• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Degradation of organic compounds in paper and testile industrial wastewaters by advanced axidation processes

Pérez Moya, Montserrat 16 November 2001 (has links)
Les activitats de recerca destinades a la solució dels problemes de contaminació de les aigües estan patint un fort increment en els darrers anys. Entre les indústries més contaminants, cal esmentar la tèxtil i la paperera, i més concretament, els efluents provinents d´etapes deblanqueig. Quan els tractaments biològics convencionals d'aquests efluents contaminants no són efectius, la utilització de tecnologies emergents, tals com els processos d´oxidació avançada (AOP´s), basats en la formació in situ de radicals hidroxil, es mostra adient. Amb l´objectiu de provar la viabilitat de tractar efluents contaminants amb el radical hidroxil, vàrem triar l´ozonització i la fotocatàlisi per abordar efluents de blanqueig de pastes papereres generats en el laboratori. Aquesta prova mostrà que la fotocatàlisi pot reduir eficientment el contingut de carrega orgànica tot seguint una equació cinètica de Langmuir-Hinshelwood. A més, la combinació simultània de fotocatàlisi i ozonització produí un efecte sinèrgic que millorava el rendiment respecte al cas d´aplicar ambdós AOP´s de manera seqüencial.Tot i assumint que el radical hidroxil era l´oxidant adequat, planificàrem un extens estudi, fent servir aigües residuals industrials i distints AOP´s. La disminució del TOC i el cost en el tractament varen ésser els paràmetres contrastats en els distints estudis, amb l´objectiu de descobrir els principals avantatges i inconvenients de cada procés. El procés d´ozonització requeria disminuir el seu cost. La presència d´ions ferro en el procés ozó/UVA va aconseguir la reducció d´un 90% de TOC conjuntament amb una disminució del 15% en el cost. L´ús seqüencial de tractaments genera millors resultats (addició de ferro amb o sense llum, seguit per una etapa d´ozonització). Conclusions similars es varen obtenir en treballar amb una matriu sintètica de 2,4-diclorfenol (compost trobat usualment en els efluents de blanqueix de pasta de paper).Referent a la fotocatàlisi, s´ha posat de manifest la necessitat d´utilitzar una font de llum potent i/o la millora de l´eficiència de la llum incident en el catalitzador de TiO2. En aquest sentit vàrem provar dues vies: (a) la utilització d´un nou muntatge experimental amb una font de llum de 125 W. Determinacions d´AOX, toxicitat aguda, fenols i de GC-MS ens van portar a concloure que els compostos orgànics de clor eren eliminats eficientment en l´aigua residual. (b) la utilització de guies d'ones recobertes de TiO2. Solució que permet augmentar l´eficiència amb la que el catalitzador aprofita la llum incident per tal de millorar el disseny de reactors fotocatalitics.L´últim procés provat, el reactiu Fenton, en presència de llum solar o artificial, es va aplicar a la degradació d´efluents de blanqueig tèxtils o paperers. La degradació del contingut de càrrega orgànica d'aquests effluents s´assolia preferentment a pH = 3. El primer estudi es realitzà sobre un efluent de blanqueig de pastes de paper. La funció aproximada del sistema, estimada a partir del disseny experimental, mostrà que concentracions inicials inadequades de reactiu Fenton afectaven negativament al procés, a causa de reaccions competitives entre aquest i altres espècies oxidatives. Així mateix, la temperatura augmentà clarament les velocitats de la reacció, inclús sense presència de radiació. La millora en la disminució del TOC és particularment significativa quan les proporcions de reactiu Fenton són inadequades (en passar de 25 ºC a 40 ºC es pot aconseguir una reducció en el cost de l´ordre del 80%). Per altre banda, la llum solar aconsegueix reduir fins un 70 % el cost total d'un tractament de dues hores de durada. L'anàlisi de GC-MS constata l´eliminació dels compostos clorfenòlics. Un segon estudi sobre un efluent tèxtil corroborà la gran importància de la temperatura i de la presència de llum solar. En resum, tots els AOP´s provats mostren, sota condicions experimentals adequades, la capacitat de degradació del contingut orgànic