Spelling suggestions: "subject:"liberação dde ions cálcio"" "subject:"liberação dde bons cálcio""
1 |
Estudo da biocompatibilidade do cimento de aluminato de cálcio para uso odontológico, avaliação do pH, liberação de íons cálcio e atividade antimicrobiana / Biocompatibility of calcium aluminate cement for dental use, evaluation of pH, calcium ion release and antimicrobial activityAguilar, Fabiano Gamero 20 April 2012 (has links)
O objetivo desse estudo foi avaliar o pH, a liberação de íons cálcio, a atividade antimicrobiana in vitro de cimento de aluminato de cálcio (EndoBinder) com diferentes radiopacificadores (óxido de bismuto, óxido de zinco e óxido de zircônia) e a biocompatibilidade do cimento acrescido de óxido de bismuto como agente radiopacificador, em comparação ao mineral trióxido agregado (MTA). Para a avaliação do pH e a liberação de íons cálcio, 25 amostras (n=5) de 2,0 x 10 mm foram obtidas de EndoBinder Puro (EBP), EndoBinder com Óxido de Bismuto (EBOB), EndoBinder com Óxido de Zinco (EBOZn), EndoBinder com Óxido de Zircônia (EBOZr) e Mineral Trióxido Agregado (MTA), que foram imersas em 10 ml água destilada e deionizada (pH=6,9). Após 2, 4, 12, 24, 48 horas, 7, 14 e 28 dias, foi medido o pH e a quantidade de íons cálcio da água onde as amostras foram imersas. Para a determinação in vitro da atividade antimicrobiana dos cimentos (EBP, EBOB, EBOZN, EBOZr e MTA), foram obtidas 15 amostras de cada material (n=3) de 5,0 x 5,0 mm colocadas em contato com 5 tipos de microrganismos: Escherichia coli (ATCC 25922), Enterococcus faecalis (ATCC 29212), Staphylococcus aureus (ATCC 25923), Candida albicans (ATCC 10231) e a Candida glabrata (ATCC 2001) em placas de petri com Agar (Muller Hinton e Sabouraud Dextrose) deixadas em temperatura ambiente por 2 horas para a pré-difusão e depois incubadas a 37°C por 24 horas. Utilizou-se uma régua milimetrada com precisão de 0,5 mm para realizar as medidas dos halos de inibição em torno dos corpos de prova. A biocompatibilidade dos materiais foi avaliada a partir da implantação de tubos de polietileno em tecido subcutâneo de 15 ratos machos, sendo 1 implante escapular e 1 pélvico, num total de 2 tubos por animal (n=5). Como controle, foi utilizada a lateral do tubo de polietileno. Após 7, 21 e 42 dias os animais foram sacrificados e os tecidos processados para a obtenção dos cortes histológicos e posterior análise histopatológica. Os resultados do ensaio de pH, liberação de cálcio e de atividade microbiológica foram submetidos à análise estatística (2-way ANOVA, Bonferroni, p<0,05). Os resultados de biocompatibilidade foram classificados quanto à severidade da reação inflamatória e quantificados em relação aos eventos presentes nas áreas pré-determinadas. Ao final de 28 dias não houve diferença estatística (p>0,05) entre nenhum grupo, tanto para o pH quanto para a liberação de íons cálcio. MTA, EBP e EBOB apresentaram atividade antimicrobiana quando em contato com todos os microrganismos, e EBOZr e EBOZn apenas quando em contato com Staphylococcus aureus e Candida glabrata. A reação inflamatória observada com os implantes subcultâneos diminuiu no decorrer do período de análise, porém ao final de 42 dias MTA ainda apresentou uma discreta reação inflamatória, situação não encontrada com o EB. Desta forma, concluiu-se que EB apresentou propriedades químicas e biológicas semelhantes ao MTA, além de apresentar menor reação tecidual, sendo biocompatível quando testado em tecido subcutâneo de ratos. / The purpose of this study was to evaluate the pH, calcium ion release, in vitro antimicrobial activity of a calcium aluminate cement (EndoBinder) with different radiopacifiers (bismuth oxide, zinc oxide, or zirconium oxide) and the biocompatibility of calcium aluminate cement with bismuth oxide radiopacifier in comparison with the mineral trioxide aggregate (MTA). For the evaluation of pH and calcium ion release 25 sample (n=5) measuring 2,0 x 10 mm were obtained from EndoBinder Pure (EBP), EndoBinder with bismuth oxide (EBOB), EndoBinder with zinc oxide (EBOZn), EndoBinder with zirconium oxide (EBOZr) and mineral trioxide aggregate (MTA) wich were immersed in a flask containing 10 ml of deionized and distilled water (pH=6,9). After 2, 4, 12, 24, 48 hours and 7, 14, 28 days, meassurements