• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise da remoção da smear layer e penetração intratubular do cimento obturador após diferentes protocolos de irrigação - estudo em microscopia eletrônica de varredura e confocal a laser / Analysis of smear layer removal and tubular dentine sealer penetration after different irrigation protocols - a study performed by scanning electron and laser confocal microscopy

Machado, Ricardo 23 April 2015 (has links)
O objetivo do presente estudo foi avaliar a remoção da smear layer e a penetração intratubular do cimento obturador AH Plus utilizando diferentes protocolos de irrigação. Após aprovação do Comitê de Ética em Pesquisa da Faculdade de Odontologia de Ribeirão Preto - FORP/USP, noventa incisivos centrais superiores foram selecionados e fornecidos pelo banco de dentes da mesma instituição. Estes foram radiografados no sentido mésio - distal e vestíbulo - lingual para comprovar a presença de canais únicos, sem curvaturas abruptas, reabsorções ou tratamentos endodônticos prévios. Após a remoção da porção coronal para a obtenção de raízes com comprimentos padronizados de 15 milímetros, os diâmetros anatômicos foram determinados e as instrumentações realizadas por meio da técnica coroa ápice estabelecendo os diâmetros cirúrgicos utilizando 3 instrumentos acima dos anatômicos. Durante este processo, os espécimes foram divididos em seis grupos de acordo com os protocolos de irrigação: Grupo 1 (controle - n. 15) - 2,5ml de água destilada a cada troca de instrumentos e 2,5ml de água destilada por 3 minutos ao final da instrumentação; Grupo 2 (n. 15) - 2,5ml de hipoclorito de sódio a 2,5% a cada troca de instrumentos e 2,5ml de hipoclorito de sódio a 2,5% por 3 minutos ao final da instrumentação; Grupo 3 (n. 15) - 2,5ml de hipoclorito de sódio a 2,5% a cada troca de instrumentos e 2,5ml de EDTA a 17% por 3 minutos ao final da instrumentação; Grupo 4 (n. 15) - 2,5ml de hipoclorito de sódio a 2,5% e 2,5ml de EDTA a 17% a cada troca de instrumentos + 2,5ml de EDTA a 17% por 3 minutos ao final da instrumentação; Grupo 5 (n. 15) - 2,5ml de hipoclorito de sódio a 2,5% a cada troca de instrumentos e 2,5ml de ácido cítrico a 10% por 3 minutos ao final da instrumentação; Grupo 6 (n. 15) - 2,5ml de hipoclorito de sódio a 2,5% e 2,5ml de ácido cítrico a 10% a cada troca de instrumentos + 2,5ml de ácido cítrico a 10% por 3 minutos ao final da instrumentação. Após esta fase, cinco espécimes de cada grupo foram clivados no sentido mésio - distal para avaliação da remoção da smear layer em microscopia eletrônica de varredura por meio da análise de 3 imagens de cada terço em aumentos de 300, 1000 e 2000 vezes. Esta variável foi determinada por um score qualitativo estabelecido pelo consenso de 3 avaliadores calibrados. Os demais espécimes foram obturados pela técnica de condensação lateral com cones principais correspondentes ao último instrumento associados ao cimento AH Plus corado com Rodamina B, cones acessórios B8 e mantidos em ambiente com 100% de umidade por 7 dias. Em seguida, os espécimes foram seccionados transversalmente para obtenção de slices de aproximadamente 2mm de espessura em cada terço (cervical, médio e apical) e as faces cervicais submetidas a um tratamento metalográfico para análise da penetração intratubular do cimento obturador em microscopia confocal a laser. Os melhores índices de remoção de smear layer e as maiores porcentagens de penetração intratubular do cimento foram obtidos pelos grupos onde as soluções quelantes foram utilizadas (G3, G4, G5 e G6) com diferenças estatisticamente significantes (p<0,05) em relação aos grupos