• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • Tagged with
  • 16
  • 16
  • 10
  • 9
  • 8
  • 8
  • 7
  • 7
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação de algumas propriedades físico-químicas do cimento AH Plus puro e acrescido de hidróxido de cálcio

Duarte, Marco Antonio Hungaro 01 October 1999 (has links)
Algumas propriedades físico-químicas como radiopacidade, tempo de presa, escoamento, pH, liberação de cálcio e infiltração apical do cimento AH Plus puro ou modificado foram analisadas e comparadas in vitro às do óxido de zinco e eugenol. As modificações realizadas no AH Plus constaram do acréscimo de 5% e 10% de hidróxido de cálcio em peso. Para análise da radiopacidade, os cimentos foram acondicionados em anéis com 10 mm de diâmetro e 2mm de altura de acordo com norma no 57 da ADA e a determinação dos valores se deram através do sistema de imagem digital Digora e depois foram convertidos em mm de Al. Para o teste de tempo de presa os cimentos, também, foram colocados em anéis metálicos e com auxílio de agulha Gilmore de 453,6 gr de peso determinou-se o tempo de presa final. Na avaliação do escoamento, os cimentos foram preparados e 0,5mL deles foram colocados sobre uma placa de vidro e, em seguida, outra placa com um peso totalizando 120 gramas foi colocada sobre o cimento e após 10 minutos mediu-se o maior e menor diâmetro do mesmo e a média dos dois foi o valor do escoamento. Na análise da infiltração apical dentes caninos humanos tiveram seus canais instrumentados e a seguir as superfícies externas impermeabilizadas, para então, proceder-se a obturação pela técnica do cone único com os cimentos em estudo. Na seqüência foram imersos em azul de metileno a 2% durante 7 dias. Finalizado esse período, os dentes foram removidos do corante, lavados, raspados seccionados e a infiltração do marcador foi determinada em microscópio óptico munido de ocular micrometrada. Para análise do pH e liberação de cálcio, os cimentos foram colocados em tubos com 1cm de comprimento e 1 mm de diâmetro e, posteriormente, imersos em 20 mL de água deionizada. Nos períodos de 24h, 48h, 7dias, 14dias e 30 dias, 4mL da solução eram removidos e, então, se media o pH com auxílio de pHmetro e a liberação de cálcio através de espectrofotômetro de absorção atômica. Os resultados mostraram que o acréscimo de hidróxido de cálcio ao cimento AH Plus não interferiu significantemente na radiopacidade, não alterou o tempo de presa, melhorou o escoamento, principalmente com o acréscimo de 5%, favoreceu significantemente o selamento apical e propiciou um pH mais alcalino, bem como liberação de ions cálcio. Com relação ao AH Plus puro, evidenciou-se um baixo selamento apical e um escoamento muito elevado. / Some physico-chemical properties as radiopacity, cure time, flow, pH, calcium release, and apical leakage of AH Plus plain or modified were analyzed and compared in vitro to the ones of zinc oxide eugenol. The changes performed in the Ah-plus cement implied in a 5% and 10% increase of calcium hydroxide in weight. For the radiopacity analysis, the cements were placed in 10mm diameter and 2mm hight rings according to the nº 57 ADA norm and the values determination were given by the Digora digital image system and latter converted in mm of Al. For the cure time test, the cements were also placed in metal rings and with the aid of a Gilmore needle weighing 453.6 it was determined the final cure time. In the flow assessment, the cements were prepared and 0,5mL of them were placed on a glass slab and, immediately, another slab with a weight totalizing 120 gr was placed on the cement and after 10 minutes the largest and smaller cement diameter was measured and the average of both was considered the flow value. For the assessment of apical leakage, human canine or cuspid teeth had their canals instrumented and the external surfaces impermealized before proceding the obturation by the simple cone technique with the cements under study. In sequence the teeth were immersed in methilene blue 2% during 7 days. After this period, the teeth were removed from the die, washed, scrubbed, seccioned and the marker leakage was determined in an optical microscope with micrometered ocular. For the pH and calcium release assessment, the cements were placed in tubes measuring 1cm in length and 1mm in diameter and later immersed in 20mL of deionized water. Measurements were made in 24 hours, 48 hours, 7 days, 14 days and 30 days, when 4mL of the solution were removed to assess the pH with the aid of a pHmeter, and the calcium release through a spectrophometer of atomic absorption. The results showed that the increase of calcium hydroxide to the AH Plus cement did not significantly interfere in the radiopacity, did not alter the cure time, improved the flow, specially with the addition of 5%, significantly favored the apical sealing and provided a more alcaline pH, as well as calcium íons release. As to the plain AH Plus, it was evidenced a low apical sealing and a very high flow rate.
2

Avaliação de algumas propriedades físico-químicas do cimento AH Plus puro e acrescido de hidróxido de cálcio

