• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Impact of seismic code provisions in the central U.S.: a performance evaluation of a reinforced concrete building

Kueht, Erin 15 May 2009 (has links)
The close proximity to the New Madrid Seismic Zone and the significant population and infrastructure presents a potentially substantial risk for central U.S. cities such as Memphis, Tennessee. However, seismic provisions in currently adopted Memphis building codes for non-essential structures have a lower seismic design intensity level than the 2003 International Building Code (IBC) with broader acceptance nationally. As such, it is important to evaluate structures designed with these local seismic provisions to determine whether they will perform adequately during two different design-level earthquakes in this region. A four-story reinforced concrete (RC) moment frame with wide-module pan joists was designed according to current building codes relevant to the central U.S.: the 2003 IBC, the City of Memphis and Shelby County locally amended version of the 2003 IBC, and the 1999 Standard Building Code (SBC). Special moment frames (SMFs) were required for the IBC and SBC designs, but lower design forces in the amended IBC case study permitted an intermediate moment frame (IMF). However, the margin by which a SMF was required was very small for the SBC design. For slightly different conditions IMFs could be used. Nonlinear push-over and dynamic analyses using synthetic ground motions developed for Memphis for 2% and 10% probabilities of exceedance in 50 years were conducted for each of the three designs. The FEMA 356 recommended Basic Safety Objective (BSO) is to dually achieve Life Safety (LS) for the 10% in 50 years earthquake and Collapse Prevention (CP) for the 2% in 50 years earthquake. For the member-level evaluation, the SMF designs met the LS performance objective, but none of the designs met the CP performance objective or the BSO. However, the margin by which the SMF buildings exceeded CP performance was relatively small compared to that of the IMF building. Fragility curves were also developed to provide an estimate of the probability of exceeding various performance levels and quantitative performance limits. These relationships further emphasize the benefits of using an SMF as required by the IBC and, in this case, the SBC.
2

Impact of seismic code provisions in the central U.S.: a performance evaluation of a reinforced concrete building

Kueht, Erin 15 May 2009 (has links)
The close proximity to the New Madrid Seismic Zone and the significant population and infrastructure presents a potentially substantial risk for central U.S. cities such as Memphis, Tennessee. However, seismic provisions in currently adopted Memphis building codes for non-essential structures have a lower seismic design intensity level than the 2003 International Building Code (IBC) with broader acceptance nationally. As such, it is important to evaluate structures designed with these local seismic provisions to determine whether they will perform adequately during two different design-level earthquakes in this region. A four-story reinforced concrete (RC) moment frame with wide-module pan joists was designed according to current building codes relevant to the central U.S.: the 2003 IBC, the City of Memphis and Shelby County locally amended version of the 2003 IBC, and the 1999 Standard Building Code (SBC). Special moment frames (SMFs) were required for the IBC and SBC designs, but lower design forces in the amended IBC case study permitted an intermediate moment frame (IMF). However, the margin by which a SMF was required was very small for the SBC design. For slightly different conditions IMFs could be used. Nonlinear push-over and dynamic analyses using synthetic ground motions developed for Memphis for 2% and 10% probabilities of exceedance in 50 years were conducted for each of the three designs. The FEMA 356 recommended Basic Safety Objective (BSO) is to dually achieve Life Safety (LS) for the 10% in 50 years earthquake and Collapse Prevention (CP) for the 2% in 50 years earthquake. For the member-level evaluation, the SMF designs met the LS performance objective, but none of the designs met the CP performance objective or the BSO. However, the margin by which the SMF buildings exceeded CP performance was relatively small compared to that of the IMF building. Fragility curves were also developed to provide an estimate of the probability of exceeding various performance levels and quantitative performance limits. These relationships further emphasize the benefits of using an SMF as required by the IBC and, in this case, the SBC.
3

Cooling multi-family residential units using natural ventilation in the Central U.S.

Rai, Roby January 1900 (has links)
Master of Science / Department of Architecture / Michael D. Gibson / The use of Natural Ventilation (NV) to cool buildings in mixed climates can conserve significant cooling energy. In mixed climates it is particularly important during the fall and the spring, where appropriately designed buildings should use very little energy for heating or cooling. Natural ventilation is also important in residential buildings, where internal heat gain can be managed, making cooling by natural ventilation easier. Earlier investigations have clearly shown the economic, social, and health benefits of the use of NV in built environment. Studies have shown that increased airflow or air-speed during ventilation can bring a significant rise in comfort range which further reduces the cooling energy required to maintain comfort. The climatic data of the central United States (U.S.) shows that the availability of frequent high speed wind and favorable seasonal humidity conditions make natural ventilation feasible in late spring and early fall, where NV can offset most of the cooling demand for a home or multifamily residential unit, though it is not possible to maintain thermal comfort during the entire summer with NV alone. In mixed climates, NV for multifamily residential units has not been investigated thoroughly. According to 2009 International Residential Code, multifamily residential buildings are typically designed to use a code minimum amount of operable or ventilating windows, 4% of the floor area being ventilated, while also using lightweight construction methods (such as wood framing) that is prone to fast thermal response during the overheated periods of the year. While climate may favor the use of NV in these building types, the sizing of windows and the building construction type limit the potential to save energy with NV. This study hypothesized that the maximum benefits from NV in the climate of the central U.S. requires further optimization of window openings beyond the energy code minimum, and a construction system incorporating mass that can slow thermal response during overheated periods. During the study, the climatic data of the central US was scrutinized to understand the most suitable time frames where NV could be applied in order to maintain indoor thermal comfort in various construction systems in residential buildings: mainly lightweight using wood framing, and heavier construction using concrete and masonry. The location of the housing unit, first level or second level, was also examined to account for the differences in thermal gains and losses as a result of ground coupling and additional heat gain from the roof. Further, computational fluid dynamics evaluated the comfort achieved with different ventilation areas. Change in comfort hours by using NV tested the practicability of the use of NV to maintain indoor thermal comfort for different scenarios. The study concluded with design recommendations for building orientation, operable window size, and construction type as these factors relate to thermal comfort and the optimization of multifamily residential buildings to utilize NV for energy savings in the U.S.

Page generated in 0.0626 seconds