• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • Tagged with
  • 7
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avalia??o da climatiza??o e irradia??o na manuten??o de qualidade de frutos de banana ?Prata? e ?Prata-an??. / Evaluation of climatization and irradiation in maintenance of fruit quality of banana 'Prata' and 'Prata-an??.

Martineli, Maristella 26 February 2010 (has links)
Submitted by Sandra Pereira (srpereira@ufrrj.br) on 2018-08-20T14:30:41Z No. of bitstreams: 1 2010 - Maristella Martineli.pdf: 1214722 bytes, checksum: cccf10ab7c5117e38284ec2878f3a0a6 (MD5) / Made available in DSpace on 2018-08-20T14:30:41Z (GMT). No. of bitstreams: 1 2010 - Maristella Martineli.pdf: 1214722 bytes, checksum: cccf10ab7c5117e38284ec2878f3a0a6 (MD5) Previous issue date: 2010-02-26 / Funda??o Carlos Chagas Filho de Amparo ? Pesquisa do Estado do RJ, FAPERJ, Brasil. / The experiment was conducted at the Postharvest Laboratory of UFRRJ, aiming to observe the effects of competition of the processes of irradiation and climatization sequences, on the maturation of banana 'Prata' and 'Prata an??. For the treatments, the fruits were separated into two lots. The first batch was taken to Centro Tecnol?gico do Ex?rcito (CTEx), in Rio de Janeiro, to receive doses of 0.25 kGy and 0.50 kGy in irradiator with a source of 137Cs. The second batch remained in the Postharvest Laboratory, and were underwent to exposure of calcium carbide in a dose of 7 g m-?. Part of the first batch returned to the Laboratory, being exposed under the same conditions and doses of calcium carbide. In the same manner described above, part of the second batch was taken to CTEx for exposure to the same doses of gamma radiation from the first batch. Two experiments were conducted separately. In both experiments, we evaluated the skin color, index of diseases, weight loss, firmness, peel chlorophyll, acidity, starch, soluble solids, enzymatic activity (pectinmetilesterase) and respiratory activity. In the first experiment, fruits of banana 'Prata' underwent a randomized design in factorial 8x5, except for evaluations of starch and pectinmetilesterase (8x3) and firmness (8x2). The average temperature of storage was 27 ? C. In experiment two, fruits of banana 'Prata-dwarf "were also subjected to completely randomized design with 8x5 factorial design (skin color, index and weight loss) and 8x3 for the other variables. The average temperature of storage was 23 ? C. In Experiments 1 and 2 for respiratory activity, we used a split plot design in time, with six replicates. Under the conditions of this study, the fruits obtained in the region of Angra dos Reis, Rio de Janeiro showed no positive responses in terms of quality with the application of irradiation, suggesting that the inappropriate handling of the fruits in the field, significantly influenced the results in post-harvest when the irradiation was used as a process to increase their useful life. The sequence of processes used, climatization and irradiation, regardless of the order, did not show different effects, since the fruits of both cultivars showed similar behavior during storage. More evident for the banana ?Prata-an??, treatment with gamma radiation at 0.25 kGy dose alone was effective in slowing the processes that lead to maturity / O experimento foi conduzido no Laborat?rio de P?s-Colheita da UFRRJ, com os objetivos de observar os efeitos da competi??o dos processos de irradia??o e climatiza??o seq?enciais, sobre a matura??o banana ?Prata? e ?Prata-an?. Para aplica??o dos tratamentos, os frutos foram separados em dois lotes. O 1? lote foi levado ao Centro Tecnol?gico do Ex?rcito no RJ (CTEx) para receber as doses de 0,25 kGy e 0,50 kGy em irradiador com fonte de 137Cs. O 2? lote permaneceu no Laborat?rio de P?s-Colheita, no qual foram submetidos ? exposi??o do carbureto de c?lcio na dose de 7 g m-?. Parte do 1? lote retornou ao Laborat?rio de P?s-Colheita, sendo exposta, nas mesmas condi??es e doses do carbureto de c?lcio. Da mesma forma descrita anteriormente, parte do 2? lote foi levado ao CTEx para exposi??o ?s mesmas doses de radia??o gama do 1? lote. Foram realizados dois experimentos separadamente. Nos dois experimentos, avaliou-se a colora??o da casca, ?ndice de doen?as, perda de massa fresca, firmeza, clorofila total da casca, acidez titul?vel, amido, s?lidos sol?veis totais, atividade enzim?tica (pectinametilesterase) e atividade respirat?ria. No experimento 1, frutos de banana ?Prata? foram submetidos a um delineamento inteiramente casualizado, em esquema fatorial 8x5, exceto para as avalia??es de amido e pectinametilesterase (8x3) e firmeza (8x2). A temperatura m?dia de armazenamento foi de 27? C. No experimento 2, frutos de banana ?Prata-an?? tamb?m foram submetidos ao delineamento inteiramente casualizado com esquema fatorial 8x5 (cor casca, ?ndice de doen?as e perda de massa fresca) e 8x3 para as demais vari?veis. A temperatura m?dia de armazenamento foi de 23? C. Nos experimentos 1 e 2, para a atividade respirat?ria, utilizou-se esquema de parcela subdividida no tempo, com 6 repeti??es. Nas condi??es do presente trabalho os frutos obtidos na regi?o de Angra dos Reis/RJ n?o apresentaram respostas positivas em termos de qualidade com a aplica??o da irradia??o, denotando que o manejo inadequado dos frutos em campo, influenciou significativamente nos resultados em p?s-colheita quando a irradia??o foi utilizada como processo para aumentar a vida ?til dos mesmos. A sequ?ncia dos processos utilizados, climatiza??o e irradia??o, independente da ordem, n?o apresentou efeitos diferenciados, uma vez que, os frutos, de ambas as cultivares, apresentaram comportamento semelhante durante o armazenamento. De forma mais evidente para a banana ?Prata-an??, o tratamento com radia??o gama na dose 0,25 kGy isolada foi eficiente em retardar os processos que levam ao amadurecimento.
2

