• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento e validação de bioensaio para determinação de ceftarolina em pó para solução injetável : estudo prelimiar de estabilidade

Mascarello Junior, Idamir José January 2017 (has links)
Neste trabalho, foram desenvolvidos e validados métodos analítico e microbiológico, bem como estudo preliminar de estabilidade, cinética de degradação e citotoxicidade da Ceftarolina Fosamila em pó para solução injetável, um antibiótico da classe das cefalosporinas de quinta geração, indicado para pneumonias adquiridas na comunidade e infecções graves, de pele e tecidos moles. A validação do ensaio microbiológico pelo método de difusão em ágar cilindros em placa, delineamento 3x3, apresentou resultados satisfatórios, como especificidade, linearidade na faixa de 2,0 - 8,0 μg/mL, precisão (109,42 %), exatidão (102,3 %) e robustez. Soluções de Cefatarolina Fosamila do produto acabado expostas à radiação UVC (254 nm) e à degradação térmica a 60 °C foram utilizadas para avaliar a especificidade do bioensaio. A robustez foi avaliada através da alteração da concentração do meio inoculado (0,8 e 1,2 %). O desenvolvimento e validação de método por CLAE foi avaliado através da especificidade, linearidade, precisão, exatidão e robustez. No método cromatográfico foi utilizado cromatógrafo à liquido de alta eficiência SHIMADZU com coluna Agilent® C18, fase móvel (água com trietilamina 1,0% pH 5,0:acetonitrila 87:13 v/v). O método apresentou-se específico, linear, no intervalo de 5,0 - 60,0 μg/mL, preciso (110,0 %), exato (100,68 %) e robusto. Os métodos microbiológico e cromatográfico validados foram comparados estatisticamente e verificou-se não haver diferença significativa entre eles quando comparados através do teste “t” de Student. No estudo preliminar de estabilidade constatou-se ser estável em hidrólise ácida (0,1 M) e luz UVA no período avaliado, e instável frente à degradação térmica (40 e 60 °C), oxidativa com peróxido de hidrogênio, básica em NaOH (0,1 M e 0,01 M) e luz UVC. As cinéticas de degradação frente à luz UVC e degradação térmica 60 °C mostraram que as amostras possuem cinética de degradação de ordem zero e de segunda ordem, respectivamente. O ensaio de citotoxicidade demonstrou não haver diferença entre a condição normal e a amostra submetida à degradação forçada, sugerindo que os possíveis produtos de degradação formados não alteraram o resultado. / In this work, analytical and microbiological methods were developed and validated, as well as a preliminary study of the stability, degradation kinetics and cytotoxicity to Ceftaroline Fosamil powder for injectable solution, this is a fifth generation cephalosporin antibiotic indicated for community-acquired pneumonia and severe infections of the skin and soft tissues. The validation of the microbial assay by diffusion method in 3x3 cylinder agar delineated showed satisfactory results in specificity, linearity in the range of 2.0 - 8.0 μg / mL, precision (109.42 %), accuracy (102.3 %) and robustness. The development and validation of the method by HPLC was evaluated through specificity, linearity, precision, accuracy and robustness. In the chromatographic method was used high performance liquid chromatograph from SHIMADZU with Agilent® C18 column, mobile phase (water with triethylamine 1.0 % pH 5.0: acetonitrile 87:13 v/v). The method was linear, specific in the range of 5.0 - 60.0 μg/mL, accurate (110.0 %), exact (100.68 %) and robust. The validated microbiological and chromatographic methods were compared statistically and there was no significant difference between them when compared through Student's t-test. In the preliminary stability study, it was found stable in acid hydrolysis (0.1M) and UVA light in the period evaluated, and instable against thermal degradation (40 and 60 °C), oxidative with hydrogen peroxide, basic in NaOH (0.1 M and 0.0 1M) and UVC light. Samples exposed in UVC light an thermal degradation at 60°C showed degradation kinetics following zero order and second order, respectively. The cytotoxicity assay showed no difference between the normal condition and the sample submitted to forced degradation, suggesting that the possible degradation products formed did not change the result.
2

Desenvolvimento e validação de bioensaio para determinação de ceftarolina em pó para solução injetável : estudo prelimiar de estabilidade