Marco Antonio Hungaro Duarte 01 October 1999 (has links)
Algumas propriedades físico-químicas como radiopacidade, tempo de presa, escoamento, pH, liberação de cálcio e infiltração apical do cimento AH Plus puro ou modificado foram analisadas e comparadas in vitro às do óxido de zinco e eugenol. As modificações realizadas no AH Plus constaram do acréscimo de 5% e 10% de hidróxido de cálcio em peso. Para análise da radiopacidade, os cimentos foram acondicionados em anéis com 10 mm de diâmetro e 2mm de altura de acordo com norma no 57 da ADA e a determinação dos valores se deram através do sistema de imagem digital Digora e depois foram convertidos em mm de Al. Para o teste de tempo de presa os cimentos, também, foram colocados em anéis metálicos e com auxílio de agulha Gilmore de 453,6 gr de peso determinou-se o tempo de presa final. Na avaliação do escoamento, os cimentos foram preparados e 0,5mL deles foram colocados sobre uma placa de vidro e, em seguida, outra placa com um peso totalizando 120 gramas foi colocada sobre o cimento e após 10 minutos mediu-se o maior e menor diâmetro do mesmo e a média dos dois foi o valor do escoamento. Na análise da infiltração apical dentes caninos humanos tiveram seus canais instrumentados e a seguir as superfícies externas impermeabilizadas, para então, proceder-se a obturação pela técnica do cone único com os cimentos em estudo. Na seqüência foram imersos em azul de metileno a 2% durante 7 dias. Finalizado esse período, os dentes foram removidos do corante, lavados, raspados seccionados e a infiltração do marcador foi determinada em microscópio óptico munido de ocular micrometrada. Para análise do pH e liberação de cálcio, os cimentos foram colocados em tubos com 1cm de comprimento e 1 mm de diâmetro e, posteriormente, imersos em 20 mL de água deionizada. Nos períodos de 24h, 48h, 7dias, 14dias e 30 dias, 4mL da solução eram removidos e, então, se media o pH com auxílio de pHmetro e a liberação de cálcio através de espectrofotômetro de absorção atômica. Os resultados mostraram que o acréscimo de hidróxido de cálcio ao cimento AH Plus não interferiu significantemente na radiopacidade, não alterou o tempo de presa, melhorou o escoamento, principalmente com o acréscimo de 5%, favoreceu significantemente o selamento apical e propiciou um pH mais alcalino, bem como liberação de ions cálcio. Com relação ao AH Plus puro, evidenciou-se um baixo selamento apical e um escoamento muito elevado. / Some physico-chemical properties as radiopacity, cure time, flow, pH, calcium release, and apical leakage of AH Plus plain or modified were analyzed and compared in vitro to the ones of zinc oxide eugenol. The changes performed in the Ah-plus cement implied in a 5% and 10% increase of calcium hydroxide in weight. For the radiopacity analysis, the cements were placed in 10mm diameter and 2mm hight rings according to the nº 57 ADA norm and the values determination were given by the Digora digital image system and latter converted in mm of Al. For the cure time test, the cements were also placed in metal rings and with the aid of a Gilmore needle weighing 453.6 it was determined the final cure time. In the flow assessment, the cements were prepared and 0,5mL of them were placed on a glass slab and, immediately, another slab with a weight totalizing 120 gr was placed on the cement and after 10 minutes the largest and smaller cement diameter was measured and the average of both was considered the flow value. For the assessment of apical leakage, human canine or cuspid teeth had their canals instrumented and the external surfaces impermealized before proceding the obturation by the simple cone technique with the cements under study. In sequence the teeth were immersed in methilene blue 2% during 7 days. After this period, the teeth were removed from the die, washed, scrubbed, seccioned and the marker leakage was determined in an optical microscope with micrometered ocular. For the pH and calcium release assessment, the cements were placed in tubes measuring 1cm in length and 1mm in diameter and later immersed in 20mL of deionized water. Measurements were made in 24 hours, 48 hours, 7 days, 14 days and 30 days, when 4mL of the solution were removed to assess the pH with the aid of a pHmeter, and the calcium release through a spectrophometer of atomic absorption. The results showed that the increase of calcium hydroxide to the AH Plus cement did not significantly interfere in the radiopacity, did not alter the cure time, improved the flow, specially with the addition of 5%, significantly favored the apical sealing and provided a more alcaline pH, as well as calcium íons release. As to the plain AH Plus, it was evidenced a low apical sealing and a very high flow rate.
3

Influência do tamanho de partículas nas propriedades físico-químicas do cimento endodôntico CER