Comportamento e termorregulação de vacas Holandesas lactantes frente a recursos de ventilação e nebulização em estabulação livre / Holstein milking cows behaviour and thermoregulation under fun and mist housing resources in free-stall

Vilela, Reíssa Alves 11 December 2008 (has links)
Este estudo teve como objetivo avaliar a influência de recursos de climatização, ventilação e nebulização sobre a fisiologia e o comportamento de vacas Holandesas alojadas em free-stall, durante o verão do sudeste brasileiro. Foram utilizadas 20 vacas Holandesas lactantes em duas fases experimentais. No experimento I, foram avaliados os efeitos do tratamento ventilação e nebulização e, no experimento II, analisou-se a influência da ventilação isolada. Os parâmetros ambientais registrados foram temperatura do ar, umidade relativa, temperatura de globo negro e pluviosidade, e posteriormente, foi calculado o índice do globo negro e umidade. Os parâmetros fisiológicos avaliados foram temperatura retal, temperatura caudal e freqüência respiratória. Os parâmetros comportamentais observados foram atividade, postura, posição e localização dos animais dentro da instalação. Para obtenção das estatísticas descritivas para as variáveis fisiológicas e comportamentais foi utilizada metodologia de quadrados mínimos. As variáveis fisiológicas para ambas fases experimentais não apresentaram diferenças e indicaram conforto térmico. As respostas comportamentais indicaram que o estudo do comportamento é uma ferramenta importante na avaliação do bem-estar dos animais. O sistema de climatização, com ventilação e nebulização, associadas ou não, podem proporcionar um ambiente de maior conforto, determinando alterações comportamentais. / This studys main goal was to evaluate the influence of resources of climatization, fun and mist, on the physiology and the behaviour of Holstein cows housed in free-stall, during Brazilian southeast summer. Was used twenty Holstein milking cows in two experiments. In Trial one the effects of fun and mist were evaluated and in Trial II the influence of fun was analyzed. The environmental parameters registered were air temperature, relative humidity, black globe temperature and rain precipitation, and subsequently was computed the black globe temperature and humidity index. The physiological parameters evaluated were rectal temperature, tail basis temperature and respiratory rate. The behavioral parameters observed were activity, posture and animal position inside of stall. The obtainment of descriptive statistical for the physiological and behavioral variables was used the minimum square method. There were no differences in the physiological variables for both phases indicating thermal comfort. The behavioral responses indicated that the behaviour study is an important tool to evaluate the animal welfare. The climatization system with fun, with or without mist, can to promote an environment with more comfort, determining behavioral changes.
3