onde utilizou - se somente a água destilada (G1) e o hipoclorito de sódio a 2,5% (G2) durante o processo de instrumentação. Não foram observadas vantagens em relação ao uso associado do EDTA a 17% e do ácido cítrico a 10% ao hipoclorito de sódio pela ausência de diferenças estatísticas significantes entre os grupos 3 e 4 e 5 e 6, respectivamente. / The aim of this study was to evaluate the smear layer removal and tubular dentine sealer penetration of AH Plus after different irrigation protocols. After approval of the study by the Ethics Committee of the Ribeirão Preto Dental School - FORP/USP, ninety maxillary central incisors were selected and supplied by the tooth bank of the same institution. The teeth were radiographed in the mesiodistal and buccolingual directions to verify the presence of single canals, without abrupt curvatures, resorption or previous endodontic treatment. The coronal portion was removed and roots lengths were standardized at 15 mm. The anatomic diameters were then determined and instrumentations were carried out by the crown-down technique, using 3 higher-diameter instruments to establish the surgical diameters. During this process, the specimens were divided into six groups, according to the following irrigation protocols: Group 1 (control - n. 15) - 2.5ml of distilled water at each change of instruments + 2.5ml of distilled water for 3 minutes at the end of the instrumentation; Group 2 (n. 15) - 2.5ml of 2.5% sodium hypochlorite at each change of instruments + 2.5 ml of 2.5% sodium hypochlorite for 3 minutes at the end of the instrumentation; Group 3 (n. 15) - 2.5ml of 2.5% sodium hypochlorite at each change of instruments + 2.5ml of 17% EDTA for 3 minutes at the end of the instrumentation; Group 4 (n. 15) - 2.5ml of 2.5% sodium hypochlorite and 2.5ml of 17% EDTA at each change of instruments + 2.5ml of 17% EDTA for 3 minutes at the end of the instrumentation; Group 5 (n. 15) - 2.5ml of 2.5% sodium hypochlorite at each change of instruments + 2.5ml of 10% citric acid for 3 minutes at the end of the instrumentation; Group 6 (n. 15) - 2.5ml of 2.5% sodium hypochlorite and 2.5 ml of 10% citric acid at each change of instruments + 2.5 ml of 10% citric acid for 3 minutes at the end of the instrumentation. Following this phase, five specimens from each group were cleaved in the mesiodistal direction to evaluate the smear layer removal by scanning electron microscopy. Evaluation was performed by analyzing 3 images of each third at 300, 1000 and 2000X. This variable was determined by a qualitative score established by the consensus of 3 calibrated examiners. The remaining specimens were filled using lateral condensation with AH Plus sealer labeled with Rhodamine B and kept in an environment with 100% humidity for 7 days. Then, the specimens were sectioned to obtain approximately 2 mm thick slices of each third (cervical, middle and apical). The cervical surfaces were subjected to metallographic treatment for analysis of the tubular dentine sealer penetration by confocal laser microscopy. The highest smear layer removal rates and tubular dentine sealer penetration percentages were obtained by the groups that used chelating solutions (G3, G4, G5 and G6). These showed statistically significant differences (p<0.05) compared with the groups that used just distilled water (G1) and 2.5% sodium hypochlorite (G2) during instrumentation. No benefits were observed for the combined use of 17% EDTA or 10% citric acid with 2.5% sodium hypochlorite, considering that there were no statistically significant differences between groups 3 and 4, and between 5 and 6, respectively.