Zagato, Erick Fazanha [UNESP] 13 January 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-01-13Bitstream added on 2014-06-13T19:12:24Z : No. of bitstreams: 1 zagato_ef_me_ilha.pdf: 261736 bytes, checksum: d0251ba5867a2a4a3e37c5f78ca9c4ee (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Desde 1993, o mineral trioxide aggregate tem sido amplamente investigado e os resultados confirmam que ele possui excelentes propriedades físicas, químicas e biológicas. Apesar do sucesso e uso deste cimento, duas dificuldades têm sido apontadas pelos profissionais: o difícil manuseio e tempo de presa muito longo. Recentemente, um novo cimento endodôntico, intitulado CER, foi desenvolvido no laboratório do grupo Vidros e Cerâmicas. A inclusão de uma emulsão em sua composição deu ao cimento uma extraordinária consistência de trabalho e uma acentuada redução no tempo de presa. O primeiro estudo com o material mostrou que o CER tem a mesma habilidade de liberar íons que o mineral trioxide aggregate. Como continuidade na caracterização do CER, este trabalho apresenta resultados obtidos com o estudo do efeito do tamanho de partículas do pó de cimento no tempo de presa e na expansão térmica, e um estudo comparativo de infiltração marginal entre o CER e o MTA-Angelus. / Since 1993, the mineral trioxide aggregate has been widely investigated and the results confirm that it has excellent physical, chemical, and biologic properties. In spite of this, one of the difficulties reported by clinicians when using MTA is its poor handling characteristic and lengthy setting time. Recently, a novel endodontic cements, entitled CER, it was developed in the laboratory of the Glasses and Ceramic group. The inclusion of an emulsion in its composition gave to it an extraordinary handling and one accentuated reduction in the setting time as compared to MTA. The first study with the material showed that CER has the same ability to release ions than the mineral trioxide aggregate. This work presents results obtained from study of effects of particle size of the CER cement powder on setting time and thermal expansion, and from a comparative study of sealing ability between CER and MTA-Angelus.
4

Estudo comparativo entre diferentes cimentos endodônticos em relação à resistência de união do conjunto cimento resinoso/pino de fibra de vidro à dentina radicular / Comparative study between different endodontic sealers in relation to the bond strength of the resin cement / fiberglass post complex to the root dentin

Soares, Isadora Mello Vilarinho 03 August 2018 (has links)
O objetivo do estudo foi avaliar, comparativamente, a influência do cimento biocerâmico EndoSequence BC a diferentes cimentos endodônticos sobre a resistência de união do conjuno cimento resinoso/pino de fibra de vidro à dentina radicular. Setenta e dois dentes caninos selecionados tiveram a coroa seccionada transversalmente e o remanescente radicular padronizado em 17mm. O canal radicular foi preparado com Reciproc R50 e NaOCl 1%. Os espécimes foram distribuídos conforme o cimento obturador utilizado (n=12): G1-controle (sem cimento); G2- óxido de zinco e eugenol (EndoFill) G3- hidróxido de cálcio (Sealapex); G4- resina epóxi (AHPlus); G5-resina epóxi e hidróxido de cálcio (Sealer Plus) e G6- biocerâmico (EndoSequence BC). Decorridas 48h da obturação, as raízes foram desobturadas e preparadas para receber o pino de fibra de vidro. Após secagem do canal, os pinos foram cimentados com Panavia F 2.0. Dez raízes de cada grupo foram seccionadas transversalmente para obtenção dos slices. O primeiro slice de cada terço foi submetido ao teste de resistência de união (push-out) e padrão de falha. No segundo slice foi avaliada a interface adesiva dentina/cimento resinoso, por meio de microscopia de varredura confocal a laser (MVCL). Dois espécimes de cada grupo não tiveram o pino cimentado no canal radicular e foram destinados à microscopia eletrônica de varredura para observação de remanescente de material obturador na superfície dentinária. Os dados referentes à resistência de união foram submetidos ao teste Shapiro-Wilk, seguido de ANOVA two way. Os dados referentes à MVCL foram analisados pelo teste Kruskal-Wallis seguido pelo teste Dunn ( = 5%). Os grupos controle e AHPLus apresentaram os maiores valores de RU (p<0,05). Os cimentos EndoSequence BC, Sealer Plus e Sealapex apresentaram os valores intermediários de RU, sem diferença estatística entre eles. O cimento EndoFill apresentou os menores valores de RU com diferença estatisticamente significante em relação aos demais grupos (p<0,05). Quanto aos terços radiculares, os maiores valores de RU foram observados no terço cervical (p<0,05). As imagens de MEV demonstraram no geral, presença de poucos remanescentes de material obturador na superfície radicular em todos os grupos. Quanto a análise da interface cimento resinoso/dentina, a maioria dos grupos apresentou adaptação razoável, com exceção do EndoFill. Concluiu-se que os cimentos endodônticos Endosequence BC, Sealapex, Sealer Plus e EndoFill influenciaram negativamente a RU do conjunto pino/cimento resinoso à dentina radicular / The aim of this study was to compare the influence of EndoSequence BC bioceramic sealer on the bond strength (BS) of resin cement/fiber post in root canals filled with different sealers. The coronary of seventy-two canines were removed and the root length standardized at 17mm. The root canal was prepared with Reciproc R50 and 1% NaOCl. The specimens were distributed according to the filling material used (n=12): G1- control (no sealer); G2- zinc oxide and eugenol (EndoFill) G3- calcium hydroxide (Sealapex); G4- epoxy resin (AHPlus); G5- epoxy resin and calcium hydroxide (Sealer Plus) and G6- bioceramic (EndoSequence BC). Later forthy eight hours, the roots were prepared to insert the fiberpost. Fiberposts were attached with Panavia F 2.0. Ten roots of each group were sectioned transversely, obtaining slices of cervical, medium and apical root canal thirds. The BS of the first slice of each third was evaluated by push-out test and failures was analyzed by stereo microscope. The interface between dentin wall/resin cement of the second slice was evaluated by confocal laser microscopy (CLM). Two specimens from group were not restored with fiberpost, and assigned to scanning electron microscopy (SEM) to analyze the remaining material on the dentin surface. Data on the bond strength were submitted to the Shapiro-Wilk test, followed by two way ANOVA. The CLM data were submitted to the Kruskal-Wallis and Dunn tests ( = 5%). The control and AHPLus groups had the highest RU values (p <0.05). The EndoSequence BC, Sealer Plus and Sealapex sealers presented the intermediate values of RU, with no statistical difference between them. EndoFill sealer presented the lowest values of RU with a statistically significant difference in relation to the other groups (p <0.05). Regarding root thirds, the highest BS values were observed in cervical third (p <0.05). SEM images showed presence of few remaning filling material on the root surface in all groups. Regarding the dentine/resin cement interfaces analyzes most of the groups presented average adaptation, unless the G2. It was concluded that Endosequence BC, Sealapex, Sealer Plus and EndoFill endodontic sealers poor influenced the BS of the fiber post/resin cement in root canal dentin
5