Caracterização de rotores adsortivos para composição de sistemas de climatização por adsorção / Adsortive wheel characterization for composition climatization by adsorption systems.

Melo, Francisco José Araujo 26 February 2015 (has links)
Submitted by Maria Suzana Diniz (msuzanad@hotmail.com) on 2015-11-11T15:24:04Z No. of bitstreams: 1 arquivototal.pdf: 2659414 bytes, checksum: daffe4d3b79a46f98678d09a7952e81b (MD5) / Made available in DSpace on 2015-11-11T15:24:04Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 2659414 bytes, checksum: daffe4d3b79a46f98678d09a7952e81b (MD5) Previous issue date: 2015-02-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / In this work, will be characterized two types of adsorptive wheels, an active effect and the other passive effect, known respectively as desiccant wheel and enthalpy wheel. These devices are used to compose the climatization adsorption systems as a means of promoting the dehumidification of air using the adsorption phenomenon that occurs in their adsorptive matrices. This phenomenon involves both the mass transfer and the heat, its cycles are defined by two processes taking place simultaneously, the adsorption and desorption. In the study, the characterization will boil down to assess the equipment in different working conditions with the main objective to achieve better dehumidification of air using the least amount of energy possible. Procedures were used for low air flow rates set in three categories: the process flow, which is the airflow to be treated, or dehumidified, a regeneration flow, which is the air stream in countercurrent flow desiccant rotor with process flow will serve as a means of maintaining the adsorptive cycle always performing heat exchange and mass, and the return flow, which flow against the enthalpy rotor will also serve as a means of promoting the dehumidification of process air. In the regeneration flow rates will be assessed the effects of low temperature heating and in both wheels will be evaluated the effects of different rotational speeds. Will also take place, procedures in order to verify the possibility of the wheel enthalpy work as a wheel desiccant . The findings contributed significantly to the climate control by adsorption systems is taken increasingly as a viable alternative to replacing conventional cooling. / No presente trabalho foram caracterizados dois tipos de rotores adsortivos, um de efeito ativo e outro de efeito passivo, conhecidos respectivamente como rotor dessecante e rotor entálpico. Esses equipamentos são usados para compor os sistemas de climatização por adsorção como meio de promover a desumidificação do ar usando o fenômeno da adsorção que ocorre em suas matrizes adsortivas. Esse fenômeno envolve tanto a transferência de massa quanto a de calor, seus ciclos são definidos por dois processos que ocorrem simultaneamente, a adsorção e a dessorção. No estudo, a caracterização se resume em avaliar os equipamentos em diferentes condições de trabalho tendo como principal objetivo alcançar a melhor desumidificação do ar usando a menor quantidade de energia possível. Durante os procedimentos foram usadas baixas vazões de ar definidas em três categorias: a vazão de processo, que é a corrente de ar a ser tratada, ou seja, desumidificada, a vazão de regeneração, que é a corrente de ar que em contra fluxo no rotor dessecante com a vazão de processo servirá como meio de manter o ciclo adsortivo sempre realizando as trocas de calor e massa, e a vazão de retorno, que em contra fluxo no rotor entálpico servirá também como meio de promover a desumidificação do ar de processo. Nas vazões de regeneração foram avaliados os efeitos de baixas temperaturas de aquecimento e em ambos os rotores foram avaliados os efeitos de diferentes rotações. Foram realizados também, procedimentos com o intuito de verificar a possibilidade de o rotor entálpico trabalhar como rotor dessecante. Os resultados desse trabalho contribuíram significativamente para que os sistemas de climatização por adsorção seja tido cada vez como uma alternativa viável à substituição da refrigeração convencional.
4

