817104 bytes, checksum: 137c4b299daadfdf7ba4a2a6bd1a030b (MD5) / A tecnologia CVD (Chemical Vapor Deposition) aplicada à confecção de pontas odontológicas diamantadas possibilitou aderência do diamante à haste metálica suficiente para suportar o efeito do ultra-som, surgindo então uma técnica alternativa para corte de tecido dentário. O objetivo deste estudo in vitro foi avaliar a efetividade dos corte realizados com as pontas CVD cilíndrica e esférica para ultra-som (pontas CVDentUSÒ), em esmalte e dentina de dentes permanentes, variando-se o sentido de movimento (frontal e lateral). Foram utilizados 40 terceiros molares, num total de 80 preparos cavitários confeccionados por meio de um dispositivo padronizador. Os cortes foram realizados com 30 movimentos consecutivos da ponta sobre a superfície dentária, correspondendo a 27 segundos de utilização das pontas CVDentUSÒ. A profundidade e largura dos preparos cavitários foram analisadas em microscopia eletrônica de varredura e medidas por meio de uma análise cefalométrica modificada no programa Radiocef 4.0 (Radiocef Memory Ltda). A análise estatística pelo teste não paramétrico de Kruskal-Wallis ao nível de significância de 5% mostrou que as maiores médias de largura e profundidade foram observadas nos preparos de dentina, sendo a ponta esférica responsável por cavidades mais profundas e a cilíndrica por cavidades mais largas, não havendo influência dos sentidos de movimento da ponta. / The CVD (Chemical Vapor Deposition) technology applied in dental diamond burs manufacture allowed to the diamond to have enough adherence to the metallic stem supporting the ultrasound effect. This technique is bringing back an alternative method to cut dental tissue. The aim of this in vitro study was to evaluate the cutting effectiveness of cylindrical and round CVD-coated diamond burs for ultrasound (CVDentUSÒ system), in enamel and dentine of permanent teeth, changing the movement sense (frontal and lateral). Forty third molars were used, in a total of 80 cavity preparations made using a standard device. The cuts were made with 30 consecutive movements of the bur on the dental surface, corresponding to 27 seconds of CVDentUSÒ tips use. The depth and width of the cavity preparations were analyzed by scanning electronic microscopy and the measures were made using a modified cefalometric analysis in a Radiocef 4.0 program (Radiocef Memory Ltda). The statistical analysis applying Kruskal-Wallis non-parametric test, at 5% significance level, showed that the largest width and depth averages were observed in dentine cavities, being the round bur responsible for deeper cavities and the cylindrical for wider cavities. The movement senses had no influence on cavity size.
59

Avaliação das dimensões e aspectos morfológicos da cavidade promovida pela ablação do esmalte de dentes decíduos irradiados pelo laser de Er:YAG /

Giusti, Juçaíra Stella Martins. January 2002 (has links)
Resumo: O propósito desse estudo in vitro foi analisar as características morfológicas das cavidades em esmalte promovidas pela irradiação de dentes decíduos com laser de Er:YAG, bem como avaliar as dimensões das cavidades de acordo com a variação de energia aplicada, 200 mJ e 300 mJ , mantendo-se constante a freqüência de 10 Hz e 10 s o tempo de aplicação. Foram utilizados quatorze dentes decíduos esfoliados, que foram irradiados e tiveram seu diâmetro e profundidade medidos por meio de fotomicrografias obtidas após microscopia eletrônica de varredura, utilizando um programa de análise cefalométrica. Pudemos observar que as características morfológicas são as mesmas observadas por outros autores em dentes permanentes: cavidades arredondadas com bordas delimitadas e presença de escamas ou flocos no fundo da cavidade.Quanto às dimensões dos preparos observou-se que o diâmetro da cavidades não aumentou significativamente com o aumento da energia (média de 1033,37 mm para 200 mJ e 1083,75 mm para 300 mJ), enquanto a profundidade teve um aumento estatisticamente significante em relação ao aumento da energia aplicada (média de 153,69 mm para 200 mJ e 296,67 mm para 300 mJ). O volume foi estatisticamente superior nos preparos realizados com 300 mJ de energia. / Abstract: The aim of this "in vitro" study was to analyze the morphology, diameter, depth and volume of the cavities prepared in deciduous teeth enamel using laser. Fourteen exfoliated teeth were irradiated by Er:YAG laser set at 200 and 300 mJ of energy and 10Hz of frequency, applied during 10 seconds. The morphology, diameter and depth of the cavities were measured on scanning electron micrographs using a cephalometric program and the volume was calculated. The cavities presented round shape and flakes or scales pattern were observed in the bottom. There was no significant statistical difference in the diameter of the cavities when 200 mJ (1033,37 mm) or 300 mJ (1083,75 mm) were used. The depth was statistically greater when energy was increased ( 153,69 mm and 296,67 mm to 200 and 300 mJ respectively). The volume also increased when 300 mJ was use. / Orientador: Lourdes Aparecida Martins dos Santos Pinto / Banca: Rita de Cássia Loiola Cordeiro / Banca: Miriam Eiko Katuti Tanimoto / Coorientador: Vanderlei Salvador Bagnato / Mestre
60

Influência do método de preparo cavitário, alta rotação e laser de Er:YAG, sobre a espessura da camada híbrida de diferentes sistemas adesivos, com diferentes filosofias adesivas / Influence of cavity preparation method, high speed turbine and Er:YAG laser, on hybrid layer thickness of different adhesive systems