Determinação do pH e da liberação de íons cálcio de três cimentos endodônticos quando utilizados em obturações, em conjunto com guta-percha, e da qualidade das mesmas. Avaliação realizada em longo prazo / Determination of pH, calcium ion release, and overall quality of three endodontic cements used in obturations with guta-percha. A long term evaluation

Minotti, Paloma Gagliardi 11 May 2015 (has links)
O objetivo deste estudo foi avaliar o pH e a liberação de íons cálcio dos cimentos AH Plus, MTA Fillapex e Sealapex, em diferentes períodos, quando empregados em obturações de canais radiculares, bem como, a qualidade das obturações, após 1 ano de realizadas. O pH e a liberação de íons cálcio foram avaliados por meio de um peagômetro e espectrofotômetro de absorção atômica, respectivamente. A qualidade das obturações foi avaliada por meio de um estereomicroscópio. Cento e vinte e quatro pré-molares inferiores humanos extraídos, unirradiculados, foram divididos em 01 grupo controle e 02 grupos experimentais, de acordo com a padronização do diâmetro do forame apical. Em seguida, os 02 grupos experimentais foram divididos em 4 subgrupos, considerando as técnicas de instrumentação e obturação empregadas. Após o preparo dos canais radiculares cada subgrupo teve o número de dentes divididos por dois, formando novos subgrupos, de acordo com os cimentos obturadores utilizados. Imediatamente após a obturação, a raiz de cada dente foi imersa em 15 mL de água ultrapura para avaliação do pH e liberação de íons cálcio nos seguintes períodos: 1 h, 1, 3, 7, 30, 180 e 365 dias, após a obturação. Após o período de 1 ano, os dentes foram seccionados transversalmente a 2, 4, 6 mm do forame apical para análise da qualidade das obturações, analisando-se a porcentagem de cimento, guta-percha e espaços vazios na massa obturadora. Os cimentos apresentaram pH neutro, porém, aos 180 dias, os valores mostraram um ligeiro aumento quando utilizados em canais com forames de diâmetro 0,25 mm. Quando utilizados em canais com forames de diâmetro 0,45 mm, o pH mostrou-se com valores maiores para todos os períodos sem distinção do cimento. Todos os cimentos liberaram íons cálcio, com menores valores para o AH Plus. Na estereomicroscopia, observaram-se variações nas porcentagens de cimento e guta-percha, considerando-se os diâmetros foraminais e técnicas obturadoras, e porcentagem insignificante de espaços vazios. / The objective of this study was to evaluate the pH and calcium ion release of AH Plus, MTA Fillapex and Sealapex cements at different time periods when used in root canal obturations, as well as the quality of the obturations one year after being performed. The pH and calcium ion release were evaluated by means of a pH meter and an atomic absorption spectrophotometer, respectively. The quality of the obturations was evaluated using a stereomicroscope. One hundred and twenty-four extracted human uniradicular mandibular premolars were divided into 1 control and 2 experimental groups, according to the standardization of the apical foramen diameter. Next, the 2 experimental groups were divided into 4 subgroups, considering the instrumentation techniques and obturations employed. After the preparation of the root canals, each subgroup had the number of teeth divided by two, forming new subgroups, according to the sealers used. Immediately after the obturation, the root of each tooth was immersed in 15 mL of ultrapure water for the evaluation of the pH and calcium ion release in the following time periods: 1 hr, 1, 3, 7, 30, 180 and 365 days after the obturation. After the period of one year, the teeth were transversely sectioned at 2, 4 and 6 mm from the root apex to examine the quality of the obturations, analyzing the percentage of cement, gutta-percha and voids in the obturator mass. The cements presented a neutral pH, which showed slightly increase as of 180 days when used in canals with foramens of 0.25 mm diameters. When used in canals with foramens with diameters of 0.45 mm, the pH presented higher values in all periods for all cements. All cements released calcium ions, with lower values for the AH Plus. In the stereomicroscopy, there were variations in the percentages of cement and gutta-percha, considering the foraminal diameters and obturation techniques and an insignificant percentage of voids.
6