Comportamento e termorregulação de vacas Holandesas lactantes frente a recursos de ventilação e nebulização em estabulação livre / Holstein milking cows behaviour and thermoregulation under fun and mist housing resources in free-stall

Reíssa Alves Vilela 11 December 2008 (has links)
Este estudo teve como objetivo avaliar a influência de recursos de climatização, ventilação e nebulização sobre a fisiologia e o comportamento de vacas Holandesas alojadas em free-stall, durante o verão do sudeste brasileiro. Foram utilizadas 20 vacas Holandesas lactantes em duas fases experimentais. No experimento I, foram avaliados os efeitos do tratamento ventilação e nebulização e, no experimento II, analisou-se a influência da ventilação isolada. Os parâmetros ambientais registrados foram temperatura do ar, umidade relativa, temperatura de globo negro e pluviosidade, e posteriormente, foi calculado o índice do globo negro e umidade. Os parâmetros fisiológicos avaliados foram temperatura retal, temperatura caudal e freqüência respiratória. Os parâmetros comportamentais observados foram atividade, postura, posição e localização dos animais dentro da instalação. Para obtenção das estatísticas descritivas para as variáveis fisiológicas e comportamentais foi utilizada metodologia de quadrados mínimos. As variáveis fisiológicas para ambas fases experimentais não apresentaram diferenças e indicaram conforto térmico. As respostas comportamentais indicaram que o estudo do comportamento é uma ferramenta importante na avaliação do bem-estar dos animais. O sistema de climatização, com ventilação e nebulização, associadas ou não, podem proporcionar um ambiente de maior conforto, determinando alterações comportamentais. / This studys main goal was to evaluate the influence of resources of climatization, fun and mist, on the physiology and the behaviour of Holstein cows housed in free-stall, during Brazilian southeast summer. Was used twenty Holstein milking cows in two experiments. In Trial one the effects of fun and mist were evaluated and in Trial II the influence of fun was analyzed. The environmental parameters registered were air temperature, relative humidity, black globe temperature and rain precipitation, and subsequently was computed the black globe temperature and humidity index. The physiological parameters evaluated were rectal temperature, tail basis temperature and respiratory rate. The behavioral parameters observed were activity, posture and animal position inside of stall. The obtainment of descriptive statistical for the physiological and behavioral variables was used the minimum square method. There were no differences in the physiological variables for both phases indicating thermal comfort. The behavioral responses indicated that the behaviour study is an important tool to evaluate the animal welfare. The climatization system with fun, with or without mist, can to promote an environment with more comfort, determining behavioral changes.
5

Avaliação da eficiência produtiva e energética de sistemas de climatização em galpões tipo "Freestall" para confinamento de gado leiteiro. / Evaluation of productive and energetic efficiency of climatization system in dairy cattle free-stall.

