21

Návrh větrání a chlazení v rodinném domě / Design of Cooling and ventilation system in family house

Bíza, Michal January 2019 (has links)
The diploma thesis is focused on the design of ventilation and cooling for the family house. The first part of the thesis deals with possibilities of ventilation and cooling, air ducts and their components and selected ventilation units. The next part deals with the analysis of air-conditioning routes, their dimensions and pressure losses. Then the heat gain is determined, and cooling is proposed. The last part deals with the comparison of financial costs for purchase of all components for ventilation and cooling, assembly, installation and operating costs. The enclosed drawings and item lists are at the end of the thesis.
22

Energetické hodnocení systémů VRF / Energy evaluation of systems VRF

Gašpár, Juraj January 2013 (has links)
This master thesis deals with VRF systems, which are used for extensive commercial and office buildings, or for buildings where there are multiple zones with different required parameters. The aim of the thesis is to explain the functions of the system and their evaluation and inclusion into energy classes according to the new legislation. The practical part deals with an application of the VRF system and its variants in the building of bank branch. The comparison of initials costs and resultant costs to operate the system. The experiment focuses on comparison of the measured values of VRF system and their comparison with data from the manufacturer.
23

Třírotorový lopatkový stroj pro klimatizační systém / 3-wheel air cycle machine

Vrána, Jan January 2012 (has links)
For air cooling in aircrafts is used an air cycle machine. Recently, there is focusing on incresing efficiency of air cycle and due this are added another rotors. Design of machine with three rotors is performed in this thesis.
24

Klimatizace jednoho podlaží administrativní budovy / Air - conditioning of office building

Balcar, Petr January 2012 (has links)
The main goal of the submitted thesis is the design of central conditioning system used to ensure the required internal microclimate of office space and meeting rooms on the 2nd floor of office building, located in the city of Brno. The first part provides an overview of air conditioning systems and the appropriate central air conditioning system is selected. In the next part is designed the devices for air conditioning by building layout, properties of building structures, equipment and office space occupied. The work also submits drawing documentation, technical report and specification of materials used.
25

Návrh tepelného čerpadla voda-voda / Water to water heat pump design

Jašek, František January 2012 (has links)
First part of my diploma thesis contains theoretical description of compressor based heat pumps, refrigeration cycle, main components of refrigeration cycle and auxiliary equipment. Second part contains the heat pump WATER-WATER desing. It will be used for heat recovery from cogeneration units in heating plants.
26

Vliv obtokového součinitele na návrh a geometrii přímého výparníku pro chladící jednotku / The Effect of the Bypass Factor on Design and Geometry of the Evaporator for the Cooling Unit

Vytasil, Michal January 2016 (has links)
Diploma thesis focuses on effect of the bypass factor on design and geometry of the evaporator for the cooling unit of data centre. Effect of the bypass factor on individual design parameters is solved in detail. All dependendecies are captured by using graphs in which s placed a cement on that parameter. In part C, mathematical and physical solutions are demonstrated calculations and processes leading to the design of the exchanger. In the end, evaluation of the calculations is done and there is also showed possible improvements for the practise.
27

Chladicí jednotka domácího pivovaru / Cooling unit for home brewery

Straka, Miroslav January 2016 (has links)
This diploma thesis deals with producing and using low temperatures in home brewing processes. The introductory part describes technological process of brewing beer, followed by a design of a primary fermentation vessel and next an aging vessel. In the next step a suitable wort chiller is designed. All the equipment is designed to be able to run on batteries or a solar photovoltaic panel.
28

Optimalizace vzduchotechniky wellness sportovního centra / Optimization of air conditioning of the wellness sports center

Prchalová, Nikol January 2022 (has links)
The diploma thesis deals with microclimate of a pool hall. This is divided into three parts. The first part describes the theoretical aspects of the environment in swimming pools in general. The second part of the diploma thesis deals with the calculation of the course of specific moisture concentration during the day in the pool hall. Different humidity concentration curves are assessed based on different electable input parameters. Subsequently, suitable setting options are evaluated in order to achieve acceptable environment in the hall in terms of humidity and optimal operating costs. The last part relates to the experimental part. This examines the measurement of evaporation under different boundary conditions and the subsequent comparison with some calculation methods for the calculation of evaporation.
29

Vývoj elektroforetické metody stanovení fosfátů a borátů v nemrznoucích směsích / Development of the electrophoretic method for determination of phosphates and borates in cooling mixtures

Listakhava, Iryna January 2021 (has links)
In this diploma thesis, a method of routine analysis of commercial coolants was developed, focused on the simultaneous determination of inorganic anions - phosphates and borates - as corrosion inhibitors in fresh mixtures and the markers of recycling quality. The method was developed for the instrumental technique of capillary zone electrophoresis with indirect detection at 254 nm. The following were optimized: background electrolyte (its composition, concentration, pH), measured samples (coolant dilution, suitable internal standard) and measurement conditions (capillary length, sample dosing). The influence of the sample matrix on the measurement results, the robustness of the calibration line (or the agreement of the response with the actual analyte concentration) and also the repeatability of the method were tested. Optimizations and tests resulted in a method based on a standard addition with the following parameters: background electrolyte of pH = 11.50 containing sodium chromate at 10 mmol l-1 concentration and CTAB at 1 mmol l-1 concentration; dilution of the coolant sample 20-50×, addition of internal standard MES at 0,1 mmol l-1 concentration, electrokinetic sample injection at -5 kV for 10 s, capillary length 50.0 cm, inner diameter 75 μm. The repeatability of the method expressed as a...
30

Vzduchotechnika hotelového komplexu / Air Conditioning of Hotel Komplex

Očkan, Tomáš January 2014 (has links)
The first part of the thesis is aimed on creating internal microclimate of the hotel complex by air conditioning systems. The choice of systems is based on theoretical knowledge’s and practical application in abroad. In the second part there is designed solution for hotel apartments and conference hall. The other areas are designed only conceptual. Technical solutions of chosen systems are the main outcome of the thesis. In the third part there are published my experimental measurements from laboratories of Oulu University of Applied Sciences. For the study field of Air Conditioning has been chosen Air Flow Measurement and Test Operation of HVAC unit. For the study field of Renewable Energy has been chosen the Heat Pump and for study field of Refrigeration has been chosen Water Cooling and Chiller Box.