Marcos de Oliveira Barceleiro 11 October 2006 (has links)
O objetivo deste estudo foi promover uma comparação entre as espessuras de camadas híbridas formadas entre os sistemas adesivos Scotchbond Multi-Uso Plus, Single Bond 2, Prime & Bond 2.1 e Xeno III, e a superfície dentinária, preparada com dois métodos de preparo cavitário, a ponta diamantada montada em turbina de alta rotação, e o laser de Er:YAG, utilizado com dois parâmetros de energia (200 e 400 mJ) e dois parâmetros de freqüência (4 e 6 Hz). Para a realização deste experimento, foram realizados tratamentos superficiais com os dois métodos descritos em fragmentos de dentina superficial aplainada, retirados de vinte terceiros molares humanos recém-extraídos, seguido de preparo da dentina com os sistemas adesivos. Após a aplicação e fotoativação de uma camada de compósito sobre a dentina preparada, os corpos de prova foram cortados, polidos e preparados para visualização em MEV, meio pelo qual foram realizadas cinco medidas da espessura da camada híbrida formada em cada corpo de prova. Os resultados obtidos foram tratados estatisticamente por ANOVA e teste de Student-Newnan-Keuls, em um nível de significância de 95%, e por Kruskal Wallis e Mann Whitney, também em um nível de significância de 95%, através do programa SPSS for Windows release 5.0. A análise foi realizada levando-se em consideração dois fatores de estudo, a presença ou não de camada híbrida e a espessura da camada híbrida. Em relação ao fator espessura da camada híbrida, quando se avaliou o tipo de preparo realizado, a análise estatística por ANOVA e Student-Newman-Keuls levou a formação de quatro grupos homogêneos, sendo Grupo I (ponta diamantada) > Grupo II (Laser 200 mJ / 4 Hz) = Grupo III (Laser 200 mJ / 6 Hz) > Grupo IV (Laser 400 mJ / 4 Hz) > Grupo V (Laser 400 mJ / 6 Hz). Quando se avaliou o tipo de sistema adesivo utilizado, não se encontrou diferença estatisticamente significante. Em relação ao fator presença de camada híbrida, quando se avaliou o tipo de preparo realizado, a análise estatística por Kruskal Wallis e Mann Whitney levou a formação de três grupos homogêneos (Grupo I _ Grupo II = Grupo III = Grupo IV _ Grupo V). Quando se avaliou o tipo de sistema adesivo utilizado, não se encontrou diferença estatisticamente significante. Quando se realizou o cruzamento tipo de preparo x sistema adesivo, a análise estatística mostrou a formação de sete grupos distintos. Pela análise dos resultados obtidos neste estudo in vitro, foi possível concluir que em dentina preparada com ponta diamantada em alta rotação, os quatro sistemas adesivos testados formaram camadas híbridas de formato regular e presentes de forma constante, com espessura média de 2,90 1,71 m, e em dentina preparada com laser de Er:YAG, os quatro sistemas adesivos testados formaram camadas híbridas de formato irregular e presentes de forma intermitente, com espessura média variando entre 0,41 1,00 m e 2,06 2,49 m. Além disso, concluiu-se que o laser de Er:YAG com os parâmetros testados influencia negativamente a formação da camada híbrida, e que os métodos de preparo cavitário influenciam na espessura da camada híbrida. / The objective of this study was to compare the thickness of the hybrid layer formed using Scotchbond Multipurpose Plus, Single Bond 2, Prime & Bond 2.1 and Xeno III on dentine surface, prepared with a diamond bur in a high speed handpiece, or prepared with an Er:YAG laser, used with two parameters of pulse energy (200 and 400 mJ) and two parameters of frequency (4 and 6 Hz). Flat dentine surfaces obtained from twenty third molars human teeth were treated with the two methods, and then were prepared with the dentine adhesive systems, according to manufacturers instructions. After a layer of composite was applied, specimens were sectioned, flattened, polished and prepared for Scanning Electronic Microscopy observation. Five different measurements of hybrid layer thickness were obtained along the bonded surface in each specimen. Results were statistically analyzed using analysis of variance and Student-Newman-Keuls tests (p ≤ 0.05), and using Kruskal Wallis and Mann Whitney tests (p ≤ 0.05). The statistical analysis was made considering two observations parameters, the presence of the hybrid layer, and its thickness. When analyzing the hybrid layer thickness, and comparing the cavity preparation method, four groups were formed, Group I (diamond bur) > Group II (Laser 200 mJ / 4 Hz) = Group III (Laser 200 mJ / 6 Hz) > Group IV (Laser 400 mJ / 4 Hz) > Group V (Laser 400 mJ / 6 Hz). When comparing the dentine adhesive systems, it was not found any statistically significant difference. When analyzing the presence of hybrid layer, and comparing the cavity preparation method, three groups were formed (Group I ≠ Group II = Group III = Group IV ≠ Group V). When comparing the dentine adhesive systems, it was not found any statistically significant difference. When analyzing the hybrid layer thickness, and comparing the cavity preparation method x the dentine adhesive systems, it was found seven different groups. These results showed that the four tested dentine adhesive systems produce a 2.90 1.71 μm hybrid layer in dentine prepared with diamond bur. This hybrid layer was regular and constantly found. In the laser groups, the dentine adhesive systems produced hybrid layers ranging from 0.41 1.00 μm to 2.06 2.49 μm, which were very irregular and were not found constantly. It was also concluded that Er:YAG laser with the parameters used in this experiment, is a negative influence to the hybrid layer formation, and that cavity preparation methods do influence the hybrid layer formation.

Page generated in 0.0832 seconds