of the pH and calcium ion release from the water where the samples were immersed were assessed. To determine the in vitro antimicrobial activity of the cements (EBP, EBOB, EBOZN, EBOZr and MTA) 15 samples of each material (n=3) measuring 5,0 x 5,0 mm were placed in contact with five types of microorganisms: Escherichia coli (ATCC 25922), Enterococcus faecalis (ATCC 29212), Staphylococcus aureus (ATCC 25923), Candida albicans (ATCC 10231) e a Candida glabrata (ATCC 2001) .The MullerHinton agar (MH) diffusion method was employed and the plates were kept at room temperature for 2 hours for pre diffusion and then incubated at 37 C° for 24 hours. Zones of inhibition around the specimens were measured using a 0.5mm precision millimeter ruler. The biocompatibility of the test materials was evaluated from the implantation of 2 polyethylene tubes in the subcutaneous tissue of 15 male rats (n=5), 1 being scapular (EBOB) and 1 pelvic (MTA). The external tube wall was considered as the control group. After 7, 21 and 42 days animals were sacrificed, obtaining 5 tissue samples per group at each time interval of analysis then histological analysis was performed. The test results for pH, calcium ion release and in vitro antimicrobial activity were submitted to statistical analysis (two-way ANOVA, Bonferroni, p <0.05). The results of biocompatibility were classified according to severity of inflammatory reaction and quantified in relation to present events in pre-determined areas. After 28 days there was no statistical difference (p> 0.05) between any group for both the pH and calcium ions release. MTA, EBP and EBOB showed antimicrobial activity against all microorganisms and EBOZr and EBOZn only against Staphylococcus aureus and Candida glabrata. The inflammatory reaction observed with subcutaneous implants decreased during the period of analysis however, after 42 days MTA still had a discrete inflammatory reaction, this situation was not found with EBOB. Thus, it was concluded that EB has been shown to have similar biological and chemical properties compared with MTA, it also showed less tissue reaction and biocompatibility when tested in rat subcutaneous tissue.
|
2 |
Estudo da biocompatibilidade do cimento de aluminato de cálcio para uso odontológico, avaliação do pH, liberação de íons cálcio e atividade antimicrobiana / Biocompatibility of calcium aluminate cement for dental use, evaluation of pH, calcium ion release and antimicrobial activityFabiano Gamero Aguilar 20 April 2012 (has links)
O objetivo desse estudo foi avaliar o pH, a liberação de íons cálcio, a atividade antimicrobiana in vitro de cimento de aluminato de cálcio (EndoBinder) com diferentes radiopacificadores (óxido de bismuto, óxido de zinco e óxido de zircônia) e a biocompatibilidade do cimento acrescido de óxido de bismuto como agente radiopacificador, em comparação ao mineral trióxido agregado (MTA). Para a avaliação do pH e a liberação de íons cálcio, 25 amostras (n=5) de 2,0 x 10 mm foram obtidas de EndoBinder Puro (EBP), EndoBinder com Óxido de Bismuto (EBOB), EndoBinder com Óxido de Zinco (EBOZn), EndoBinder com Óxido de Zircônia (EBOZr) e Mineral Trióxido Agregado (MTA), que foram imersas em 10 ml água destilada e deionizada (pH=6,9). Após 2, 4, 12, 24, 48 horas, 7, 14 e 28 dias, foi medido o pH e a quantidade de íons cálcio da água onde as amostras foram imersas. Para a determinação in vitro da atividade antimicrobiana dos cimentos (EBP, EBOB, EBOZN, EBOZr e MTA), foram obtidas 15 amostras de cada material (n=3) de 5,0 x 5,0 mm colocadas em contato com 5 tipos de microrganismos: Escherichia coli (ATCC 25922), Enterococcus faecalis (ATCC 29212), Staphylococcus aureus (ATCC 25923), Candida albicans (ATCC 10231) e a Candida glabrata (ATCC 2001) em placas de petri com Agar (Muller Hinton e Sabouraud Dextrose) deixadas em temperatura ambiente por 2 horas para a pré-difusão e depois incubadas a 37°C por 24 horas. Utilizou-se uma régua milimetrada com precisão de 0,5 mm para realizar as medidas dos halos de inibição em torno dos corpos de prova. A biocompatibilidade dos materiais foi avaliada a partir da implantação de tubos de polietileno em tecido subcutâneo de 15 ratos machos, sendo 1 implante escapular e 1 pélvico, num total de 2 tubos por animal (n=5). Como controle, foi utilizada a lateral do tubo de polietileno. Após 7, 21 e 42 dias os animais foram sacrificados e os tecidos processados para a obtenção dos cortes histológicos e posterior análise histopatológica. Os resultados do ensaio de pH, liberação de cálcio e de atividade microbiológica foram submetidos à análise estatística (2-way ANOVA, Bonferroni, p<0,05). Os resultados de biocompatibilidade foram classificados quanto à severidade da reação inflamatória e quantificados em relação aos eventos presentes nas áreas pré-determinadas. Ao final de 28 dias não houve diferença estatística (p>0,05) entre nenhum grupo, tanto para o pH quanto para a liberação de íons cálcio. MTA, EBP e EBOB apresentaram atividade antimicrobiana quando em contato com todos os microrganismos, e EBOZr e EBOZn apenas quando em contato com Staphylococcus aureus e Candida glabrata. A reação inflamatória observada com os implantes subcultâneos diminuiu no decorrer do período de análise, porém ao final de 42 dias MTA ainda apresentou uma discreta reação inflamatória, situação não encontrada com o EB. Desta forma, concluiu-se que EB apresentou propriedades químicas e biológicas semelhantes ao MTA, além de apresentar menor reação tecidual, sendo biocompatível quando testado em tecido subcutâneo de ratos. / The purpose of this study was to evaluate the pH, calcium ion release, in vitro antimicrobial activity of a calcium aluminate cement (EndoBinder) with different radiopacifiers (bismuth oxide, zinc oxide, or zirconium oxide) and the biocompatibility of calcium aluminate cement with bismuth oxide radiopacifier in comparison with the mineral trioxide aggregate (MTA). For the evaluation of pH and calcium ion release 25 sample (n=5) measuring 2,0 x 10 mm were obtained from EndoBinder Pure (EBP), EndoBinder with bismuth oxide (EBOB), EndoBinder with zinc oxide (EBOZn), EndoBinder with zirconium oxide (EBOZr) and mineral trioxide aggregate (MTA) wich were immersed in a flask containing 10 ml of deionized and distilled water (pH=6,9). After 2, 4, 12, 24, 48 hours and 7, 14, 28 days, meassurements of the pH and calcium ion release from the water where the samples were immersed were assessed. To determine the in vitro antimicrobial activity of the cements (EBP, EBOB, EBOZN, EBOZr and MTA) 15 samples of each material (n=3) measuring 5,0 x 5,0 mm were placed in contact with five types of microorganisms: Escherichia coli (ATCC 25922), Enterococcus faecalis (ATCC 29212), Staphylococcus aureus (ATCC 25923), Candida albicans (ATCC 10231) e a Candida glabrata (ATCC 2001) .The MullerHinton agar (MH) diffusion method was employed and the plates were kept at room temperature for 2 hours for pre diffusion and then incubated at 37 C° for 24 hours. Zones of inhibition around the specimens were measured using a 0.5mm precision millimeter ruler. The biocompatibility of the test materials was evaluated from the implantation of 2 polyethylene tubes in the subcutaneous tissue of 15 male rats (n=5), 1 being scapular (EBOB) and 1 pelvic (MTA). The external tube wall was considered as the control group. After 7, 21 and 42 days animals were sacrificed, obtaining 5 tissue samples per group at each time interval of analysis then histological analysis was performed. The test results for pH, calcium ion release and in vitro antimicrobial activity were submitted to statistical analysis (two-way ANOVA, Bonferroni, p <0.05). The results of biocompatibility were classified according to severity of inflammatory reaction and quantified in relation to present events in pre-determined areas. After 28 days there was no statistical difference (p> 0.05) between any group for both the pH and calcium ions release. MTA, EBP and EBOB showed antimicrobial activity against all microorganisms and EBOZr and EBOZn only against Staphylococcus aureus and Candida glabrata. The inflammatory reaction observed with subcutaneous implants decreased during the period of analysis however, after 42 days MTA still had a discrete inflammatory reaction, this situation was not found with EBOB. Thus, it was concluded that EB has been shown to have similar biological and chemical properties compared with MTA, it also showed less tissue reaction and biocompatibility when tested in rat subcutaneous tissue.