Avaliação das propriedades físico-químicas dos cimentos obturadores dos canais radiculares à base de ionômero de vidro e silicone / Comparison of physicochemical properties of an ionomer-based and two silicon-based endodontic sealers.

Flores, Daniel Silva Herzog 17 December 2009 (has links)
Este estudo avaliou, in vitro, tempo de endurecimento (TE), alteração dimensional (AD), solubilidade (Sl) e radiopacidade (Rp) dos cimentos AH Plus, GuttaFlow, RoekoSeal, Activ GP, Endofill e um cimento experimental à base de MTA. Para estes testes o cimentos Activ GP foi manipulado na relação pó/líquido de 28 mg para 50 &micro;L de líquido. Para determinar o TE, moldes (10 X 2 mm) foram preenchidos com cimento e, decorridos 150 s, os cimentos foram testados com agulha tipo Gillmore (100 g), a cada 60 s, até que não houvesse marcas na superfície. Para o teste de alteração dimensional, 5 corpos-de-prova cilíndricos (3,58 x 3,0 mm) foram obtidos. Após a mensuração de seus comprimentos por meio de parquímetro digital, foram imersos em 2,24 mL de água destilada e deionizada por 30 dias e mensurados novamente. Para o teste de Sl, foram obtidos 10 corpos-de-prova (1,5 X 7,75 mm). Após serem pesados, dois a dois, foram imersos em 7,5 mL de água destilada por 7 dias e pesados novamente, determinando-se a perda percentual da massa. Os líquidos de imersão foram submetidos à espectrometria para detecção dos íons Ca2+, K+, Ni2+, Pb2+, Zn2+, Ag+. Para a Rp, 5 placas de acrílico com 4 perfurações (5 X 1 mm) foram preenchidas com cimento e, ao lado de escada de alumínio padronizada, foram radiografadas com distância foco-objeto de 30 cm e exposição de 0,2 s. A densidade radiográfica foi determinada por meio do Digora for Windows 1.51. Os resultados mostraram que os cimentos GuttaFlow e RoekoSeal estavam de acordo com a Especificação n° 57 da ANSI/ADA para os testes de TE e Rp. Em relação a ED, somente o Guttaflow estava de acordo com esta Especificação. Em relação à Sl, somente o cimento Activ GP (11,80%) não atendeu os padrões exigidos pela ANSI/ADA. A espectrometria de absorção atômica mostrou que o cimento Activ GP apresentou liberação expressiva de ions Ca2+. A liberação de ions Zn2+ foi evidenciada no cimento Activ GPl. Concluiu-se que somente cimento Guttaflow atendeu às exigências da ANSI/ADA em relação à radiopacidade, estabilidade dimensional e solubilidade. / This study evaluated, in vitro, the setting time (ST), dimensional alteration (DA), solubility (Sl) and radiopacity (Rp) of the sealers AH Plus, GuttaFlow, RoekoSeal, Activ GP, Endofill and a MTA-based experimental sealer. For these tests, the sealer Activ GP was prepared using a powder/liquid mixing ratio of 28 mg to 50 &micro;L of liquid. In order to determine the ST, moulds (10 x 2 mm) were filled with sealer. After 150 s, the sealers were tested with a Gilmore needle (100 g) at 60-s intervals until no marks were visible on the material surface. For the DA test, 5 cylindrical specimens (3.58 x 3.0 mm) were obtained. After having their dimensions checked with a digital caliper, the specimens were stored in 2.24 mL distilled deionized water for 30 days and their dimensions were rechecked. For the Sl test, 10 specimens (1.5 x 7.75 mm) were obtained. After being weighed in pairs, the specimens were stored in 7.5 mL distilled water for 7 days and reweighed to determine the percent mass loss. The liquids in which the specimens were immersed were subjected to spectrometry for detection of ions Ca2+, K+, Na+, Ni2+, Pb2+, Zn2+and Ag+. For the Rp test, 5 acrylic plates with 4 perforations (5 x 1 mm) were filled with sealer and were radiographed near to a graduated aluminum stepwedge with 30-cm focus-object distance and 0.2-s exposure time. The radiographic density was determined using the Digora for Windows 1.51 software. The results showed that GuttaFlow and RoekoSeal were in compliance with the ANSI/ADAs specification no. 57 for the TE and Rp tests. Regarding DA, only GuttaFlow was in accordance with this specification. Regarding Sl, only Activ GP (11.80%) did not meet the ANSI/ADAs requirements. The atomic absorbance spectrometry showed that the sealer Activ GP presented significant release of Ca2+. Release of Zn2+ ions was observed for the sealer Activ GP. In conclusion, only the sealer Guttaflow met the ANSI/ADAs requirements for radiopacity, dimensional stability and solubility.
7