Mascarello Junior, Idamir José January 2017 (has links)
Neste trabalho, foram desenvolvidos e validados métodos analítico e microbiológico, bem como estudo preliminar de estabilidade, cinética de degradação e citotoxicidade da Ceftarolina Fosamila em pó para solução injetável, um antibiótico da classe das cefalosporinas de quinta geração, indicado para pneumonias adquiridas na comunidade e infecções graves, de pele e tecidos moles. A validação do ensaio microbiológico pelo método de difusão em ágar cilindros em placa, delineamento 3x3, apresentou resultados satisfatórios, como especificidade, linearidade na faixa de 2,0 - 8,0 μg/mL, precisão (109,42 %), exatidão (102,3 %) e robustez. Soluções de Cefatarolina Fosamila do produto acabado expostas à radiação UVC (254 nm) e à degradação térmica a 60 °C foram utilizadas para avaliar a especificidade do bioensaio. A robustez foi avaliada através da alteração da concentração do meio inoculado (0,8 e 1,2 %). O desenvolvimento e validação de método por CLAE foi avaliado através da especificidade, linearidade, precisão, exatidão e robustez. No método cromatográfico foi utilizado cromatógrafo à liquido de alta eficiência SHIMADZU com coluna Agilent® C18, fase móvel (água com trietilamina 1,0% pH 5,0:acetonitrila 87:13 v/v). O método apresentou-se específico, linear, no intervalo de 5,0 - 60,0 μg/mL, preciso (110,0 %), exato (100,68 %) e robusto. Os métodos microbiológico e cromatográfico validados foram comparados estatisticamente e verificou-se não haver diferença significativa entre eles quando comparados através do teste “t” de Student. No estudo preliminar de estabilidade constatou-se ser estável em hidrólise ácida (0,1 M) e luz UVA no período avaliado, e instável frente à degradação térmica (40 e 60 °C), oxidativa com peróxido de hidrogênio, básica em NaOH (0,1 M e 0,01 M) e luz UVC. As cinéticas de degradação frente à luz UVC e degradação térmica 60 °C mostraram que as amostras possuem cinética de degradação de ordem zero e de segunda ordem, respectivamente. O ensaio de citotoxicidade demonstrou não haver diferença entre a condição normal e a amostra submetida à degradação forçada, sugerindo que os possíveis produtos de degradação formados não alteraram o resultado. / In this work, analytical and microbiological methods were developed and validated, as well as a preliminary study of the stability, degradation kinetics and cytotoxicity to Ceftaroline Fosamil powder for injectable solution, this is a fifth generation cephalosporin antibiotic indicated for community-acquired pneumonia and severe infections of the skin and soft tissues. The validation of the microbial assay by diffusion method in 3x3 cylinder agar delineated showed satisfactory results in specificity, linearity in the range of 2.0 - 8.0 μg / mL, precision (109.42 %), accuracy (102.3 %) and robustness. The development and validation of the method by HPLC was evaluated through specificity, linearity, precision, accuracy and robustness. In the chromatographic method was used high performance liquid chromatograph from SHIMADZU with Agilent® C18 column, mobile phase (water with triethylamine 1.0 % pH 5.0: acetonitrile 87:13 v/v). The method was linear, specific in the range of 5.0 - 60.0 μg/mL, accurate (110.0 %), exact (100.68 %) and robust. The validated microbiological and chromatographic methods were compared statistically and there was no significant difference between them when compared through Student's t-test. In the preliminary stability study, it was found stable in acid hydrolysis (0.1M) and UVA light in the period evaluated, and instable against thermal degradation (40 and 60 °C), oxidative with hydrogen peroxide, basic in NaOH (0.1 M and 0.0 1M) and UVC light. Samples exposed in UVC light an thermal degradation at 60°C showed degradation kinetics following zero order and second order, respectively. The cytotoxicity assay showed no difference between the normal condition and the sample submitted to forced degradation, suggesting that the possible degradation products formed did not change the result.
3

Desenvolvimento e validação de bioensaio para determinação de ceftarolina em pó para solução injetável : estudo prelimiar de estabilidade