|
3 |
Avaliação da radiopacidade, escoamento, pH e da liberação de íons cálcio de um cimento endodôntico biocerâmico / Evaluation of Radiopacity, flow, pH and release of calcium ions of a bioceramic root canal sealerCandeiro, George Taccio de Miranda 02 October 2012 (has links)
O objetivo do presente trabalho foi avaliar as propriedades físico-químicas de um cimento endodôntico biocerâmico, Endosequence BC Sealer (Brasseler USA, Savannah, GA, EUA). Radiopacidade, escoamento, pH e liberação de íons cálcio (Ca2+) foram analisadas e os resultados foram comparados aos do cimento AH Plus (Dentsply De Trey Gmbh, Konstanz, Alemanha). A radiopacidade e o escoamento foram avaliados de acordo com as normas ISO 6876/2001. Para o teste de radiopacidade, anéis metálicos com 10 mm de diâmetro e 1 mm de altura foram preenchidos com os cimentos. O valor da radiopacidade foi determinado de acordo com a densidade radiográfica, representada em mm Al. A análise do escoamento foi feita com 0,05 mL de cada cimento colocados sobre uma placa de vidro. Outra placa de vidro, com 20 g, foi cuidadosamente colocada sobre o cimento e sobre esta um peso de 100 g, totalizando 120 g, que permaneceram por 7 minutos. Em seguida, foram medidos os diâmetros maiores e menores dos discos formados, sendo esta feita com um paquímetro digital. A liberação de íons cálcio (Ca2+) e o pH foram medidos nos períodos de 3, 24, 72, 168 e 240 horas, com o auxílio de um espectrofotômetro e pHmetro, respectivamente. Os resultados foram analisados estatisticamente pelos testes ANOVA e Tukey, sendo considerado significante quando p<0,05. O cimento biocerâmico analisado apresentou radiopacidade (3,84 mm Al) significantemente menor do que o AH Plus (6,90 mm Al). Foi observado que o cimentos Endosequence BC Sealer e o AH Plus apresentaram escoamentos de 26,96 mm e 21,17 mm, respectivamente (p<0,05). O cimento biocerâmico apresentou maior pH e maior liberação de íons cálcio (Ca2+) do que o cimento AH Plus (p<0,05). Concluiu-se que o cimento Endosequence BC Sealer apresentou valores de radiopacidade e de escoamento em concordância com as norma ISO 6876/2001. Os valores de pH e de liberação de íons cálcio (Ca2+) foram favoráveis para um cimento endodôntico. / The aim of the present study was to evaluate the physicochemical properties of a bioceramic root canal sealer, Endosequence BC Sealer. Radiopacity, pH, release of calcium ions (Ca2+) and flow were analyzed and the results were compared with AH Plus cement. Radiopacity and flow were evaluated according to ISO 6876/2001 standards. For the radiopacity analysis, metallic rings with 10 mm in diameter and 1 mm of thickness were filled with cements. The radiopacity value was determined according to radiographic density (mm Al). The flow test was performed with 0.05 mL of cement placed on a glass plate. A 120-g weight was carefully placed over the cement. The largest and smallest diameters of the disks formed were measured using a digital caliper. The release of Ca2+ and pH were measured at periods of 3, 24, 72, 168 and 240 hours, with spectrophotometer and pHmeter, respectively. Data were analyzed by ANOVA and Tukeys test (p<0.05). The bioceramic endodontic cement showed radiopacity (3.84 mm Al) significantly lower than that of AH Plus (6.90 mm Al). The pH analysis showed that Endosequence BC Sealer showed pH and release of Ca2+ greater than those of AH Plus (p<0.05), during the experimental periods. The flow test revealed that the BC Sealer and AH Plus presented flow 26.96 mm and 21.17 mm, respectively (p<0.05). Endosequence BC Sealer showed radiopacity and flow according to ISO 6876/2001 recommendations. The others physicochemical properties analyzed demonstrated favorable values for a root canal sealer.