Perissinotto, Mauricio 28 January 2004 (has links)
O presente trabalho teve como objetivo geral avaliar a eficiência técnica e econômica do sistema de resfriamento adiabático evaporativo (SRAE) na produção intensiva de leite e como objetivos específicos avaliar a eficiência térmica dos sistemas de resfriamento (aspersão e nebulização), conjugados com a ventilação forçada, na resposta produtiva dos animais, na redução do estresse térmico, seus reflexos no microclima interno e sua eficiência econômica quanto ao consumo de energia e de água. O experimento foi realizado em uma fazenda comercial de produção leiteira, localizada no interior do Estado de São Paulo. Em cada tratamento foram utilizados 10 animais da raça Holandesa em produção, selecionados de acordo com a produção e período de lactação, alojados em sistema de "freestall". Dos animais selecionados cinco foram utilizados para a tomada dos dados fisiológicos dos animais (freqüência respiratória, temperatura retal e temperatura do pelame branco e preto, medidos nos horários das 9, 11, 13, 15 e 17 horas, durante nove dias não consecutivos), e cinco animais foram utilizados para a avaliação comportamental (localização e atividades dentro da instalação), sendo para tanto utilizadas vídeo - câmeras das 9 às 17 horas durante seis dias. O período experimental compreendeu vinte e oito dias consecutivos do mês de novembro de 2003, sendo sete dias utilizados para a adaptação dos animais aos tratamentos testados e vinte e um dias para a coleta de dados. Os dados climáticos (temperatura e umidade relativa do ar e temperatura de globo negro) em cada tratamento e externo à instalação foram registradas a cada 15 minutos ao longo das 24 horas por um data logger HOBO ® , possibilitando o cálculo do Índice de Temperatura e Umidade (THI), do Índice de Globo Negro e Umidade (BGHI) e da entalpia (H). Foram utilizados ventiladores com capacidade de movimentar o ar a 2,5 m.s -1 que, assim como os sistemas de aspersão e nebulização, foram controlados por um termostato e distribuídos ao longo da linha de cocho das instalações. As variáveis respostas consideradas foram: produção de leite, consumo de alimento pelos animais, comportamento dos animais, consumo de água e de energia pelos sistemas de resfriamento e dados fisiológicos dos animais. A avaliação dos dados foi realizada por um delineamento experimental em blocos ao acaso, utilizando-se na análise estatística a comparação de médias pelo teste de Tukey ao nível de 1%. Para a análise geral dos resultados foi utilizado o pacote estatístico SAS (SAS User guide: Statistics (release 6.03). SAS Inst. Inc., 1990). Considerando que os tratamentos estudados: aspersão e nebulização associadas à ventilação forçada promoveram um consumo alimentar semelhante (diferença de 3,0 kg MS -1 .animal -1 .mês -1 ) observou-se que o sistema de resfriamento com aspersão apesar de apresentar um consumo de água e energia maior (7535,7 litros.animal -1 .mês -1 e 13,15 kW.h -1 .animal -1 .mês -1 , respectivamente) promoveu um aumento na produção de leite de 3% (18,0 litros/animal/mês) ocasionando um aumento na receita mensal total de aproximadamente 5,8% por animal quando comparado ao sistema de nebulização. / This work aimed to evaluate the economical and technical efficiency of evaporative adiabatic cooling system (EACS) for intensive milk production. Its specific objectives were to evaluate thermal efficiency of chilling systems (aspersion and sprinkler) associated with forced air fan on productive traits, heat stress reduction, internal micro-climate, and economical advantages in relation to water and energy expenses. Experiment was carried out in a commercial dairy cattle farm located in a small city of São Paulo State. In each treatment were used 10 dairy-Holstein cows sorted according to their milk production and lactation order, in a free-stall system. Among these cows, five were selected for collecting physiological data (respiratory frequency, rectal temperature and temperature in white and black pelage) at 9:00 a.m., 11:00 a.m., 1:00 p.m., 3:00 p.m. and 5:00 p.m. during nine non-consecutive days. Other five animals were evaluated for their behavior (localization and activities inside facilities) through video-cameras from 9:00 a.m. to 5:00 p.m. during six days. Experimental period was twenty-eight consecutive days of November 2003, being the first seven days for animal adaptation and the last twenty-one for data collection. Climate data (relative air temperature and humidity, and dark globe temperature), in each treatment and outside of facility, were taken in intervals of 15 minutes during 24 hours by HOBO ® data logger, which permitted to calculate the Humidity and Temperature Index (HTI), Humidity and Dark Globe Index (HDGI) and Enthalpy (E). Fan with 2.5 m.s -1 of air mobility capacity associated to aspersion and sprinkler systems, were controlled by thermostat and distributed following feeder line of free-stall. Production variables considered were: milk production, feed intake, animal behavior, water and energy consumption of cooling system, and animal physiological traits. Data evaluation was realized in a completely randomized block design using in statistical analysis Tukey’s test with 1% of significance level. General analysis of results was performed through SAS proceedings. Considering that treatments promoted similar feed intake (the difference was 3.0 kg DM.animal -1 .month -1 ), the chilling system associated to aspersion led to an increase (18.0 liters.animal -1 .month -1 ) in 3% milk production in spite of its higher consumption of water and energy (7535.7 liters.animal -1 .month -1 and 2.3 kW.h -1 .animal -1 .month -1 , respectively). As consequence, it was observed an increase of 4.7% in total mensal profit in relation to sprinkler system.
6

Avaliação da eficiência produtiva e energética de sistemas de climatização em galpões tipo "Freestall" para confinamento de gado leiteiro. / Evaluation of productive and energetic efficiency of climatization system in dairy cattle free-stall.