present en efluents de blanqueig procedents d´indústries papereres i tèxtils. / There is an ever increasing amount of research activities especially devoted to the solution of water pollution problems.The pulp and textile industries are considered to be some of the largest polluters of all industries. The biggest problem with those industries consists in the polluted effluents discharged during the bleaching process because conventional biological treatments are not effective in treating these toxic pollutants. In these cases, the emerging technologies called Advanced Oxidation Processes (AOPs) represent an attempt to mineralize the contaminants by the in situ formation of hydroxyl radicals.In order to determine the effectiveness of treating effluents with the hydroxyl radical we chose the photocatalytic and ozonation processes to treat bleaching pulp effluents generated in the laboratory. Our results demonstrated that the photocatalytic process could efficiently reduce the organic content in accordance with the Langmuir-Hinshelwood kinetic equation. Moreover, simultaneously combining photocatalysis and ozonation provided a synergistic effect that was superior in performance to that of applying the photocatalysis and ozonation processes sequentially.Our tests with laboratory bleaching pulp effluents assumed that the hydroxyl radical was the proper oxidant to be use. An extensive study was undertaken using industrial wastewaters and different AOPs. TOC decay and treatment costs were the operative variables compared in the study in order to discover the benefits and shortcomings of each process.It is imperative that the ozonation process decreases the treatment costs. The addition of iron ions to bleaching mill wastewater undergoing ozone/UVA treatment resulted in high rates of TOC removal (90%) and in a significant cost reduction (15%). Additionally, sequential processing (stirred iron, with or without light irradiation, followed by an ozonation stage) led to even better results. Similar results were obtained on the synthetic sample of 2,4-dichlorophenol (a compound typically found in paper pulp bleaching effluents) investigated. We noticed that the photocatalytic process requires either a powerful light source or an improvement of the light utilization efficiency of the TiO2 catalyst, or maybe both, to be most effective. We tested two strategies: (a) A new experimental setup that used a high power light (125 W) to accelerate the reaction rate. AOX, acute toxicity, phenol and a GC-MS analysis led us to conclude that the chlorine organic compounds were efficiently eliminated from the treated wastewater. (b) The second approach consisted in using titanium dioxide (TiO2)-coated waveguides. This approach increases the light utilization efficiency of the TiO2 catalyst with the aim of improve the reactor's design.The last process that was tested involved the addition of Fenton reagent to the bleaching pulp and textile effluents in conjunction with either artificial or solar light The degradation of the organic contents was successfully performed at pH = 3.The first study was performed on bleaching pulp effluent. The approximate function of the system, as assessed by the experimental design, showed that initial non-optimum concentrations of the Fenton reagent were detrimental to the process because of competitive reactions of the Fenton reagent with oxidative species. On the other hand, temperature markedly increased the reaction rates, even without light irradiation. The improvement in TOC removal was particularly significant when the reagent ratios were not optimal. A decrease in cost around 80% is possible by just increasing the temperature from 25ºC to 40ºC. Moreover, solar light reduced the total cost of a two hour treatment by up to 70 % and efficiently removed the chlorophenolic compounds as shown by GC-MS analysis.The second study performed on textile wastewater corroborates the importance of the temperature parameter and the utility of solar energy. In summary, all AOPs tested displayed the capability to degrade the organic components of bleaching Kraft mill and textile mill effluents under suitable experimental conditions.