2

Análise da remoção da smear layer e penetração intratubular do cimento obturador após diferentes protocolos de irrigação - estudo em microscopia eletrônica de varredura e confocal a laser / Analysis of smear layer removal and tubular dentine sealer penetration after different irrigation protocols - a study performed by scanning electron and laser confocal microscopy

Ricardo Machado 23 April 2015 (has links)
O objetivo do presente estudo foi avaliar a remoção da smear layer e a penetração intratubular do cimento obturador AH Plus utilizando diferentes protocolos de irrigação. Após aprovação do Comitê de Ética em Pesquisa da Faculdade de Odontologia de Ribeirão Preto - FORP/USP, noventa incisivos centrais superiores foram selecionados e fornecidos pelo banco de dentes da mesma instituição. Estes foram radiografados no sentido mésio - distal e vestíbulo - lingual para comprovar a presença de canais únicos, sem curvaturas abruptas, reabsorções ou tratamentos endodônticos prévios. Após a remoção da porção coronal para a obtenção de raízes com comprimentos padronizados de 15 milímetros, os diâmetros anatômicos foram determinados e as instrumentações realizadas por meio da técnica coroa ápice estabelecendo os diâmetros cirúrgicos utilizando 3 instrumentos acima dos anatômicos. Durante este processo, os espécimes foram divididos em seis grupos de acordo com os protocolos de irrigação: Grupo 1 (controle - n. 15) - 2,5ml de água destilada a cada troca de instrumentos e 2,5ml de água destilada por 3 minutos ao final da instrumentação; Grupo 2 (n. 15) - 2,5ml de hipoclorito de sódio a 2,5% a cada troca de instrumentos e 2,5ml de hipoclorito de sódio a 2,5% por 3 minutos ao final da instrumentação; Grupo 3 (n. 15) - 2,5ml de hipoclorito de sódio a 2,5% a cada troca de instrumentos e 2,5ml de EDTA a 17% por 3 minutos ao final da instrumentação; Grupo 4 (n. 15) - 2,5ml de hipoclorito de sódio a 2,5% e 2,5ml de EDTA a 17% a cada troca de instrumentos + 2,5ml de EDTA a 17% por 3 minutos ao final da instrumentação; Grupo 5 (n. 15) - 2,5ml de hipoclorito de sódio a 2,5% a cada troca de instrumentos e 2,5ml de ácido cítrico a 10% por 3 minutos ao final da instrumentação; Grupo 6 (n. 15) - 2,5ml de hipoclorito de sódio a 2,5% e 2,5ml de ácido cítrico a 10% a cada troca de instrumentos + 2,5ml de ácido cítrico a 10% por 3 minutos ao final da instrumentação. Após esta fase, cinco espécimes de cada grupo foram clivados no sentido mésio - distal para avaliação da remoção da smear layer em microscopia eletrônica de varredura por meio da análise de 3 imagens de cada terço em aumentos de 300, 1000 e 2000 vezes. Esta variável foi determinada por um score qualitativo estabelecido pelo consenso de 3 avaliadores calibrados. Os demais espécimes foram obturados pela técnica de condensação lateral com cones principais correspondentes ao último instrumento associados ao cimento AH Plus corado com Rodamina B, cones acessórios B8 e mantidos em ambiente com 100% de umidade por 7 dias. Em seguida, os espécimes foram seccionados transversalmente para obtenção de slices de aproximadamente 2mm de espessura em cada terço (cervical, médio e apical) e as faces cervicais submetidas a um tratamento metalográfico para análise da penetração intratubular do cimento obturador em microscopia confocal a laser. Os melhores índices de remoção de smear layer e as maiores porcentagens de penetração intratubular do cimento foram obtidos pelos grupos onde as soluções quelantes foram utilizadas (G3, G4, G5 e G6) com diferenças estatisticamente significantes (p<0,05) em relação aos grupos onde utilizou - se somente a água destilada (G1) e o hipoclorito de sódio a 2,5% (G2) durante o processo de instrumentação. Não foram observadas vantagens em relação ao uso associado do EDTA a 17% e do ácido cítrico a 10% ao hipoclorito de sódio pela ausência de diferenças estatísticas significantes entre os grupos 3 e 4 e 5 e 6, respectivamente. / The aim of this study was to evaluate the smear layer removal