|
4 |
Avaliação da radiopacidade, escoamento, pH e da liberação de íons cálcio de um cimento endodôntico biocerâmico / Evaluation of Radiopacity, flow, pH and release of calcium ions of a bioceramic root canal sealerGeorge Taccio de Miranda Candeiro 02 October 2012 (has links)
O objetivo do presente trabalho foi avaliar as propriedades físico-químicas de um cimento endodôntico biocerâmico, Endosequence BC Sealer (Brasseler USA, Savannah, GA, EUA). Radiopacidade, escoamento, pH e liberação de íons cálcio (Ca2+) foram analisadas e os resultados foram comparados aos do cimento AH Plus (Dentsply De Trey Gmbh, Konstanz, Alemanha). A radiopacidade e o escoamento foram avaliados de acordo com as normas ISO 6876/2001. Para o teste de radiopacidade, anéis metálicos com 10 mm de diâmetro e 1 mm de altura foram preenchidos com os cimentos. O valor da radiopacidade foi determinado de acordo com a densidade radiográfica, representada em mm Al. A análise do escoamento foi feita com 0,05 mL de cada cimento colocados sobre uma placa de vidro. Outra placa de vidro, com 20 g, foi cuidadosamente colocada sobre o cimento e sobre esta um peso de 100 g, totalizando 120 g, que permaneceram por 7 minutos. Em seguida, foram medidos os diâmetros maiores e menores dos discos formados, sendo esta feita com um paquímetro digital. A liberação de íons cálcio (Ca2+) e o pH foram medidos nos períodos de 3, 24, 72, 168 e 240 horas, com o auxílio de um espectrofotômetro e pHmetro, respectivamente. Os resultados foram analisados estatisticamente pelos testes ANOVA e Tukey, sendo considerado significante quando p<0,05. O cimento biocerâmico analisado apresentou radiopacidade (3,84 mm Al) significantemente menor do que o AH Plus (6,90 mm Al). Foi observado que o cimentos Endosequence BC Sealer e o AH Plus apresentaram escoamentos de 26,96 mm e 21,17 mm, respectivamente (p<0,05). O cimento biocerâmico apresentou maior pH e maior liberação de íons cálcio (Ca2+) do que o cimento AH Plus (p<0,05). Concluiu-se que o cimento Endosequence BC Sealer apresentou valores de radiopacidade e de escoamento em concordância com as norma ISO 6876/2001. Os valores de pH e de liberação de íons cálcio (Ca2+) foram favoráveis para um cimento endodôntico. / The aim of the present study was to evaluate the physicochemical properties of a bioceramic root canal sealer, Endosequence BC Sealer. Radiopacity, pH, release of calcium ions (Ca2+) and flow were analyzed and the results were compared with AH Plus cement. Radiopacity and flow were evaluated according to ISO 6876/2001 standards. For the radiopacity analysis, metallic rings with 10 mm in diameter and 1 mm of thickness were filled with cements. The radiopacity value was determined according to radiographic density (mm Al). The flow test was performed with 0.05 mL of cement placed on a glass plate. A 120-g weight was carefully placed over the cement. The largest and smallest diameters of the disks formed were measured using a digital caliper. The release of Ca2+ and pH were measured at periods of 3, 24, 72, 168 and 240 hours, with spectrophotometer and pHmeter, respectively. Data were analyzed by ANOVA and Tukeys test (p<0.05). The bioceramic endodontic cement showed radiopacity (3.84 mm Al) significantly lower than that of AH Plus (6.90 mm Al). The pH analysis showed that Endosequence BC Sealer showed pH and release of Ca2+ greater than those of AH Plus (p<0.05), during the experimental periods. The flow test revealed that the BC Sealer and AH Plus presented flow 26.96 mm and 21.17 mm, respectively (p<0.05). Endosequence BC Sealer showed radiopacity and flow according to ISO 6876/2001 recommendations. The others physicochemical properties analyzed demonstrated favorable values for a root canal sealer.
|
Page generated in 0.0886 seconds