2

Mecanisme enzimàtic de la 1,3-1,4-β-glucanasa de Bacillus licheniformis: estudis cinètics en estat estacionari i preestacionari

Abel Lluch, Mireia 22 January 2009 (has links)
Les glicosidases que hidrolitzen els substrats amb retenció de configuració segueixen un mecanisme general en què després d'una primera etapa d'associació enzim-lligand s'encadenen dues etapes catalítiques que porten a la hidròlisi del substrat conservant la configuració del carboni anomèric en el nou extrem generat. En el present treball es comprova a través d'estudis mecanístics, principalment estudis en estat preestacionari i anàlisis de Hammett, que amb aquest mecanisme tan senzill no es pot descriure correctament l'activitat catalítica de la 1,3-1,4-β-glucanasa de Bacillus licheniformis, i es proposa el mecanisme que es mostra a continuació: on els complexos enzim-substrat adopten dues conformacions productives (SES* i SES**) i on el balanç entre aquestes dues conformacions en funció del substrat explica els diferents comportaments cinètics en estat estacionari i preestacionari.Un estudi en profunditat sobre la importància que exerceix la interacció entre l'enzim i l'hidroxil a C2 de la unitat de glucopiranosa que ocupa el subseti -1 demostra que en el cas de la 1,3-1,4-β-glucanasa de Bacillus licheniformis aquesta interacció no juga el paper rellevant que s'ha observat en altres β-glicosidases que actuen amb retenció de configuració.L'estudi de la reacció d'hidratació del glical G4G3G' catalitzada per la 1,3-1,4-β-glucanasa de Bacillus licheniformis permet proposar que hi ha un canvi en el residu que fa el paper d'àcid general. De manera que es proposa que l'Asp136 que en la reacció d'hidròlisi de substrats ajuda al posicionament dels residus catalítics i juga un paper en la regulació dels seus pKa, és el residu que fa d'àcid general en la reacció d'hidratació de glicals. / Las glicosidasas que hidrolizan substratos con retención de configuración siguen un mecanismo general en que después de una primera etapa de asociación enzima-ligando se encadenan dos etapas catalíticas que llevan a la hidrólisis del substrato conservando la configuración del carbono anomérico en el nuevo extremo generado. En el presente trabajo se comprueba a través de estudios mecanísticos, principalmente estudios en estado pre-estacionario y análisis de Hammett, que con este mecanismo tan sencillo no se puede describir correctamente la actividad catalítica de la 1,3-1,4-β-glucanasa de Bacillus licheniformis, y se propone el mecanismo que se muestra a continuación: donde los complejos enzima-substrato adoptan dos conformaciones productivas (SES* y SES**) y donde el balance entre estas dos conformaciones en función del substrato explica los diferentes comportamientos cinéticos en estado estacionario y pre-estacionario.Un estudio en profundidad sobre la importancia que ejerce la interacción entre el enzima y el hidroxilo en C2 de la unidad de glucopiranosa que ocupa el subsitio -1 demuestra que en el caso de la 1,3-1,4-β-glucanasa de Bacillus licheniformis esta interacción no juega el papel relevante que se ha observado en otras β-glicosidasas que actuan con retención de configuración.El estudio de la reacción de hidratación del glical G4G3G' catalizada por la 1,3-1,4-β-glucanasa de Bacillus licheniformis permite proponer que hay un cambio en el residu que ejerce el papel de ácido general. De manera que se propone que el Asp136 que en la reacción de hidrólisis de substratos ayuda en el posicionamiento de los resíduos catalíticos y juega un papel en la regulación de sus pKa, es el resíduo que actúa de ácido general en la reacción de hidratación de glicales. / Retaining glycosidases follow a general mechanism in which the first enzime-ligand association is followed by two catalytic steps that render the product of hydrolysis with the same anomeric configuration as the starting material. In the present work we demonstrate using mechanistic studies, basically pre-steady state kinetics and Hammett analysis, that this mechanism is too simple to properly describe the catalytic activity of Bacillus licheniformis 1,3-1,4-β-glucanase, and the following mechanism is proposed: In this mechanism, the enzim-substrate complexes adopt two productive conformations (SES* and SES**) and the balance between these two conformations depending on the nature of the substrate explains the diferent behaviours observed in pre-steady and steady state kinetics.A deep study on the importance of the interaction between the enzyme and the hydroxyl group at C2 of the glucopyranose residue that occupies the -1 subsite demonstrates that in Bacillus licheniformis 1,3-1,4-β-glucanase this interaction is not the key interaction observed in other retaining β-glycosidases.The study of the G4G3G' glical hydration catalysed by the Bacillus licheniformis 1,3-1,4-β-glucanase let us propose that there is a change in the residue that acts as a general acid. We propose that Asp136, that plays a role positioning the catalytic residues and modulating their pKa in the hydrolysis reaction, acts as the general acid in the hydration of glycals.

Page generated in 0.574 seconds