and tubular dentine sealer penetration of AH Plus after different irrigation protocols. After approval of the study by the Ethics Committee of the Ribeirão Preto Dental School - FORP/USP, ninety maxillary central incisors were selected and supplied by the tooth bank of the same institution. The teeth were radiographed in the mesiodistal and buccolingual directions to verify the presence of single canals, without abrupt curvatures, resorption or previous endodontic treatment. The coronal portion was removed and roots lengths were standardized at 15 mm. The anatomic diameters were then determined and instrumentations were carried out by the crown-down technique, using 3 higher-diameter instruments to establish the surgical diameters. During this process, the specimens were divided into six groups, according to the following irrigation protocols: Group 1 (control - n. 15) - 2.5ml of distilled water at each change of instruments + 2.5ml of distilled water for 3 minutes at the end of the instrumentation; Group 2 (n. 15) - 2.5ml of 2.5% sodium hypochlorite at each change of instruments + 2.5 ml of 2.5% sodium hypochlorite for 3 minutes at the end of the instrumentation; Group 3 (n. 15) - 2.5ml of 2.5% sodium hypochlorite at each change of instruments + 2.5ml of 17% EDTA for 3 minutes at the end of the instrumentation; Group 4 (n. 15) - 2.5ml of 2.5% sodium hypochlorite and 2.5ml of 17% EDTA at each change of instruments + 2.5ml of 17% EDTA for 3 minutes at the end of the instrumentation; Group 5 (n. 15) - 2.5ml of 2.5% sodium hypochlorite at each change of instruments + 2.5ml of 10% citric acid for 3 minutes at the end of the instrumentation; Group 6 (n. 15) - 2.5ml of 2.5% sodium hypochlorite and 2.5 ml of 10% citric acid at each change of instruments + 2.5 ml of 10% citric acid for 3 minutes at the end of the instrumentation. Following this phase, five specimens from each group were cleaved in the mesiodistal direction to evaluate the smear layer removal by scanning electron microscopy. Evaluation was performed by analyzing 3 images of each third at 300, 1000 and 2000X. This variable was determined by a qualitative score established by the consensus of 3 calibrated examiners. The remaining specimens were filled using lateral condensation with AH Plus sealer labeled with Rhodamine B and kept in an environment with 100% humidity for 7 days. Then, the specimens were sectioned to obtain approximately 2 mm thick slices of each third (cervical, middle and apical). The cervical surfaces were subjected to metallographic treatment for analysis of the tubular dentine sealer penetration by confocal laser microscopy. The highest smear layer removal rates and tubular dentine sealer penetration percentages were obtained by the groups that used chelating solutions (G3, G4, G5 and G6). These showed statistically significant differences (p<0.05) compared with the groups that used just distilled water (G1) and 2.5% sodium hypochlorite (G2) during instrumentation. No benefits were observed for the combined use of 17% EDTA or 10% citric acid with 2.5% sodium hypochlorite, considering that there were no statistically significant differences between groups 3 and 4, and between 5 and 6, respectively.
3

Estudo da biocompatibilidade do cimento de aluminato de cálcio para uso odontológico, avaliação do pH, liberação de íons cálcio e atividade antimicrobiana / Biocompatibility of calcium aluminate cement for dental use, evaluation of pH, calcium ion release and antimicrobial activity

Aguilar, Fabiano Gamero 20 April 2012 (has links)