Infiltração bacteriana em canais radiculares obturados com diferentes cimentos endodônticos e duas técnicas obturadoras / Bacterial leakage in root canals filled with different endodontic sealers and two techniques

Cunha, Thais Vieira Rizzo Nunes da 27 June 2011 (has links)
O objetivo deste estudo foi avaliar ex vivo a infiltração do Enterococcus faecalis em canais radiculares obturados com os cimentos endodônticos AHPlus, RealSeal e o cimento experimental Sealepox, pelas técnicas da condensação lateral e compactação vertical. Cem dentes humanos unirradiculados, com canais únicos e retos, tiveram os mesmos instrumentados, e após, as coroas removidas, para a realização das obturações. Aparatos específicos para a fixação das raízes foram confeccionados contendo meio de cultura estéril e específico para a bactéria, em questão. A inoculação deEnterococcus faecalis foi realizada e, durante 60 dias, o meio de cultura foi checado diariamente para constatar sua possível turvação, o que, caracterizaria a passagem bacteriana pela obturação. Todos os espécimes foram processados histologicamente e corados pela técnica de Brown e Brenn para exame em microscópio óptico, para constatação da presença e localização do Enteroccocus faecalis no interior dos canais radiculares e na massa dentinária. Considerando a metodologia da infiltração bacteriana, os resultados obtidos mostraram que nem os cimentos obturadores e nem as técnicas foram capazes de impedir a infiltração. Contudo, a mesma ocorreu em um pequeno número de espécimes, não sendo observadas diferenças significantes entre os cimentos e técnicas. Em relação à análise microscópica, foi observada a presença dos micro-organismos em, praticamente, todos os espécimes analisados. Tal observação permite afirmar que a metodologia da infiltração bacteriana não é confiável para se qualificar o selamento proporcionado por obturações de canais radiculares. / The aim of this study was to assess ex-vivo the leakage of Enterococcus faecalis in root canals filled with endodontic sealers AHPlus, RealSeal and the experimental sealer Sealepox, after the lateral condensation or warm vertical condensation techniques. One hundred single rooted extracted human teeth had their root canals instrumented and their crowns removed for the conducting of the obturation. An experimental bacterial leakage setup was designed for fixing the root canal in the contained media, sterile and specific for the bacteria in study. The inoculation with Enterococcus faecalis was conducted and for 60 days the media was checked daily for possible change in its clear aspect, which would than, characterize the contamination by the bacteria through the root canal. All the sample which were infiltrated, totally or not, were processed and colored by the Brown and Brenn technique for observation of presence and location of Enterococcus faecalis in the root canal or dentinal tubules. With the methodology for bacterial leakage considered, the results obtained showed that none of the sealer neither the techniques employed were able to avoid leakages. Nevertheless, leakage happened in a small number of samples, where no statistical difference could be found between sealers and techniques. In regards to the microscopy analysis, presence of microorganisms was observed in practically all the samples. Such an observation, suggests that bacterial leakage is not a trustworthy indicator for qualifying sealing obtained by sealers in root canals.
8

Determinação do pH e da liberação de íons cálcio de três cimentos endodônticos quando utilizados em obturações, em conjunto com guta-percha, e da qualidade das mesmas. Avaliação realizada em longo prazo / Determination of pH, calcium ion release, and overall quality of three endodontic cements used in obturations with guta-percha. A long term evaluation