Mauricio Perissinotto 28 January 2004 (has links)
O presente trabalho teve como objetivo geral avaliar a eficiência técnica e econômica do sistema de resfriamento adiabático evaporativo (SRAE) na produção intensiva de leite e como objetivos específicos avaliar a eficiência térmica dos sistemas de resfriamento (aspersão e nebulização), conjugados com a ventilação forçada, na resposta produtiva dos animais, na redução do estresse térmico, seus reflexos no microclima interno e sua eficiência econômica quanto ao consumo de energia e de água. O experimento foi realizado em uma fazenda comercial de produção leiteira, localizada no interior do Estado de São Paulo. Em cada tratamento foram utilizados 10 animais da raça Holandesa em produção, selecionados de acordo com a produção e período de lactação, alojados em sistema de "freestall". Dos animais selecionados cinco foram utilizados para a tomada dos dados fisiológicos dos animais (freqüência respiratória, temperatura retal e temperatura do pelame branco e preto, medidos nos horários das 9, 11, 13, 15 e 17 horas, durante nove dias não consecutivos), e cinco animais foram utilizados para a avaliação comportamental (localização e atividades dentro da instalação), sendo para tanto utilizadas vídeo - câmeras das 9 às 17 horas durante seis dias. O período experimental compreendeu vinte e oito dias consecutivos do mês de novembro de 2003, sendo sete dias utilizados para a adaptação dos animais aos tratamentos testados e vinte e um dias para a coleta de dados. Os dados climáticos (temperatura e umidade relativa do ar e temperatura de globo negro) em cada tratamento e externo à instalação foram registradas a cada 15 minutos ao longo das 24 horas por um data logger HOBO ® , possibilitando o cálculo do Índice de Temperatura e Umidade (THI), do Índice de Globo Negro e Umidade (BGHI) e da entalpia (H). Foram utilizados ventiladores com capacidade de movimentar o ar a 2,5 m.s -1 que, assim como os sistemas de aspersão e nebulização, foram controlados por um termostato e distribuídos ao longo da linha de cocho das instalações. As variáveis respostas consideradas foram: produção de leite, consumo de alimento pelos animais, comportamento dos animais, consumo de água e de energia pelos sistemas de resfriamento e dados fisiológicos dos animais. A avaliação dos dados foi realizada por um delineamento experimental em blocos ao acaso, utilizando-se na análise estatística a comparação de médias pelo teste de Tukey ao nível de 1%. Para a análise geral dos resultados foi utilizado o pacote estatístico SAS (SAS User guide: Statistics (release 6.03). SAS Inst. Inc., 1990). Considerando que os tratamentos estudados: aspersão e nebulização associadas à ventilação forçada promoveram um consumo alimentar semelhante (diferença de 3,0 kg MS -1 .animal -1 .mês -1 ) observou-se que o sistema de resfriamento com aspersão apesar de apresentar um consumo de água e energia maior (7535,7 litros.animal -1 .mês -1 e 13,15 kW.h -1 .animal -1 .mês -1 , respectivamente) promoveu um aumento na produção de leite de 3% (18,0 litros/animal/mês) ocasionando um aumento na receita mensal total de aproximadamente 5,8% por animal quando comparado ao sistema de nebulização. / This work aimed to evaluate the economical and technical efficiency of evaporative adiabatic cooling system (EACS) for intensive milk production. Its specific objectives were to evaluate thermal efficiency of chilling systems (aspersion and sprinkler) associated with forced air fan on productive traits, heat stress reduction, internal micro-climate, and economical advantages in relation to water and energy expenses. Experiment was carried out in a commercial dairy cattle farm located in a small city of São Paulo State. In each treatment were used 10 dairy-Holstein cows sorted according to their milk production and lactation order, in a free-stall system. Among these cows, five were selected for collecting physiological data (respiratory frequency, rectal temperature and temperature in white and black pelage) at 9:00 a.m., 11:00 a.m., 1:00 p.m., 3:00 p.m. and 5:00 p.m. during nine non-consecutive days. Other five animals were evaluated for their behavior (localization and activities inside facilities) through video-cameras from 9:00 a.m. to 5:00 p.m. during six days. Experimental period was twenty-eight consecutive days of November 2003, being the first seven days for animal adaptation and the last twenty-one for data collection. Climate data (relative air temperature and humidity, and dark globe temperature), in each treatment and outside of facility, were taken in intervals of 15 minutes during 24 hours by HOBO ® data logger, which permitted to calculate the Humidity and Temperature Index (HTI), Humidity and Dark Globe Index (HDGI) and Enthalpy (E). Fan with 2.5 m.s -1 of air mobility capacity associated to aspersion and sprinkler systems, were controlled by thermostat and distributed following feeder line of free-stall. Production variables considered were: milk production, feed intake, animal behavior, water and energy consumption of cooling system, and animal physiological traits. Data evaluation was realized in a completely randomized block design using in statistical analysis Tukey’s test with 1% of significance level. General analysis of results was performed through SAS proceedings. Considering that treatments promoted similar feed intake (the difference was 3.0 kg DM.animal -1 .month -1 ), the chilling system associated to aspersion led to an increase (18.0 liters.animal -1 .month -1 ) in 3% milk production in spite of its higher consumption of water and energy (7535.7 liters.animal -1 .month -1 and 2.3 kW.h -1 .animal -1 .month -1 , respectively). As consequence, it was observed an increase of 4.7% in total mensal profit in relation to sprinkler system.
7