O objetivo desse estudo foi avaliar o pH, a liberação de íons cálcio, a atividade antimicrobiana in vitro de cimento de aluminato de cálcio (EndoBinder) com diferentes radiopacificadores (óxido de bismuto, óxido de zinco e óxido de zircônia) e a biocompatibilidade do cimento acrescido de óxido de bismuto como agente radiopacificador, em comparação ao mineral trióxido agregado (MTA). Para a avaliação do pH e a liberação de íons cálcio, 25 amostras (n=5) de 2,0 x 10 mm foram obtidas de EndoBinder Puro (EBP), EndoBinder com Óxido de Bismuto (EBOB), EndoBinder com Óxido de Zinco (EBOZn), EndoBinder com Óxido de Zircônia (EBOZr) e Mineral Trióxido Agregado (MTA), que foram imersas em 10 ml água destilada e deionizada (pH=6,9). Após 2, 4, 12, 24, 48 horas, 7, 14 e 28 dias, foi medido o pH e a quantidade de íons cálcio da água onde as amostras foram imersas. Para a determinação in vitro da atividade antimicrobiana dos cimentos (EBP, EBOB, EBOZN, EBOZr e MTA), foram obtidas 15 amostras de cada material (n=3) de 5,0 x 5,0 mm colocadas em contato com 5 tipos de microrganismos: Escherichia coli (ATCC 25922), Enterococcus faecalis (ATCC 29212), Staphylococcus aureus (ATCC 25923), Candida albicans (ATCC 10231) e a Candida glabrata (ATCC 2001) em placas de petri com Agar (Muller Hinton e Sabouraud Dextrose) deixadas em temperatura ambiente por 2 horas para a pré-difusão e depois incubadas a 37°C por 24 horas. Utilizou-se uma régua milimetrada com precisão de 0,5 mm para realizar as medidas dos halos de inibição em torno dos corpos de prova. A biocompatibilidade dos materiais foi avaliada a partir da implantação de tubos de polietileno em tecido subcutâneo de 15 ratos machos, sendo 1 implante escapular e 1 pélvico, num total de 2 tubos por animal (n=5). Como controle, foi utilizada a lateral do tubo de polietileno. Após 7, 21 e 42 dias os animais foram sacrificados e os tecidos processados para a obtenção dos cortes histológicos e posterior análise histopatológica. Os resultados do ensaio de pH, liberação de cálcio e de atividade microbiológica foram submetidos à análise estatística (2-way ANOVA, Bonferroni, p<0,05). Os resultados de biocompatibilidade foram classificados quanto à severidade da reação inflamatória e quantificados em relação aos eventos presentes nas áreas pré-determinadas. Ao final de 28 dias não houve diferença estatística (p>0,05) entre nenhum grupo, tanto para o pH quanto para a liberação de íons cálcio. MTA, EBP e EBOB apresentaram atividade antimicrobiana quando em contato com todos os microrganismos, e EBOZr e EBOZn apenas quando em contato com Staphylococcus aureus e Candida glabrata. A reação inflamatória observada com os implantes subcultâneos diminuiu no decorrer do período de análise, porém ao final de 42 dias MTA ainda apresentou uma discreta reação inflamatória, situação não encontrada com o EB. Desta forma, concluiu-se que EB apresentou propriedades químicas e biológicas semelhantes ao MTA, além de apresentar menor reação tecidual, sendo biocompatível quando testado em tecido subcutâneo de ratos. / The purpose of this study was to evaluate the pH, calcium ion release, in vitro antimicrobial activity of a calcium aluminate cement (EndoBinder) with different radiopacifiers (bismuth oxide, zinc oxide, or zirconium oxide) and the biocompatibility of calcium aluminate cement with bismuth oxide radiopacifier in comparison with the mineral trioxide aggregate (MTA). For the evaluation of pH and calcium ion release 25 sample (n=5) measuring 2,0 x 10 mm were obtained from EndoBinder Pure (EBP), EndoBinder with bismuth oxide (EBOB), EndoBinder with zinc oxide (EBOZn), EndoBinder with zirconium oxide (EBOZr) and mineral trioxide aggregate (MTA) wich were immersed in a flask containing 10 ml of deionized and distilled water (pH=6,9). After 2, 4, 12, 24, 48 hours and 7, 14, 28 days, meassurements of the pH and calcium ion release from the water where the samples were immersed were assessed. To determine the in vitro antimicrobial activity of the cements (EBP, EBOB, EBOZN, EBOZr and MTA) 15 samples of each material (n=3) measuring 5,0 x 5,0 mm were placed in contact with five types of microorganisms: Escherichia coli (ATCC 25922), Enterococcus faecalis (ATCC 29212), Staphylococcus aureus (ATCC 25923), Candida albicans (ATCC 10231) e a Candida glabrata (ATCC 2001) .The MullerHinton agar (MH) diffusion method was employed and the plates were kept at room temperature for 2 hours