Paloma Gagliardi Minotti 11 May 2015 (has links)
O objetivo deste estudo foi avaliar o pH e a liberação de íons cálcio dos cimentos AH Plus, MTA Fillapex e Sealapex, em diferentes períodos, quando empregados em obturações de canais radiculares, bem como, a qualidade das obturações, após 1 ano de realizadas. O pH e a liberação de íons cálcio foram avaliados por meio de um peagômetro e espectrofotômetro de absorção atômica, respectivamente. A qualidade das obturações foi avaliada por meio de um estereomicroscópio. Cento e vinte e quatro pré-molares inferiores humanos extraídos, unirradiculados, foram divididos em 01 grupo controle e 02 grupos experimentais, de acordo com a padronização do diâmetro do forame apical. Em seguida, os 02 grupos experimentais foram divididos em 4 subgrupos, considerando as técnicas de instrumentação e obturação empregadas. Após o preparo dos canais radiculares cada subgrupo teve o número de dentes divididos por dois, formando novos subgrupos, de acordo com os cimentos obturadores utilizados. Imediatamente após a obturação, a raiz de cada dente foi imersa em 15 mL de água ultrapura para avaliação do pH e liberação de íons cálcio nos seguintes períodos: 1 h, 1, 3, 7, 30, 180 e 365 dias, após a obturação. Após o período de 1 ano, os dentes foram seccionados transversalmente a 2, 4, 6 mm do forame apical para análise da qualidade das obturações, analisando-se a porcentagem de cimento, guta-percha e espaços vazios na massa obturadora. Os cimentos apresentaram pH neutro, porém, aos 180 dias, os valores mostraram um ligeiro aumento quando utilizados em canais com forames de diâmetro 0,25 mm. Quando utilizados em canais com forames de diâmetro 0,45 mm, o pH mostrou-se com valores maiores para todos os períodos sem distinção do cimento. Todos os cimentos liberaram íons cálcio, com menores valores para o AH Plus. Na estereomicroscopia, observaram-se variações nas porcentagens de cimento e guta-percha, considerando-se os diâmetros foraminais e técnicas obturadoras, e porcentagem insignificante de espaços vazios. / The objective of this study was to evaluate the pH and calcium ion release of AH Plus, MTA Fillapex and Sealapex cements at different time periods when used in root canal obturations, as well as the quality of the obturations one year after being performed. The pH and calcium ion release were evaluated by means of a pH meter and an atomic absorption spectrophotometer, respectively. The quality of the obturations was evaluated using a stereomicroscope. One hundred and twenty-four extracted human uniradicular mandibular premolars were divided into 1 control and 2 experimental groups, according to the standardization of the apical foramen diameter. Next, the 2 experimental groups were divided into 4 subgroups, considering the instrumentation techniques and obturations employed. After the preparation of the root canals, each subgroup had the number of teeth divided by two, forming new subgroups, according to the sealers used. Immediately after the obturation, the root of each tooth was immersed in 15 mL of ultrapure water for the evaluation of the pH and calcium ion release in the following time periods: 1 hr, 1, 3, 7, 30, 180 and 365 days after the obturation. After the period of one year, the teeth were transversely sectioned at 2, 4 and 6 mm from the root apex to examine the quality of the obturations, analyzing the percentage of cement, gutta-percha and voids in the obturator mass. The cements presented a neutral pH, which showed slightly increase as of 180 days when used in canals with foramens of 0.25 mm diameters. When used in canals with foramens with diameters of 0.45 mm, the pH presented higher values in all periods for all cements. All cements released calcium ions, with lower values for the AH Plus. In the stereomicroscopy, there were variations in the percentages of cement and gutta-percha, considering the foraminal diameters and obturation techniques and an insignificant percentage of voids.
9

Influência do protocolo de secagem com álcool isopropílico na adesividade de diferentes cimentos obturadores de metacrilato à dentina radicular / Influence of the drying protocol with isopropyl alcohol on the adhesion of different methacrylate-based sealers to intraradicular dentin

Dias, Kleber Campioni 12 April 2012 (has links)
O presente estudo teve como objetivo avaliar a influência do protocolo de secagem com álcool isopropílico à adesividade dos cimentos AH Plus, Hybrid Root Seal e Epiphany SE à dentina radicular. Oitenta raízes de caninos foram submetidas ao preparo biomecânico e distribuídas em 2 grupos de acordo com a secagem, previamente a obturação: I- Secagem cone de papel absorvente e II- Secagem com álcool isopropílico 70%,e posteriormente distribuídas em 8 grupos (n=10): IA e IIA cimento AH Plus; IB e IIB - cimento Hybrid Root Seal; IC e IIC- cimento Epiphany SE com guta percha e ID e IID cimento Epiphany SE com Resilon. Após a obturação, 80 raízes foram seccionadas transversalmente obtendo-se 3 slices de 1,0 mm de espessura para cada terço radicular. Um slice de cada terço foi submetido ao teste de push out e tipo de falha analisado por meio de lupa estereoscópica. Os dois slices restantes foram submetidos à MEV para análise da interface adesiva e superfície do material obturador. A análise de variância evidenciou haver diferença estatisticamente significante (p<0,05) entre os materiais obturadores, o protocolo de secagem do canal radicular e a interação destes fatores. AH Plus/ guta percha obteve os maiores valores médios de resistência de união (3,83 ± 0,45 MPa), sendo estatisticamente diferente (p<0,05) dos demais. O Hybrid Root SEAL/ guta percha (3,24 ± 0,46 MPa) obteve valores intermediários, sendo estatisticamente diferente dos demais (p<0,05). O cimento obturador Epiphany SE quando associado à guta percha (0,45 ± 0,10 MPa) ou ao Resilon (0,31 ± 0,09 MPa) obteve os menores valores de adesividade, sendo estatisticamente semelhantes entre si (p>0,05) e diferentes dos demais (p<0,05). O cimento AH Plus obteve os maiores valores de adesividade independente do protocolo de secagem utilizado. Na comparação entre os protocolos, o protocolo que utilizou álcool isopropílico 70% obteve maiores valores médios de adesividade. / The purpose of the present study was to evaluate the influence of the drying protocol with isopropyl alcohol on the adhesion of the sealers AH Plus, Hybrid Root Seal and Epiphany SE to intraradicular dentin. Eighty root canals of canines were subjected to biomechanical preparation and were allocated to receive one of the following drying protocols (n=40) prior to root canal filling: I- Drying with absorbent paper point and II- Drying with 70% isopropyl alcohol. Thereafter, 8 groups (n=10) were formed according to the filling material: IA and IIA AH Plus sealer; IB and IIB - Hybrid Root Seal sealer; IC and IIC- Epiphany SE sealer with gutta-percha; and ID and IID Epiphany SE sealer with Resilon. After filling, the 80 roots were sectioned transversally to obtain three 1.0-mm-thick slices from each root third. The first slice of each third was subjected to a push-out test and the failure mode was determined with a stereoscopic lens. The other two slices were prepared for SEM to examine adhesive interface and the surface of the filling materials. Analysis of variance revealed statistically significant difference (p<0.05) among the filling materials, between the root canal drying protocols as well as for the interaction of these factors. AH Plus/gutta-percha had significantly higher (p<0.05) bond strengths (3.83 ± 0.45 MPa) than the other materials. Hybrid Root SEAL/gutta-percha (3.24 ± 0.46 MPa) had intermediate values and differed significantly from the other materials (p<0.05). Epiphany SE combined with either gutta-percha (0.45 ± 0.10 MPa) or Resilon (0.31 ± 0.09 MPa) presented the lowest bond strengths without statistically significant difference (p>0.05) from each other, but with significant difference (p<0.05) from the other materials. AH Plus present the highest bond strengths regardless of the drying protocol. Comparing the two protocols, drying of root canals with 70% isopropyl alcohol was associated with the highest bond strength values to intraradicular dentin.
10