Sistema híbrido de resfriamento evaporativo e compressão a vapor para condicionamento do ar em veículos

Eric Ferreira dos Santos 30 September 2011 (has links)
Reunir o condicionamento de ar indireto pela compressão a vapor, usando o fluido refrigerante R134a, ao princípio de resfriamento evaporativo direto, foi o tema foco do trabalho. O resfriamento a compressão de vapor tem como resultado, a entrega do ar condicionado sob condições de conforto que podem ser modificados de modo significativo, se for adicionado aos resultados, o condicionamento por resfriamento evaporativo. A observação dos experimentos se baseou nos processos psicrométricos envolvidos, aliando a saturação adiabática do ar no resfriamento evaporativo conjugado ao efeito frigorífico da diferença de entalpias na entrada e saída do evaporador no ciclo convencional de resfriamento. Foi possível avaliar a redução do coeficiente de desempenho e a capacidade de refrigeração aumentando em função do crescimento da rotação do compressor. No ensaio conjugado, resfriamento evaporativo e compressão a vapor instalados em série, observou-se a redução da efetividade do resfriador evaporativo, quando ocorre o aumento da vazão de ar, além do incremento da capacidade de refrigeração em função da associação dos dois sistemas, sem que houvesse aumento significativo da potência consumida. / Assemble the air conditioning by indirect vapor-compression, using refrigerant R134a, the principle of evaporative cooling direct cooling, was the subject focus of the work. The vapor compression cooling results in the delivery of air conditioning under conditions of comfort that can be changed significantly if we add the results, the conditioning by evaporative cooling. The observation of the experiments are bases on psychometric processes involved, combining the adiabatic saturation of air in the evaporative cooling effect of the combined refrigerator of the difference in enthalpy at the inlet and outlet of the evaporator in the conventional cooling cycle. It was possible to evaluate the reduction of the coefficient of performance and cooling capacity increase due to the increase of compressor speed. During the serial aligned pads evaporative cooling and vapor compression test, there was a decrease of the effectiveness evaporative cooler, when the air flow was added, in addition, it was increased the cooling capacity according to the association of the two systems, with no significant increase the power supplied.

Page generated in 0.1115 seconds