for pre diffusion and then incubated at 37 C° for 24 hours. Zones of inhibition around the specimens were measured using a 0.5mm precision millimeter ruler. The biocompatibility of the test materials was evaluated from the implantation of 2 polyethylene tubes in the subcutaneous tissue of 15 male rats (n=5), 1 being scapular (EBOB) and 1 pelvic (MTA). The external tube wall was considered as the control group. After 7, 21 and 42 days animals were sacrificed, obtaining 5 tissue samples per group at each time interval of analysis then histological analysis was performed. The test results for pH, calcium ion release and in vitro antimicrobial activity were submitted to statistical analysis (two-way ANOVA, Bonferroni, p <0.05). The results of biocompatibility were classified according to severity of inflammatory reaction and quantified in relation to present events in pre-determined areas. After 28 days there was no statistical difference (p> 0.05) between any group for both the pH and calcium ions release. MTA, EBP and EBOB showed antimicrobial activity against all microorganisms and EBOZr and EBOZn only against Staphylococcus aureus and Candida glabrata. The inflammatory reaction observed with subcutaneous implants decreased during the period of analysis however, after 42 days MTA still had a discrete inflammatory reaction, this situation was not found with EBOB. Thus, it was concluded that EB has been shown to have similar biological and chemical properties compared with MTA, it also showed less tissue reaction and biocompatibility when tested in rat subcutaneous tissue.
4

Estudo da biocompatibilidade do cimento de aluminato de cálcio para uso odontológico, avaliação do pH, liberação de íons cálcio e atividade antimicrobiana / Biocompatibility of calcium aluminate cement for dental use, evaluation of pH, calcium ion release and antimicrobial activity

Fabiano Gamero Aguilar 20 April 2012 (has links)
O objetivo desse estudo foi avaliar o pH, a liberação de íons cálcio, a atividade antimicrobiana in vitro de cimento de aluminato de cálcio (EndoBinder) com diferentes radiopacificadores (óxido de bismuto, óxido de zinco e óxido de zircônia) e a biocompatibilidade do cimento acrescido de óxido de bismuto como agente radiopacificador, em comparação ao mineral trióxido agregado (MTA). Para a avaliação do pH e a liberação de íons cálcio, 25 amostras (n=5) de 2,0 x 10 mm foram obtidas de EndoBinder Puro (EBP), EndoBinder com Óxido de Bismuto (EBOB), EndoBinder com Óxido de Zinco (EBOZn), EndoBinder com Óxido de Zircônia (EBOZr) e Mineral Trióxido Agregado (MTA), que foram imersas em 10 ml água destilada e deionizada (pH=6,9). Após 2, 4, 12, 24, 48 horas, 7, 14 e 28 dias, foi medido o pH e a quantidade de íons cálcio da água onde as amostras foram imersas. Para a determinação in vitro da atividade antimicrobiana dos cimentos (EBP, EBOB, EBOZN, EBOZr e MTA), foram obtidas 15 amostras de cada material (n=3) de 5,0 x 5,0 mm colocadas em contato com 5 tipos de microrganismos: Escherichia coli (ATCC 25922), Enterococcus faecalis (ATCC 29212), Staphylococcus aureus (ATCC 25923), Candida albicans (ATCC 10231) e a Candida glabrata (ATCC 2001) em placas de petri com Agar (Muller Hinton e Sabouraud Dextrose) deixadas em temperatura ambiente por 2 horas para a pré-difusão e depois incubadas a 37°C por 24 horas. Utilizou-se uma régua milimetrada com precisão de 0,5 mm para realizar as medidas dos halos de inibição em torno dos corpos de prova. A biocompatibilidade dos materiais foi avaliada a partir da implantação de tubos de polietileno em tecido subcutâneo de 15 ratos machos, sendo 1 implante escapular e 1 pélvico, num total de 2 tubos por animal (n=5). Como controle, foi utilizada a lateral do tubo de polietileno. Após 7, 21 e 42 dias os animais foram sacrificados e os tecidos processados para a obtenção dos cortes histológicos e posterior análise histopatológica. Os resultados do ensaio de pH, liberação de cálcio e de atividade microbiológica foram