Mascarello Junior, Idamir José January 2017 (has links)
Neste trabalho, foram desenvolvidos e validados métodos analítico e microbiológico, bem como estudo preliminar de estabilidade, cinética de degradação e citotoxicidade da Ceftarolina Fosamila em pó para solução injetável, um antibiótico da classe das cefalosporinas de quinta geração, indicado para pneumonias adquiridas na comunidade e infecções graves, de pele e tecidos moles. A validação do ensaio microbiológico pelo método de difusão em ágar cilindros em placa, delineamento 3x3, apresentou resultados satisfatórios, como especificidade, linearidade na faixa de 2,0 - 8,0 μg/mL, precisão (109,42 %), exatidão (102,3 %) e robustez. Soluções de Cefatarolina Fosamila do produto acabado expostas à radiação UVC (254 nm) e à degradação térmica a 60 °C foram utilizadas para avaliar a especificidade do bioensaio. A robustez foi avaliada através da alteração da concentração do meio inoculado (0,8 e 1,2 %). O desenvolvimento e validação de método por CLAE foi avaliado através da especificidade, linearidade, precisão, exatidão e robustez. No método cromatográfico foi utilizado cromatógrafo à liquido de alta eficiência SHIMADZU com coluna Agilent® C18, fase móvel (água com trietilamina 1,0% pH 5,0:acetonitrila 87:13 v/v). O método apresentou-se específico, linear, no intervalo de 5,0 - 60,0 μg/mL, preciso (110,0 %), exato (100,68 %) e robusto. Os métodos microbiológico e cromatográfico validados foram comparados estatisticamente e verificou-se não haver diferença significativa entre eles quando comparados através do teste “t” de Student. No estudo preliminar de estabilidade constatou-se ser estável em hidrólise ácida (0,1 M) e luz UVA no período avaliado, e instável frente à degradação térmica (40 e 60 °C), oxidativa com peróxido de hidrogênio, básica em NaOH (0,1 M e 0,01 M) e luz UVC. As cinéticas de degradação frente à luz UVC e degradação térmica 60 °C mostraram que as amostras possuem cinética de degradação de ordem zero e de segunda ordem, respectivamente. O ensaio de citotoxicidade demonstrou não haver diferença entre a condição normal e a amostra submetida à degradação forçada, sugerindo que os possíveis produtos de degradação formados não alteraram o resultado. / In this work, analytical and microbiological methods were developed and validated, as well as a preliminary study of the stability, degradation kinetics and cytotoxicity to Ceftaroline Fosamil powder for injectable solution, this is a fifth generation cephalosporin antibiotic indicated for community-acquired pneumonia and severe infections of the skin and soft tissues. The validation of the microbial assay by diffusion method in 3x3 cylinder agar delineated showed satisfactory results in specificity, linearity in the range of 2.0 - 8.0 μg / mL, precision (109.42 %), accuracy (102.3 %) and robustness. The development and validation of the method by HPLC was evaluated through specificity, linearity, precision, accuracy and robustness. In the chromatographic method was used high performance liquid chromatograph from SHIMADZU with Agilent® C18 column, mobile phase (water with triethylamine 1.0 % pH 5.0: acetonitrile 87:13 v/v). The method was linear, specific in the range of 5.0 - 60.0 μg/mL, accurate (110.0 %), exact (100.68 %) and robust. The validated microbiological and chromatographic methods were compared statistically and there was no significant difference between them when compared through Student's t-test. In the preliminary stability study, it was found stable in acid hydrolysis (0.1M) and UVA light in the period evaluated, and instable against thermal degradation (40 and 60 °C), oxidative with hydrogen peroxide, basic in NaOH (0.1 M and 0.0 1M) and UVC light. Samples exposed in UVC light an thermal degradation at 60°C showed degradation kinetics following zero order and second order, respectively. The cytotoxicity assay showed no difference between the normal condition and the sample submitted to forced degradation, suggesting that the possible degradation products formed did not change the result.
4

Treatment Strategies for Persistent Methicillin-Resistant Staphylococcus aureus Bacteraemia

Lewis, Paul O., Heil, Emily L., Covert, Kelly L., Cluck, David B. 01 October 2018 (has links)
What is known and objective: Treatment of methicillin-resistant Staphylococcus aureus (MRSA) bacteraemia is a long-standing challenge to health care, often complicated by metastatic infections, treatment failure and mortality. When MRSA bacteraemia persists despite adequate initial treatment, current Infectious Diseases Society of America guidelines recommend evaluation and removal of possible sources of infection. In addition, a change in therapy may be considered. The objective of this review was to explore the therapeutic options for the treatment of persistent MRSA bacteraemia. Methods: A literature search of PubMed, MEDLINE and Google Scholar was performed using the following search terms: [methicillin-resistant Staphylococcus aureus OR MRSA] AND [bacteraemia OR bloodstream infection] AND [persistent OR persistence OR refractory OR treatment failure OR salvage] AND treatment. We evaluated relevant, adult, English-language, peer-reviewed studies published between 1985 and May 2018. In vitro and animal studies were considered as supportive of in vivo data. Results and discussion: Randomized, controlled trials are lacking. However, case series and case reports support multiple treatment options including high-dose daptomycin in combination with an antistaphylococcal β-lactam, ceftaroline, trimethoprim-sulfamethoxazole (TMP-SMX) or fosfomycin; ceftaroline alone or in combination with vancomycin or TMP-SMX; linezolid alone or in combination with a carbapenem, or telavancin. What is new and conclusion: Given the heterogeneity of the data, a preferred regimen has not emerged. Prescribers must take into consideration recent exposure, source control, and available synergy and clinical data. Further comparative trials are needed to establish a preferred regimen and the creation of a universal treatment algorithm.

Page generated in 0.0379 seconds