Infiltração bacteriana em canais radiculares obturados com diferentes cimentos endodônticos e duas técnicas obturadoras / Bacterial leakage in root canals filled with different endodontic sealers and two techniques

Thais Vieira Rizzo Nunes da Cunha 27 June 2011 (has links)
O objetivo deste estudo foi avaliar ex vivo a infiltração do Enterococcus faecalis em canais radiculares obturados com os cimentos endodônticos AHPlus, RealSeal e o cimento experimental Sealepox, pelas técnicas da condensação lateral e compactação vertical. Cem dentes humanos unirradiculados, com canais únicos e retos, tiveram os mesmos instrumentados, e após, as coroas removidas, para a realização das obturações. Aparatos específicos para a fixação das raízes foram confeccionados contendo meio de cultura estéril e específico para a bactéria, em questão. A inoculação deEnterococcus faecalis foi realizada e, durante 60 dias, o meio de cultura foi checado diariamente para constatar sua possível turvação, o que, caracterizaria a passagem bacteriana pela obturação. Todos os espécimes foram processados histologicamente e corados pela técnica de Brown e Brenn para exame em microscópio óptico, para constatação da presença e localização do Enteroccocus faecalis no interior dos canais radiculares e na massa dentinária. Considerando a metodologia da infiltração bacteriana, os resultados obtidos mostraram que nem os cimentos obturadores e nem as técnicas foram capazes de impedir a infiltração. Contudo, a mesma ocorreu em um pequeno número de espécimes, não sendo observadas diferenças significantes entre os cimentos e técnicas. Em relação à análise microscópica, foi observada a presença dos micro-organismos em, praticamente, todos os espécimes analisados. Tal observação permite afirmar que a metodologia da infiltração bacteriana não é confiável para se qualificar o selamento proporcionado por obturações de canais radiculares. / The aim of this study was to assess ex-vivo the leakage of Enterococcus faecalis in root canals filled with endodontic sealers AHPlus, RealSeal and the experimental sealer Sealepox, after the lateral condensation or warm vertical condensation techniques. One hundred single rooted extracted human teeth had their root canals instrumented and their crowns removed for the conducting of the obturation. An experimental bacterial leakage setup was designed for fixing the root canal in the contained media, sterile and specific for the bacteria in study. The inoculation with Enterococcus faecalis was conducted and for 60 days the media was checked daily for possible change in its clear aspect, which would than, characterize the contamination by the bacteria through the root canal. All the sample which were infiltrated, totally or not, were processed and colored by the Brown and Brenn technique for observation of presence and location of Enterococcus faecalis in the root canal or dentinal tubules. With the methodology for bacterial leakage considered, the results obtained showed that none of the sealer neither the techniques employed were able to avoid leakages. Nevertheless, leakage happened in a small number of samples, where no statistical difference could be found between sealers and techniques. In regards to the microscopy analysis, presence of microorganisms was observed in practically all the samples. Such an observation, suggests that bacterial leakage is not a trustworthy indicator for qualifying sealing obtained by sealers in root canals.

Page generated in 0.4814 seconds