submetidos à análise estatística (2-way ANOVA, Bonferroni, p<0,05). Os resultados de biocompatibilidade foram classificados quanto à severidade da reação inflamatória e quantificados em relação aos eventos presentes nas áreas pré-determinadas. Ao final de 28 dias não houve diferença estatística (p>0,05) entre nenhum grupo, tanto para o pH quanto para a liberação de íons cálcio. MTA, EBP e EBOB apresentaram atividade antimicrobiana quando em contato com todos os microrganismos, e EBOZr e EBOZn apenas quando em contato com Staphylococcus aureus e Candida glabrata. A reação inflamatória observada com os implantes subcultâneos diminuiu no decorrer do período de análise, porém ao final de 42 dias MTA ainda apresentou uma discreta reação inflamatória, situação não encontrada com o EB. Desta forma, concluiu-se que EB apresentou propriedades químicas e biológicas semelhantes ao MTA, além de apresentar menor reação tecidual, sendo biocompatível quando testado em tecido subcutâneo de ratos. / The purpose of this study was to evaluate the pH, calcium ion release, in vitro antimicrobial activity of a calcium aluminate cement (EndoBinder) with different radiopacifiers (bismuth oxide, zinc oxide, or zirconium oxide) and the biocompatibility of calcium aluminate cement with bismuth oxide radiopacifier in comparison with the mineral trioxide aggregate (MTA). For the evaluation of pH and calcium ion release 25 sample (n=5) measuring 2,0 x 10 mm were obtained from EndoBinder Pure (EBP), EndoBinder with bismuth oxide (EBOB), EndoBinder with zinc oxide (EBOZn), EndoBinder with zirconium oxide (EBOZr) and mineral trioxide aggregate (MTA) wich were immersed in a flask containing 10 ml of deionized and distilled water (pH=6,9). After 2, 4, 12, 24, 48 hours and 7, 14, 28 days, meassurements of the pH and calcium ion release from the water where the samples were immersed were assessed. To determine the in vitro antimicrobial activity of the cements (EBP, EBOB, EBOZN, EBOZr and MTA) 15 samples of each material (n=3) measuring 5,0 x 5,0 mm were placed in contact with five types of microorganisms: Escherichia coli (ATCC 25922), Enterococcus faecalis (ATCC 29212), Staphylococcus aureus (ATCC 25923), Candida albicans (ATCC 10231) e a Candida glabrata (ATCC 2001) .The MullerHinton agar (MH) diffusion method was employed and the plates were kept at room temperature for 2 hours for pre diffusion and then incubated at 37 C° for 24 hours. Zones of inhibition around the specimens were measured using a 0.5mm precision millimeter ruler. The biocompatibility of the test materials was evaluated from the implantation of 2 polyethylene tubes in the subcutaneous tissue of 15 male rats (n=5), 1 being scapular (EBOB) and 1 pelvic (MTA). The external tube wall was considered as the control group. After 7, 21 and 42 days animals were sacrificed, obtaining 5 tissue samples per group at each time interval of analysis then histological analysis was performed. The test results for pH, calcium ion release and in vitro antimicrobial activity were submitted to statistical analysis (two-way ANOVA, Bonferroni, p <0.05). The results of biocompatibility were classified according to severity of inflammatory reaction and quantified in relation to present events in pre-determined areas. After 28 days there was no statistical difference (p> 0.05) between any group for both the pH and calcium ions release. MTA, EBP and EBOB showed antimicrobial activity against all microorganisms and EBOZr and EBOZn only against Staphylococcus aureus and Candida glabrata. The inflammatory reaction observed with subcutaneous implants decreased during the period of analysis however, after 42 days MTA still had a discrete inflammatory reaction, this situation was not found with EBOB. Thus, it was concluded that EB has been shown to have similar biological and chemical properties compared with MTA, it also showed less tissue reaction and biocompatibility when tested in rat subcutaneous tissue.

Page generated in 0.0913 seconds